Tender For Special Rep To Bldg No P-08 (Single Jcos Living) Of Certain Unit In Northern Sector At Mil Stn Kota; 1 Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed. 2 Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and as directed. 3 Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed. 4 Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed. 5 Taking down existing treatment of any description such as PCC padding, lime concrete, mud phuska etc. and any numbers of layers upto any thickness from roof including scraping and roughening old by picking, sweeping clean and washing down and removing debris outside MD land complete all as specified and as directed. 6 M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate in roof kerbs or mud stops,padding, rounded or chamfered on edges complete all as specified and as directed. 7 M & L for brushing neat cement slurry with 3.0 kg of cement per square meter complete all as specified and as directed. 8 Material & labour for rendering 15 mm thick in cement mortar 1:4 over RCC Roof mixed with water proofing compound @ 3% by weight of cement or manufacturer instruction complete all as specified and as directed. (Note;- water proofing compound shall be measured and paid separately as supply only) 9 Supply only liquid water proofing compoundcomplete all as specified and as directed. 10 M&L for cleaning of roof slab including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over cold applied bituminous primer conforming to IS 3384 @ of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions, complete all as specified and directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, applied@1.20 Kg/Sqm over a coat of cold applied bituminous primer conforming to IS:3384 @ 0.40 Kg/Sqm.(ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii)The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv)In case of stone masonry parapet wall etc a groove of size 25mmx25mm (minimum) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimney/other vertical surfaces and polymeric membrane inserted in groove and sealed with paving bitumen. (v) Cost of above aspects is deemed to be included in quoted rates.(vi) One coat of aluminium reflective paint should be applied on APP after sealing the joints of APP. 11 M & L for brick work with fly ash bricks of class designation 7.5 and non-modular size as per IS 12894: 2002, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed. 12 Material and labour for plastering 15 mm thick on other than fair faces of brick wall or stone surfaces in cement mortar 1:4 with integral water proofing compound finished even and fair complete all as specified and as directed. Note: Water proofing compound shall be measured and paid for separately. 13 M&L for cleaning of walls and floor of sunken portions including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over cold applied bituminous primer conforming to IS:3384 @ 0.40 Kg/Sqm, torching overlaps with a propane or a butane gas torch with an overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold applied bituminous primer all as per manufacturer’s instructions, complete all as directed. Note: (i) The waterproofing treatment shall be got carried out through the manufacturer or their authorized applicators only. (ii) HDPE spout pipe 32mm bore of required length shall be provided and rates for same shall be included in above quoted rate. 14 Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed. 15 Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed. 16 Material and labour for plastering 20 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement mixed with and including water proofing compound as per manufacturer instructions complete all as specified and as directed. 17 Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces on ceilings in cement mortar 1:3 finished even and fair complete all as specified and as directed. 18 M & L for preparing plaster surfaces of walls treated with 1mm thick putty and applying acrylic distemper in two or more coats, VOC less than 50 gms/ litre as per IS 101 (Part 2/Sec 2), matt finish, medium washability, of approved shade, over a coat of primer as per the manufacturer’s instructions, applying using brush, keeping the gap/ the interval in subsequent coats, including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed.Note: - The paint shall be as per Tractor Uno Acrylic Distemper of Asian Paints or equivalent of Make mentioned under Appendix B. 19 Complete removal of existing treatment and preparing plaster surfaces of walls treated with 1mm thick putty and applying acrylic distemper in two or more coats, VOC less than 50 gms/ litre as per IS 101 (Part 2/Sec 2), matt finish, medium washability, of approved shade, over a coat of primer as per the manufacturer’s instructions, applying using brush, keeping the gap/ the interval in subsequent coats, including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed. Note: - The paint shall be as per Tractor Uno Acrylic Distemper of Asian Paints or equivalent of Make mentioned under Appendix B. 20 M & Lfor preparation of newly plastered surface and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm complete all as specified and directed. 21 Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 Sqm over new surfaces complete all as specified and directed. Note :- Premium acrylic emulsion pain should be done as per following processer :-(i) complete removal of existing treatmentforpreparation of old decorated treatment on wall / ceiling / chajja by scrapping with trucare wall sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7/9 to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etccomplete (ii) After that and applying one coats ofAnti fungal weather proof grade exterior acrylic emulsion paint of approved tint over a coat of approved primer as per manufacturers instractions weather proof primer with crack filling upto 5 bars of positive hydrostatic pressure on vertical walls without any dilution with forced coverage not more than 3.5 sqm / ltr as per manufacturers instructions and all coats including primer to be applied with fully automatic airless spray machineof paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI or manual application. Allow 6-8 hrs to dry the surface in subsequent coats of paint complete all as specified and as directed.(iii) MAKE :- dulux weather shield max/Nerolac Excel Everlast 12/Asian paint ultima protek / Berger weather coat long life 10 orTechno commercially equivalent makes specified in PS. 22 Preparation of newly plastered surfaces on ceilings and applying three coats of white wash complete all as specified and as directed. 23 M&L for preparing old surface of ceiling, plastered or unplastered by brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts andtreatingoil and greasy spots & applying one coat of white wash etc complete all as specified & as directed. 24 S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and as directed. 25 S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed. 26 Dismantling of wrought or mild steel work of any description not otherwise described into primary parts complete all as specified and directed. 27 S & F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge and as per specification & drawing as applicable to item 08100A given in SSR Part – II (2020). (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Make:-Rajshri/Sintex/Accucel/Duraplast 28 S & F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge and as per specification & drawing as applicable to item 08100A given in SSR Part – II (2020). (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Make:-Rajshri/Sintex/Accucel/Duraplast 29 S&F for factory made 30mm thick 100% Solid WPC ( Wood polymer Composite) Laminated Flush Door Shutter of required size comprising ofvirgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, (maximum toxicity index of 12 for 100 grm ) made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm, having good screw holding capacity ( Screw Withdrawal strength of 1800 N ( Face ) & 900 N ( Edge ), Minimum Compissive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pastedon both faces of shutterand fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company :For WC/Bathroom/Toilet/Kitchen/Balcony Doors. Make:-Rajshri/Sintex/Accucel/Duraplast 30 S&F for factory made 35mm thick 100% Solid WPC ( Wood polymer Composite) Laminated Flush Door Shutter of required size comprising ofvirgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, (maximum toxicity index of 12 for 100 grm ) made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm, having good screw holding capacity ( Screw Withdrawal strength of 1800 N ( Face ) & 900 N ( Edge ), Minimum Compissive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pastedon both faces of shutterand fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company :For WC/Bathroom/Toilet/Kitchen/Balcony Doors. Make:-Rajshri/Sintex/Accucel/Duraplast 31 S&F for factory made 35mm thick 100% Solid WPC ( Wood polymer Composite) Laminated gauged type door Shutter of required size comprising ofvirgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pastedon both faces of shutterand fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company :For WC/Bathroom/Toilet/Kitchen/Balcony Doors. Make:-Rajshri/Sintex/Accucel/Duraplast 32 S&Fwindows made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM) and Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 52x 25mm. Outer frame & mullion sections to have rebate for glazed shutters. Fly mesh with 20 mm GI flat beading for provision of guard bars/ grills. Fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy duty stainless steel pivot hinges shall be provided per shutter. The windows should be paneled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter with 0.36mm dia of wire and 1.40mm aperture. Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 12mm square guard bars with 110mm spacing c/c (Horizontal bay) to be welded on FI 20x6mm alaround except runner portion complete all as specified and directed. 33 S&Fventilator with top wire mesh shutter and bottom fixed frosted glass made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM) and Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 52x 25mm. Outer frame & mullion sections to have rebate for glazed shutters. Fly mesh with 20 mm GI flat beading for provision of guard bars/ grills. Fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap. Elixir or equivalent stay, handles 2nos of heavy duty stainless steel pivot hinges shall be provided per shutter. The windows should be paneled with 4 mm thick plain float glass and S.S. Mesh for fly mesh shutter with 0.36mm dia of wire and 1.40mm aperture. Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 12mm square guard bars with 110mm spacing c/c (Horizontal bay) to be welded on FI 20x6mm alaround except runner portion complete all as specified and directed. 34 S&F 17-19 mm thick modular membrane kitchen cabinet door shutters and shelves (made out of HDHMR boards) in wood grain colour and half round edges, complete all as specified and directed. 35 S&F 16-18 mm wide & 1mm thick PVC edge banding pasted to edges of PVC furniture with suitable adhesive, complete all as directed. 36 S & F auto close hinges three dimentional adjustment with suitable mounting plate of extruded brass with nickel plated for corrosion resistance, bright finished for cubboard and cabinet shutters complete all as specified and directed. 37 S & F brass alloy handle, fabricated type, 100 mm size, nickel chromium plated finish as per service grade number 2 of IS 1068: 1993 complete all as specified and as directed. 38 S & F 100 mm size medium weight stainless steel butt hinges made out of cold rolled complete all as specified and as directed. 39 S & F stainless steel handle cast moulded type anodised 150 mm size fixed with screws complete all as specified and as directed. 40 S & F stainless steel barrel tower bolts of extruded section 200mm long complete all as specified and as directed. 41 S & F mild steel door spring of rat tail type of size 300 mm, bright finish including roller and roller plate complete all as specified and as directed. 42 S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 250 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed. 43 S & F in renewal floor door stoppers made out of aluminium alloy pressure die casting body and tongue with hard drawn steel wire spring, overall length of cover plate 140 mm, 4.5 mm thickness of cover plate, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, suitable for 30 & 35 mm thickness of door shutter, fixed in floor complete all as specified and as directed. 44 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 45 Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc.complete all as specified and as directed. 46 Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. 47 Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. 48 M&L Glazed ceramic coloured tiles on vertical surfaces 350x 250x7 mm/450X300X7mm/ 300X600X7-8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including 10 mm thick rendering in CM 1:4 backing, complete all as specified and directed. Make :- Kajaria (Impression)/Johnsons (Elite Plus)/ Somany (Juene Glossy). 49 M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size graded crushed stone aggregate, 25 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed. 50 M&L for joint free non skidceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6,complete all as specified and directed. Make :- Kajaria Pavigres matt finish/Johnsons Elite plus Matt Finish/ Somany Plain star Beige Matt Finish. 51 M&L for joint free non skid matt finishceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6,complete all as specified and directed. Make :- Kajaria (Matt finish)/Johnsons (Matt finish)/ Somany (Matt finish). 52 M&L for joint free non skid matte finishceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm fixed on vertical surfaces as skirting, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 10 mm thick rendering in CM 1:4 backing, complete all as specified and directed. Make :- Kajaria (Matt finish)/Johnsons (Matt finish)/ Somany (Matt finish). 53 M & L for green marble work 16 to 18 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like including laying over 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and as directed. 54 M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. 55 M & L for 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates, laid in alternate panel, finished surface even and fair including filling in position with 85/25 industrial grade bitumen mix filler of proportion 80 kg of hot bitumen, 1 kg of cement and 0.25 cubic metre of coarse sand as in plinth protection complete all as specified and as directed. 56 Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed. 57 Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed. 58 Dismantling water tanks capacity exceeding 250 litres but not exceeding 500 Litres and removing to store complete all as specified and as directed. 59 Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 60 Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. 61 S & F rotational moulded polyethylene tripple layer water tanks, white colour (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed. 62 S & F ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed. 63 S & F in repairs 600 mm X 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. 64 S & F in repairs wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed. 65 S & F in repairs vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed. 66 S & F in repairs 10 litres capacity, low level, syphonic type, white, plastic flushing cistern as per IS 7231: 1994 with inlet, ball valve, float and handle including brackets and 40 mm nominal dia high density polyethylene pipes for flush pipe complete all as specified and as directed. 67 S & F in renewal flushing jet CP for pedestal pattern WC including flexible pipe and brass chromium plated nuts and bolts and water pipe of size 1150 mm long complete all as specified and directed 68 S & F in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed. 69 S & F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed. 70 S & F in repair towel ring of PTMT fixed with and including chromium plated brass screws and wooden / plastic cleats (Minimum weight of 90 Gms) complete all as specified and as directed. 71 S & F in repairs 20 mm nominal size, screw down stop valves, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed. 72 S & F in repairs 15 mm nominal size, screw down stop valves, cast copper alloy body and body components with crutch handle, bright finished complete all as specified and as directed. 73 S & F in renewal of 15 mm wall mixture three in one with complete accessories complete all as specified and directed.Make :- CERA cat part No F1001411/ Jaquar cat part No QQP 7273PM/ Hindware cat part No F 740022 ortechno commercially equivalent make specified in PS. 74 S & F in renewal of Bib taps 15mm dia,chromium plated, long body,with CP flange all as perfixed in repairs complete all as specified and as directed. Make :- CERA cat part No G 1017152 /Jaquar cat pat no VGP-81037/ Hindware cat part No F 740011or techno commercially equivalent makes specified in PS. 75 S & F in repairs 15 mm nominal size, nonrising spindle type fancy pillar taps as per IS 8931: 1993, cast copper alloy body with knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed. 76 S & F in repairs 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant complete all as specified and as directed. 77 S & F stainless steel soap dish weight not less than 150 gm each fixed to plugs with chromium plated brass screws complete all as specified and as directed. 78 S & F in repairs brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed. 79 S & F in repairs grating round 140 mm size of PTMT (Minimum weight) complete all as specified and as directed. 80 M & L in repairs for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed. 81 S & F in repairs stainless steel curtain rod made out of stainless steel sheet of grade X 02Cr19Ni1O (304 S2), surface finish No. 4 as per IS 6911: 2017, 25 mm dia including brackets and holders etc. complete all as specified and as directed. 82 Dismantling of cast iron or reinforced concrete drain pipes of size 75mm /100 mm jointed in cement mortar and taking out of trenches, if required complete all as specified and as directed. 83 S & F cast iron, centrifugally cast, socket and spigot, nominal dia 100 mm soil, waste and vent pipe as per IS 3989: 2009 in any length with cement joints, laid in trenches or in floors complete all as specified and as directed. 84 S & F cast iron, centrifugally cast, socket and spigot, nominal dia 75 mm soil, waste and vent pipe as per IS 3989: 2009 in any length with cement joints, laid in trenches or in floors complete all as specified and as directed. 85 S & cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) without access door for soil, waste and vent pipes of nominal size 100 complete all as specified and as directed. 86 S & F cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) without access door for soil, waste and vent pipes of nominal size 75 complete all as specified and as directed. 87 S & F cast iron, centrifugally cast, socket and spigot, nominal dia 75 mm soil, waste and vent pipe as per IS 3989: 2009 in any length with cement joints, fixed to walls incl necessary clamps, nuts, bolts etc. and making good the disturbed surface as per existing complete all as specified and as directed. 88 M & L for cast iron floor trap 75 mm nominal diameter with grating including jointing to waste pipe with lead joints and including necessary concreting in M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 89 S & F cast iron Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches without access door for soil, waste and vent pipes of nominal size 100 mm complete all as specified and as directed. 90 S & F cast iron vent cowl for 100 mm bore pipe complete all as specified and as directed. 91 M & L for glazed stoneware square mouth gully trap, P type, size 150 X 150 including setting and jointing to drain with cement mortar 1:1 complete all as specified and as directed. 92 Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position, above or below ground floors, not otherwise specifically provided for complete all as specified and as directed. 93 M & L for RCC M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in chajjas complete all as specified and as directed. 94 M & L for RCC M20 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. 95 M & L for RCC M20 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and as directed. 96 M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed. 97 M & L for mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed. 98 M & L for formwork to chullah hoods, chajjas, troughs and similar items including edges for fair finished flat surfaces of concrete complete all as specified and as directed. 99 M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions for fair finished flat surfaces of concrete complete all as specified and as directed. 100 M & L for 16-18 mm thick granite of black colour (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over and including 20 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. Note- The quoted rates shall be inclusive of - (i) Moulding of front and side of slab including polishing. (ii) Granite shall be laid in single piece of any size with rounding of edge and a groove shall be provided beneath the projection portion of slab. (iii) Gas pipe hole should be provided in kitchen slab. 101 M & L for providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment along external wall where the apron is not provided using chemical emulsion in water of one percent Chlorpyrifos 20 EC at the rate of 7.5 litres per sqm of the vertical surface of the sub-structure to a depth of 300 mm including excavating channel along the wall and rodding etc. complete all as specified and as directed. 102 S & f in renewal sign board with stainless steel frame of any size with 3mm thick ACP sheet one side visibility with digital art work ( letter, numbers, signs, symbols, etc. ) retro reflective Type IV high intensity prismatic grade sheeting in twin colours conforming to IRC 67- 2022, digitally colour printed as directed to be fixed on stainless steel frame. The frame shall be fixed in PCC 1:2:4 type B1 incl necessary excavation and earthwork complete all as specified and directed. NOTE- (i) Writing letters, numbers, signs, symbols, etc shall be deemed to be included in quoted rates. (ii) SS frame shall be measured and paid separately under appropriate item . 103 Material & Labour for providing and fixing stainless steel (grade X 02Cr19Ni1O, 304 S2, surface finish No. 4 as per IS 6911: 2017) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed. 104 S&F snake guard (door seal Aluminium plate with rubber beading) for door of approved size and shape etc complete all as specified and directed . 105 Dismantling posts or struts (wood, steel or RCC.) any section embedded in concrete, brick work, masonry, etc., including taking out embedded portion and making good disturbed ground complete all as specified and directed. 106 Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed. 107 Dismantling fencing wire mesh, any type complete all as specified and as directed 108 M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. 109 S & F hot rolled low tensile structural steel of grade E165 as per IS 15911: 2010 as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar works complete all as specified and as directed. 110 Supply only 10 mm dia mild steel Gde E-250 plain round bars as in line wire for chain link fencing complete all as specified and as directed. 111 Supply only galvanized steel chain link fence fabric of any mesh size, made out of any nominal dia mesh wire, heavy zinc coating type conforming to IS 2721: 2003 complete all as specified and as directed. 112 Fixing only galvanized steel chain link fence fencing including line wires any mesh, size and type to any type of standards, rails, straining bolts, etc. including provn of binding wire complete all as specified and as directed. 113 S & F mild steel screw bolts (machine made), diameter of neck 11 to 15 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5 cm long complete all as specified and as directed. 114 Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. 115 Preparation of newly or previously untreated steel surface of any description not exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. 116 M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed. 117 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658: 2021 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 25 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed. 118 Providing and laying at or near ground level factory made kerb stone of any size, top bullnosed shape, made of M-25 (Design Mix) grade cement concrete, in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. 119 M & L for precast cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed. 120 Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) of internal dia 150 mm, set in cement mortar complete all as specified and as directed. 121 M & L for concrete bed to drain pipes of internal diameter 150 mm laid in trenches in cement concrete M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate including packing under and haunching against the sides of pipes complete all as specified and as directed. 122 Supplying and laying reinforced concrete pipes with collars, 150 mm internal diameter, class NP2, laid and jointed with stiff mixture of cement mortar (1:2) complete all as specified and as directed. 123 Cutting into existing manholes for connecting new drains of pipe of nominal size 150 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate, smooth finished, and reforming benching as required complete all as specified and as directed. 124 Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and as directed. 125 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. 126 Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 127 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, wall light fittings , tube light fittings, surface light fitting , ceiling light fittings , any types of fittings etc. removing materials to store for keeping in safe custody or for taking on credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. 128 Taking down main switch/MCB/MCCB/MCB DB/ MCCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed. 129 Taking down existing old fluorescent tube light fittings/ bulk head light fittings/ ceiling light fittings/ building light fittings including lamp any capacity, any type complete all as specified and as directed. 130 Taking down old unserviceable submain wiring 1.5 sqmm or 2.5 sqmm or 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number including batten/conduit/ casing capping including removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface to match the existing surface complete all as specified and as directed. 131 M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and including providing concealed MS sheet metal sunken switch /Terminal box 1.2mm thick for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate. 132 M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and including providing concealed MS sheet metal sunken switch /Terminal box 1.2mm thick for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate. 133 M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and including providing concealed MS sheet metal sunken switch /Terminal box 1.2mm thick for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate. 134 M & L for point wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and including providing concealed MS sheet metal sunken switch /Terminal box 1.2mm thick for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate. 135 M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and including providing concealed MS sheet metal sunken switch /Terminal box 1.2mm thick for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. Note :- Cutting chases and making good to match with the adjoining surface deemed to be included in the unit quoted rate. 136 S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 137 S & F switch socket combination with (3 pin and 3 pin) having two earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 138 S & F buzzer, din dong, suitable for single phase, AC, 240 volts complete all as specified and as directed. 139 S & F bell push, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed. 140 S & F 3 pin socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed. 141 S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed. 142 S & F ceiling roses, 6A, 240 V, terminals for the connection of live, neutral and protective earthing conductors, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed. 143 Taking down ceiling fan 1200/1400 mm sweep / exhaust fans 300mm/ geyser of capacity upto 50 Ltr including disconnection of electric connection and deposited in E/M store yard complete all as specified and as directed. 144 S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed. 145 S & F ceiling fan, AC, 50 Hz, single phase, 230 V, 1200 mm sweep, minimum air delivery 210 m³ per minute, minimum service value 6 m³ per minute per watt, 3 Nos metal blades protected with corrosion resistance paints, with brushless DC motor having electronic controllers that use sensors, ISI marked including capacitor to ensure power factor more than 0.9, five star rating as per Bureau of Energy Efficiency including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose of Make- Havells Cat No FHCNF5SWHT48 or Bajaj at No Energos26 251100EE or Orient Cat No FALCON BLDC or techno commercially equivalent makes specified in PS incl writting of MES srl No with black colour paint as provided by AGE E/M complelete all as specified and directed. Note- Fan down rod of suitable size upto 3 meter length shall be included in quoted rate. 146 Supplying, installing, testing & commissioning, Storage Geyser, five star rated, 25 litres Capacity, steel body with stainless steel inner tank material, shock proof, auto cut, on-off indicator, thermoplastic body, corrosion free with safety valve, fusible plug, thermal cut out including fixing by grouting and fastener complete all as specified and as directed. 147 S & F exhaust fan, AC, 50 Hz, single phase, 230 V, 300 mm sweep, 4 pole, heavy duty, metal body, 4 Nos blades, Insulation Class A, ISI marked including capacitor to ensure power factor more than 0.9 including louvers and all fixing accessories including making hole for fixing of exhaust fan of suitable size and making good the disturbed surface as per existing complete all as specified and directed. 148 Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and as directed. (Note 1- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be measured and paid separately.) 149 S & F LED tube light with built-in batten nominal power 18 Watt LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 1600, lumen efficacy of minimum 90 lumens per watt, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 4 KV, protection grade IP 20, THD below or less than 33%, CW available CCT of 6000K, power factor of minimum 0.90, polycarbonate housing, life span of minimum 50000 working hours complete all as specified and as directed. 150 S & F LED tube light fitting 2 feet 10 watts including tube with high power LEDs as light source and electronic driver complete all as specified and as directed. 151 S & F LED streetlight/ building security light nominal power 45 Watt, 230 V AC, outdoor type with aluminium pressure die-cast housing, polyester powder coated, IP 65/66 protection complete with in-built integrated electronic LED driver including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. 152 M & L for bracket made out of GI pipe 40 mm dia medium grade, 1.5 metre long bent to shape with MS flat iron clamps made out of 40 mm X 6 mm thick mild steel nuts, bolts including taking down existing GI bracket complete all as specified and as directed. 153 S & F double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.Make- Legrand Ekinox3 series/ Schnieder Easy 9 series/ ABB Cat No ISYP021604C0001 or equivalent technocommercially equivalent make as specified in PS. 154 S & F single door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. Make- Legrand Ekinox3 series/ Schnieder Easy 9 series/ ABB Cat No ISYP011608C0001 or equivalent technocommercially equivalent make as specified in PS. 155 S & F miniature circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6 A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. 156 S & F miniature circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. 157 S & F miniature circuit breakers (MCB), four pole with three protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed. 158 S & F sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB SPN 32 Amps 240 volts complete all as specified and as directed. 159 M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed. 160 Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed. 161 Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling, hand punning down complete all as specified and as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly. 162 M & L for laying of bricks locally available sub class B bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and as directed. 163 Supplying & laying in trenches 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.