Tender For Repair Maintenance Of Cloth Drying Hall At Lekhapani Grn Of Hq 25 Sect Ar; 1 Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m.for all kind of soil 2 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. for all kind of soil 3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 4 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in cement mortar 1:6 (1 cement : 6 coarse sand) 5 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 6 Supplying and stacking at site 63 mm to 45 mm size stone aggregate andLaying, spreading and compacting stone aggregate of specified sizes , applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . 7 M/LCement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. 8 Labour only forSteel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes (Pipe supplied by dept.) 9 Supply and Fixing of Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 10 Fixing only precoated galvanised iron sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 micronsminimum to avoid scratches during transportation and should besupplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(Pipe supplied by dept.) 11 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) 12 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade One or more coats on old work 13 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet,suitable size M.S. box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor single core cable etc. asrequired 14 Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wireof FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 15 Wiring for circuit/ submain wiring alongwith earth wire with the2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wireof FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 16 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required 17 Supplying and drawing 3 x 1.5 sq. mmsizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 18 Supplying and drawing 3 x 2.5 sq. mmsizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 19 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.(i) 5/6 amps switch 20 (ii) 3 pin 5/6 amp socket outlet 21 (iii) 15/16 amp switch 22 (iv) 6 pin 15/16 amp socket outlet 23 Supplying and fixing 2 way stepped type electronic fan regulator230 volt AC on the existing switch box including connections as required 24 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 25 Supplying and fixing metal box of 75 mm X75 mm X 60 mm deep (nominal size) n surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 26 Supplying and fixing metal box of 200 mm X250 mm X 60 mm deep (nominal size) n surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 27 Supplying and fixing metal box of 100mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch,connections, painting etc. as require 28 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required 29 Supplying and fixing 6 way , Double door, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator 30 Supplying and fixing 12 way , Double door, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolato 31 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, Ccurve, miniature circuit breaker suitable for inductive load of Single pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required 32 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, Ccurve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required 33 Supplying and fixing 63 Amps , double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 34 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steeletc. as equiredenclosure,surface or in recess, with chained metal cover for the socket out on let and complete with connections, testing and commissioning 35 Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 4 sq. mm + 1 X 4 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 36 Wiring for circuit/ submain wiring alongwith earth wire with the 2 X6 sq. mm + 1 X 6 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 37 Supply & Fix recess mounted LEDRounded /Squre down light fitting suitable for false ceiling, 15 watt, white light, metal body with white colour outer finish and acrylic diffuser including LED driver / transformer, spring loaded clips for easy mounting completeMake Havells/Philips / Wipro /