Tender For Periodical Services To Otm/Md Accn In Zone-I Area Underage B/R-I Of Ge Jaipur; 1 M&L preparation of old decorated surfaces including brooming down and cleaning the surfaces and applying one coat of white wash on wall complete all as specified & as directed. 2 ,---ditto--- all as per item No 1 above but two coats of white wash on wall surface complete all as specified & as directed. 3 ,---ditto--- all as per item No 1 above but one coat of white wash on ceiling surface complete all as specified & as directed. 4 ,---ditto--- all as per item No 1 above but two coats of white wash on ceiling surface complete all as specified & as directed. 5 M & L preparing new plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed. 6 M&L for complete removal of existing treatment by scrapping upto plastered surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7/9 to make the surface free from dust, loose paint etc complete all as specified & as directed. 7 M&L for preparation of surface and applying water proof putty @ 0.5 Kg(undiluted) per sqm of average thickness 1 mm over the plastered/old painted surface which scrapping is done to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 240 Grit or above to make the surface free from dust etc. by skilled labour as per following steps:- Step 1) Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute. Step 2) Apply the first coat of prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSI.Step3) Allow 6-8 hrs time to dry the putty surface and rubbing complete all as specified and directed. 8 M&L for preparation of surface and applying one coat of acrylic water based interior grade primer @0.9 ltr(undiluted)/10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed. 9 M&L for preparation of surface and applying two coats of distemper (Oil emulsion) on walls of approved tint applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI and allow 6-8 hrs to dry the surface in both the coats of paint complete all as specified and as directed. 10 M&L for preparation of surface and applying one coat of distemper (Oil emulsion) on ceiling of approved tint with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI over primed surface complete all as specified & as directed. 11 M&L for preparation of surface and applying one coat of acrylic water based exterior grade primer @ 0.9 ltr(undiluted) /10 sq mtrs diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed. 12 M&L for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI, Allow 6-8 hrs to dry the surface for painting of subsequent coats over exterior primer complete all as specified and directed. 13 ,---ditto--- all as per item No 12 above but one coat of 100% Premium acrylic emulsion paint on wall complete all as specified and directed. 14 M&L for preparation of old decorated plastered / unplastered surfaces of walls, soffits of chajjas, cornices etc and applying two coats of cement base paint all as specified and directed. 15 M&L for preparation of old decorated plastered / unplastered surfaces of walls, soffits of chajjas, cornices etc and applying one coat of cement base paint all as specified and directed. 16 M&L forpreparation of old painted surfaces of wood or wood based materials of any description ot otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. 17 M&L preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified & as directed. 18 Demolition of brick work or stone/ boulder masonary, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. 19 M&L for brick work with sub-class B bricks (old size), straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed 20 M&L brick work with sub- class ‘B’ bricks (old size), straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified & as directed. 21 Taking down cement plaster or cement lime plaster, any description on brick, stone walls or concrete surface of ceiling etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed 22 M&L rendering 15mm thick in CM 1:6 on stone masonry surfaces or on surface other than fair faces of brick masonary finished even and smooth without using extra cement complete all as specified and directed. 23 M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick masonry surfaces or concrete surface finished even and smooth without using extra cement complete all as specified and directed. 24 M & L for rendering 10 mm thick in CM 1:3 on concrete surfaces of ceiling, reinforced with chicken wire mesh finished even and smooth without using extra cement complete all as specified & as directed. 25 Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubish off the premises complete all as specified and directed. 26 Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15cm thickness (below or above ground level) complete all as specified and as directed 27 M & L for 75 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in floors complete all as specified and directed. 28 M&L for coloured jointfree non skid ceramic tiles, 300 x 300 x 7 to 8 mm thick (Square/rectangular) in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed 29 M&L for coloured glazed ceramic tiles 450/600mm X 300mm X 7 to 8mm thick on vertical surfaces of wall such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10mm thick backing coat in CM 1:4 complete all as specified and directed 30 S&F in repair 15mm bore steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or laid in floor incl taking down old tubing complete all as specified and directed 31 S&F in repair 20mm bore steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or laid in floor incl taking down old tubing complete all as specified and directed 32 S&F in repairs 15 mm bore bib tap, fancy type, chromium plated cast copper alloy with cruth or butter fly handle, long body, screwed down, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. 33 S&F in repairs PVC valveless,syphonic action type flushing cistern low level 10 ltr capacity white, with intel, ball valve, float and handle including brakects flushing, brakects flushing pipe complete all as specified & as directed. 34 S&F in repair PVC Connections 15mm size, 600mm long with PTMT nuts complete all as specified and as directed. 35 S&F in repairs Vitreous China wash basin, white , flat back, size 550mmx 400mm excluding taps, chain & plug and porcelene stopper but including brackets /fastners, PTMT coupling and PVC waste pipe utting for and pinning in ends of brackets complete all as specified & as directed. 36 S&F in repair Pillar tap, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe 15 mm complete all as specified & as directed. 37 S&F in repair stainless steel grating doom 100 mm dia with or without waste hole complete all as specified & as directed. 38 S&F in repairs vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device and connection to drain (or out going pipe) and to flushing pipe etc. completeall as specified and directed. 39 S&F in repair vitreous china Squatting pan Orissa pattern water closet white size 580mm x 440 mm with integral foot rest (excludinfg flushing cistern and flush pipe) complete including connection to trap and flushing pipe antisyphone pipe etc complete all as specified & as directed. 40 S&F in repair vitreous China urinals, bowl type(back or corner wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete all as specified & as directed. 41 S&F in repair 500 Ltrs capacity rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) hoisted and fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc including dismantling of old unservicable water tank complete all as specified in SSR Part I, 42 S&F in repair 1000 Ltrs capacity rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) hoisted and fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etcincluding dismantling of old unservicable water tank complete all as specified in SSR Part I, 43 Note:- (a) 50% qty of material reqd for periodical services in this contract shall be procured in advance in seal packed container or bags after approval of the sample.(b) Work pertains to periodical services shall be executed through authorized applicator of manufacturers approved by GE.(c) The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule A/BOQ