Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 25-07-2025 | AMENDMENT CORRIGENDUM | Other | 07-08-2025 |
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal ofdebris and rubbish complete all as specified and directed. |
| 2 | Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal ofdebris and rubbish complete all as directed by the Engr-in-Charge |
| 3 | M & L for 25 mm thick, plain cement concrete 1:2:4,type B-0 (using 12.5 mm graded stone aggregate)as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed. |
| 4 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6complete all as specified and directed. |
| 5 | M & L for 75 mm thick,plain cement concrete1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed. |
| 6 | M & L for 75 mm thick, Plain cement concrete 1:2:4,type B-2 (using 40 mm graded stone aggregate)as in base footpath, etc and finished the surface even and rough to receive the screed bed complete all as specified and directed. |
| 7 | M & L for Chequered cement concrete coloured tiles of size 20cm x 20cm x 25mm thick, as in floors etc,including 20 mm thick screed bed in cement mortar 1:6 and set & jointedin neat cement slurry and pointed with grey cement and pigments to match with the shade of tiles complete all as specified and directed. |
| 8 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 9 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges and keeping serviceable sheets in safe custody for reuse in the work complete as directed. |
| 10 | M & L for Rolled mild steel fo grade Fe 410-W (Gde-E- 250) quality-A as in roof trusses (framed),trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pices, cleat etc complete all as specified and directed. |
| 11 | S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer\"s instruction complete all as specified and directed. |
| 12 | S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer\"s instruction complete all as specified and directed. |
| 13 | M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed. |
| 14 | Demolition of brick work or stone / boulder masonry/ precast concrete block masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal ofdebris and rubbish complete all as directed by the Engr-in-Charge. |
| 15 | M & L for Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate),block masonry with solid blocks of size 300x200x200mm or 300x200x100mm, having compressive strength of not less than 100 Kg/Sq Cm (As per IS-2185) exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 16 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish complete all as specified and directed |
| 17 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 18 | M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4,mixed with integral water proofing compoundwith weight of cement in top layer as per manufacturer\"s instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 19 | Supply only integral water proofing compound (ISI marked) complete all as specified and directed. |
| 20 | M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed. |
| 21 | M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 22 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets/snap grid/frame work etc complete all as specified and directed. |
| 23 | S & F powder coated aluminium Anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestor E-board, HSPC, designer, pre-primed, self exposed, textured, water resistant, termite resistant, fire resistant for insulation board fixed to framecomplete all as specified and directed by the Engr-in-Charge. |
| 24 | Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed. |
| 25 | Taking down shutters of any description exc 2 Sqm each complete all as specified and directed. |
| 26 | S & F 35 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 27 | S & F Powder coated aluminium sections (minimum 50 micron) of approved colour as in door, window, ventilator frames, partitions with one or more rebates and door, windows shutters sliding/openable type/ventilator shutter including provision of necessary jointing cleats, glazing clips, neoprene rubber packing, powder coated aluminium snap beading, screws inclding provision of suitable size of powder coated aluminium fittings such as locking arangements, handles, stainless steel fiction hinges and tower bolts etc including fixing only glass panels/particle board panels/wire gauge/aluminium grill etc complete all as specified and directed. (Note : (i)The size of aluminium sections shall be all as specified in relevant IS Code and MES Schedule Part-I (ii) Glass panels/ Partricle Board panels/ Wire gauge etc shall be measured paid seperately as supply only rates under respective items here-in-below). |
| 28 | S & F 100 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed. |
| 29 | S & F 150 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 30 | S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 31 | S & F 300 mm Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sectionsor cast aluminium alloy, length of bolt complete all as specified and directed. |
| 32 | Supply only 5.5 mm thick, sheet glass,ordinary quality and glazing withbeading for door/window etc in square exceeding 0.5 Sqmin each pane complete all as specified and directed.(Note: The cost of fixing and glazing beads included with the unti quoted rate of respective shutter) |
| 33 | Supply onlyStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed.(Note: The cost of fixing included with the unti quoted rate of respective shutter) |
| 34 | S & F in repairStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed. |
| 35 | M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 36 | M & L for Preparation of oldpainted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed. |
| 37 | M & L for Preparation of old treated asbestos cement building board surfaces of walls etc of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 38 | S & F in repairs 24 mm outer dia, stainless steel, curtain rail/rod, heavy duty, minimum 1mm wall thick including brackets, side holder and rings etc fixed to /wall etc complete all as specified and directed.(Note: (i) Stainless steel decorative finials and stainless steel brackets shall be provided for each leangth of curtain rail/rod and cost of the same shall deemed to be included in the unit quoated rate. (ii) Length of of curtain rail/rod shall only be measured for payments) |
| 39 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depthfor foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 40 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. |
| 41 | Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting pointcomplete all as specified and directed. |
| 42 | M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed. |
| 43 | M & L for use & waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter complete all asspecified and directed. |
| 44 | M & L for use & waste Formwork to sides of pillars, posts, struts, piers, columns and stanchionsfor flat rough finished surfaces of concrete complete all as specified anddirected. |
| 45 | M & Lfor Reinforced Cement Concrete M-25 (Design Mix) (using 20 mm graded stone aggregate) as in foundations including rafts, footings, beams and mass concrete, etc complete all as specified and directed. (Note: Reinforcement will be measured and paid seperately) |
| 46 | M & L for Reinforced Cement ConcreteM-25 (Design Mix) (using 20 mm graded stone aggregate) as in columns, pillars, posts and struts complete all as specified and directed. (Note :Reinforcement will be measured & paid seperately) |
| 47 | S & F high strength TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 48 | S & F high strength Mild steel TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed. |
| 49 | S & F Mild steel screw bolts of 16 to 20 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm and n.exc 30cm long complete all as specified and directed. |
| 50 | S & F Rolled mild steel in Plates (plain or chequered) channels fo grade Fe 410-W (Gde-E- 250) quality-A, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as speicfied and directed. |
| 51 | M & L for Rolled mild steel fo grade Fe 410-W (Gde-E- 250) quality-A as in roof trusses (framed),trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pices, cleat etc complete all as specified and directed. |
| 52 | M & L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed. |
| 53 | Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed. |
| 54 | M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 55 | M & L for 100 mm thick, plain cement concrete 1:4:8,type D-2 (using 40 mm graded stone aggregate)as in sub-base of flooring, etc complete all as specified and directed. |
| 56 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6complete all as specified and directed. |
| 57 | M & L for Plain cement concrete 1:3:6, type C-1, (using 20 mm graded stone aggregate) as inroof kerb or mud stop, benching etc rounded or chamfered on edges incuding necessary form works etc complete all as specified and directed. |
| 58 | Excavation over areas, n.exc 1.5 m in depth and getting out in soft/loose soil complete as specified and directed. |
| 59 | Excavating over area exc. 1.5 metre & not exc. 3 metre depth (beyond the first 1.5 metre) and getting out in soft/loose soil complete all as specified and directed. |
| 60 | Excavation over areas, exc 3.0 m and n.exc 4.50m in depth and getting out in soft/loose soil complete as specified and directed. |
| 61 | M & L for use & waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etcetc complete all as specified anddirected. |
| 62 | M & L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed. |
| 63 | M & L Reinforced Cement ConcreteM-25 (Design Mix) (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed.(Note :Reinforcement will be measured & paid seperately) |
| 64 | M & L for Reinforced Cement Concrete M-25 Design Mix (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, and in shelves and the like etc complete all as specified anddirected. (Note: Reinforcement will be measured and paid seperately) |
| 65 | M & L for Pre-cast cement concrete type 1:3:6 (using 16mm graded stone aggregate),block masonry with hollow blocks,as in honeycomb walling, exc. 10 cm in width and setting in mortar 1:4 complete all as specified and directed. |
| 66 | S & F 75 mm bore, PVC (SWR),Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc completeall as specified and directed. |
| 67 | S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed. |
| 68 | S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 69 | S & F 110mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 70 | S & F 75 mm bore, PVC (SWR) vent cowl complete all as specified and directed. |
| 71 | M & L for Precast reinforced cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in landing, cover slabs, shelves and similar articles with plain faces and set in CM 1:6 complete all as specified and directed.(Note: Reinforcement shall be measured and paid seperately) |
| 72 | M & L for loose filling with broken bricks aggregates of gauge 80 to 150 mm in soakage well complete all as specified and directed. |
| 73 | S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc completeall as specified and directed. |
| 74 | M & L for Providing cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) for filling hollow portion, pressed steel frames, etc complete all as specified and directed. |
| 75 | M & L for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding holdfast, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating asdirected complete all as specified and directed. |
| 76 | M & L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and directed. |
| 77 | Extra for forming fair finished to concrete surface of drain 30cm inner girth in cement including forms, mould, mitred/stopped etc complete all as specified and as directed. |
| 78 | Add or deduct for each 25mm girth or part thereof over or under 30cm including form mould, mitred/stopped etc. complete all as specified and as directed. |
| 79 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 80 | Taking down unserviceable main switches, DBs, bus bars chambers, VTPN etc any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified anddirected. |
| 81 | M & L for Point wiring for one light/exhaust fan/fan point/call bellcontrolled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductorcable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) |
| 82 | All as per item No. 81 above but for One 3/5 pin socket outlet 6 amps pointon same boardcomplete ditto |
| 83 | All as per item No. 81 above but forOne 3/5 pin socket outlet 6 amps on independent board complete ditto |
| 84 | All as per item No. 81 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistrandedFRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cableFRLS (ISI marked) as earth lead complete ditto |
| 85 | S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed. |
| 86 | S & F Socket outlet 2 in 1, 3 pin, 6 Amps, flush type complete all as specified and as directed. |
| 87 | S & F Switch socket combination 2 in 1, 6 Amp, flush type complete all as specified and as directed. |
| 88 | S & F Switch socket combination 2 in1, 3 pin, 6 and 16Amp, flush type, universal complete all as specified and as directed. |
| 89 | S & F Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed. |
| 90 | S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed. |
| 91 | S & F LED tube light fittings, retro bar professional WH 5700K to 6000K, 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specifiedand directed. (Make: Havell\"s Cat No. LUMILINENEOBS20WLED840SPCSSIND or equivelant of make as per list of manufacturer) |
| 92 | S & F 2ftx2ft recessed mounting, LED panel light fittings, 36 Watt with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specifiedand directed. (Make: Havell\"s Cat No. VENUSNEOHE2X2R36WLED840PIRSENSOR or equivelant of make as per list of manufacturer) |
| 93 | S & F LED Bulk Head, 10 Watt, IP 65 rated, compact design, PC Co extruded with high energy saving with all accessories and connecting up including lamp complete all as specifiedand directed. (Make: Crompton Cat No. TIS-304-10-57-SL-DP-NWH or equivelant of make as per list of manufacturer) |
| 94 | S & F Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed. |
| 95 | S & F LED Bulb, 15 Watts, B-22 Lumen ≥ 1200, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specifiedand directed. |
| 96 | Taking down and dismantling the ceiling fan 1200 / 1400 mm sweep of any capacity from existing position and removing its allied spare parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable minor parts and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, spilt pins, screws, nuts and spring washers etc and applying one coat of spray painting complete including provn flexible copper conductor cable of 24 / 0.20mm of required length with necessary connector (for blade / body) as required complete all as specified and directed. (Note : (i) Cost of minor spare parts shall deemed to be included in quoted rate. (ii) The cleaning, servicing, oiling and lubricating of fans has to be carried at site itself and to be completed withing one hour unless re-winding is required. ). |
| 97 | S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Havell\"s cat part No. DHDPSHODRW08 or equivalent make as per List of Manufacturer\"s) |
| 98 | S & F MCB SPN 6-32A Amps, 240 Volts,10KA, C Curve complete all as specified and as directed Havell\"s cat part No. DHMGCSNF006-032 or equivalent make as per List of Manufacturer\"s) |
| 99 | S & F MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve,complete all as specified and as directed (Make: Havell\"s cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer\"s) |
| 100 | M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia TMT bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. |
| 101 | S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete all as specified and directed. |
| 102 | S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 150 mm and 50 mm deep complete all as specified and directed. |
| 103 | S & F 1100 volts grade, heavy duty cablePVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathedin service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, 16 Sqmm 2 core solid conductor including taking down existing one complete all as specified and directed. |
| 104 | S & F in repair House service bracket (hook type) complete with 3.0m long GI pipe 40mm dia, Medium Grade, two nos. 90 degree bends, M.S. hook and stay or guy complete all as specified and directed. |
| 105 | S & F Surface and wall mounted LED batten, 10W, 220V, AC, 2 feet, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10%including lamp, fixing accessories and connecting up complete all as specifiedand directed. (Make : Havell\"s Cat No. ENDURALINEARNEOBS10WLED865SPCWH and equivelant model of make as specified in list of manufacturer). |
| 106 | S & F wall mounted fan made of sturdy engineering plastic complete with speed regulator and wide osciliation control, 300 mm sweep, AC, single phase 230 Volts, 50 Hz, minimum RPM 1350, copper windind complete with all accessories and electric connection complete all as specified and directed (Make : Havells Cat No. FHWSWSTLGR12 or equivalent model of Bajaj/Usha/ Khaitan/Orient as approved) |
| 107 | S & F sheet metal enclosure, single door MCB DBs, phosphatised, powder coated, Single pole & neutral (SPN),02 way, 240 Volts suitable for housing MCBs with din rail, neutral and earth bar in proper psoition complete all as specified and directed. |
| 108 | M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cableas earth continuity conductorcomplete all as specified and as directed.(Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduitshall be measured as one length) |
| 109 | S & F Single phase sheet metal enclosurewith socket plug top and MCBs having Triple pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 32 Amp 415V, C-curve complete all as specified and as directed. |
| 110 | Supply, install, testing & Commissioning, 5 STAR rated Hi wall split type air conditioner with indoor and outdoor units complete with cordless remote control unit and with in-built advanced air filters for better indoor air quality with latest inverter technology, having eco friendly refrigerant gas, copper condenser coil, EER 4.5 or above of capacity 2.0 TR, summer cool, Inverter compressor, automatic 2D swing copper condenser, BLDC motor, necessary copper pipe connections including cutting, bending, brazing, insulation on pipes etc, PVC drain pipe, electric connection in between indoor and outdoor unit with suitable size of PVC insulated, multi-stranded copper cable complete with allfixing accessories such as bracket etc complete all as specified and directed. (Note: The unit rate quoted above shall deem to be inclusive of the following accessories/works:-(i) Powder coated MS fixing brackets of suitable size for outdoor and indoor units at any height (ii) Copper tube of suitable size upto 2m each(iii) Drain pipe made of High Density Polyethylene pipes [HDPE] of pressure rating 6Kg/Sqcm of 20mm dia upto 2m each(iv) 4 core, 4 Sqmm PVC insulated and PVC sheathed, heavy duty multi-stranded copper conductor cable, 1100 Volts, FRLS grade as required for connecting indoor and outdoor unit(v) Drilling hole on brick wall to facilitate routing of copper pipe, drain pipe and cable from indoor unit to outdoor unit(vi) Sealing hole from outside from outside with white cement and making good disterubed surfaces as per the existing one(vii) Pressure testing, cooling performance check and product demonstration(viii) M & L for fixing remote control in wall complete) |
| 111 | S & F voltage stabilizer for automatic operation,, single phase naturally air cooled indoor type and designed for inputvariationbetween 170 V to 250 V with output of 230V with accuracy of +/- 2.5% variation of capacity 5.0 KVA complete all as specified and directed. |
| 112 | S & F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete all as specified and directed. |
| 113 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately) |
| 114 | S & F Distribution Board, TPN 4 Way, 415V, Double door with IP 43protection, IK 09 complete all as specified and as directed. (Make: Havell\"s cat part No. DHDNTHCDRW04 or equivalent make as per List of Manufacturer\"s) |
| 115 | S & F MCB, TPN 40-63 Amps, 415 Volts, 10KA,C Curve complete all as specified and as directed(Make : Havell\"s Cat part No. DHMGCTNF040 to 63or equivelant of make as perList of manufacturer\"s) |
| 116 | M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion complete all as specified and as directed by the Engineer-in-Charge. |
| 117 | M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed.(Note: Thickness after punning down shall be measured for payment) |
| 118 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm complete all as specified and directed. |
| 119 | M & L for 50 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed. |
| 120 | M & L for boring of horizontally holes by manual method under road and dia of hole not exc 100mm without damaging the exsting road, getting out and disposal of excavated soil, etc to a distance not exc. 50 meter from the site of work complete all as directed by Engineer in charge. |
| 121 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 6 Sqmm 2 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing complete all as specified and directed. (Note: Excavation and earth work shall be measured paid seperately) |
| 122 | Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 flat, size 300mm x 180mm x 40mm complete all as specified and directed. |
| 123 | S & F 32 mm bore, steel tubes, galvanised, light grade with all fittings and fixed complete to walls and ceilings or laid in floors as in protection pipe complete all as specified and directed. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy