Tender For Provision Of Different Offrs Md Accn At Ahmedabad Mil Stn - 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No.29 2 Lump sum price worked out by the contractor for SITE CLEARANCE, EXCAVATION & EARTH WORKas listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 30 3 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 31 4 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 32 to 36 5 Lump sum price worked out by the contractor for ROAD/FOOT PATH/ CULVERT WORKS as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 37 to 40 6 Lump sum price worked out by the contractor for AREA DRAINAGE WORKSas listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 41 7 Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES B/F from Sl page No. 43 8 Lump sum price worked out by the contractor for COMPOUND WALL , FENCING AND STEEL GATE WORKSas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No.44 to 46 9 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKSas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 47 10 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKSas listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 48 to 51 11 Sch A PART-XI (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule. 12 INTERNAL WATER SUPPLY OFFR ACCN Md Accn Supply and fixing of15 mm dia fancy type chromium plated bib taps with wall flange,screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed.Make - Jaquar Cat part No.VGP-81037 or equivalent of any make specified in Appx C. 13 Supply and fixing of15 mm dia fancy type chromium plated pillar cock with wall flange,screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed.Make - Jaquar Cat part No. ORP-10001PM-7037 or equivalent of any make specified in Appx C. 14 Supply and fixing 15 mm borefancy type chromium plated central hole basin mixerwith popup waste system wiyh 450 mm long braided hosesfor iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed. 15 Supply and fixing of 15 mm dia fancy type chromium plated angular stop cock screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed.Make - Jaquar Queen series Cat part No.QQT-7053 or equivalent of any make specified in Appx C. 16 Supply and fixing of 15 mm bore CP wall mixer of 3 in 1 system with provision for hand shower and over head shower and including 1.5 m long tele shower screwed for iron pipes or CPVC pipes or for brass ferrule and fixed complete all as specified and directed.Make - Jaquar Queen series Cat part No.QQT-77281 orequivalent of any make specified in Appx C. 17 Supply and fixing for 15 mm bore fancy type chromium plated single lever sink nixer with swinging spout on upper side (wall mounted modle) with connecting legs & wall flanges and fixed complete all as specified and as directed.Make - Jaquar Queen series cat part No. FON-40165orequivalent of any make specified in Appx C. 18 Supply and fixing for overhead shower 150x150mm of square shape single flow with rubit cleaning systemABS body crome plated with grey face plate with arm having swivel joint chromium plated complete all as specified and as directed.Make - JaquarQueen series cat part No.OHS-35495 or equivalent of any make specified in Appx C. 19 Supply and fixing health faucet (ABS Body) with 1200 mm long flexible mild steel tube 15 mm dia with wall hook and complete all as specified and as directed.Make - JaquarQueen series cat part No.ALD-573 or equivalent of any make specified in Appx C. 20 Servant Md AccnSupply and fixing of15 mm dia fancy type chromium plated bib taps with wall flange,screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed. Make - Jaquar/Essco Seriesor equivalent of any make specified in Appx C. 21 Supply and fixing of 15 mm bore fancy type chromium plated sink cockwith swinging spout (Wall mounted Model) With Connecting Legs & wall fllanges and fixed complete all as specified and as directed.Make - Jaquar/Essco Seriesor equivalent of any make specified in Appx C. 22 Supply and fixing of 15 mm dia fancy type chromium plated angular stop cock with wall flange, screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed. Make - Jaquar/Essco Seriesor equivalent of any make specified in Appx C. 23 Supply and fixing of15 mm bore Overhead shower of 114 x 114 mm of square shape single flow with rubit cleaning system ABS body crome plated with grey face plate with arm having swivel joint chromium plated complete all as specified and as directed.Make - Jaquar/Essco Seriesor equivalent of any make specified in Appx C. 24 INTERNAL ELECTRIFICATIONSupply and fixing load line distribution board TPN vertical, 4 way double door type, fixed on wall semi flush with incoming MCCB 4 pole 200 Amps, 16 KA, busbars ,neutral link, blanking plates complete with all accessories all as specified and as directed by Engineer-in-Charge. Note: Outgoing MCBs shall be measured and paid separately 25 Supply and fixing TV sockets complete with all accessories all as specified and as directed by Engineer-in-Charge. 26 Supply and fixing RJ 11 Gang with shutter (Telephone Jack) complete with all accessories all as specified and directed by Engineer-in-Charge 27 Supply and fixing wall mounted fan 450mm sweep,5 star rated with speed regulater,less noice, PVC body,180 degree rotated ,all including connection with single core PVC insulated but unsheathed, FRLS cable with multistranded copper conductors IS 694 marked, from ceiling rose to fan complete all as specified and as directed by Engr-in-Charge. 28 Supply & fixing of PVC metal braided connection pipes for hot water supply with brass adopters 15 mm dia and 450mm long complete all as specified and as directed. 29 Supply & fixing LED lampB22 base 10 W, min lumen output 950 lumens at 6500 K CCT for batten holderscomplete all as specified and as directed. 30 Supply and fixing of decorative, wall mounting, brushed nickel finish fixture with opal glass diffuser suitable with 9 W LED lamp B22 base including all electrical connections complete all as specified and as directed 31 M & L for inverter point wiring for one light, ceiling fan and 5 Amp socket for each roomwith 2.5 sqmm, PVC insulated, unsheathed, single core multistandard copper conductor cable ( FRLS), 1100 volts grade including 2.5 Sqmm PVC insulated, unsheathed, copper conductor cable for earth continuity wire to be drawn through in and including PVC conduit medium grade ISI markedwith its acessories upto the main DBand 15 A switch socket combination with gang box flushed in wallfor inverter power supplycomplete all as specified and as directed. 32 Supply and fixing of LED security light fitting made out of pressure die cast aluminium powder coated housing high impact resistant 4mm thick toughened glass cover and matrix of power LEDsinbuilt electronic driver up to 4KV surge protection fitted with adjustable pole adapter to enable on site tilt angle setting depending on road geometry CCT5500-6500 CRI greater than 70 , input power 30Woutput operating voltage 140-280V with connection by three core PVC insulatedmultistranded copper conductor sheathed cable of size 1.0 sq mmfixed with & including bracket made of GI pipe 40mm bore light grade, 1.6 mtr long bent to shape required with 2 no MS clamps of suitable size and length, nuts & boltscomplete all as specified and as directed. 33 M & L for drawing 12 pair /multi core coated copper telephone cable including PVC conduit of size 20mm complete all as specified and as directed by Engr-in-Charge 34 M&L for bringing approved earth from outside defence land for filling in the site of the work including necessary excavation, transportation and payment of rolyalt etc to bodies complete all as specified and directed. 35 COMPOUND WALL , FENCING AND STEEL GATE WORKSSupply and fixingof CI wheel as rollers of 75mm dia for gatescomplete all as specified and as directed. 36 EXTERNAL WATER SUPPLY WORKSSupply and fixing of 80 mm Gun-metal, globe or gate valves, with iron wheel head , screwed both ends for iron pipes complete all as specified & directed. 37 M&L forconstruction of brick masonarry new valve pit chamber of size 600mm x 600mm x 600mm (internalsize) with 100mm thick PCC 1:4:8 type D-2 lean concrete foundation using 40mm graded crushed stone aggregate providing well burnt brick masonary wall of 23 mm thick built in cement mortar 1:6rendering in cement mortar 1:6 finished even smooth using extra cement internally and 20mmthickin cement mortar 1:4and finished fair and even supply and fix 3.15 mm thick MS sheet steel cover fixed on 50mmx 50mmx 6mm thick angle ironframe embbeded in PCC copingwith locking arrangement and 1 Nos 50mm size 4 levers lock with key in duplicate Standard size and MS hold fast and handle made out of 25 x 6mm flat iron appplyingtwo coats of synthetic enamel paint of approved shade over a coat of primer (Red Oxide) to all exposed surface making good all disturbed surface to match surrounding complete all as specified and directed. 38 M & L for Cutting existing cast iron pipes 150mm dia and reducing to required length in position for insertion of new tees, branches, S&F of CI Tee 150x150x80mm all flanged fixing to existing pipe by providing two Numbers Mechanical joints of 150mm size complete with nut bolts, gasket all as specified and as direcetd by Engineer In Charge 39 EXTERNAL ELECTRIFICATION WORKSSupplying, installing, testing and commissioning of AC 3 phase, 50 HZ, 250 KVA capacity transformer, step down, outdoor type, 11000/433 volts (at no load) with system voltage 12KV all as per IS 1180 (Part 1):2014, copper wound, oil immersed, naturally cooled with external cooling tubes, ONAN Cooling, core type, delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector group-4) with neutral brought on secondary (LV) side & having tappings in equal steps of 2.5 % from (+) 5% to (-) 10% on primary side by means of hand operated off load tap changing gear, so as to change/correct L.T voltage on secondary side including provision of all necessary / standard fittings all as per IS:2026 & IEC 76 Latest ammendments and confirming to BEE 5 Star Rating (Level 3 transfomer) as per IS 1180 (Part 1):2014 with all necessary arrangments and comprising of following :- 40 (a) The core shall be stack/wound type of high grade Cold Rolled Grain Oriented or Amorphous Core annealed steel lamination having low loss and good grain properties, coated with hot oil proof Inter layer insulation of Nomex /Epoxy dotted Kraft Paper, bolted together and to the frames firmly to prevent vibration or noise. The core shall be stress relieved by annealing under inert atmosphere if required.The complete design of core must ensure permanency of the core loss with continuous working of the transformers. LV winding shall be such that neutral formation will be at top. Current density for HV and LV winding should not be more than 2.8 Ampere per sq mm(b)The maximum allowable losses at 75 °C & 50% of rated load and total losses at 100% of rated load shall not exceed the maximum total loss 864watts and 2488watts respectively for 11/0.433 kV transformer without any positive tolerance all as per specified for level 3 transformer as in IS 1180 (Part-1):2014 Ammendment No 4(c) Overload capacity of transformers shall be suitable for loading as per IS 6600.(d) The percentage impedance of transformers at 75 °C for 250 kVA shall be 4.5% ,as per Table 6 of IS 1180 (Part-1) : 2014 (e) Transformer tank construction shall conform in all respect to clause 15 of IS 1180(Part-1):2014. The internal clearance of tank shall be such, that it shall facilitate easy lifting of core with coils from the tank without dismantling LV bushings. All joints of tank and fittings shall be oil tight and no bulging should occur during service. Inside of tank shall be painted with varnish/hot oil resistant paint.The top cover of the tank shall be slightly sloping to drain rain water. The tank plate and the lifting lugs shall be of such strength that the complete transformer filled with oil may be lifted by means of lifting shackle.Manufacturer should carry out all welding operations as per the relevant ASME standards. The transformer tank shall be of robust construction and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for the bottom and top and not less than 4 mm for the sides for distribution transformers with Tolerances as per IS-1852.The space above oil level in the tank shall be filled with dry air or nitrogen conforming to commercial grade of IS 1747. The tank shall further be capable of withstanding a pressure of 0.8kg/sq.cm and a vacuum of 0.7 kg/sq.cm (g) without any deformation. 41 (f) Audible sound levels for liquid immersed distribution transformers shall be 56 decibels (NEMA Standards)(g) One cable box on primary H.V side having cable glands suitable for 95Sqmm 3 core XLPE 11 KV H.T cable consisting of 3 Nos porcelain H.T bushings with brass/ gun metal bushing rods confirming to IS 2099 and IS 3347 for outdoor bushing complete with nuts and washers.HT Cable box should prevent the ingress of moisture into the box due to rain water directly falling on the box. The cable box on HT side shall be of the split type with faces plain and machined and fitted with Neo-k-Tex or similar quality gasket and complete with brass wiping gland to be mounted on separate split type gland plate with nut-bolt arrangement and MS earthing clamp. The bushings of the cable box shall be fitted with nuts and stem to take the cable cores without bending them. The stem shall be of copper with copper nuts. The cross section of the connecting rods shall be stated and shall be adequate for carrying the rated currents. On the HV side the terminal rod shall have a diameter TS for 3 Phase DT 11 of not less than 12 mm. The material of connecting rod shall be copper. HT Cable support clamp should be provided to avoid tension due to cable weight. (h) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushings complying to IS 7421 with GMbushing rods complete with GM nuts, and washers with cable gland suitable for reception of outgoing L.T. PVC sheathed armoured cables of size 2 x 300 sqmm 3.5 core . having non-magnetic material gland plate with appropriate sized single compression brass glands on LV side to terminate 1.1 kV/single core XLPE armoured cable.(j) The bushing rods and nuts shall be made of brass material 12 mm diameter for both HT and LT bushings. The bushings shall be fixed to the transformers on side with straight pockets and in the same plane or the top cover . The tests as per latest IS 2099 and IS 7421 shall be conducted on the transformer bushings.(k) OIL CONSERVATOR:The provision of conservator is mandatory with oil gauge, air release plug andbreathing device with a drain plug and a filling hole 32 mm (1¼”) normal size thread with cover. The dehydrating agent shall be silica gel. The moisture absorption shall be indicated by a change in the colour of the silica gel crystals which should be easily visible from a distance. Volume of breather shall be suitable for1Kg of silica gel conforming to IS 3401. The total volume of conservator shall be such as to contain 10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator. 42 (m) The radiators can be tube type or fin type or pressed steel type to achieve the desired cooling to limit the specified temperature rise.(n) Transformer to be painted with poly urethene/powder caoted (color light gray & DA gray) paints over anti corrosive primer & shall be free from runs, sags, wrinkles, patchiness, brush marks or other defects.All primers shall be well marked into the surface, particularly in areas where painting is evident and the first priming coat shall be applied as soon as possible after cleaning. The paint shall be applied by airless spray.(p) One No 100 mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, maxtemp indicator and resetting device(q) Rating plate with terninal markings.(r)Two earthing terminals on tank/tank cover to facilitate fixing of 32 x 6 m GI earth strip.(s) Lifting lugs.(t) Four plane solid cast steel detachable rollers.(u) First fill of fresh transformer oil conforming to IS-335, BS148, D-1473, D-1533-1934IEC Pub296 and tested upto 40 KV dielectric strength. Use of recycled oil is not acceptable. The specific resistance of the oil shall not be less than 2.5X10¹² ohm-cm at 27°C when tested as per IS 6103.(v) Extra bushing for neutral outside the L.T cable box for providing independent earthing for neutral.(w)Provision of 2 Nos danger boards 250 x 200 mm size made out of 1.6 mm thick M.S. plate, vitreous enameled white, with letters. figures of voltage and conventional skull and bones insignal red colour , one at H.T side and other on L.T side.(x)Any other fittings / accessories so as to conform the whole transformer toIS 1180 (Part 1): 2014 (y) The DistributionTransformers to be supplied against this Specification shall be suitable for satisfactory continuous operation under the following climatic conditions as per IS 2026(Part-I):(i) Location:Ahmedabad(ii)Maximum ambient air temperature:50 °C(iii) Minimum ambient air temperature :5°C(iv) Maximum average daily ambient air temperature:42 °C(v)Maximum yearly weighted average ambient temperature : 32 °CThe temperature rise over ambient shall not exceed the limits given below:(i) Top oil temperature rise measured by thermometer : 35 °C(ii) Winding temperature rise measured by resistance method : 40 °C 43 (x)Any other fittings / accessories so as to conform the whole transformer toIS 1180 (Part 1): 2014 (y) The DistributionTransformers to be supplied against this Specification shall be suitable for satisfactory continuous operation under the following climatic conditions as per IS 2026(Part-I):(i) Location:Ahmedabad(ii)Maximum ambient air temperature:50 °C(iii) Minimum ambient air temperature :5°C(iv) Maximum average daily ambient air temperature:42 °C(v)Maximum yearly weighted average ambient temperature : 32 °CThe temperature rise over ambient shall not exceed the limits given below:(i) Top oil temperature rise measured by thermometer : 35 °C(ii) Winding temperature rise measured by resistance method : 40 °C 44 M&L for Transformer platform 250 KVA out door type made of brick masonry size 2000mm x 2000mm x 1400mm, over PCC foundation 1:3:6 type C-2,with brick work sub classB bricks in cement motar 1:4 and plaster work 10mm thick in cement plaster 1:4 incl sand filling and elevated with Angle iron guard rail of 600mm heightwelded with M.S Angle iron 60x60x6mm, MS flat 50x6mm for interlocking arrangements and guard rails wire netting of galvanized steel wire 1.40mm dia with 25x25mm mesh size fixed with tinned tracks of wire staples duly painted with two coat of synthetic enamel aluminium/smoke grey paint over a coat primer complete all as specified and as directed. 45 Supply, install, testing and commissioning of feeder pillar box CPRI approvedoutdoor type of suitable size with modular copartment and openable doors made out of MS angle frame & MS Sheet of 3.15 mm thick with doble door incl locking arrangements with based frame and fixing arrangement duly painting with aluminium bus bar 400 Amps 3 phase 4 wire system with heat shrinkable coloured sleeves comprising of the following with earth terminal incl necessary foundation work and suitable cable glands for incomming and outgoing cables following. 46 (a) Incomer(i) ) MCCB 4 pole adjustable thermal 415 volts 320 Amps 35 KA - 01 Nos(ii) Supply & fix Digital panel meter for Amp, Volt, KWH, power factor and other parameter flush mounting of size 96 x96 mm-01No(iii) Digital volt meter 3 phase 0-500 volts(iv) Indicating lamps LED type, 230 volts for RYB including all necessary arrangments - 01 Set(b)Out going(i) MCCB 4 Pole adjustable thermal 415 volts 200 Amps 35 KA - 02 Nos(ii) MCCB 4 Pole adjustable thermal 415 volts 63Amps 25 KA - 02 Nos 47 Supplying, installation, Connecting electrically & commissioning and testing of Outdoor type free standing type (IP -42) automatic power factor correction system with both auto and manual options type Inlet Var APFC Panel with MD - XL capacitors and MCCB as incomer factory made Non compartmentalised single unit 440 Volts 50 Hz , 3 phase 100 KVAR (Multiple of 5 KVAR) Complete all as specified and as directed including the following : 48 (a) Double Metallized paper with polypropylene film cylinderical, type MD-XL capacitor bank of rated voltage 525 volts with detuned Reactor of de - tuning factor (P) 7% and suitable output of 100 KVAr at 440 Volts confirming to IS-13340, 13341, & IEC - 60831 - 1+2.(b) Capacitor duly contactor with Damping Resistors appropriate rating for capacitor switching confirming to IEC - 60070 & IS 13947. (c) Automatic power factor controller relay micro processor based for switching ON & OFF of capacitors and suitable to display of voltage , current, active power, Reactive power, Apparent power, Display of power factor, THD Voltage, THD current, alarm indication for defective steps, low power factor and excess temperature. The relay has volt free c/o contact, Automatic detection and usage of optimum capacitors.(i) Capable of 4 - Quadrant operation, and any phase offset requirement.(ii) Swithching programms : LIFO, Combi - filter, manual mode.(iii) Build in under and over voltage release with auto reset.(iv) Large Voltage input band of 90 Volt to 550 Volt , 45 - 65 Hz.(v) Current measuring 10 mA - 5A , Suitable for CT x/1A and x/5A.(vi) Commissioning without additional settings and programming.(vii) Three decimal power factor reading. 49 (d) Multifunction meter having digital volt meter and ammeter of range as required and recommended by manufacturer with in built selector switch and CTs of appropriate ratio with percentage load bar graph (Model EM 6459) equivalent.(e) MCB D , 3 Pole, 415 Volts Curve type with rupturing cap 10 kA of appropriate rating for protection of individual capacitor bank conf to IS 8828, IEC 898.(f) Incoming TPN MCCB, 400 Amps, Ics = 100% Icu , 25 KA, 4 Pole. (g) Ventilating fans of required size to dissipiate the heat liberated by capacitor units complete with automatic switching ON and OFF of fans depending the temperature of the panel.(h) Emergency stop push button to disconnect the unit in case of emergency.(j) Indicator LED type for phase indication and capacitor banks ON and OFF indication. (k) All accessories prewired with suitable size copper conductor cable insulated with fibre glass insulation to withstand high temperature, housed in cubical panel (CPRI Approved) made out of 3.15 mm thick MS sheet factory made duly powder coated front and rear door openable with locking arrangement complete with foundation as required or recommended by manufacturer. 50 DEMOLITION AND DISMANTLING WORKSDemolition/dismantling of (Bldg No P-2,P-2/F, P-2H, P-2/B-II, P-2/B-I, NP-225 and P-7) any discripition and in any position excluding E/M fittings & fixtures complete As is where is all as specified and directed. 51 NOTE FOR ITEM No 17.00:- The quoted rate shall deemed to include the following:-(i)The demolition of Bldg shall be carried out upto ground level bearing all safety aspects into consideration including overlap with near by Bldgs and making good the ground.(ii) The quoted rate shall be deemed to include demolition of Bldgs except taking down/dismantling internal fittings and accessories of internal electric supply and internal water supply & all other items of demolition & dismantling of Bldgs specified eleswhere in the tender documents.(iii) Schedule of demolition/dismantling shall be decided by GE in the manner to recieve the amount of recovery for credit from RARs/ Final bill.(iv) Demolition of the buildings shall be carried out after taking down of all internal fittings/fixtures & after necessary approval of GE.(v) The quoted rate shall be deemed to include for removal of debries obtaind to out side MOD land including loading & unloading at destination as directed by Engg-in-Charge.(vi) All safety precautions shall be taken by contractor during demolition/dismantling of buildings as per latest by laws and as specified in SSR Part-I. 52 ARBORICULTURESurface excavation in any type of soil not exceeding 30cm deep and averaging upto 15cm and removing up to a distance n exc 50 metre filling back / spreading with red earth of 15 cm thick mixed with farm yard treating the soil with pesticides (i.e Bavitin and neam cake BHC 10% linsondustThimment and Phorate, super and vermi compost in ratio (1:3) incl turfing/laying of(Bermuda grass (Cynodon dactylon), Buffalo grass (Stenotaphrum secundatum) & Korean lawn grass (Zoysia japonica) ready made of approved quality turfs side by side without undualation/depressions and ramming the surface complete all as directed by Engineer-in-charge.Note:- Grassing shall be carried out to carpenting effect i.e. installation 80% of the ground shall not be visible due to plant cover if the desired effect is not obtained then additional grass will be planted as specified to achieve the effect. 53 Supply and plantation of Neem (Azadirachta indica) tree plant Height of sapling not less than 3 ftas approved by GE including excavation of suitable size pitn.exc 0.25 cum in any type of soil incl removal and filling back to pit with suitable growing media like red earth by treating with farm yead manure in the ratio (3:1) fertilizers and pesticides (i.e Bevation and neem cake BHC 10% linson dust.Thimment or phorate, manures super and vermicompost) and making up the trenh area to proper leveletc complete all as sepcified and directed by Engr-in-Charge. 54 All asper item No 18.01 above but Gulmohar (Delonix regia) 55 All asper item No 18.01 above but Peepal tree (Ficus religiosa) 56 All asper item No 18.01 above but Banyan (Ficus benghalensis) 57 All asper item No 18.01 above but Pink Cassia (Cassia javanica) 58 All asper item No 18.01 above but Christmas tree (Araucaria heterophylla) decorative plantsas directed by Engr-in-Charge 59 All asper item No 18.01 above but Golden Cane Palm (Dypsis lutescens) decorative plantsas directed by Engr-in-Charge 60 All asper item No 18.01 above but Royal Palm (Roystonea regia) decorative plantsas directed by Engr-in-Charge 61 All asper item No 18.01 above but Foxtail Palm (Wodyetia bifurcata) decorative plantsas directed by Engr-in-Charge 62 All asper item No 18.01 above but False Ashoka (Monoon longifolium) decorative plantsas directed by Engr-in-Charge 63 S & F of M.S Tree Guard 1.50 Mtrs high above with MS wiremesh of size 78 x 37 mm and 2 mm dia of wire and MS angle iron 20 x 20 x 3 mm verticals (3 Nos) & MS flats 14 x 3 mm around the tree guard (3 Nos top , middle and bottom) equally spaced and embedded vertical angles in PCC 1: 3:6Type B-I including excavation in post holes and removal of excavated material to a n.exc 5 mtr and applying two coats of synthetic enamel paint including one coat of red oxide primer to tree guard and all as specified and directed. 64 NOTE for Sl Item No 18.00 to 18.10 :-(i) Height of plant shall be measured from top of follage (not from the isolated branch/ leaf, main stem) to 150mm from top of root.(ii) Water will not be supplied by MES for arboriculture. Contractor has to make his own arrangement for watering to plants and grass. (iii) The rates quoted by the contractor deemed to include watering, maintenance of plants / grass till two years after certified date of completion of work.(iv). During two years after completion if any plant / grass is found dead or not of satisfactory growth, plants / grass of approved size and shape shall be provided without any extra cost to the Govt.(v). Supply and application of manure, sweet earth and pesticides, fertilizers etc up to two years after completion are deemed to be included in the quoted unit rate.(vi)In case offailure by the contractor to maintain the plants / grass as above, the same shall be carried out by the department at his Risk and Cost..(vii) The plants shall be brought at site Six months before the date of completion of the work as per Work order. 65 NOTE forSCHEDUL OF CREDITRs (-) 754873.00 amount to be deducted from total quoted amount at time of accptance of tender