| 1 | B/R WorksDismantling of single layer Mangalore pattern or similar tiles in roofing complete all as specified and as directed. |
| 2 | Dismantling in fillets, rails, posts, rafters, purlins, etc, under 40 sqcm in section etc complete all as specified and as directed. |
| 3 | Dismantlingof timber scantling 40 sqcm and over in section in any position in chajjas as in unframed work, complete all as specified and as directed. |
| 4 | Demolition ofcement concrete including breaking and removing existing roof treatment on roof slabs and similar work etc complete all as specified and as directed by Engineer-in-Charge. |
| 5 | Material and labour for plain cement concrete 1:2:4, type B-0 using 12.5mm graded stone aggregate as in 25mm thicklevelling concrete on roof with proper slope, finished even and fair etc complete all as specified and as directed. |
| 6 | Material and labour for 10mm thick rendering in cement mortar 1:3mixed with water proofing compound @ 3% by weight of cement on roof surfaces, finished even and smooth without using extra cement etc complete all as specified and as directed.Note:Water proofing compound will be measured and paid separately |
| 7 | Material and labour for water proofing treatment to RCC roof slab by applying oil bound bitumen primer @ 0.27 litre/Sqm and lay APP modifiedpre fabricated five layer membrane of 4 mm thick and weight not less than 4.50 kg per Sqm reinforced with non woven polyester matt reinforcement weighing not less than 160gm/Sqm having softening point not less than 140 degree centigrade, longitudinal tensile strength not less than 650N/cm, tearing strength of 180, a static puncture resistance of 180, keeping minimum 10 cm side overlap and 15 cm end lap and apply by torch application over a coat of blown grade hot bitumen grade VG-10 conforming to IS 702 heated to a working temperature of 180 degree centigrade and applied a tack coat of industrial bitumen 85/25 @1.2 kg/sqm including cleaning surfaces. Membrane shall be filled laid including minimumand painting over APP Membrane sheet with solar reflective aluminium bituminous paint @ 0.10 Litre/Sqm etc complete all as specified and as directed. |
| 8 | Note:(i)10 Years guarantee certificate to be submitted by the contractor.(ii)Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialised agency/applicator which will further have to do rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise. |
| 9 | Material and labourfor 2nd class hard wood, clean sawn fillets/ battens for tiles sectional area exceeding 6Sqcm and not exceeding 13Sqcm complete all as specifiedand as directed. |
| 10 | Fixing only 2nd class hard wood, clean sawn fillets/ battens for tiles sectional area exceeding 6Sqcm and not exceeding 13Sqcm complete all as specifiedand as directed.Note: 2nd class hard wood, clean sawn fillets/ battens obtained from item No 2.00 shall be reused |
| 11 | Material and labourfor 2nd class hard wood, clean sawn, as in scantling, purlins, rafters etc fixed to timber frame work complete all as specifiedand as directed. |
| 12 | Fixing only 2nd class hard wood, clean sawn, as in scantling, purlins, rafters etc fixed to timber frame work complete all as specifiedand as directed.Note: 2nd class hard wood, clean sawn fillets/ battens obtained from item No 3.00 shall be reused |
| 13 | Material and labourfor preparing old woodensurfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of creosote oil complete all as specified and as directed. |
| 14 | Supply and fix Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick as per approved profile of any colour having tensile strength of 550 Mpa as in roof covering/ on Chajjas, fixed with self tapping screws or L type or J type or cranked hook bolts or as per manufacture instruction complete all as specified and as directed by Engineer-in-Charge |
| 15 | Supply and fix Pre- painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick as per approved profile of any colour having tensile strength of 550 Mpa as in roof covering/ on Chajjas, fixed with self tapping screws or L type or J type or cranked hook bolts or as per manufacture instruction complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Dismantling of wall and celling boards (fiber, pulp, insulation, etc)or insulation of boards/ slabs/ blankets, any thickness including cover fillets all as specified and as directed. |
| 17 | Supply and ix anodised aluminium snap grid of size 605mm x 605mm frame work for false ceiling all as specified |
| 18 | Material and labour for hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof by means of ceiling cleats made out of GI flat 40mm x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long etc complete all as specified and as directed. |
| 19 | Material and labour for non asbestos fibre cement buildings boards of 4mm thick inserted to aluminium frame work with screws fixed in ceiling flat or sloping complete all as specified and as directed. |
| 20 | Supply and fix mild steel flat iron as in wind tie for roof including securing bolts with all necessary drilling, screwed ends, nuts, washers etc conforming to Fe-290 Gde-E-165 etc complete all as specified and as directed. |
| 21 | Material and labour for plain cement concrete 1:3:6, type C-1 using20 mm graded stone aggregate as in roof kerbs, plinth courses, hold fast, coping, bed blocksetc., including formwork, weathering, slightly rounded or chamfered angles and throating etc complete all as specified and as directed. |
| 22 | Taking down cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and removing debris outside MD land complete all as specified and as directed. |
| 23 | Material and labour for 10mm thick rendering in cement mortar 1:6on brick/ concrete/ block masonry surfaces, finished even and smooth without using extra cement etc complete all as specified and as directed. |
| 24 | Material and labour for 5mm thick rendering in cement mortar 1:3on ceiling surfaces, finished even and smooth without using extra cement etc complete all as specified and as directed. |
| 25 | Material and labour for 15mm thick rendering in two coats (10mm + 5mm) 10mm thick in cement mortar 1:6 and 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturers instruction on brick/ block masonry surfaces, finished even and fair etc complete all as specified and as directed.Note:Water proofing compound will be measuredand paid separately. |
| 26 | Supply only integral water proofing compound |
| 27 | Material and labourfor clearing vegetation/ shrubs along with all the debris of leaf from roofs, sunshades, etc and making surface clean, making good with plaster in cement mortar 1:3 or PCC 1:2:4 (12.5 mm graded aggregate) as per the site requirement/ condition complete all as specified and directed. (Up to four storey) |
| 28 | Material and labour for preparation of new unplastered wall surfaces and applying two coats of distemper oil emulsion over a coat of alkali resistant priming paint etc complete all as specified and as directed. |
| 29 | Material and labour for preparation of new unplastered ceiling surfaces and applying two coats of distemper oil emulsion over a coat of alkali resistant priming paint etc complete all as specified and as directed. |
| 30 | Material and labour forcomplete removal of existing treatment on external walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 over 1mm thick external wall putty etc complete all as specified and as directed. |
| 31 | Supply and fix 110mm bore PVC (SWR) pipessingle socketed in any length with rubber ring joints fixed to walls including taking down eaves gutters and rain water pipes (any size or pattern) including all fittings and necessary scaffolding (upto four storey building) etc complete all as specified and as directed. |
| 32 | Supply and fix 160mm bore PVC (SWR) pipessingle socketed in any length with rubber ring joints fixed to walls including taking down cast iron pipes/ PVC pipes including fittings by burning out lead joints etc to facilitate dismantling old unserviceable fittings/ pipes laid in trenches/ floors including necessary earth workor fixed to walls and necessary scaffolding (upto four storey building) etc complete all as specified and as directed.Note: Cost of Necessary demolition of PCC/ brick work if required at site and making good to match with existing surfaces is deemed to be included in unit quoted rate |
| 33 | Supply and fix 110mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 34 | Supply and fix 160mm bore PVC (SWR) bends of any radius complete all as specified and as directed. |
| 35 | Material and labour for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; largehasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe290 Gde-E165 fixed in any position including drilling andnecessary screws, nails etc complete all as specified and as directed. |
| 36 | E/M WorksTaking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fittings such asswitches, ceiling roses, pendants, regulators, sockets etc., removing materials out side MD land in case of Credit and making good disturbed surfaces of walls, floors, etc., all as specified and as directed. |
| 37 | Material and labour for point wiring for complete with PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor conforming to IS-694, 1.5sqmm (nominal area), drawn through and including suitable dia non metallic rigid PVC conduit (ISI marked) andaccessories concealed in wall/ roof including provision of PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor 1.5sqmm as earth continuity conductor and connecting to common earth dolly complete all as specified and as directed by Engineer-in-Charge for the following.Note: (i)Cost of modular type sunken terminal boxes, cover plate with frame (modular plate) for mounting of switches, socket outlets, regulators etc will deemed to be included in the unit quoted rate.(ii)Cost of blank plate required if any will deemed to be included in the unit quoted rate.(iii)Cost of cutting chases in stone masonry/ brick masonry wall/ceilingsurfaces will deemed to be included in the unit quoted rate. |
| 38 | One light / fan / bell / buzzer point controlled by one, one way switch |
| 39 | One 3/5 pin 5 Amps socket point on the same board with other switches controlled by one switch. |
| 40 | One 3/5 pin 5 Amps socket outletpoint on independent board. |
| 41 | All as per item No 36.00 described here-in-before but for point wiring with 4 sqmm single core standard FRLS copper conductor and one run of 4 sqmm FRLS copper conductor, standard for earth wire for one 3/5 pin socket outlet point 15 amps on the independent board. |
| 42 | Supply and fix Modular type switch single pole 6A, one way, 1 module, 240V, AC, 50Hz, ISI marked complete all as specified and as directed. |
| 43 | Supply and fix Modular switch 1 way 16A, 1 module, 240V, AC, 50Hz, ISI marked complete all as specified and as directed. |
| 44 | Supply and fix Modular Bell push 6A, 1 module, 240V, AC, 50Hz, ISI marked complete all as specified and as directed. |
| 45 | Supply and fix Modular fan step regulator, 120W, 2 module, 240V, AC, 50Hz, ISI marked suitable for ceiling fan of any sweep complete all as specified and as directed. |
| 46 | Supply and fix Modular socket, 6A, 240volts, 2/3 pin combined 2 module, ISI marked flush type complete all as specified and as directed. |
| 47 | Supply and fix Modular socket, 6A/16A, 240volts, 2/3 pin combined 2 module, ISI marked flush type complete all as specified and as directed. |
| 48 | Supply and fix Ceiling rose,surface type polycarbonate insulated body, three terminal 65x32mm, ISI marked complete all as specified and as directed. |
| 49 | Supply and fix lamp holder, insulated body of PVC/ polycarbonate type with back plate suitable for angle/ batten fittings, ISI marked complete all as specified and as directed. |
| 50 | Supply and fix Call bell/ buzzer, electric (Ding-dongtype) suitable for working on 240 volts AC supply complete all as specified and as directed. |
| 51 | Supply and fix sheet metal enclosure single pole and neutralwith a two pin and earth plug and socket complete with one double pole MCB of 20 Amp, 240 volt complete all as specified and as directed. |
| 52 | Supply and fix distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof double door, TPN 4 way, 415volts grade with 200 Amps insulated busbar with nickel plated brass, isolated neutral bar and door earthing, earth bar IP-43 protection with poly urithene casketing, IK-08 mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCB SP etc including taking down existing unserviceable one etc complete all as specified and directed. |
| 53 | Supply and fix double door SPN MCB distribution board sheet steel powder coated DBs suitable for MCB fitted with bus bar neutral link earth bar and din rail single phase240 volts and neutral confirms to IS 13032- 1991 of 8 ways including taking down MCB DBs and MCB\"s complete all as specified and directed. |
| 54 | Supply and fix MCB single pole 5 to 32 Amps current carrying capacity, 240 volt rating, 10 KA, C curve with IP-20 protected terminals including contact indication window, IP-20 protection, energy limitation Class-3, airflow channels on both sides, bi-connect terminals etc, complete with connection, testing and commissioning and taking down old unserviceable one from the site complete all as specified and directed. |
| 55 | All as per item No 50 described here-in-before but for MCB single pole and neutral (SPN) 32 Amps |
| 56 | All as per item No 50 described here-in-before but for MCB single pole and neutral (SPN) 40 to 63 Amps |
| 57 | All as per item No 50 described here-in-before but for MCB Triple pole and neutral (TPN) 63 Amps |
| 58 | Taking down carefully existing serviceable ceiling fan/ wall mounted fan, ceiling cable end etc, removing the fan for keeping in safe custody, hanging the ceiling fan with down rod after rewiring including clamps, hooks hold fasteners etc and connection up, including making electric connection from ceiling rose or connector to fan complete all as specified and as directed |
| 59 | Taking down carefully existing serviceable exhaust fan, ceiling cable end etc, removing the fan for keeping in safe custody, fixing the exhaust fan connecting up after rewiring, including making electric connection from ceiling rose/ connector to fan complete all as specified and as directed. |
| 60 | Taking down carefully existing serviceable Geysers of capacity 25 Ltrs, ceiling cable end etc, removing the geyser for keeping in safe custody and refixing geyser with provision of new suitable MS bolts, grouted to wall and connecting up including provision of new 3 core sheathed multi-stranded flexible copper conductor cable, including making good to the disturbed surface and testing complete all as specified and as directed |
| 61 | Supply and fix in repairs LED luminaire 600mm x 600mm of 36 watt, 220 V, AC, recessed type/ ceiling type with minimum 120 lum/ watt efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and as directed.Make: LULT02S036XW ULTIMA, JAQUAR or equivalent make of Philip/ Bajaj/ Wipro/ Osram/ GE/ Havells |
| 62 | Supply and fix smart extruded aluminium LED batten (4 feet) with higher efficiency 1 x 20W, 220V, minimum efficiency 120 lum/watt AC decorative box type with driver, warm/ cool white (as directed by Engineer-in-Charge), double sided connection, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, including taking down existing unserviceable one and removing from site complete all as specified and as directed.Make: Cat No BCLAB 20W LED PS of Bajaj or equivalent make of Philips/ Bajaj/ Wipro. |
| 63 | Supply and fix LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC, minimum efficiency 120 lum/ watt decorative type with warm/ cool white (as directed by Engineer-in-Charge), driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 64 | Supply and fix sub main wiring with using four runs of 10 Sqmm single core multistranded copper conductor PVC insulated and unsheathed (FRLS) cable and two runs of 10 Sqmm single core multistranded copper conductor PVC insulated and unsheathed (FRLS) as earth wire using ISI marked IS 694 1100 Volts grade PVC insulated flexible stranded copper conductor wire drawn through with and including medium grade PVC conduit of size not less than 25mm dia ISI marked of suitable size including conduit fitting and accessories, including end termination with bottle type copper lugs conduit being laid either in ceiling slab or wall or on surfaces or under the frame of the false ceiling including PVC flexible conduit or through wooden partition including clamping arrangement as required including taking down sub main wiring complete all as specified and directed.Note: Four runs of 10 Sqmm cable and two runs of 10 Sqmm earth wire and conduit of suitable size shall be measured as one unit |
| 65 | Supply and fix sub main wiring with using two runs of 6 Sqmm single core multistranded copper conductor PVC insulated and unsheathed (FRLS) cable and one run of 6 Sqmm single core multistranded copper conductor PVC insulated and unsheathed (FRLS) as earth wire using ISI marked IS 694 1100 Volts grade PVC insulated flexible stranded copper conductor wire drawn through with and including medium grade PVC conduit of size not less than 25mm dia ISI marked of suitable size including conduit fitting and accessories, including end termination with bottle type copper lugs conduit being laid either in ceiling slab or wall or on surfaces or under the frame of the false ceiling including PVC flexible conduit or through wooden partition including clamping arrangement as required including taking down sub main wiring complete all as specified and directed.Note: Two runs of 6 Sqmm cable and one run of 6 Sqmm earth wire and conduit of suitable size shall be measured as one unit |
| 66 | Material and labour for Earthing complete with using GI earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level and earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness off 15 cm all around the plate with using galvanised iron wire 4mm dia as earthing lead moulded and retrieved to earth plate at one end and connected to main switch / control board at another end with and including 40 mm dia GI light grade from upper end of earth plateupto external faceof the wall of the building including 20 mm dia bore GI pipe light grade as water pipe from chamber to upper edge of the plate GI funnel with wire mess fixed on water pipe and provision of PCC 1:2:4 type B-1 (Using 20 mm graded stone aggregate) duly reinforced with mild steel round bar 8 mm dia@ 150 mm c/c both ways with 10 mm dia mild steel bars as in liftinghandle with and including necessary excavation and earth work including laying the pipe concealed in floor / wall all as per plate No.3 of SSR Part-I complete all as specified and as directed including testing on completion Note: If the desired resistance is not found earthing shall be done by the contractor at no extra cost to Govt. |
| 67 | Supply and fix GI earth wire as earth continuity conductor of size 4mm dia complete all as specified and as directed. |
| 68 | Supply and fix galvanised iron pipe light grade 15mm bore with all fittings and saddle/ hooks etc for fixing on wall or laid under floor complete all as specified and as directed. |
| 69 | Taking down old unserviceable LT cable of size 50 to 70Sqmm 3.5 core including making good the disturbed surfaces complete all as specified and as directed. |
| 70 | Supply, laying, jointing & testing XLPE Insulated, Screened, PVC Bedded, Galvanized steel strip or wire armoured, Electric Power Cables (heavy duty) with stranded aluminium conductor 1100 volt grade, of size 3.5 core x 70 sqmm, fixed to wall/ floor with saddles/ clamp etc complete all as specified and as directed. |
| 71 | Supply, laying, jointing & testing XLPE Insulated, Screened, PVC Bedded, Galvanized steel strip or wire armoured, Electric Power Cables (heavy duty) with stranded aluminium conductor 1100 volt grade, of size 3.5 core x 50 sqmm, fixed to wall/ floor with saddles/ clamp etc complete all as specified and as directed. |