}

Tender For Supply Installation Testing Comissioing Of 11/0.4Kv 500 Kva Dtr Copper Wound Opposite To Warden Complex At Assam University Silchar. - 1C X120sqmm Unarmored 1.1 Kv Grade Al Cable 2 Dtr Cubical For 500 Kva Dtrs Comprising Of Requisite One No T, silchar-Assam

Assam University has published Tender For Supply Installation Testing Comissioing Of 11/0.4Kv 500 Kva Dtr Copper Wound Opposite To Warden Complex At Assam University Silchar. - 1C X120sqmm Unarmored 1.1 Kv Grade Al Cable 2 Dtr Cubical For 500 Kva Dtrs Comprising Of Requisite One No T. Submission Date for this Tender is 16-07-2025. Transformer Supply Tenders in silchar Assam. Bidders can get complete Tender details and download the document.




Tender Notice

50110502
Tender For Supply Installation Testing Comissioing Of 11/0.4Kv 500 Kva Dtr Copper Wound Opposite To Warden Complex At Assam University Silchar. - 1C X120sqmm Unarmored 1.1 Kv Grade Al Cable 2 Dtr Cubical For 500 Kva Dtrs Comprising Of Requisite One No T
Tender
Indian
Assam
Silchar
16-07-2025

Tender Documents

Tender Details

Tender For Supply Installation Testing Comissioing Of 11/0.4Kv 500 Kva Dtr Copper Wound Opposite To Warden Complex At Assam University Silchar. - 1C X120sqmm unarmored 1.1 KV grade Al cable 2 DTR cubical for 500 kVA DTRs comprising of requisite one no TM based MCCB/ACB for incoming and three TM release MCCB/FN for outgoing , Static TVM , CT Vmeter, Ameter, LED pilot lamp indicator complete with bus bar etc. 3 GI earthing pipe 50mm dia 3m length ,3.15 mm thickness with perforated holes of 15 mm dia at 30 cm interval along the pipe 4 Supply, installation & testing of G.I. Plate earth station with600 mmx600 mmx6 mm heavy duty G.I. earth plate withnecessary 40 mm dia. G.I. watering pipewith G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mmhinged cover C.I. cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . 5 GI trip 25X3mm for DRT earthing 6 GI trip 50X6 mm for DRT neutral earthing 7 11/0.4KV 500 KVA DTR Copper Wound - BIS Level certified 8 GI Steel Tubular Pole SP-60 9 ll KV DO Fuse Set 200A Assembly 10 11 KV 400A GOAB switchcum horn type fuse set 11 Disc insulator (Poly) 70 KN (T&C) 12 Pin insulator poly 5 KN 13 LT pin insulator 14 LT Guy insulator 15 LT shackel insulator 16 GI 11 KV T Cross arm with angle size 50X50X6 mm 17 GI channel cross arm (100X50X6X2200)mm 18 GI channel cross arm (100X50X6X2800)mm 19 GI channel cross arm (100X50X6X3200)mm 20 LT angle cross arm (40X40X6X500)mm 21 11Kv 5KA LA (Line type Distribution class) 22 Transformer oil EHV grade insulating oil 23 H/W fitting for disc insulatorT&C 70kN tension type 24 LT GI Shackel strap with bolts 25 DTR fencing as per REC standards specification complete with labour and materials. 26 Earth filling with river sand including watering leveling compacting grading etc including payment for forest royalty and other duties as per site condition and technical specification. 27 Grouting and mufflerring of steel tubular pole as per specification and drawing with minimum planting depth of 2.15 mtr 28 Grouting and mufflerring of 8.5 mtr pole as per specification and drawing with minimum planting depth of 1.5 mtr 29 Grouting of stay set with PCC and boulder 30 DTR fencing including all material complete with RCC footing beam ,brick wall etc as per specification Rates include all material and labour. 31 Transformer pad for 500 KVA distribution transformer complete 32 Testing of transformer: Testing of transformer performing following test in presence of department representative.(i)Open circuit & short circuit testing to determine transformer losses (ii)Oil die-electric strength test(iii)Winding resistance test complete and as directed by department. 33 Supplying and erection of L.T. stay set complete (Galvanizewith 19mm dia x1.8m long stay rod anchor plate of size 30cm x 30cm x 6.4 mm thimble stay clamps tube buckle (19mmx 60c 7/14 SWG dia G.I stay and strain insulation etc. in cement concrete 1:3:6:(1Cement:3Course sand:6graded stone aggregate 40mm nominal sizefoundation including excavation and refilling etc. as required and as directed by the department. 34 Supplying and erection of H.T. stay set complete (Galvanizewith 19mm dia x1.8m long stay rod anchor plate of size 30cm x 30cm x6.4 mm thimble stay clamps tube buckle (19mmx 60c 7/3.15 mm dia G.I stay and strain insulation etc. in cement concrete 1:3:6:(1Cement:3Course sand:6graded stone aggregate 40mm nominal sizefoundation including excavation and refilling etc. as required and as directed by the department. 35 Supplying and string up of 3 Ph , 3 Wire AAAC/ACSR Racoon conductor in the existing P.S.C./ M.S/ Galvanized pole with binding etc. as required and as directed by the department. Directed by the department. 36 Any other SOR item based on APDCL SOR 2021-22.

Key Value

Document Fees
INR 2500 /-
EMD
INR 68810.0 /-
Tender Value
INR 34.40 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail