| 1 | M&Lforpreparation of old surfaces and applying two coat of white wash on wall including cornices etc complete all as specified and directed . |
| 2 | M&Lfor preparation of old decorated surfaces of wall, chajjas, soffit of chajja, slab projection etc of any height of bldgs and applying one coat of cement base paint complete as specified and directed . |
| 3 | Complete removal of existing treatment and preparing the surface of walls of any height of bldgs and apply two coat ofcement base paint over a coat alkali resistant primer complete all as specified and directed. |
| 4 | M&L for preparingthe old surfaces and applying one coat of oil bound distemper white or tinted on wallscomplete all as specified and as directed . |
| 5 | M&L for preparation old undeorated wall surfaces by washing ,rubbing down and stoping of distempered or complete removal of existig treatment of any height of bldgsand applying two coat of distemper oil emulsion white or tintedetc allas specified and directed |
| 6 | M&L for preparation ofold wooden surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 7 | M&L for prepartion on old painted surfaces of steel and iron surfaces over 10 cm width or girth and applying one coat of synthetic enamel paintall as specified and directed . |
| 8 | All as per item No 7 here-in-before but surface area n.exc 10CM width or girth |
| 9 | M&Lforpreparation of old surfaces and applying two coat of white wash on ceiling including cornices etc complete all as specified and directed .. |
| 10 | M&Lforpreparation of old decorated ceilng surfaces and applying one coatof distemper oil emulsion white or tinted etc complete all as specified and directed. |
| 11 | M&L for applying one coat of weather proof exterior emulsion paint(1st quality)on walls, chajjas,facia by mechanical applicator of any height of bldigs etc ,including preparing of old surfaces with brooming down or steel wire brushing scrapping down smoke soot moulds moss and efflorescent salts and trading oil and greasy spots complete all as specified and as directed |
| 12 | M&L for complete removal of existing treatment on wall of any height of bldgs by brooming down with wire brushing, stoping andapplying two coats of exterior weather coat under one coat ofprimer by mechanical applicator, complete all as specified and as directed. |
| 13 | Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with with water etc complete all asdirected. |
| 14 | M&L for 15mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces of any height of bldgs and finished the surface even and smooth without using extra cement complete all as specified and directed. |
| 15 | All as per item no 14 here-in-before but in CM 1:4of any height of bldgs mixed withWPC as per manufacturer\"s instruction on fair and even surfaces, Complete all as specified and directed. (WPC will be measured and paid separately) |
| 16 | M&L for 5mm thick rendering inCM 1:3 on ceiling of any height of bldgs, surfaces finished even and fair without using extra cement complete all as specified and as directed. |
| 17 | Supply only integral waterproofing compound ISI Marked |
| 18 | M&L for applying 3mm thick wall care putty to make colours scheme and good or rubbing smooth old diffrent colours paintedwall surfaces completed all as specified and directed |
| 19 | M&L for applying 3mm thick wall care putty to make colours scheme and good or rubbing smooth old diffrent colours paintedceiling surfaces completed all as specified and directed |
| 20 | M&L for preparation of new plastered surfaces and applying three coat of white wash on wall of any height of bldgs all as specified and directed. |
| 21 | M&L for preparation of new surface of wall of any height of bldgs and applying two coat of distemper oil emulsion white or tinted on wall surfaces by and including one coat Primerall as specified and directed. |
| 22 | M&L for preparation of newly plastered ceiling surface of any height of bldgs and applying two coat of distemper oil emulsion white or tinted over one coat chalk whitingall as specified and directed. |
| 23 | M&L for preparation of newly plastered ceiling surface of any height of bldgs and applying three coat of white wash completed all as specified and directed. |
| 24 | M&L for preparation of new plastered surfaces and applying two coats of cement base paint on wall over a coat of primer of any height of bldigs all as specified and directed. |
| 25 | Complete removal of existing treatment and preparing the surface of walls of any height of bldgs with 3mm thick Wall careputty surface finished even & smooth on entire satisfaction of Engr-in-charge and applying two coat of oil bound distemper complete all as specified & directed. |
| 26 | Complete removal of existing treatment and preparing the surface of ceiling of any height of bldgs with 3mm thick Wall care putty and applying two coat of oil bound distemperas directed by Engr-in-Charge at site. |
| 27 | M&L forrepair and rendering 10mm thickin CM 1:3on chajjas, facia, roof projection, column sides, beam bottom and sides including throating after removing cracked plaster and concrete includingcleaning of viisible reinforcementandtreating with cement slurry also necessary repair to cracked concrete upto 60cm wide from bldgs of any height,if any with cement concrete1:2:4 Type B-0 using 12.5mm gradedaggregateincluding necessary scafolding work for double/single storey bldgs,complete all as specified and as directed. |
| 28 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |