Addn/Altn Of Bldg No P-34 Office Complex Of Stn Hq Raipur At Naya Raipur Mil Stn As Per Boq; 1 Surface excavation n.exc 30 cm deep and getting out in soft/ loose soil complete all as specified and directed. 2 Demolition of Reinforced Cement Concrete asin Column,.Roofs, floors (other than ground floors), beams staircases, landing, chajjas, and similar suspended work complete all as specified and directed. 3 Demolition of brickwork built in cement mortar with all quinces the cleanly etc complete all as specified and as directed. 4 Excavation in trenches not exceeding 1.5m wide and not exceedinf 1.5m in depth; for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth andgetting out in soft/loose soil.complete all as specified and directed. 5 M & L Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. 6 M & L for RCC M-25 (Design mix) (using 20mm graded stone aggregate) as in foundation including rafts, footing, foundation beams, plinth beams, bases for columns, etc and mass concrete complete all as specified and directed. 7 Formwork to flat sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits(if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. 8 M & L for RCC M-25 (Design mix) (using 20mm graded stone aggregate) as in Columns, pillars, piers, posts and struts, etc and mass concretecomplete all as specified and directed by Engineer-in-Charge. 9 Formwork to Square,rectangular or polygonal rough surface of concreteof sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. 10 M & L for RCC M-25 (Design mix) (using 20mm graded stone aggregate) as in beams, cantilevers, bressumers, lintels over 1.5m span etc. complete all as specified and directed. 11 Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.c complete all as specified and directed 12 M & L for RCC M-25 (Design mix) (using 20mm graded stone aggregate) as in Chajja completeall as specified and directed. 13 Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed. 14 M & L for RCCM-25 (Design mix)(using 20mm graded stone aggregate) as in slabs supported on walls etc completeall as specified and directed 15 Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge. 16 Returning, filling in of soft/loose soil including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. 17 Removing excavated materialn exc 50mdepositing where directed at a level exc 1.5m above the stating point complete all as specified and directed by Engr in Charge . 18 S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed. 19 Ditto all as item No 21 herein before but 5 mm dia and over upto and including 10mm dia in stirrups, spacer and binders. 20 M & Lbrick work with modular size fly ash bricks straight or curved on planexc 6 m mean radius built in cement mortar 1:6complete all as specified and directed. 21 M & L 40mm thick PCC 1:2:4 damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed. 22 M & L for rendering 15mm thick in CM 1:4 on brick or concrete surface,finishing even and smooth without using extra cement but using water proofing compound complete all as specified and directed. 23 M & L rendering 10mm th plaster in CM 1:6 on fair faces of brick or concrete surfaces(internal walls) finished fair and even without using extra cement complete all as specified and as directed. 24 M & L for rendering 5mm thick in CM 1:3 onconcrete surfaceof ceiling finishing even and smooth without using extra cement complete all as specified and directed. 25 M L forMoorum / Red bajri filling in floors or pavings, laid in layers n.exc15 cm thick spread levelled and rammed incl watering etcall as specified & directed. 26 M & L Hard core of gauge n.exc 63 mm, deposited, spread, levelled in layers not exc 15 cm thick, watered and well rammed to a true surface complete all as specified and directed by Engineer-in-Charge. 27 M & L 25 mm thick PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in floors finished even surface. complete all as specified and directed 28 M & L for 75mm thick ,cement concrete 1:3:6 type C2, using 40mm graded stone aggregate as in plinth protection finished the surface even and smooth using extra cement complete all as specified and directed. 29 M & L for forming contraction (dummy) joint 65mm deep X 10mm wide filled with sealing compoung Grade A, complete all as specified and directed. 30 M & L Sand filling under floors or in foundations including watering and consolidation. complete all as specified and as directed. 31 M & L for 100mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate assub basecomplete all as specified and directed. 32 M & L for vitrified ceramic tiles 10mm thick Square/rectangular)polished light shed, area of each tiles not exceeding 0.36 sqm, as in floors etc. set and jointed in neat cement slurry over 20mm thick Screed bed in CM 1:4 and pointed in white or coloured cement to match all as specified and as directed 33 M & L for vitrified ceramic tiles 10mm thick (square/rectangular)polished light shed, area of each tiles not exceeding 0.36 sqm, as in wall/ Skirtiing etc. over 10mm thick plaster in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed 34 M & L three coats of white wash on new plastered ceiling surface including preparation of surfaces complete all as specified anddirected 35 M & L preparing surface newly plastered surfaceon wall applyingtwo coats of Cement base paint over a coat of primer complete all as specified and directed. 36 M & L for three coat of white washing in internal wallincluding preparation of surfaces complete all specified and as directed. 37 M & L for prepration of old decorated plastered surfaceor un plastered surfaceincluding cornices etc and applying two coat of white wash on walls complete all as specified and directed by Engineer-in-Charge. 38 M & L for one coat Cement base paint on old plastered surface including complete removal of existing tratment washing down and rubbing and prepration of surface all as spcefied and directed 39 M & L preparation of newly wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of white / tined synthetic enamel paint over one coat of pink primer all as specified and directed. 40 M & L two coats of synthetic enamel pain on newly steel surfaces includingcoat of red oxide primer complete all as specified and directed. 41 M & L for two coat of oil boundemulsion distemper incl prepration of new plastered surface of wall over a coat of primer and applyingover plastered surface to prepare the surface even and smooth complete all as specified and as directed. 42 Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. 43 Taking down/removing the existing roof treatment including backing and dispose off exc 100m as directed complete all as specified and directed 44 M & L for brushing neat cement slurry with 3.0 Kg./Sqm over roof slab complete all as specified and directed. 45 M & L for 25mm thick (average thickness) PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate)as in roof padding for filling uneven surface and finished fair / even complete all as specified and directed 46 M & L for cleaning the top surface of concrete and providing water proofing treatment with polymeric water proofing memberane not less than 3.0 Kg/Sqm such as M/S Tikki tar /STP/ SUPER HYDRA-310 /Equivalentof approved make test to be carried out from national test hous/Govt lab ,for all makes, including priming the surface by applying bituminous primer @ 0.3 Kg/sqm andapplying the surface by blown grade bitumen 85/25 @ 1.20 Kg/Sqm &applyingwater proofing memberane( with 10 cm. overlaps )andapplying the surface by blown grade bitumen 85/25 @ 1.20 Kg/Sqm and painting bituminuos aluminium paint @ 100gm/sqmcomplete all as specified and directed. 47 Supply only water proofing compound of approved make. completeall as specified and directed. 48 M & L for brick work with modular size fly ash bricks straight or curved on plan to any radius half brick thick wall built in CM 1:4 complete all as specified and directed by Engineer-in-Charge. 49 Taking down chowkats or frames with shutters (without taking off shutter from frames) not exc 1.5 Sgm each and making good of disturbed surface match the existing surface all as spcefied and directed 50 Ditto - all as per item No 49 herein before butexc 1.5 Sgm but not exc 4 Sgm each. 51 S&F 125x60mm size ofpressed steel frame for door with one or more rebates including necessary fixing lugs, lock striking plates,hinges,hold fast(40x3mm) etc. complete size /profile of frame as per IS complete all as specified and directed. 52 S&F 105x60mm size ofpressed steel frame for door with one or more rebates including necessary fixing lugs, lock striking plates,hinges,hold fast(40x3mm) etc. complete size /profile of frame as per IS complete all as specified and as directed. 53 M & L for aluminium powder coated Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified. 54 M & L for aluminium powder coatedAnodised aluminium window and ventilator shutters,sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed by Engineer-in-Charge. 55 Sheet glass 3mm thick, ordinary quality and glazing fixed with aluminium section in squares not exceeding 0.5Sqm in each pane complete all as specified and directed 56 S&F galvanised steel wirecloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mmin repairs complete all as directed at site. 57 Aluminium handles, cast type anodised 150mm size complete all as specified and directed 58 S&F aluminium anodised barrel tower bolt150 mm. completeall as specified and directed 59 S&F MS 100 mm size butt hinges medium wt. of cold rolled complete and all as specified and directed 60 S & F 250mm long aliminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast alliminium allow and fixed sliding door bolts plate type extanlled black bright bolt not less than 12mm dia with and including a minimun 06 bolts and not less than plate and two on staple plate complete all as specified and directed. 61 S & F for 2nd Class Hardwood in Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints complete all as directed. 62 M & L for PCC 1:3:6 type C-1 using 20mm graded stone aggregate for hold fast blocks, including necessary form work for rough finished surfaces etccomplete all as specified and directed. 63 M & L for 35mm thick 2nd class HW rail and style plain framed, factory made paneled shutter (one panel) without interlocking rail and 12mm veneered particle board with commercial veneering on both faces the size of rail and style as per IS -1003 (Pt-I)kiln seasoned and chemically pressure treatedcomplete all as specified and directed. 64 M & L for 30 mm thick, 2nd class hard wood , glazed & skeleton factory made shutters, open rebated & prepared to receive glass, gauze etc. (without sash-bars), edges of framing plain, chamfered or rounded fitted with cut and metred beads for securing glass etc., sizes of members of shutters as specified in SSR Part-I, Section-8, clause 8.20(a) complete all as specified and directed. 65 M & L for painting to new wood or wood basedsurfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, priming with pink primer (one coat) finished with two coats of synthetic enamel paint complete all as specified. 66 S&F factory made steel windows with side hung shutters including box type hinges with steel handle and steel peg stay complete with glasing bars dovetail.ed or welded all as specified and directed. 67 Ditto - all as per item No- 66 here-in before but without glazing bars 68 S&F factory made steel ventilators with top hung shutter including hinges,steel peg stay complete all as specified and directed. 69 S&F frame work such as grills, grating etc with ends of bars shouldered and or rivetted or forged into spikes, framed guard bars, barred iron doors, ladders etc and similar wks conforming to Fe-290 Gd E-165 complete all as specified and directed. 70 S&F for Bands, straps, supports or stays for rainwater, ventilating pipes,including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed by Engineer-in-Charge. 71 M & L fortwo coats of synthetic enamal paint over red oxide on new steel surfaces including preperation ofsurfaces complete all as specified and directed 72 S&F in repair 20 mm dia decorative type curtain rodwith rings and brackets complete all as specified and directed. 73 S&F300mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and direcetd. 74 M & L for 40mm thick PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in flooring including finishing the top surface even & smooth, without using extra cement complete all as specified. 75 M & L for cutting V section to cracks in existig roof or terracing/brick wall including cleaning, and grouting with cement sandslurry1:3 complete all as specified 76 Supply & fixing E board (Everest make) 605 x 605 x 4 mm thick white prelaminated set & embosed, reinforced, designer ceiling board tiles of approved texture fixed at all height laid on hot dipped galvanised iron imposed grid with 24 mm wide T-section exposed flanges which shall be powder coated, white,.the frame work shall comprises of main runner made from 0.33 mm thick galvanised steel sheet and of size 24 x 32 x 300 mm and spaced at 1200 mm center to center fixed to be structural soffits by approved hangers at 1200 mm rawl center, hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level and fasteners and screws etc., the last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall, flush fitting of 120 mm long cross tee (with double stiching) to be interlocked between main runners at 600 mm center to center, size 1200 x 600 mm modules, cross tee longer than 600 mm to be supported independently on 600 x 600 mm moduler to be formed by fitting 600 mm long cross tee centrally between the 1200 mm cross tee. Tee, perimeter wall angle shall be of 0.45 mm thick GS sheet of size 19 x 19 mm and 300 mm long of white colour all as per manufacturers instructions complete all as directed. 77 Material and labour forpoint wiring complete with and includingsingle core PVC FRLSinsulated unsheathered flexible bright concealed multi stranded copper conductor cables 1.5 Sqmm (22/.30mm) 1100 Volts grade drawn through and including heavy grade PVC rigid concealed condiuts 20mm or higher dia as reqd at the site. totally concealed in walls / floors /ceilling including all conduit accessories /fittings /junctions boxes /inspectionscover etc of heavy grade , ISI marked and sunk terminal sheet top cover, fixed flush with wall surface by means of brass screws and sunk/cupwasher, for mounting of switches , sockets , fan, regulators etc, including 1.5 Sqmm (22/.30mm) PVC insulated, unsheathed fliexible multi stranded copper conductor cable as continuous earth wire connected to metallic bodies of luminaries/fans etc, at one end and to common earth dolly at other end, all as specified , directed and shown on drawings.complete all as specified for One light point controlled by one switch 78 Ditto all as per item No 77 herein before but One Fan point controlled by one switchlight point 79 Ditto all as per item No 77 herein before but One socket out let 5 pin 5 Amp on same board 80 Ditto all as per item No 77 herein before but One socket out let 3 pin 5 Amp on independent board 81 Ditto all as per item No 77 herein before but using 4.0 Sqmm cable for one 15 A socket outlet point controlled by one switch on independent board with and including 2.5 Sq mm PVC insulated, unsheathed copper conductor cable as earth continuity conductor 82 S & F modular switch 1 way 6A 1 moduleMake Legrand/ Crab tree/ Philips complete all as specified 83 S & F modular socket 6A 2/3 Pin combined 2 module . Make Legrand/ Crab tree/ Philips complete all as specified 84 S & F modular switch 1 way 16A 1 module . Make Legrand/ Crab tree/ Philips complete all as specified 85 S & F modular socket outlet 1 way 6/16 Amps2/3 pins combined 2 module complete, Make Legrand / Crab tree, Philips complete all as specified 86 S & F for modular fan regulator 120W, 2 module ISI marked, . Make Legrand/ Crab tree/ Philips complete all as specified 87 S & F Modular/ metalflush box 8 module complete all as specified 88 S & F modular white cover plate and frame 8 module complete all as specified 89 S & F for power unit mini modular MCB box with mini MCB 20 Amps SP with ISI plug top with box for connecting ACs upto 2 ton complete all as specified and directed. Make Ancho UNO Code No 98488 or equivalent in Havells/Legrand/Cona complete all as specified 90 Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified 91 Supply and fix building security light of35/36 watt IP 65 watt,LED die casting aluminium with LED street optic lenses ,efficacy of skyline plus is upto 120lm/w, with pea nut lenses LED type with bracket arrangement all as per required and directed by Engg in Chrge MAke - Wipro Cat No LR13-241-XXX-57-XX or equivalent in Philips/Oshram complete all as specified 92 M & L for Sub main wiring with approved colour coding as per IS with two runs of single core PVC insulated cable FRLS with Multi Strand copper conductor of size 6 Sq. mm and drawing into PVC conduit including one run of PVC insulated 6 sqmm stranded copper conductor earth wire complete all as directed. 93 M & L for Sub main wiring with approved colour coding as per IS with two runs of single core PVC insulated cable FRLS with Multi Strand copper conductor of size 4 Sq. mm and drawing into PVC conduit including one run of PVC insulated 4 sqmm stranded copper conductor earth wire complete all as directed.(for AC Point) 94 Supply and fixing ceiling fans complete with blades, down rods,and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with bruchiess direct current motor (BLDC) along with hanging arraangement,connecting with accessories like suitable length copper conductor cable, fastener bolts, fan hook, fan box all complete. Make : Orient Usha/ Bajaj/ Havells/ Crompton complete all as specified 95 S & F for MCB DBs 8 Way SPN, 240 volts for mounting MCBs/RCBOs ELCBs etc. as per IS specification of factory made fabricated out of CRCA sheet 1.2 mm thick powder coated fitted with DIN Channel neutral link and 200 Amps rated bus bar.The DBs shall double door type . Inner door fixed on spring loaded hinges with locking arrangement & outer door openable hinged with locking arrangement having IP-43 protection complete all as specified 96 S & F for MCB SPN 40 Amps 240 Volts C Curve 10 KA complete all as specified 97 S & F for MCB SP 6-32 Amps 240 Volts C Curve 10 KA complete all as specified 98 Total contract sum shall be calculated after deduction of schedule of credit amount of Rs. 1,700.00