| 1 | Dismantling of brickwork built incement mortar including all quions, arches, pillars etc. as directed. |
| 2 | Excavating in trenches, in hard/dense soil, n exc 1.5 m wide but exc 1.5 m in depth; for foundationand getting outincluding removing excavated material n exc 50 m and depositing where directed. |
| 3 | Supplying, laying bricks, laid dry, sub class B, laid flat in floor, base.Material & Labour |
| 4 | Casting Cement concrete 1:2:4 Type B-2 (40mm graded aggregate) in foundations, fillings and mass concrete, any thickness, size or shape etc. complete. |
| 5 | Brickwork with sub-class \"B\" bricks, straight or curved on plan exc. 6m mean radius built in : Cement mortar 1:6. |
| 6 | Brick Work with sub class \"B\" bricks, straight or curved on plan to any radius in half brick thick walls built in Cement morter 1:6,complete in all respect. |
| 7 | Reinforced cement concrete work with M-20 (20mm graded aggregates) cement concrete in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; complete. |
| 8 | Steel reinforcement for concrete : Mild Steel TMT barsof 10mm dia and over, cut to length, bent to shape required, binding with and including mild steel wire (annealed) not less than 0.9mm dia., complete in all respect. |
| 9 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter. Rough finished surfaces of concrete . |
| 10 | Supplying, fitting & fixing MS joist, channel, angle tee sections fixed independently.Fe 410 -W(Gde-E- 250) quality-A. M&L |
| 11 | Supplying, fitting & fixing Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm scapings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossing with and provision of galvansied mild steel wire , staples or steel pins etc. as directed complete. |
| 12 | Dismantling of Concrete in ground floors andpavings n exc 15 cm thickness |
| 13 | Casting Cement concrete 1:2:4 Type B-1 (20 mm graded aggregate) in foundations, filling and mass concrete, any thickness, size or shape etc. complete. M&L |
| 14 | Cutting holes in brick walls built in cement mortar exc half brick but n exc one brick for inserting holdfasts and making good in cement concrete 1:2:4 Type-B-I as required. |
| 15 | Supplying, fitting & fixing Rolled Mild Steel in heavy bracket framing (beam, tee,angle, channel, or flat section) as per site requirement and instruction of EIC. Complete in all respect. M&L |
| 16 | Supplying & fixing machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. |
| 17 | Roughening surfaces of oldconcrete floor by picking, sweeping clean and washing down with water to remove dust, etc. including shifting/cleaning the materials from site. |
| 18 | Providing Screed bed or bedding layer of cement mortar (1:4) of 15mm thickness for laying floor tiles on concrete surfacescomplete. |
| 19 | M&L for Glazed ceramic coloured tiles on vertical surfaces of wall such as dados, skirting etc. of size 300x200x7mm thick set and jointed in neat cement slurry and pointed in white cement to match colour of tiles including 10 mm thick backing coat of cement mortar (1:4). |
| 20 | Supplying & Laying of joint free non-skid Ceramic tiles 7 to 8 mm thick, coloured tiles, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc., set and jointed in neat cement slurry and pointed in white or colour cement to match. |
| 21 | ANTI-TERMITE TREATMENT:(a) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron. |
| 22 | ANTI-TERMITE TREATMENT: (b) Providing and injecting chemical emulsion for Post Construction Anti-Termite treatment of soil under existing floors, using chemical using @ 1 litres per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 ( 1 cement:2 coarse sand) to match the existing floors. |
| 23 | ANTI-TERMITE TREATMENT:(c) At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/holes by drilling 6mm dia holes at a downward angle of 45 degree at 250mm centre to centre and sealing the same. |
| 24 | Dismantling & Removal of old Tarfelt (LABOUR ONLY): a) Taking up and removing/lowering of old worn out/damaged tarfelt from roof top at any height, description without damaging the existing roof surface. |
| 25 | Dismantling & Removal of old Tarfelt (LABOUR ONLY): b) Removing of building materials/debris to a distance of 1000 m or part thereof , beyond the lead included in the rates, including loading, unloading and stacking at the earmarked place as directed by E-I-C. |
| 26 | Providing Screed bed or bedding layer of mortar (Apprx. thickness- 40mm at Peak & 20 mm at sides) on concrete surfaces at parapet, roof top with the cement plaster 1:4 including preparing the surface to receive cement mortar grading. Complete as respect as directed by E-I-C. |
| 27 | Providing APP based membrane course roof treatment in layers with following provisions:(i) Applying one coat of bitumenous primer polymerised primer oil based coat, evenly @ 0.5 Kg/Sqm as priming coat to the prepared surface, till the surface is properly impregnated and the solvent oil in the based primer shall be allowed to evaporated completely. (ii) APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified. |
| 28 | Plastering with Cement Morter 1:6, 10mm Thick on fair faces of brickwork & concrete surface after preparing old walls by taking down plaster, any description at any place, position and height complete in all respect. |
| 29 | Supplying, laying,& levelling 40mm thick Concrete floors, pavings in 1:2:4 (12.5mm graded aggregate) laid over cement concrete sub-floors etc.and finished to an even & smooth surface using extra cement. Complete in all respect. |
| 30 | Supplying & Fixing of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete. |
| 31 | Supplying , fitting & fixing sheet glass having thickness 3mm. Size of each glass may n.exc 0.50 sqm. (M&L) |
| 32 | Supplying & Fixing of Steel door including projecting type hinges, steel handle, complete, with glazing bars, dovetailed or welded complete. |
| 33 | Plastering with average 12mm thick plaster on fair faces of brick work or concrete surfaces in Cement Morter 1:6 including taking down Cement plaster on brick walls, concrete surface etc., Plastering is to be finished even and smooth (without using extra cement). |
| 34 | Supplying of integral water proofing compound, for mixing in cement morter in the manner specified by the maufacturer and in the proportions indicated. (Make: Asian Paints-Smart Care Vitalia/Dr.Fixit/Fosroc) |
| 35 | Providing and applying white cement based putty of average thickness 2mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even & smooth. Make: Asian, J&K, Birla. |
| 36 | White Wash:Applying of Two coat of white wash after preparation of old surface by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots. |
| 37 | Supply & applying of two coat of oil bound distemper over one coat alkali resistant priming paint after preparation of old surface by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots. Make: Asian, Berger, ICI. |
| 38 | Painting with one coat of synthetic enamel paint in any wooden old painted surfaces of any description, not otherwise described, over 10cm width or girth after all necessary preparatory work required for the wood surfaces includingknotting and stopping. Make: Asian, Berger, ICI. |
| 39 | Painting with one coat of synthetic enamel paint in old painted steel & iron surfaces of any description, over 10cm width or girth, not otherwise described, including all necessary preparatory work required for the steel surfaces. Make: Asian, Berger, ICI. |
| 40 | Materials & Labour for applying Twocoats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat ofexterior primer applied @ 0.90 litre/ 10 sqm after preparation of old surface by brooming down or steel wire brushing, scraping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots. Make: Asian, Berger, ICI. |