Tender For Special Repair To Bldg No P-28 Or Md Accnat Ahrrunder Ge E/M Rr Hosp. Delhi Cantt-10; 1 Demolition of brick work or stone masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles all as specified. 2 M&L for brick work with sub class B Bricks (using old size bricks) straight or curved on plan exc 6m mean radius built in CM 1:6, complete all as specified and as directed. 3 Taking down cement plaster of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed. 4 M&L for 15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finished even and fair without using extra cement, complete all as specified & directed. 5 M&L for 15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4, finished even and fair without using extra cement, complete all as specified & directed. 6 M&L for rendering 10 mm thick in cement and sand mortar 1:3 on concrete surfaces of ceiling, including finishing the surface even and fair without using extra cement complete all as specified. 7 M&L for applying two coats of cement base wall care putty 1.5mm avg thick on plastered surface of wall and making the surface even & smooth for receiving distemper/ paint of any description, complete all as specified & directed. 8 M&L for applying two coats of cement base wall care putty 1.5mm thick on plastered surface of ceiling and making the surface even & smooth for receiving distemper / paint of any description, complete all as specified & directed. 9 M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper, complete all as specified & directed. 10 M&L for preparation of newly plastered surfaces of walls and applying two coats of exterior grade weather proof paint over a coat of weather resistant acrylic primer, complete all as specified and directed. 11 M&L for preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper, complete all as specified and as directed. 12 M&L for complete removal of existing treatment on old plastered surfaces of walls and applying two coats of oil bound distemper, complete all as specified & directed. 13 M&L for complete removal of existing treatment on old plastered surfaces of walls and applying two coats of exterior grade weather proof paint, complete all as specified and directed. 14 M&L for complete removal of existing treatment on old plastered surfaces of ceiling and applying two coats of oil bound distemper, complete all as specified and as directed. 15 Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing) and rubbish off the premises, complete all as specified & directed. 16 M&L 15mm thick screed bed or bedding layer in cement mortar (1:6) for laying floor finishes, complete all as specified & directed. 17 M&L 10 mm thick screed bed or bedding layer in cement mortar (1:4) to receive wall tiles, complete all as specified & directed. 18 M&L for non skid colour ceramic tiles 7-8 mm thick (square/rectangular) area of each tiles exceeding 0.06Sqm but not exceeding 0.11Sqm, in floors etc, setjointed in neat cement slurry & pointed in coloured cement to match complete all as specified and directed. 19 M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in dado/ skirting etc, set and jointed in neat cement slurry and pointed in coloured cement to match, complete all as specified & directed. 20 M&L for coloured glazed ceramic wall tiles as in vertical surfaces of size 600mm x 300mm x 7 to 8 mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specified & directed. 21 Taking down chowkats or frames including shutter (without taking off shutters from the frame) area not exc 1.50 Sqm each, complete all as specified. 22 Taking down chowkats or frames including shutter (without taking off shutters from the frame) areaexc 1.50 Sqm but n.exc 4.00 sqm each, complete all as specified. 23 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screwshaving minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardantand fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames,minus 5mm tolerance indimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 24 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screwshaving minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardantand fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.Note: For WPC solid door/window frames,minus 5mm tolerance indimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 25 S&FProviding and fixing factory made single extruded WPC(Wood Polymer Composite) solid decorative type flush door shutter of size35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moistureproof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge. 26 Supply and fixing 30mm thick FACTORY MADE WIRE MESH SOLID WPC DOOR SHUTTER conssisting of density 650 Kg/Cum manufactured by an ISO-9001-2015 certified company. Door to be panelled with SS mosquito and XTN aluminium mesh for additional strengh and safety purpose (Confirming as per IS 4020). The door should be water proof, termite proof, fire retardant and having screw holding capacity. Door to be fixed to frame with 3 Nos. SS butt hinges size 100mmx25mmx2mm and 33mm long steel screws drilled suitable to pass through other hardwares should be fixed with 19x6mm size steel screws. etc. complete all as specified & directed. Note:- (i) MTC and Screw out test will be provided by contractor.(ii) SS butt hinges shall be paid in other item. 27 S&F for steel windows/ventilators fabricated from roll formed section made of galvanized steel color coated powder coated ( base steel as per sqm IS-513 D quality galvanized as IS 277 with zinc coating of 120 GSM with total coated thickness of 0.60mm. The coated section shall be with primer coated of primer of -7 microns thick, finish painted with a polyster paint of 12.16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure plyster powder upto 50-60microns thick with the following specifications (a) Main frame 72mm x 55mm x 0.58mm (b) Mullion 72mmx50mmx0.58mm (c) Glazed/gauzed shutter frame 47mmx20.20mmx0.58mm (d) Glass beats beads size 12mm x 12mmx0.58mm Accessories. Easch shutter shall be provide the following fiting (a) Stainless steel pipe of hinges 01 set(b) Alumminium powder coated handle -04 Nos. Glass panes Glazes shutter and fixed glass of 5.00mm thick float glass. WIRE MESH -Stainless stell wire mesh of 0.3 mmnomonal dia wire and average width of aperature 1.40mm. Grills window shall be provide with grill made of 10mm square MS bars welded to 12mmx6mm thick MS plate. Distance between bars should no be more than 12cm c/c. Total grill unit shall be enamel painted and fixed to window frame screw. Note: The glazes/ Guaged shutter includingguard bars shall be measure once i.e as per area of opning. No seprate payment of seprate shutter i.e. Glazed and fly proof and guard bars shall be made. Area of shutter shall be the area of opening. The rate quoted by the contracter is deemed to inclusive of all specified in Drg No- CEDZ/TD/289 sheet 1 R/2 and 2R/2. 28 S&F framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework ofwater tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified & directed. 29 S&F 100 mm long butt hinges, medium weight, cold rolled stainless steel and fixed, complete all as specified. 30 S&F 100 mm long, stainless steel barrel tower bolts of extruded section complete all as specified and directed. 31 S&F 100mm size extruded Stainless steel handles, fabricated type complete all as specified and directed. 32 S&F stainless steel, sliding door bolt 300mm length with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections, complete all as specified & directed. 33 S&F 150 mm long, stainless steel barrel tower bolts of extruded section complete all as specified and directed. 34 S&F 150 mm long stainless steel handle of extruded section fabricated type anodised and fixed, complete all as specified and directed. 35 S&F mild steel ordinary rat tail rod pattern springs including roller and roller plate complete 300mm length, complete all as specified and directed. 36 S&F in repairs stainless steel curtain rod 20-22mm dia including brackets, side knobs etc, fixed to walls, complete all as specified and directed. 37 S&F floor door stopper of dia cast SS alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor of overall length 140mm, complete all as specified and directed. 38 Demolition of stone slabs and tiles of any description or thickness in floors etc laid, bedded and pointed in any mortar, complete all as specified & directed. 39 M&L for 16-18mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified & directed. 40 Taking up or down 20mm bore steel tubing and connections, complete all as specified & directed. 41 All as per ser item No. 40 here-in-before but 25mm bore. 42 Supplying and laying of CPVC pipe 20mm dia SDR 11 and plain CPVC SDR 11 brass fittings on walls/ceilings or laying in floors including all necessary fittings complete all as specified. 43 All as per ser item No. 42 here-in-before but 25mm bore. 44 Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks etc, complete all as specified & directed. 45 S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or floors/ wall incl necessary clamps if reqd, complete all as specified & directed. 46 S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls,including PVC Clamps complete all as specified & directed. 47 M&L for PVC floor trap of 75mm dia of outlet, plain with grating including jointing with solvent cement, including embedding with PCC 1:2:4 type B-1, complete all as specified & directed. 48 S&F 110mm bore PVC (SWR) bends any radius, complete all as specified & directed. 49 S&F in repair white vitreous china wash hand basin (flat back) of size 550 x 400 mm fixed on and including new brackets complete including 32 mm size brass chromium plated waste coupling, PVC waste pipeetc, complete all as specified and directed. 50 S&F in repair European vitretious china wash down water closet pan P or S Trap (excluding flushing cistern but including flush pipe and pvc seatcover white). 51 S&F in repairs PVC low level flushing cistern, valve less, Syphonic action type, double push bottom, 9-10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 32 mm dia of required length and makingconnection completeall as specified. 52 S&F in repairs bib taps, cast copper alloy, fancy type, with crutch or butterfly handle, chromium plated, screwed down, screwed for iron pipe or for brass ferrule of 15mm bore, complete all as specified & directed. 53 S&F in repairs stop valves/angle valve, cast copper alloy, fancy type, chromium plated with long shank & cup (concealed type), with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15mm bore, complete all as specified & directed. 54 S&F in repairs PVC connections 15 mm size with PTMT nuts of length 600mm, all as specified & directed. 55 S&F in repairs 600 mm x 450 mm size bevelled edge mirror 5 mm thick of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified & directed. 56 S&F in repair tubular towel rail stainless steel chromium plated 20 mm dia D type 60 cm long between flanges, including brackets and fixed to walls, all as specified and as directed. 57 S&F in repairs soap dish, brass CP any type, fixed to plugs with chromium plated brass screws, complete all as specified and directed. 58 S&F in repairs shower rose, with shower rose arm plated brass, fancy type, 125 mm with or without swivel joint, any size, including fixing to steel pipe or union, complete all as directed. 59 S&F in repairs sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified & directed. 60 S&F waste coupling of PTMT (half or full threaded), minimum weight 60gms, suitable for discharge pipe of 40mm bore dia, complete all as specified & directed.all as specified. 61 S&F in repairs kitchen plate rack made of stainless steel 1 mm thick with plugs washers asoverall size of 75cm x 75 cm including fixing to wall and all accessories, complete all as specified and directed 62 Supply and fix in repair 500 litres capacity double layer, rotational molded, polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including 20 mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe including dismantling tank, complete all as specified and directed. 63 Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, complete all as specified. 64 M&L for 75 mm thick PCC type C-2, 1:3:6(using 40 mm graded stone aggregate) as in plinth protection laid in bays n. exc. 2 sqm each, finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 grade and 3 parts of sand (all by weight) complete all as specified and as directed by Engineer-in-Charge. 65 Demolition of cement concrete (reinforced) of any description and as in kitchen slabs, shelves, chimney, Chajjas etc not other specifically provided for complete all as specified and directed. 66 M&L of RCC of nominal mix type B0 1:2:4 (12.5mm graded aggreate) as in chajjas and like all as spd and directed by Engr-in-charge. 67 S&F brass CP wall , sink, washbasin mixer for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified. 68 S&F in repairs 20mm bore of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to pipe all as spd and directed. 69 S&Ffactory made 18mm thick 100% solid WPC(Wood Polymer Composite) laminated board of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moistureproof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutterand fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer In- Charge. 70 M&L for followings :-(i) Removing plaster & finishes from all exposed / damaged portion of coloumns, slabs & beams(ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible)(iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed)(iv) Cleaning exposed concrete substrate by using water jet.(v) Removing visible rust along the length of reinforcement using hand tools as approved.(The Engr-in-charge may order sand blasting if rust is approved)(vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out complete all as specified and directed. 71 M&L for providing rust proof /anti corrosive treatment to bars :-(i) cleaning of all exposed bars (new & old) alround(ii) Apply a single coat of Alkaline rust converting primer on alround bars of any girth new & old as recommended by the manufactuer(iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating. 72 M&L for providing PMM (Polymer modified cementitious mortar) :-(i) Dry sub strate surface and free of debris and dust(ii) Applying Epoxy bond coat on the sound substrate using approved apray machine & ensuring that no pin holes are visible (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes).(iii) Immediately after application of epoxy bond coat as above apply PMM (Polymer modified cementitoius mortar) of 25-50mm thickness.Note : Application of PMM sghall of preferably be in coats of approx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed within 30mins). PMM shall be pre packed ready to use.(iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufacturer cmplete all as specified and directed. 73 S&F 100mm dia cast iron (spun cast) soil, waste and vent pipes in any length, with or without ears, with leadjoints, fixed to walls including dismantling old pipes any type complete all as specified and directed. 74 S&F 75mm dia cast iron (spun cast) soil, waste and vent pipes in any length, with or without ears, with leadjoints, fixed to walls including dismantling old pipes any type complete all as specified and directed. 75 S&F in repair 100 mm dia cast iron bends/Tee/diminishing piece with or without oval access doors for spun pipes (any radious)with polymer jointing materials, complete all as specified and directed. 76 S&F in repair 75 mm dia cast iron bends/Tee/diminishing piece with or without oval access doors for spun pipes (any radious)with polymer jointing materials, complete all as specified and directed. 77 M&L for jointfree Non - skid coloured Ceramic tiles 7 to 8 mm thick area of eachtile(600x600mm) exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchcomplete all as specified and directed. 78 Demolition of cement concrete (unreinforced)/lime concrete/sunken floor of any description and in any position not otherwise specifically provided for by mechanical means (like drill machine, Hilti, pneumatic chisel, etc) complete all as spd & directed. 79 M&L PCC 1:5:10 Type E-2 (using 40 mm graded stone aggregate )in mass concrete for sunken portion of WC,complete all as specified and directed. 80 M & L for Water proofing treatment of sunken RCC slab : (i) 15mm thick plater in CM (1:3) mixed with WP compound as per manufacturers instructions shall be provided on sunken portion while the concrete is green.(ii)Apply cement slury @ 0.488 kg/sqm cement mixedwith Acrylic based polymer modified cementious composite compound@ 0.253 kg/sqm and the surface will be allowed to air cure for 4 hours. (iii)Apply another layer of cement slurry @ 0.242 kg/sqm of cement mixed with Acrylic based polymer modified cementious composite compound @ 0.126 kg/sqm and the surface will be allowed to air cure for 4 hrs. (Make of cement composite compound of Dr. Fixit/Fosroc/Sikka)(iv)Curing the sunken portion with water minimum for 7 days by ponding.(v)Paste 200micron thick poythene film of approved make with approved adhesives to the treated sunken surface.(vi)Joints/Traps/WC/Soil pies shall be properly sealed with approved sealing compound of approved make.(vii)Testing of all traps & joints shall be done after sealing and before filling of sunken slabs and ponding test for 96 hours. (viii)Spout pipe shall be provided for drain out the water in sunken portion.Note: Flat surface shall be measured for payment. 81 M&L for TMT bars 6 to 8mm dia cut to length bent to shape required including cranking, bending etc and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified & directed. 82 S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screwshaving minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/ moisture proof and fire retardantand fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames,minus 5mm tolerance indimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 83 S&F in repair of SS auto closing hinges openable at 0 degree for kitchen cabinet shutters and bed room cub boards complete all as specified. 84 S&F in repair ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed complete all as specified. 85 S&F in repair Grating doom 100mm dia of SS (Minimum weight 35gms) all as spd and directed by Engg-in-Charge. 86 M&L for 25mm thick PCC 1:2:4 TYPE B0 using 12.5mm graded stone aggregate in sub baseof floor complete all as spd and directed. 87 S&F Grating doom 125 mm dia with waste hole of SS (min wt 50gm) all as spd and directed by Engg-in-Charge 88 M&L for Preparation of new or previously untreated steel surfacesof any description not otherwise described over 10cm width or grith and applying two coat of synthetic enamel paint over a coat of red oxideprimer completeall as specified. 89 M&L for providing cement concrete 1:2:4 type B-I (20mm graded agg) in roof kerb or mud slops, rounded or chamfered on edges, coping, kneelers, kerb water tough and the like incl weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified & directed. 90 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safecustody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. 91 M & L point wiring for modular switches with 1.5 Sqmm, PVC insulated, unsheathed, multistranded,copper conductor Cable, FRLS, 1100 Volt grade, including 1.5 Sqmm size, PVC insulated, unsheathed, copper earth continuity conductor, connected to earth dolly, drawn through and including concealed, rigid non-metallic PVC Conduit of minimum 20 mm dia or higher asper site requirement with all fittings such as GI metal flush box suitable for modular switches / sockets / fan regulators with cover plates, blanking plates, brass / cadmium plated screws, cup washers etc including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete all as specified and directed for the followings :- 92 (a) One light/fan/bell/exhaust fan point controlled by one switch. 93 (b) One 3 Pin socket outlet 5 Amps on Independent board. 94 (c) One 3 Pin socket outlet 5 Amps on same board. 95 (d) One light point controlled by two, two way switch 96 All as per srl item No. 91 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 15 Amp power point. 97 All as per item No.91 above but wiring with 4 sq mm FRLS copper wire for industrial socket outlet 3 pin 20 / 25 Amps point and one single core 4 sq mm FRLS PVC insulated unsheathed copper cable as earth continuity conductor. 98 S & F Modular Switch 1 way 16 A, 1 Module complete all as specified and directed 99 S & F Modular Socket 6 / 16 A - 2/3 Pin combined 2 module complete all as specified and directed 100 S & F Modular Switch 1 way 6 /10 A, 1 Module complete all as specified and directed. 101 S & F Modular Socket 6 / 10 A - 2 / 3 Pin combined 2 module complete all as specified and directed. 102 S & F Modular Switch 2 way 6 / 10 A, 1 Module complete all as specified and directed. 103 S & F Modular fan regulator step type, 120W 2 Module complete all as specified and directed. 104 S & F of Ceiling rose surface Polycarbonate type with three terminals 240 Volts complete all as specified and directed. 105 S & F Modular bell push 6 A, 1 Module 106 S & F of Electric bell, ding-dong, AC 230 Volts, Single Phase 107 S & F in replacement of Modular AC Box,power socket with top240 volts AC complete with one SP MCB, 20 amps concealed / flush to wall surface complete all as specified and directed. 108 S & F in replacement of LED tube lightfitting 20 watt (CW), 4 feet long in extruded aluminium batten with high efficient LEDs available in milky diffuser and Colour Rendering Index (CRI>70), IP20, correlated Colour Temperature (CCT- 5700K to 6500K), PF>0.9 and Voltage rated 220V to 240V complete all as specified and directed. 109 S & F in replacement of LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V, AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 110 S & F in replacement of LED light Bulkhead fitting 1x9W / 1X10W, luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. 111 S&F surface mounting LED building security light fitting fitted in high pressure die cast aluminium housing not less than 35 W including fabrication of GI bracket 25mm dia suitable for fixing of LED light fitting duly fixed with clamps, nut bolts & washer etc.Fixture should have minimum efficacy at system level >=120 lumens/Watt, life of fixture not less than 50K Hrs,Ripple<5%,UGR<19,minimum Surge protection level of 4 KV, CCT 4000-6500K with same lumens/w CRI>80, PF>0.95 ,THD<10% @ 240v Ac with IP 66 protection.An operating voltage Range of 140-270V including all connection upto ceiling rose complete all as specified and directed. 112 Taking down unserviceable sub main wiring of aluminium any type with earth wire and making good disturbed surfaces of wall/ floor or roof etc and applying putty complete all as specified and directed. 113 M & L Sub main wiring with 2 x 6 Sqmm and 1 x 6 sqmm (for earth) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including regid PVC conduit 20 mm dia or higher, complete with all conduit accessories and connected with thimble from main DB / Panel to sub DB complete all as directed.Note :1. The two run of 6 Sqmm wire, one run of 6 Sqmm wire (for earth) and 1 mtr PVC conduit pipe will be measured as one unit. 114 M & LSub main wiring with 2 x 4 Sqmm and 1 x 4 sqmm (for earth) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including regid PVC conduit 20 mm dia or higher, complete with all conduit accessories and connected with thimble from main DB / Panel to sub DB complete all as directed.Note :1. The two run of 4 Sqmm wire, one run of 4 Sqmm wire (for earth) and 1 mtr PVC conduit pipe will be measured as one unit. 115 S & F indistribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of RCCBs / MCBs and isolators etc and making all necessary connections complete all as directed. 116 S & F inDistribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, surface mounting, VTPN 04 way, 415 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCBs / MCBs and isolators etc and making all necessary connections complete all as specified and directed. 117 S & F in replacement RCBOs, SPN, 40 Amps capacity, 240V, 100 mA with earth leakage protection complete all as specified and directed 118 S & F in replacementMCB SP 40 Amps capacity, 415V, 100 mA with earth leakage protection complete all as specified and directed 119 S & F in replacement MCB, SP, 6 to 32 Amps capacity, 240V, B Curve type, 10kA, single pole with over load and short circuit protection complete all as specified and directed 120 S & F in replacement MCCB, 415 Volt, 16kA, 4 pole, 100 Amp capacitywith over load and short circuit protection complete all as specified and directed 121 Take down water heater storage type of any capacity carefully and reflexing complete with new fasteners and all accessories complete all as directed 122 Taking down carefully ceiling / exhaust / wall fan of any size, sealing cable end, dismantling blades & removing fan and blades deposited to MES store complete all as directed. 123 Painting of ceiling/Exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as directed 124 Labour for Taking down of electric meter with boxof any make and type from the site and depositing it to the MES store all as specified and directed by Engr-in-Charge. 125 S&Fof hot press moulded SMC meter box of inside dimensions 400x300x190 mm with hinged doors fixed in walls alongwith exisiting meter and making good to the disturb surfaces complete all as specified and directed. 126 M & L Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground earth pit not less than 2.25 mtr deep below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all by means of nuts and bolt check nuts and washers of galvanised iron sheet all as shown in electrical plate Nos 5 of SSR Part - I and connected to and including earthing test point complete including testing filling of adequate quantity of charcoal dust and common salt including refilling earth and removal of surplus soil up to 50 mtrs PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made but at 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 83260.0 /-
Tender Value
INR 41.63 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail