}

Providing And Fitting, Fixing Of Internal House Electrical Wiring, Lighting Lumineries, Installation Of Centrifugal Pump-Motor Set And Other Allied Electrical Works At Baruipara Pump House Under Kanksa Zone-Ii , Phase-Ii W/S Scheme, Block- Kanksa, kanksa-West Bengal

Public Health And Engineering Department has published Providing And Fitting, Fixing Of Internal House Electrical Wiring, Lighting Lumineries, Installation Of Centrifugal Pump-Motor Set And Other Allied Electrical Works At Baruipara Pump House Under Kanksa Zone-Ii , Phase-Ii W/S Scheme, Block- Kanksa. Submission Date for this Tender is 04-08-2025. Electrical Products Tenders in kanksa West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

50162409
Providing And Fitting, Fixing Of Internal House Electrical Wiring, Lighting Lumineries, Installation Of Centrifugal Pump-Motor Set And Other Allied Electrical Works At Baruipara Pump House Under Kanksa Zone-Ii , Phase-Ii W/S Scheme, Block- Kanksa
Tender
Indian
West Bengal
Kanksa
04-08-2025

Tender Documents

Tender Details

Providing And fitting, Fixing Of Internal House Electrical Wiring, Lighting Lumineries, Installation Of Centrifugal Pump-Motor Set And Other Allied Electrical Works At Baruipara Pump House Under Kanksa Zone-Ii , Phase-Ii W/S Scheme, Block- Kanksa- 1 Supply and Delivery of Following Materials at site:- 2 a )Supply & delivery and storage at site 7.0 m Swaged Type StreetTubular Pole (M.S) complete with all accessories like Base Plate, Cap & 1.0 m M.S Single arm bracket generally conforming to IS: 2713-1980 and as per technical specification given bellow :-Over all length - 7.0 M Length x out side dia. X thickness of different section :Bottom 4M x 114.5mm x 4.50mm-Middle 1.5M x 88.9mm x 4.05mm-Top 1.5M x 76.1mm x 3.25mm.-The above pole is provided with suitable size base plate & 1.0 m long of 40mmdia. M.S. Following Double Arm Brackets and pole as per designation 410-SP-02 & conforming to relevant I.S. ( Make: INDIAN TUBE CO/BANSAL/ Calcutta Poles & Tubes Co.). T.C. Needed. 3 70 Watt. LED Highly efficient IP66 LED street-light with aluminium pressure die-cast housing, toughened glass in the front and peanut lens for batwing light distribution,higher spacing between poles and maintenance-free system.(Model-LSFS-070-C,Make-Orient). (For Yard Lighting). 4 45 Watt. LED Highly efficient IP66 LED street-light with aluminium pressure die-cast housing, toughened glass in the front and peanut lens for batwing light distribution,higher spacing between poles and maintenance-free system.(Model-LSFS-070-C,Make-Orient). (For Pump House). 5 4 ft. long 22 Watt LED Tubelight Slim LED batten with aluminium housing and polycarbonate diffuser is an ideal replacement solution for existing battens/fluorescent lamps with elegantlydesigned end caps.(Make-Approved Make) 6 4 Core X 16 Sqmm, 1.1 KV Grade XLPE insulatedAl.Ar Cable.( From LT MCC Panel feeder to DBs)(Make:-Approved Make) 7 4 Core X 6 Sqmm, 1.1 KV Grade XLPE insulatedAl.Ar Cable.( For Outdoor Street Light to DB Box)(Make:-Approved Make) 8 450 mm Sweep exhaust fan 220V-240 V,50 Hz, Single phase.(Make:-Approved Make) 9 3 CoreX 2.5 Sqmm industrial flexible copper cable wire/dia-30/0.25 PVC insulated with PVC sheathed.(Make:Approved Make)(For 2 Nos 70 Watt Street light from Loop Box Roof of the each Pole to Street Light) 10 100 Watt High efficiency round LED high-bay luminarie with aluminium die cast housing with high lumen efficiency of>130 lm/Watt, a perfect energy-saving solution with IP65 Protection.(Make-Approved Make) 11 100 A TPN Main Switch with Re-wireble fuse link within sheet steel enclosure.(Make- Approved Make) 12 Supplying and fixing double door 8 Way Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(With 40 Amp TPN MCB as a incomer + 8 Nos 10 Amp MCB as a Outgoing)(Make-Havells, Model No-DHDPTODRW08) 13 Supply of 25 mm dia GI Conduit 1.6mm thick.(Approved make) 14 Supply of GI Bend/Elbow. 15 Supply of GI saddle etc … 16 Two way Circular Box & cover. 17 One way Circular Box & cover. 18 Labour for fitting and fixing 25 mm dia 1.6mm thick G.I. Conduit above ground (exposed) in the wall with previously supplied saddle clamps including cost of jointing materials,holder bat clamps etc.,as necessary, including cutting pipe, making threads etc. complete in all respect with two coats of painting with approved paint any height. 19 Supplying and Drawing 1.1 KV single core stranded FRPVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. 20 3 X 22/0.3(1.5 Sqmm).(For lighting Fixtures) 21 3 X 36/0.3(2.5 Sqmm).(For Exhaust Fans+Highbay Light) 22 3 X 56/0.3(4 Sqmm).(For industrial Plug Sockets) 23 Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages tobuilding works. 24 12 Module. 25 Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required. 26 Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. 27 Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A,SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. 28 Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection onthe top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.(For Yard Light) 29 Fixing outdoor type fluorescent/SV/MV light fitting on pole including S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium) bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated and sheathed wire (single core) from loop box at the base of pole to light fiting through pole & bracket (without control switch) including making connections &painting.(For 3 Nos Street Light obove pump House) 30 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:45 cm (18). 31 Fitting & fixing of the outdoor lighting luminaries along with new & old accessories to the pole and sub-station building etc as per direction of EIC. (For 2 Nos 70 Watt Street Light at Pole). 32 Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long).(2 Nos for Pump House) 33 Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc. 34 Fixing only Floodlight/High Bay Fitting with suitable tie clamps and MS plate for mounting top of the Ceiling or similar structure. 35 Supplying and Fixing GI water proof looping cable box havinghinged GI Top Cover having 4 mm thick with rubber gasketlining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below,Comprising of one 250 V,15 A Kit-Kat fuse unit, one NL on,porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1)after dismantling the damaged looping cable box etc. where necy. incl. painting. 36 200 x 150 x 100mm.(For 2 Nos 70 Watt Street Light at Pole & 3 Nos 45 Watt Light above Pump House) 37 Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.(For Flowmeter & Level Indicator) 38 Connecting the pole to earth busbar including S & F GI(Hot Dip) wire of size as below,spiral on pole body as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. 39 No. 12 SWG. 40 Earthing with GI earth spike(1822mmX20 mm) and grouted the same under the ground level as per direction. 41 Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finishand GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly a) Upto 9.0 mtr. Size 0.6x0.6x1.70 mts 42 Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.45x0.45x0.60 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) incl. drilled hole in pole suitable for alkathene/polythene pipe entry, for street light wiring, without Loop Box 43 Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint. A) Upto 9.0 mtr. long pole. 44 i) 1st coat of aluminium paint over 1 coat of RO priming 45 ii) 2nd coat of aluminium paint over 1st coat 46 Pumping-Machineries Installation Portion at High Lift :- 47 Supply and delivery of following materials at site:- 48 Supply, Delivery and storage at site of horizontal Split casing Centrifugal Pumping Machinery with Channel Base Frame, Couplings, Coupling Guards, Companion Flanges, foundation bolt etc. with Horizontal foot Mounted, TEFC, Induction Motor, duty with adequate margin as per direction of EIC.M.O.C. for Pump:-a) Volute Casing-C.I.b) Impeller-BR IS:318 GR-LTB-2c) Shaft - SS410, d) Shaft Sleeves-SS410e) Discharge-172 M³/Hour, Head-40 Mtr.(H-Q-P Curve of Pumps has to be submitted during the delivery)(Make:- Kirloskar/Wilo/Mather & Platt /Other approved make)Specifications for Motor:-a) 30KW(4 Pole, 3 Phase Induction Motor)b) Rotational Speed-1480 RPMc) Colling Type-TEFCd) Operating Voltage-415 V±10%, Frequency- 50 Hz ± 5%.e) Efficiency Class-IE-3(Make:-Approved make) 49 Supply, Delivery and storage at site of horizontal Split casing Centrifugal Pumping Machinery with Channel Base Frame, Couplings, Coupling Guards, Companion Flanges, foundation bolt etc. with Horizontal foot Mounted, TEFC, Induction Motor, duty with adequate margin as per direction of EIC.M.O.C. for Pump:-a) Delivery Casing-C.I.b) Impeller-SSc) Shaft - Carbon steel e) Vaccum-upto 600mm Hg,Air Flow Rate:upto 65M3/Hr(H-Q-P Curve of Pumps has to be submitted during the delivery)(Make:- Kirloskar/Wilo/Mather & Platt /Other approved make)Specifications for Motor:-a) 3.7KW(4 Pole, 3 Phase Induction Motor)b) Rotational Speed-1500 RPMc) Colling Type-TEFCd) Operating Voltage-415 V±10%, Frequency- 50 Hz ± 5%.e) Efficiency Class-IE-3(Make:-Approved make) 50 3½ Core X 35 sqmm Aluminum Armored, XLPE insulated 1.1 K.V. grade cable, conforming to IS 7098(I) as per direction of EIC. (Make:-Gloster/Mescab/Polycab/other approved in vendor list.)(For Individual induction Motor)(Test Certificate is to be submitted at the time of delivery.) 51 4 Core X 10 sqmm Aluminum Armored, XLPE insulated 1.1 K.V. grade cable, conforming to IS 7098(I) as per direction of EIC. (Make:- Approved in vendor list.)(For Vaccum Pump).(Test Certificate is to be submitted at the time of delivery.) 52 Installation,Testing & Commissioning of above items no 30.01 to 30.04 including construction of Pump foundations, necessary pipe and valve support,laying of cables with necessary jointing materials, earthing arrangement including supply of all erection items etc.as required for complete installation as per relevant standard & IE rules in compliance with specification of NIT and upto entire satisfaction of EIC. 53 Add GST @ 18% 54 Add CESS @ 1%

Key Value

Document Fees
Refer document
EMD
INR 30000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail