Tender For Repair And Renovation Work At Tsv Hostel Rca, Udaipur.- 1 Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 2 Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead : Of area exceeding 3 square meter. 3 (a) Of area 3 square meter and below. 4 (b) Of area exceeding 3 square meter. 5 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 6 Providing & laying Chequered terrazzo tiles of approved make 22mm thick with marble chips of size upto 6mm, in floors, jointed with neat cement slurry mixed wit pigment to match the shade of tiles including rubbing and polishing complete in all respect as per specification, on 28mm thick bed of C.M. 1:4 : Dark shade using ordinary cement. 7 Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) 8 Grading roof for water proofing treatment withwater proffing compoundCement mortar 1:3 (1 cement : 3 coarse sand) 9 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 10 Providing and fixing in position collapsible steel shutters with vertical M.S. Channels 20 x 10 x 2mm and bracket with flat iron diagonals 20 x 5mm. size with top and bottom rail of T-iron 40 x 40 x 6mm. with 40mm dia steel pulleys/ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer. (To be measured and paid as per outer dimension). 11 Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 12 Providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.Welded mesh 25 mmx 25 mm x 2.1 mm 13 Providing and fixing Square bars or other flat welded to window, ventilatiors etc. 14 Labour charges for repair to door / window without using any material such as applying randha (finishing) tightening of bolts & screw etc. 15 Repairofdoor,windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : Panel by Shuttering Ply - 9mm thick (Commercial) 16 Repairofdoor,windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : Aldrop of mild Steel 12 long x12mm dia 17 Cleaning of sewer line of various sizes as per requirement at site of different sizes including 100mm,150mm & 225mm dia ofStoneware pipe as per direction of Engineer-in-Charge. 18 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A:30 mm thick . Commercial Veneer both side 19 Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge. 20 Providing and fixing to existing door frames. 30mm thick factory made solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15 mm x15mm , top & bottom rails. M.S .frame shall have a coat of steel primers of approved make and manufacture M.S. frame covered with 5mm thick heat moulded PVC ‘C channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles; and 5mm thick, 95mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered in 45 degreeon the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2) thick, 20mm wide cross PVC sheet shall be provided as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with 7mm (5mm +2mm) thick x 15mm wide PVC sheet bending on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacture’s specification & drawing.(For W.C.and bathroom door shutter). 21 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. 22 Labourchargesforremovingandrefixingofurinals(alltype&sizes)includingall necessary fittings. 23 Labour Charges for removing WVC pan:Indian/Orissa pan,European W.C. 24 Removing and re-fixing of wash hand basin including all necessary fittings. 25 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: Size 580x440mm. 26 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 580 mm x 450 mm 27 P & F 15 mm. Dia Connection Pipe of approved quality/make : PVC pipe withC.P. Brass nuts upto length, 600mm 28 P & F Grating of approved quality/make: Stainless Steel Sheet size 125mm dia. 29 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 30 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make: 110 mm dia 31 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make : 110 mm dia 32 (a)Bend 87.5 Dg. 33 (b) Single Tee 34 (c )Nahni Trap with Jali 4” 35 (d)Door Bend 87.5 Dg. 36 (e)Single Tee with Door 37 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 38 (a) 20 mm nominal size 39 (b) 25 mm nominal size 40 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Old work (One or more coats ) 41 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on New work. 42 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : One or more coats on old work. 43 CARRIAGE OF MATERIALS Earth, Sand, Lime, Morrum manure or sludge Building Rubbish Stone metal (Grit and ballast etc.) For 5 Km. 44 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathedflexiblecopperearthconductor1.1kVgrade(IS:694)in recessed ISI marked MMS (IS:9537 P.III) virgin materialPVC conduit & its ISI maeked (IS:3419 1988)accessories,round tiles,1.2mm thick Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal/ Surface Moulded virgin material 10AModularswitch,Modular face platewithgridplate,3pin ceilingrose /holder /3way Connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 45 (a) S.P. (up to 3 mtr.) 46 (b) M.P. (up to 6 mtr.) 47 (c ) L.P. (up to 10 mtr.) 48 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FRPVCinsulatedunsheathedflexiblecopperconductor1.1kVgrade and1.5sq.mmnominalsizeFRPVCinsulatedunsheathedflexible copper earth conductor 1.1 kV grade(IS:694) on surfaceISI marked ( IS:14927 P - II ) virgin materialUPVC Trunking & its accessories, Hot Dipped GalvanizedModular box of 1.2 mm thickwith earth terminal/ SurfaceMouldedvirginmaterial UPVCModularBox, modular10A switch, 3/5 pin6 Amodular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR :On board 49 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III)PVCconduitalongwith ISImarked(IS:3419-1988)accessoriesas required in recess including cuttingthewall,coveringconduitand making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR : 25 mm 50 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductorasperPWDspecificationforelectricalWorkswithISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should bemadefrom 99.90%puritycopper,class5strandinginacc.to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization,insulationPVCtypeA/C/D,flameretardantasperIS 10810-53,betteramperageratingasperIS:3961part5, inexisting surfaceorrecessedPVC/MS conduit/casingcapping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required.OEMMusthaveitsowninhouseNABLlabsetupforall testingfacilitiesforwires.Foradditionaltechnicalparametersof product / work refer Annexure A attached with this BSR 51 (a) 2 x 1.5 sq.mm 52 (b) 2 x 2.5 sq. mm + 1x1.5sqmm 53 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of loadand siterequirement)4KVimpulsewithstandvoltage,ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 asperIEC, minimumphaseterminationcapacityof35sq.mm., conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000upto20Aratingand10,000upto63A,5000for80A& above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR : Single pole MCB (With B/C curve tripping Characteristics)6 A to 32 A rating 54 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular boxof1.2mmthickwithearthingterminal/connectoronsurfaceorin recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16amp.socketoutlet(IS:1293)makingconnection,testing,etc.as required.Forspecificationof WiringaccessoriesreferChapter E-07 related item & For additional technical parameters of product / work refer Annexure A attached with this BSR