Tender For Spl Repair To Bldgs No T-112 (Gd Room), P-22, P-24, P-34 And P-194 (Store) At Mil Stn Ratnuchak Under Ge Kaluchak.; 1 Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) and removing from site complete all as specified. (The disturbed surface during taking down shall be made good by the contractor without any extra cost for fixing new one ofany description. No extra cost is permissible for the material and labour for making good the disturbed surface, complete all as specified and directed. 2 Taking down chowkhats or frames areaexceeding 1.50 Sqm but not exceeding 4.00 Sqmeach with shutters (without taking off shutters from the frames) and removing from site complete all as specified. (The disturbed surface during taking down shall be made good by the contractor without any extra cost for fixing new one ofany description. No extra cost is permissible for the material and labour for making good the disturbed surface, complete all as specified and directed. 3 Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed. 4 Demolition of brick work or stone / bouldermasonry includingall quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed. 5 Demolitionof Stone slabs and tiles of any description or thickness in floors, aprons etc.complete all as specified and directed. 6 Taking up or down 15 mm bore steel water tubing and connection, including cleaning for refixing or removal to store complete all as specified and directed. 7 Taking up or down 20 mm bore steel water tubing and connection, including cleaning for refixing or removal to store complete all as specified and directed. 8 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed. 9 S & F of solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain coloured PVC sheet reinforced with mild steel square tube as per specification and drawing given on MES schedule Part – II (2010) complete all as specified and directed. 10 S & F of factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles) with particle board core an 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. 11 S & F of 200mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. 12 S & F of 300 mm long (Length of bolt) aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy complete all as specified and directed. 13 S & F of 150 mm long anodised aluminium handle, cast type complete all as specified and directed. 14 S & F of 100 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed. 15 Material & labour for RCC chajja/ fascia/ parapet repair by using following steps:-(a) Removal of existing concrete alongwith loose damaged and cracked concrete/ over concrete from chajjas etc, exposing corroded steel reinforcments upto a depth of 10mm minimum behind the reinforcement by chipping/ hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic hippers including high pressure water jetting to chipped concrete and reinforcement all as directed by Engineer-in-Charge Hard concrete shall not be removed. However if the rebar is corroded, concrete around it shall be removed.(b) Cleaning the surface of reinforcment bars from dust by using wire brushes and dry cloth and applying FOSROC Rebakleens RR- Rust Remoer or equivalent using small brush and allow to react it for 16-24 hrs.(c) Providing and applying two coats of FOsroc Nitozinc Primer- two component, zinc rich epoxy, anti- corrosive protective coating or equivalent by brushes to the exposed and cleaned rebars with an interal of 45 minutes to 1 hour @ 40 microns DFT/ Coat and allowed to completely dry for 24 hours all as directed by Engr-in- Charge.(d) Cleaing the concrete surface thoroughly once again using wire brush and applying one liberal coat of Fosroc Nitobond EP- two component Epoxy bonding agent or equivalent to the parent concrete with brush.(e) Proving and appying 50mm thick Renderoc SP-40- or equivalent Polymer modified single component, alkaline resistant fibre reinforced. thixotropic, cementitious patch repair mortar after mising of Renderoc SP 40 orequivalent with recommended qty of water using slow speed drill fitted with mixing paddle and then applying the same to prepared surface and finishing the same with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface all as directed by Engr-in-Charge.Note: Item rate is inclusive of all materials, labour tools and plants scaffolding and transportation etc complete as per specifications and as directed by Engr -in- Charge. 16 M & L for providing cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in bed blocks complete all as specified and directed. 17 S & F of pressed steel frames of size 125mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate., complete all as specified & directed. NOTE : PCC for filling of hollow portion shall be measured and paid for separately. 18 M & L for providing plain cementconcrete type C-0, 1:3:6, (using 12.50 mm graded stone aggregate), as infilling of pressed steel door frames/chowkats complete all as specified and directed. 19 S & F of 35mm thick 2ndclass hard wood (Sal/Hollock), glazed and skeleton shutters (factory made), open rebated and prepared to receive glass or gauge etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., size of members of shutters as specified in clause 8.24 (a) of SSR Part-I, complete all as specified and directed. 20 S & F of 30 mm thick flush shutter solid core construction with block board core and plywood face panels commercial type on both faces complete all as specified and directed. 21 S & F of 300 mm mild steel ordinary rat tail, rod pattern springs including roller and roller plate complete all as specified and directed. 22 S & F of 150 mm size (Overall length of cover plate) floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and directed. 23 S&F in repair drapery fancy type curtain rod shall be 20 mm dia of stainless steel rod, including all fixing arrangement complete all as specified and directed. 24 M&L for Coloured non skid ceramic tiles 300x300x7to 8 mm thick (pattern consists combination of two or more tiles) laid in floor over and including 15mm thick screed bed or bedding layer of cement 1:4 set and jointed in neat cement slurry and pointed in white cement to match the colour of tiles, (The colourshade and pattern shall be approved by GE and no extra cost shall be allowed for removing and refixing and necessary cutting of door etc in any during execution of work) complete all as specified and directed. 25 M&L for Coloured glazed ceramictiles 450x300x7 to 8 mm thick laid in vertical surface/skirting and dado over and including 10 mm thick rendering in cement 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, (The colourshade and pattern shall be approved by GE and no extra cost shall be allowed for removing and refixing and necessary cutting of door etc in any during execution of work) complete all as specified and directed. 26 M & L Non - skid Ceramic joint free colouredtiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white orcoloured cement to match over and including 15mm thick screed bed or bedding layer of cement 1:4 complete all as specified and directed. 27 M & L Non - skid Ceramic joint free colouredtiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white orcoloured cement to match over and including 10mm thick backing coat in cement 1:4 complete all as specified and directed. 28 Cutting chases, pinning through brick wall in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, lintels, shelves etc, and cutting chases for concealed water tubing or concealed conduit wiring etc, and making good on brick walls, cutting not exc. 10 cm in girth complete all as specified and directed. 29 S&F 15mm nominal bore of pipe in walls, and ceiling or laid in floors, jointing and testing galvanised mild steel water tubing “medium grade” with and including all fitting (such as bends, elbows, tees, short pieces connectors, back nuts, diminishing pieces, capas, plugs and union etc) complete all asspecified and directed. 30 S&F 20 mm nominal bore of pipe in walls, and ceiling or laid in floors, jointing and testing galvanised mild steel water tubing “medium grade” with and including all fitting (such as bends, elbows, tees, short pieces connectors, back nuts, diminishing pieces, capas, plugs and union etc) complete all asspecified and directed. 31 S&F 15 mm bore angle stop valve cast copper alloy,CP with capstan heads, fancy type any colour high pressure screwed for iron pipe and fixed complete all as specified and directed. 32 S & Fof 15 mm bore fancy type, chromium plated stop valve, with long shank and cup (Concealed Type) cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed. 33 S & F in repair 15 mm bore chromium plated,fancy type bib tap, cast copper alloy with capstan heads,screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. 34 S & F in repairs water closet vitreous china squatting pan ‘Orrisa’ pattern size 580 X 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe, anti-syphonic pipe etc. with and including setting the trap and pan in lime concrete bedding (one lime, two sand or surkhi and 5 aggregate) minimum 150 mm thick alround and finished just below level of rim of pan to receive the floor finishes complete including making good floor complete all as specified and directed. 35 S & F of vitreous china, wash hand basin, flat back, white of size 550mmx450mm including brackets, brass CP waste coupling 32mm dia with long screwed shank and fly nuts, chain and plug, porcelain stopper including cutting for and pinning in ends of brackets or erecting stand, fixed in repairs, complete all as specified & directed 36 S & F in repairpolymer white (polypropylene Delrin and ABS) low level flushing cistern 10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, flush pipe, brass screws, handle etc complete having BIS description mark with IS: 7231 with and including 32 mm bore PVC flush pipe of suitable length complete all as specified and directed. 37 S & F in repairs 450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed. 38 S & F of 15 mm bore pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered HOT or COLD’ with long screwed shank and fly nuts, screwed for iron pipe complete all as specified and directed. 39 S & F of chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union size 125 mm complete all as specified and directed. 40 S & F of 100 mm dia chromium plated grating doom with waste hole complete all as specified and directed. 41 S & F of 110 mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed. 42 S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to wall /floor, i ncluding dismantling existing pipes of any descrsiptioncomplete all as specified and directed. 43 S & F of 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to wall /floor, i ncluding dismantling existing pipes of any descrsiptioncomplete all as specified and directed. 44 S & F of 110 mm bore PVC (SWR) bend any radiuswith or withexcess door complete all as specified and directed. 45 S & F of 75 mm bore PVC (SWR) bend any radiuswith or withexcess door complete all as specified and directed. 46 S & F of 110mm bore PVC (SWR) Slottedvent cowl complete all as specified and directed 47 S&F 600mmx450mm bevelled edge mirror of selected quality glass 4 mm thick, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. 48 S & F of Factory made box type steel windows for desert coolers, comprised of tubular frame and shutters made out of 1.25mm thick MS sheet tube with double side shutters (Wire Gauged shutter and Glazed Shutter), side hung shutters with MS handles and MS stays dovetailed or welded including 02 nos MS Tower Bolt 150mm long for each leaf, 8 mm square guard bars at spacing as shown in drawings, MS flat iron frame work, MS hinges, tarred hold fast,PCC 1:2:4 type B1 as in bed of hold fast, 01 No. per leaf of stopper of 100mm size, one coat of red oxide zinc chrome primer etc, complete all as specified and shown as drawing No. CEPZ/TD-032/13 sheet 1/2 to 2/2.NOTE : a). Wire cloth and Sheet glass shall be measured and paid seprately under respective items.b). Rate of both type of shutters is inclusive in the quoted rate. 49 S & F steel ventilator with top hung shutter including hinges, steel peg stay, complete including one shop coat of red oxide zinc crome primer, complete all as specified & directed. complete all as specified and directed . 50 S & F repairsoapdish brass chromium plated, fancy type fixed to wallwith rawl plugs andchromium plated brass screws complete all as specified and directed. 51 S & F in repair20 mm dia brass chromium plated tubular towel rail D type 60 cm long between flanges, including one pair of fixing brackets complete all as specified and directed. 52 S & F of 500 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part – I and hoisted, fixed in position, including dismantling of existing tank of any description and S& F 20 mm ball PTMT Ball valve high pressure with epoxy coated aluminium rod andhigh density plastic abll screwed foriton pipe,complete all as specified and directed. 53 S & F 20 mm bore gun metal globe or gate valve, with iron wheel head, quarter tun type, screwed both ends for iron pipe complete all as specified and directed. 54 M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed. 55 Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed. 56 M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth with neru finish to plaster work complete all as specified and directed. 57 M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with 10 mm thick in cement mortar 1:6 and 5mm thick cement mortar 1:4 finished even and smooth without using extra cementusing integral water proofing compound as per manufacturer,s instructions , complete all as specified & directed. NOTE:-Integral water proofing compound shall be measured & paid seprately. 58 Supply only water proofing compound ( (Liquid)complete all as specified. 59 M & L for 75 mm thick cement concrete 1:3:6 type C-1, using 20 mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm thick joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed. 60 M & L for complete removal of old finishes from walls by scrapping, rubbing down, with sand paper to have even and smooth surfaces and applying two coats of oil bound distemperover a coat of 3 mm thick wall care putty with alkali resistant primingpaint, complete all as specified and directed.NOTE:-The work will be carried out upto triple storey buildings and the cost of scaffolding is also included in this items 61 M & L for preparing newlyplasteredwall surfaces and applying two coat of oil bound distemperover a coat of 2 mm thickbirla wall care putty complete all as specified and directed. 62 M & L for preparation of new or previously untreated wooden surfaces exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 63 M & L for preparation of steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. 64 M&L for preparing newly plasteredwall surfacesup to 10 metre heightand applying two coats of‘Weather coat’over one coat of primer, using mechanical vaccume machine complete all as specified and directed. 65 M&L for complete removal of existing treatment from walls upto 10 metre height, finishing the undulated surfaces bu cement putty andapplying two coats of‘Weather proof paint’over one coat of primer, using mechanical vaccume machine complete all as specified and directed.Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix AB on page no. 95of tender documents as per Sch A Note No 19 Page No 17). Non uploading of MOU by the bidder shall lead to rejection of bid during technical evaluation. 66 S & F of 3mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with beads in square not exc. 0.5 sqm in each pane complete all as specified and directed. 67 Excavation in trenhes, not exceeding 1.5m wide and exceeding 1.5m depth and not exceeding 3m for foundation manholes, etc and getting out in any type of soil complete all as specified and directed. 68 S & F of 3 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane with oil putty or fixed with beads complete all as specified and directed. 69 S & F of stainless steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixedwith tinned tacks, or galvanised wire staplescomplete all as specified and directed. 70 Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. 71 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. complete all as specified and directed. 72 M & L for 75 mm thick cement concrete 1:4:8 type D-2, using 40 mm graded stone aggregate as in subbase complete all as specified and directed. 73 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type soil complete all as specified and directed. 74 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed. 75 Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed. 76 Demolition and breaking up drain pipes of any size (salt glazed stoneware,PVC/ AC or reinforced concrete) set in cement mortar complete all as specified and directed. 77 M & L for cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in bed to drain pipes of 150 mm bore including packing under and haunching against the sides of pipeafter they are laid and tested complete all as specified and directed. 78 M & L for 150 mm dia DWCPE (SN8) HDPE pipes, laid in trenches on PCC bed, jointedas per manufacturers instructions, complete all as specified & directed.Note : Earthwork, PCC bed/ haunching shall be measured and paid for seperately under respective items. 79 Demolition ofreinforced cement concrete in any position and any description including cutting of reinforcement bars to facilitate demolition complete all as specified and directed. 80 M & L for providing plain cement concrete, type D-2, 1:3:6 (using 40 mm graded stone aggregate) as in sunken, filling and mass concrete complete all as specified and directed. 81 M & L for providing plain cementconcrete type B-1, 1:2:4, (using 20 mm graded stone aggregate), as inbenching,water throughtsetc and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. 82 M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-0, using 12.50 mm graded stone aggregate, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones,bed platesetc and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed. 83 M & L for providing pre-cast cement concrete landing, cover slabs, chullah hoods, chajjas, shelves and similar items with plain faces in cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate and setting in cement mortar 1:6 complete all as specified and directed. 84 M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia securing with clips complete all as specified and directed. 85 M & L for providing PCC complete in cement concrete 1:2:4 type B-0, using 12.5 mm graded stone aggregate as in roof padding, complete all as specified and directed. 86 Complete removal of the existing roof treatment including brick tiles and mud phuska (if existing) of any description etc including grubbing up of tree roots,preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust with water complete all as specified and directed. Treatment complete all as specified & directed :- 87 M & L Applying 1st course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed complete all as specified & directed 88 M & L Applying 2nd course of applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm including cleaning surfaces complete all as specified & directed 89 M & L Applying 3rd course of APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) land on primed surface by forced application complete all as specified & directed 90 M & L Applying 4th course of a coat of blown type bitymen of grade 85/25 heating to a working temperature of 180 degree and applied complete all as specified & directed 91 Taking down shutters of any description exc. 1 sqm and not exc. 2 Sqm each, complete all as specified & directed. 92 S & F of aluminum (die cast) body door closer hydraulically regulated,designation No. 3,universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kgand fixed complete all as specified and directed. 93 S & F for Vitrified lightshade Ceramic tiles 9-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer of cement 1:4complete all as specified and directed. 94 S & F for Vitrified light shade Ceramic tiles 9-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as on vertical surface of wall such as skirting, dado, riser etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering of cement 1:4 complete all as specified and directed. 95 M & L Non - skid joint free Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer of cement 1:4 complete all as specified and directed. 96 M & L for 20 mm thick granite (of any type and shade) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4)including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including necessary cutting, grinding, rubbing, polishing rounding to exposed edgesand laid over 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed. 97 S & F in repair vitreous china wash down water closet pan (Pedestal pattern)and trap (excluding) fixing bolts,flushing cistern and flush pipe including connection to drain (or outgoing pipe)including plastic seat cover suitable for water closet pedestal pan, coloured closed pattern with flat bottom and cover and mid steel chromium plated or aluminium hinges devices with and includingbrass chromium plated standard quality jet with nozzle 1500 mm long PVC pipe etc complete all as specified and directed complete all as specified and directed. 98 S&F in repair brass CP basin mixer for mixing hot & cold water screwed down for15 mm dia bore GI pipe complete all as specified and directed. 99 S&F in repair glass corner shelf fancy type, 250x250 and 5.5 mm thick fixed with brass basket and screwed complete all as specified and directed. 100 Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed. 101 S&F for suspended false ceiling system using 4mm thick high pressure steam cured fibre cement pre-primed textured varient E-board (classic), ISI marked, conforming to IS:14982-2000 over and including GI snap grid frame workfor false ceiling, grid size600 x 600 mm with GI angle of size 25x25mm, main runner ‘T’ of size 25x40mm, secondary runner ‘T’ of size 25x30mm with 3 mm GI wire with butterfly clips as hangers for leveling, fastners, supports, plugs to walls/joists etc , hangers to be fixed with approved rawl plug, level adjusters and screwsa etc, last hanger at the end of each runner shall not be greater than 450mm from adjacent wall all as per manufacturer’s Instructions including making holes, cutting chasis and making good existing walls in cement mortar 1:3 or PCC 1:2:4 type B1, complete all as specified anddirected. Note :- a)All steel members shall be hot dipped galvanised with zinc coating not less than 120 gm/sqm. 102 M & L for preparation of old wood surfaces exc. 10 cm width or girth and applying one coats of synthetic enamel paintcomplete all as specified and directed. 103 M & L for preparation of old steel surfaces over 10 cm width or girth and applying one coats of synthetic enamel paintcomplete all as specified and directed. 104 M&L for capilary rise treatment of walls as following :-Base coat: Berger HS Latex plus (or equivalent)Consumption base coat: 0.3 kg/m2Second and Third coat: Latex sheild 2K (or equivalent)Consumption top coat: 3 kg/m2System requirements: density: 2.00 kg/ltrCompressive strength: 0.5 N/mm2 Note :-The concerned items should be executed by OEM authorized applicator after signing of MOU (format attached as Appendix AB on page no. 91of tender documents as per Sch A Note No 19 Page No 17). Non uploading of MOU by the bidder shall lead to rejection of bid during technical evaluation. 105 M & L for Chequered cement concrete tiles 300mm x 300mm x 25mm thick,set, jointed and pointed in neat cement slurry in floors with and including15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed. 106 E/M Portion 107 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed. 108 Taking down carefully distribution boards/wooden bard, switch fuse units, steel enclosure for MCB/MCBs of any type and removing from sitecomplete all as specified and directed. 109 Taking down carefully existing sub main wiring complete of any size and capacity, making good the disturbed surface, complete all as specified and directed. 110 M&L for point wiring one light / fan/ bell/Exhaust fan point controlled by one way switch(concealed type) complete with multistranded copper conductor flame retardant low smoke (FRLS)1.5 Sqmm size PVC insulated unsheathed cable 1100 volts grade drawn through with and incl medium grade duty concealed PVC conduit ISI marked not less than 20mm dia including conduit fittings and accessories such as socket,elbow,junction box, bell mouth,bend, reducer etc complete incl cutting chases inexisting walls of any description built in cement mortar and making good the disturbed surfaces in cement mortar (1:4)and finishing the surfaces to match with existing surfaces and finish with using sunken type pressed steel terminal boxes of required sizes (200mmx300mm) of not less than 1.63 mm thick concealed type factory made and factory painted with top cover of 3 mm thick plastic laminated sheet fixed with brass screws washers with all accessories including single core multi stranded copper conductor1.5 Sqmm size PVC insulated unsheathed cablegreen in colouras earth wire to common earth andconnected to earth dolly drawn in same conduit complete all as specified and directed. 111 All as per item No 108 but for one fan point controlled by one piano switch completeallas specified and directed. 112 All as per item No 108 but for one lightpoint controlled by two way switch completeallas specified and directed. 113 All as per item No 108 but for one bellpoint controlled by one bell push completeallas specified and directed. 114 All as per item No 108 but for 3 pin socketoutlet 5 amp on same board completeallas specified and directed. 115 All as per item No 108 but for 3 pin socket outlet 5 amp on independentboard completeallas specified and directed. 116 All as per item No 108 but for one 15 Amp 3 pin switch socket outlet, idependent with 2.5sqmm single core multi stranded odpper conductor cable(FRLS) alongwith 2.5 sqmm continuous PVC insulated unsheathed single core multistranded opper conductor (FRLS) cable for earth continuity wire complete all as specified and directed.) 117 S&F in repairs switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified and directed. 118 S&F in repairsSwitch socket outlet combination 2 in 1,3 pin, 5 Amp, flush type universal type, 240 volts complete all as specified and directed. 119 S&F repairs Switch socket outlet combination 2 in 1,3 pin, 5 and 15 Amp, piano flush type universal type, 240 volts complete all as specified and directed. 120 S&F in repairs Ceiling rosesurface bakelite three terminals 240 volts complete all as specified and directed. 121 S&F electronic fan regulator, 100 watt, (5 stepped type), 240 Volt for 1200/1400 sweep AC ceiling fan complete all as specified and directed. 122 Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rosecomplete all as specified and directed. 123 Supply and fixing LED lights fitting 1x 10W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rosecomplete all as specified and directed. 124 Supply and fixing factory made epoxy powder coated distribution board, SPN, 4 ways with metal door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for one SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed . 125 Supply and fixing factory made epoxy powder coated distribution board, SPN, 8 ways with metal door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for one SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed . 126 Supply and fixing factory made epoxy powder coated distribution board, SPN, 12 ways with metal door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for one SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed . 127 Supply and fixing in replacementminiature circuit breaker (MCB) SP-06 TO 32 Amp ,10KA, 240 volts complete all as specified & directed. 128 Supply and fixing in replacementminiature circuit breaker (MCB) SPN-32 Amp, 240 volts complete all as specified & directed. 129 Supply and fixing in replacementminiature circuit breaker (MCB) SPN-63 Amp, 240 volts complete all as specified & directed. 130 Supply and fixing in replacementMCCB 415 volts, 16 KA 4 Pole 125 Amps complete all as specified & directed. 131 Supply and fixing single core PVC insulated unsheathed multistranded coper conductor cable 1 Sqmm, 1100 volts ISI marked drawn through existing point wiring complete all as specified & directed. 132 M&L forsub main wiring with 2 Single core PVC insulated unsheathed FRLScable 1100 Volts grade heavy duty copper conductor multistranded of size 2.5 Sqmm (nominal area) drawing in and including 25 mm dia or higher medium dutyPVC concealed conduit and conduit accessories and fittings. including one single core green colour PVC Insulated unsheathed FRLS cable copper conductor multistranded of size 2.5Sq mm as earth wire upto common earth and connected to earth dolly including cuttingchases pinning in making good to facing and pointing incement mortar 1:3, and making good disturbed surface, complete all as specified & directed. 133 M&L forsub main wiring with 2 Single core PVC insulated unsheathed FRLScable 1100 Volts grade heavy duty copper conductor multistranded of size 6.0 Sqmm (nominal area) drawing in and including 25 mm dia or higher medium dutyPVC concealed conduit and conduit accessories and fittings. including one single core green colour PVC Insulated unsheathed FRLS cable copper conductor multistranded of size 6.0 Sq mm as earth wire upto common earth and connected to earth dolly including cuttingchases pinning in making good to facing and pointing incement mortar 1:3, and making good disturbed surface, complete all as specified & directed. 134 M&L n repair for earthig complete with galvanized steel earth plate 600x600x6mm thick buried vertically in groundto depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to GI earth lead wire 4 mm dia by means of bolts, nts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthig lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1 (using 20mm di stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dia and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) and pouring extra Clay Soil of qty not less than one cubic meter into the earth pit and also removal of excavated soil not less than 50 mtr from the earthing place all as specified and directed and tested on completion. including testingall as specifed and directed by E-in-Charge. 135 Taking down ceiling fan 1200 mm sweep complete cleaning the grease oil etc spray painting with two coat of synthetic enameled paint over a coat of primer including replacement of bearing, capacitor, cotton pin, rubber coal, MS nuts bolts washer, connector prewired from connector from ceiling rose with twin core flexible copper conductor cable 24/0.02 refixing in positioncomplete of reading completeall as specified and directed 136 Taking down Exhaust fan300/450 mm sweep complete cleaning the grease oil etc spray painting with two coat of synthetic enameled pain tover a coat of primer including replacement of bearing, capacitor, cotton pin, rubber coal, MS nuts bolts washer, connector prewired from connector from ceiling rose with twin core flexible copper conductor cable 24/0.02 refixing in positioncomplete of reading completeall as specified and directed 137 S&F of Intergral LED security light luminaire 60 W LED, 230 volts made up of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, luminaire,mounted on & includingGI bracket made out of 50mm bore medium grade pipe of 1.50m length, bent to required shape,fixed on PCC/Steel pole with 02 Nos. clamps of flat iron (40 x 6mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer, making connection with PVC copper conductor cable of 1.5 sqmm and taking down old unserviceable light fitting of any type/size, with IP-65/66, complete all as specified & directed. 138 S&F of Intergral LED security light luminaire 35 W LED, 230 volts outdoor type, made up of pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with suitale size and length of 1.5 Sqmm copper conductor with impact and corrosion resistant including thermal management in multiple optics, complete with IP 65/66 protection complete all as specified & directed. 139 S&F in repairs Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittingscomplete all as specified and directed. 140 S&Fin repairs Bell Push flush rype piano 5 Amp complete all as specified and directed. 141 S&Fin repairs Bell multi music 230 volt, AC single polecomplete all as specified and directed. 142 S&F energy efficientLED bulk head luminaire, 1x9/1x10 watt, including LED light driver holder conneccting up with three core flexible copper conductor cable of suitable sizecomplete all as specified and directed. 143 S&F ofexhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250mincluding provision of three core flexiable copper cord of size 0.75 Sqmm PVC insulated overall sheathed, of required length from ceiling rose or connector to exhaust fan for connection, complete all as specified & directed. 144 Taking down electric energy meter single phase any size or type from the existing site and refixing the same at the same place after carrying out necessary repair work in building and makigthe surface good to match with existing surface complete all as specified and directed. 145 M & L for cutting of suitable size of holes for 250 mm exhaust fan in wall and grouting of nuts and bolts in wall and making good to match with existing walls complete all as specified and directed.