}

Tender For Provn Of Storage Sheds Under Ge (N) Udhampurunder Ge 862 Ews, udhampur-Jammu And Kashmir

Military Engineer Services has published Tender For Provn Of Storage Sheds Under Ge (N) Udhampurunder Ge 862 Ews. Submission Date for this Tender is 21-08-2025. Shed Construction Tenders in udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

50222388
Tender For Provn Of Storage Sheds Under Ge (N) Udhampurunder Ge 862 Ews
Tender
Indian
Jammu And Kashmir
Udhampur
21-08-2025

Tender Documents

Tender Details

Tender For Provn Of Storage Sheds Under Ge (N) Udhampurunder Ge 862 Ews; 1 Sch A Part-I(Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as Rs. 0.00 under col.5 signifies this fact only. 2 Construction of block of storage shed (Internal size 46m x 21.2m) including Verandah, Ramp, Steps (but excluding hard standing) complete all as shown on drawings andas specified. 3 Construction of block of storage shed (Internal size 32.5m x 21.2m) including Verandah, Ramp, Steps (but excluding hard standing) complete all as shown on drawings andas specified. 4 TotalAmount of Sch A Part - II (Internal Electric Supply Work) 5 TotalAmount of Sch A Part - III (Area Drainage Work) 6 TotalAmount of Sch A Part -IV (Road and Hard StandingWork) 7 TotalAmount of Sch A Part - V (External Water Supply Work) 8 TotalAmount of Sch A Part - VI (External Electric Supply Work) 9 Sch A Part - VII (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as Rs. 0.00 under col.5 signifies this fact only. 10 Supply, install, testing and commissioning offactory made outdoor type CPRI approved dust and vermin proof LT panel board front opening (double shutter) with locking arrangement of suitable size made out of 3.15 mm thick CRCA sheet (IS-8623) with 50mm x 50mm x 6mm angle iron frame duly painted with two coats of powder coated paint over a coat of red oxide primer on outer surfaces and epoxy paint on inner surfaces, protection class IP-56, grouted on floor. The LT panel board shall be suitable for operating on AC 415 volts, 3 phase, 50Hz, 4 wire system with suitable of PVC copper conductor for internal wiring,thimbles gland, cable lugs, nuts, bolts, washers, etc. including PCC foundation (PCC 1:2:4 type B-1)of suitable size as per panel board 0.5 Mtr above ground level grouting and bottom portion of enclosure shall be minimum 30 cm above ground level of legs of angle ironand supply & comprising of the following including internal pre-wiring complete:- 11 INCOMING(i) 200 Amps capacity copper bus bar strip - 4 No. of suitable length. (ii) MCCB, FP, 100 Amps, capacity 16KA, 4 pole, 3 phase, 415 volts with thermal magnetic release (Ics = 100% Icu) - 01 No.(iii) Voltmeter 0-500 V with selector switch(Digital type) - 01 set. (iv) Ammeter 0-500 Amps with 3 Nos. CT coils and selector switch (Digital type) -01 Set(v) Indicator lamp neon/ LED type RBY -01 Set of three.(vi) copper bus bar capacity 200 Amps for Phase-R-Y-B- N - 4 No.OUTGOING:(i) MCCB FP 80 Amps, capacity 16 KA, 4 pole, 3 phase, 415 volts - 02 No. (spare 1 Nos) 12 Supply, install, testing and commissioning offactory made outdoor type CPRI approved dust and vermin proof LT panel board front opening (double shutter) with locking arrangement of suitable size made out of 3.15 mm thick CRCA sheet (IS-8623) with 50mm x 50mm x 6mm angle iron frame duly painted with two coats of powder coated paint over a coat of red oxide primer on outer surfaces and epoxy paint on inner surfaces, protection class IP-56, grouted on floor. The LT panel board shall be suitable for operating on AC 415 volts, 3 phase, 50Hz, 4 wire system with suitable of PVC copper conductor for internal wiring,thimbles gland, cable lugs, nuts, bolts, washers, etc. including PCC foundation (PCC 1:2:4 type B-1)of suitable size as per panel board 0.5 Mtr above ground level grouting and bottom portion of enclosure shall be minimum 30 cm above ground level of legs of angle ironand supply & comprising of the following including internal pre-wiring complete:- 13 INCOMING(i) 200 Amps capacity copper bus bar strip - 4 No. of suitable length. (ii) MCCB, FP, 63 Amps, capacity 16 KA, 4 pole, 3 phase, 415 volts with thermal magnetic release (Ics = 100% Icu) - 01 No.(iii) Voltmeter 0-500 V with selector switch(Digital type) - 01 set. (iv) Ammeter 0-500 Amps with 3 Nos. CT coils and selector switch (Digital type) -01 Set(v) Indicator lamp neon/ LED type RBY -01 Set of three.(vi) copper bus bar capacity 200 Amps for Phase-R-Y-B- N - 4 No.OUTGOING:(i)MCB SPN 32 amps capacity 10 KA single phase - 06 No (spare- 1 No) 14 Construction of valve chamber of size 900mmx 900mm x 900mm(Internal dimensions)using PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate for foundation 10cm thick and 100mm offsets on all sides,230mm thick, brick wall masonry walls, built in cement mortar (1:6), 15mm thick, rendering all around the masonry work in cement mortar (1:6),for internal andupto 15cm below GL for external surfaces of walls,50mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate including necessary form work including 3.15mm thick, MS top sheet coverdouble door with locking arrangement welded toMS frame made out of 50x60x6 mm angle iron frame fixed with hold fasts including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer as finishingcoat including necessary excavationin any type of soil, returning filling in and removal ofsurplus soil to a distance not exceeding 50 mtrs, complete all as specified and directed. 15 Road crossingby adopting trenchless tunnelling work through specialised pipe jacking method by erecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunnelling, excavation in any types of soil hard rock, including inserting DWC HDPE casing pipein any length and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorities all as specified and as directed. Note: Quoted rate is deemed to be inclusive of all necessary tools/plant/machinery and obtaining necessary permissions from concern authorities to carryout the work. 16 Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directed in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level) connected to and including galvanised strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron including PCC 1:2:4 in pit, angle iron 25x25x3mm frame work with precast RCC 1:2:4 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12 mm dia MS fabricated handle, mediumgrade GI watering pipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 40mm bore upto 7.5m length for drawing in earth lead wire, salt, charcoal, etc. Including excavation and earth work in any type of soil, removal of surplus soil to a distance not exc. 50m complete all as shown in electrical plate No 3 of MES schedule 2009 (Pt-I) and connected to main control board all as specified or indicated including testing on completion, complete all as specified and as directed. 17 High Density Polyethylene (HDPE) size 90 MM Double Walled Corrugated (DWC) Pipes as Telecom & Power Cable Ducting Outer wall Being Corrugated impacts, excellent ring Stiffness (Compression Strength) Inner Wall: Smooth allowing easy insertion of Cable, Colour: Orange, IS 16205: PART 24 :2017, Compression strength Compression strength at 5% applied of Deflection load ≥ 750 N, External influence: (IP -67) ingress of dust-the joint is dustproof. ingress of water- the joint is waterproof, complete all as specified and as directed. 18 All as per Srl item No.13.00 above but size 75mm bore. 19 All as per Srl item No.13.00 above butsize 40mm bore. 20 Construction of PCC platform for transformer of size 3m x 3m and 1m high from ground level with brick construction in walls and steps, PCC 1:5:10 type E-2 in foundation, brick workin CM 1:4, 10mm thick rendering in CM 1:4 to walls, 50mm thick PCC 1:2:4 type B-1 (using 20mm graded crushedstone aggregate). In flooring40mm thick PCC on steps, painting to fencing with two coats of synthetic enamel paint over a coat of red oxide primer complete duly surrounded with XPM fencing of length not less than 15 meter and width not less than 10 meter complete with 40mmx5mm angle iron & 12mm dia steel bars, fixed on PCC gate pillers complete including sliding bolt, locking arrangements hinges and all accessories,shown on drawing No CE/TD/1129/96 sheet No. 1/2 & 2/2complete all as specified. 21 Cutting the existing MS/DI/CI branch line pipe line of any size from header carefully by means of gas cutter, removing the rusted MS pipe lines, making provision for joining new MS / CI / DIpipes of same size by welding MS flanges of suitable size and making leake proof joint including all jointing materials like bolts, nuts and gaskets required at site complete all as specifiedand as directed.Note:MS / DI / CI pipes will be measured and paid under relevant items complete all as specified and directed. 22 Supply, installation, testing & commissioning of transformer of capacity 63KVA step down outdoor type leve - II copper wounded 11/0.433KV (at no load) AC 3 phase, vector group Dyn 11, 50HZ on secondary side double wound oil immersed naturally all air cooled with external cooling tubes /radiator , delta connected as on primary and star connected with netural brought out on secondary side and having tapping at -2.5% to +7.5% in steps of 2.5% to be changed by external hand operated self position off load tap change switch. Also provision shall be made for locking the taping switch handle in position. The maximum temperature rise should not exceed 35 degree centigrade on top of oil when measured thermometer and 40 degree centigrade in HV/ LV winding when measured by the resistance method after continuous full load run in ambient temperature the transformer shall confirming to IS 1180-2014 and comprising of following accessories complete all as specified and as directed. 23 a) 03 No porcelains HV bushing with arching horns on HV side suitable for 11 KV complete with bushing rods nuts.b) 01 No. cable end box on LV secondary side consisting of 05 No. porcelain bushing (One No. neutral earth, One No, Neutral and Three No. for phaseconnected bushing) with bushing rods and nuts washers and cable glands suitable for reception of out 3.5 core, 400 Sqmm cable 3 runs, LT 1100 V grade XLPE insulated heavy duty including gland joint complete. c) Oil conservator with filter type drain valve and oil level gauge.d) Dehydrating breather with first filling of dehydrating agent e) Explosive vent.f) THERMOMETER pocket including temperature gaugeg) Two earthing terminal on tank body to facilitate fixing of 32x6mm GI strips. 24 h) OneNo thermometer dail type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature gauge : Max reading painted terminal.i) Rating plate with terminal plate.j) Oil level gauge.k) Oil drain filter valve.l) Oil filling hole on top cover with plug.m) Air release valve/plug.n) 4 Nos plain solid cast steel detachable rollers. o) First fill of transformer oil conforming to relevant ISI and tested upto 60 KV dielectric strength.p) Two No lifting hook at side of transformer 25 Drop out fuse unit, expulsion type for out door air break gang operated switch, single pole mounted on and including insulators and jumpers for 11 KV working pressure fixed to and includingMS channel with nuts, bolts and washer etc., synthetic bounded fuse tube complete with line capacity suitable for current carrying capacity 100 Amps complete all as directed. 26 Point wiring for One light/fan point/call bell point controlled by oneway switch, 5 Amp with 1.5 Sqmmsingle core multi standed copper conductor FRLSH insulated and unsheathed heavy duty cable in colour code including earth wire with cable of size 1.5 sqmm copper conductor FRLSH insulated, drawn into and including concealedin PVC conduit of not less than 25mm dia and half portion surface wiring through ceiling/truss,1.2mm wall thickness (ISI marked) terminated into annealed steel terminal boxes including modular plate and cover for mounting modular switch/ socket switches, sockets, fan regulators etc complete all as specified and directed. 27 All as per Srl item No. 20.00 above but for one 3/5 pin socket outlet , 5 Amp independend board. 28 All as per Srl item No. 20.00 above but for one socket outlet, 3 pin, 5 Amp, SP on same board. 29 Point wiring for power point control by one switch with 2.5 Sqmm nominal area PVC insulated single core multi standard copper conductor FRLSH insulated and undheathed heavy duty cable in colour code including earth wire with cable of size 2.5 sqmm copper conductor flexible FRLSH insulated drawn into and including concealed in PVC conduit of not less than 20mm dia and 1.5mm wall thickness (ISI marked) terminated into annealed steel terminal boxes including modular frame and cover plate for fixing of switches, sockets etc; complete all as specified and as directed. 30 Slim linear, LED lighting fixture 20 Watt, LED batten, P.F greater than 0.9, input voltage range from 230 Volts to 240 Volts, with full base of polycarbonate extruded section acting as a heat sink with closed back isolated driver complete making all connection using 1.5 sqmm copper conductor multistranded PVC insulated 2 core, flexible cable with from ceiling rose to fitting complete all as specified and as directed. 31 High bay light fitting of 70 Watt Cavelo Trade is an integrated well glass luminaire with die case canopy & gear housing. A versatile well glass series with both eye bolt & cradle for multiple mounting options. This IP66 well glass series delivers 120 lumens per watt complete all as specified and directed. Make:Crompton Cat Part No. TIP-314-70-57-SL-CP-NSG or equivelent make as specified in list of make. 32 LED street light fitting 35 Watt, 230 V, AC, outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, including provision of GI bracket made of 40mm dia, GI pipe, 1.5mlong, bend to shape, complete all as specified. 33 Sub main wiring with two run of FRLSH PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.00 Sqmm, 1100 Volts grade and one run of 6.00 Sqmm FRLSH PVC insulated unsheathed as earth (In green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and drawing in steel conduit 25mm dia, connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed.Note :-Two run of single core cable with one run of continuous earth wire of copper conductor wire Flexible (Multistrand) of FRLSH PVC insulated and 25mm steel conduit shall be measured and paid as one unit length. 34 Sub main wiring with two run of single core FRLSHPVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4.00 Sqmm drawing through and includingconcealed rigid non metallic PVC conduit medium grade (ISI marked) 20mm dia or above as required including one single core FRLSH PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4.00 sqmmas earth continuity conductorconnected to commen earth and earth dolly complete all as specified and directed.Note : - Two run ofsingle core copper conductor cable and one run of single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only. 35 Earthing complete with galvanized steel earth plate electrode600x600x6mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.Note:- On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction. 36 MCB SPN,40 to 63 Amps, 240V, 50Hz, 10KA ‘C’ series complete with connection testing and commissioning all as specified anddirected. 37 MCB SP,6 to 32 Amps 240V, 50Hz, 10KA ‘B’ seriescomplete with connection testing and commissioning all as specified anddirected.

Key Value

Document Fees
INR 3000 /-
EMD
INR 1020500.0 /-
Tender Value
INR 13.91 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail