| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-07-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 31-07-2025 |
| Sl. No. | Item Description |
| 1 | B/R SERVICES / WORKS :- |
| 2 | Demolition of Cement Concrete (Un-reinforced) in Ground Floors and Pavings not exc. 150mm thickness (below or above Ground Level) and Removing Debris, etc. to a Distance exc. 50.00 Metre but not exc. 100.00 Metre, complete all as specified and as directed. |
| 3 | Demolition Cement Concrete (Reinforced) in any Position not otherwise specifically Provided for including Reinforcement cut as required to facilitate Demolition and Removing Debris, etc. to a Distance exc. 50.00 Metre but not exc. 100.00 Metre, complete all as specified and as directed. |
| 4 | Demolition Brick Masonry Work, built in Cement Mortar and in any Position including all Quoins, Arches and Pillars, etc. and Removing Debris, etc. to a Distance exc. 50.00 Metre but not exc. 100.00 Metre, complete all as specified and as directed. |
| 5 | Taking down Chowkats or Frame (without Taking Off Shutter from the Frame) of any description, not exc. 1.50 Square Metre Each, complete all as specified and as directed. |
| 6 | Taking down Chowkats or Frame (without Taking Off Shutter from the Frame) of any description, exc. 1.50 Square Metre but not exc. 4.00 Square Metre Each, complete all as specified and as directed. |
| 7 | Taking down Shutter of any description, not exc. 1.00 Square Metre Each, complete all as specified and as directed. |
| 8 | Dismantling Wrought Iron or Mild Steel Work of any description not otherwise provided for, complete all as specified and as directed. |
| 9 | S & F in repair 6mm thick second class hard wood cover fillets (breading) of standard hard board, 20mm wide and fixing with screws complete all as specified and as directed. |
| 10 | Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing) and Removing Debris, etc. to a Distance exc. 50.00 Metre but not exc. 100.00 Metre, complete all as specified and as directed. |
| 11 | Dismantling Stone Slabs and/or Tiles of any description or thickness in Floors, Aprons, etc. laid, bedded and pointed in Cement Mortar and Removing Debris, etc. to a Distance exc. 50.00 Metre but not exc. 100.00 Metre, complete all as specified and as directed. |
| 12 | Taking down Cement Plaster including Raking out Joints, hacking for Key, scrubbing down with Water and Removing Debris, etc. to a Distance exc. 50.00 Metre but not exc. 100.00 Metre, complete all as specified and as directed. |
| 13 | Taking up or down Steel Tubing 15mm bore (dia) and Fittings/ Connections of any description from any Situations, complete all as specified and as directed. |
| 14 | Taking up or down Steel Tubing 20mm bore (dia) and Fittings/ Connections of any description from any Situations, complete all as specified and as directed. |
| 15 | Taking up or down PVC (SWR) Soil, Waste and Ventilating Pipe upto 110mm bore (Dia) with Fittings of any description from any Situations, complete all as specified and as directed. |
| 16 | M&L Plain Cement Concrete 1:3:6, type C-1 (using 20mm graded stone aggregates) as in Lintels upto 1.50 Metre Clear Span, Cills, Steps; Seismic and Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets and Railings upto 600mm in Height, Copings, Kneelers, Apex Stones, Bed Plates, Water Troughs and the Like including Weathering, Slightly Rounded or Chamfered Angles and Throating, Finishing all Exposed Faces of Concrete including Use and Waste of Formwork as required/ ordered, complete all as specified and as directed. NOTE : Cost of Formwork will deem to be included in the Unit Quoted Rate. |
| 17 | M&L Brick Work in One or More Brick thick Walls with Sub-Class ‘B’ Bricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, Built in Cement Mortar 1:6, complete all as specified and as directed. |
| 18 | M&L Brick Work in Half-brick thick Walls with Sub-Class ‘B’ Bricks (Old Size Bricks), Straight or Curved on Plan to any Radius, Built in Cement Mortar 1:4, complete all as specified and as directed. |
| 19 | M&L Cutting Holes in Brick Walling, not exc Half-brick thick, built in Cement Mortar for inserting of Holdfasts, Lugs, etc. and Making Good to Dismantled Portion with Cement Concrete 1:2:4 (20mm graded stone aggregates) or Cement Mortar 1:3 (as required) and Adjoining Surfaces in Cement Mortar 1:4, complete all as specified and as directed. |
| 20 | M&L Cutting Holes in Brick Walling, exc. Half-brick and not exc. One Brick thick, built in Cement Mortar for inserting of Holdfasts, Lugs, etc. and Making Good to Dismantled portion with Cement Concrete 1:2:4 (20mm graded stone aggregates) or Cement Mortar 1:3 (as required) and Adjoining Surfaces in Cement Mortar 1:4, complete all as specified and as directed. |
| 21 | M&L Cutting Chases, Pinning in, Making Good to Facings where required and Pointing in Cement Mortar 1:3 to Ends or Edges of Cills, Shelves, Lintels, etc., and Cutting Chases for Concealed Water Tubing and Making Good, Cutting Girth not exc. 10 Cm and not exc. 5.0 Cm in Depth, complete all as specified and as directed. |
| 22 | M&L Second Class Hardwood (well seasoned) Plain, Solid, Straight, Chowkats and Frame, Wrought, Framed rebated on the Solid, Rounded or Chamfered, put together with Glue pinned at Joints, complete all as specified and as directed. |
| 23 | M&L Factory Made Plain Framed, Panelled Shutter 35mm thick (Two Panels) with Lock Rail and Panel of 9.0mm thick BWP, Commercial Ply or 12mm thick Veneered Particle Board with Commercial Veneering on both Faces, having Sizes of Rails and Stiles as per IS:1003 (Part I) of Second Class Hardwood (Kiln Seasoned & Chemically Pressure Treated) and fitted to Chowkats, complete all as specified and as directed. |
| 24 | M&L Second Class Hardwood (well seasoned) Glazed and Skeleton Shutter 35mm thick, Open Rebated and Prepared to Receive Gauge, Glass, etc., Divided into Squares, with Plain, Chamfered or Rounded, Mitred and Rebated Sash Bars, any Numbers, Sizes of Members of Shutter as specified in SSR Part-I, Section 8, Clause 8.24(a) and fitted to Chowkats, complete all as specified and as directed. |
| 25 | S&F Solid PVC Door Frame of size 50x47mm made out of 5.0mm Plain Colour PVC Sheet reinforced with Mild Steel Square Tube and fixing in Opening, complete all as specified and as directed. |
| 26 | M&L Factory Made Solid Panel PVC Door Shutter 30mm thick (Style) Plain Colour (Ivory shade) consisting of Frame made out of Mild Steel Tubes for Top and Bottom Rails, Mild Steel Frame shall be covered with heatmoulded wood grain PVC ‘C’ Channel having a PVC Sheet Strip of 20mm width stuck inside with Solvent Cement for Stiles and Wood Grain PVC Sheets for Top Rail, Lock Rail & Bottom Rail on either Side and as gap insert for Top Rail & Bottom Rail, Panelling of Wood grain PVC Sheet to be fitted in the Mild Steel Frame welded/sealed to the Stiles and Rails with suitable 5mm thick x 15mm wide PVC Sheet Beading used inside Stiles and Rails and decorative PVC Beading of 10mm x 10mm (90°) and jointed together with Solvent Cement and fixing in the Frame and hanging/ fixing with and including Stainless Steel Hinges, complete all as specified and as directed. NOTE : Butt Hinges will be Measured and Paid under Item No. 1.031. |
| 27 | M&L Powder Coated (Minimum thickness of Powder Coating 50 Micron) Aluminium Ventilator Frame having Frame of Section 100x44mm of thickness 1.6mm Shutters of Section 32x15mm (with and including Half Portion fixed Glazed Shutter and Rest Half Portion Louvered with Glazed Shutter) including Stainless Steel Wire Mesh, Rubber Gasket for Securing the Glass 5.5mm thick Figured Glass, Aluminium Grill and necessary Aluminium Mongery and Handles including necessary Locking Arrangement, complete all as specified and as directed. |
| 28 | M&L Powder Coated (Minimum thickness of Powder Coating 50 Micron) Aluminum Sliding Windows 2-Tracks with 2 Sliding Shutters with Extrusions Aluminum of following Sections including Jointing Cleats, Glazing Clips, Rubber Packaging, Snap Beading and other necessary Aluminium Builders Hardware as required, complete all as specified and as directed :- A. FRAME :-(i) Top and Side Member for 2 Track Frame of Size 61.85x31.75x1.5mm (Weighing 0.784 KG/RM), Model No. 20829 of Make : Jindal or equivalent.(ii)Bottom Rail of Frame for Sliding of Size 61.85x31.75x1.5mm (Weighing 0.909KG/RM), Model No. 20830 of Make : Jindal or equivalent.B. SHUTTER :-(i)Top and Bottom Rail of Sliding Shutter of Size 40x18x1.5mm (Weighing 0.547 KG/RM), Model No. 20736 of Make : Jindal or equivalent.(ii) Side of Sliding Shutter with Handle and Self Locking Arrangement, Section of Size 40x18x1.5mm (Weighing 0.547 KG/RM), Model No. 20738 of Make : Jindal or equivalent.(C) Sliding Shutter to be provided with 5.0mm thick Sheet Glass.(D) Aluminum Diamond Grill 6.5mm thick with Mat Finished fixing on Wall/ Wooden Chowkat/ Aluminium Frame with suitable Size of Aluminum \"U\" Channel and Steel Chromium Plated, Screw with Rawel Plug with following Details :-(i) Aperture Size of Aluminum Grill 67x84mm.(ii)Cord Dimension 7.0x5.8mm.(iii) Plate thickness 3.0mm.(E) Stainless Steel Wire Cloth, 0.36mm Nominal Dia of Wire and Average Width of Aperture 1.40mm and fixed with Stainless Steel Wire Staples/ Clip/ Aluminium Flat |
| 29 | S&F Aluminium anodised Barrel Tower Bolt, 150mm long, Extruded Section, complete all as specified and as directed. |
| 30 | S&F Aluminium Alloy Anodized Sliding Door Bolt 300mm Long with Hasp Staple (Bolt type) and Fixing Clips of Sheet, Cast or Extruded Section and fixing Bolts and Sliding Bolts of Extruded Section and Fixed, complete all as specified and as directed. |
| 31 | S&F 75mm Size (as approved) Stainless Steel Butt Hinge and Fixing to PVC Door Shutter, complete all as specified and as directed. |
| 32 | S&F100mm size Mild Steel Butt Hinge, Medium Weight, Cold Rolled and fixed Shutter, complete all as specified and as directed. |
| 33 | S&F Continuous (Piano) Hinges, Width of Flaps (when open) in 30mm, Mild Steel, Bright Finish or Electro-galvanised and Fixed-in-repairs, complete all as specified and as directed. |
| 34 | S&F150mm long Aluminium Handle, Cast type, anodised, Extruded and fixed, complete all as specified and as directed. |
| 35 | S&F Mild Steel Curtain Rod/ Harrison Rail 20mm Dia, Chromium Plated with Brackets, Stops, Rollers, fixed on Walls and Fixed-in-repairs, complete all as specified and as directed.NOTE :-(a)Brackets, Stops, Rollers, etc. as required will be provided for Each Length of Curtain Rod/ Harrison Rail and Cost for the same will deem to be included in the Quoted Unit Rate.(b)Only Length of Curtain Rod/ Harrison Rail will be Measured for Payment. |
| 36 | M&L Stainless Steel Wire Cloth 0.36mm nominal dia of Wire and average width of aperture 1.40mm and fixed with Stainless Steel Wire Staples, complete all as specified and as directed. |
| 37 | S&F 4.0mm thick Sheet Glass, Ordinary, Glazing in Metal or Wooden Frames and glazed with Oil Putty/ Wooden Beads, not exc. 0.50 Sqm in Each Pane, complete all as specified and as directed. |
| 38 | M&L TMT Bars 8.0mm dia in Stirrups, Spacers and Binders, Cut to Length, Bent to Shape required, including Cranking, Bending Spirally for Hooping for Columns, Hooking Ends and Binding with and including Mild Steel Wire (annealed) not less than 0.9mm dia, complete all as specified and as directed. |
| 39 | M&L Mild Steel Bands, Straps, Supports or Stays for Rain Water, Ventilating Pipes including Bolts (if required), Heavy Hooks (Stay) for Large Gates; Hook and Pintle Hinges, Large Hasps and Staples; Chains; Hand Made Sliding Bolts; Clamps; Holdfasts (Flat Iron 25x4.0mm); Wall Ties; Hooks for Hanging Fans; Plain Angle Cleats for securing Purlins to Wood Trusses or Rafters; Knee Piece inserts; 2-way and 3-way Straps, Plate Washers and Similar Small Articles, conform to Fe-290 Gde-E-165, complete all as specified and as directed. |
| 40 | Dismantling Cement Concrete (Un-reinforced) in any Position (Sunken Floor) not other-wise specifically Provided for, Cleaning Sunken Portion including Vertical Wall Surfaces and Removing Debris, etc. to a Distance exc. 50.00 Metre but not exc. 100.00 Metre, complete all as specified and as directed. |
| 41 | M&L Cement Concrete 1:5:10 (40mm graded stone aggregates) Filling in Sunken Portion of Floors, etc., complete all as specified and as directed. |
| 42 | M&L Applying Sunken Floor Treatment with the following Specifications :-(a) The Sunken Portion shall be Tested for Leakage/ Seepage/ Dampness by Pounding with Water for 72 Hours. In case any detect is Noticed the Portion shall be Grouted with Cement Slurry Mixed with Suitable Chemical & Tested again. The Process of Grouting and Testing shall be Repeated till Leakage/ Seepage / Dampness is eliminated.(b) Top of RCC Slab in Sunken Portion including Peripheral Beams shall be Plastered with 15mm thick in Cement Mortar 1:3, Mixing with and including Approved Water Proofing Compound @ 3% by Weight of Cement, Finished Plastered Surfaces Even and Smooth Without Using Extra Cement and Curved adequately and allowed to Dry.(c) Applying Two Coats of Epoxy Resin/ Polymer Modified Cementitious Coating like Brush bond of Fosroc or equivalent (as approved by GE) both on Floor and Walls/ Beams as per Manufacturer Instructions.(e) Slabs to be given 1:20 Slope Outward with 25mm GI Pipe as Spout with 300mm Projection Beyond Outer Surface of Wall.(f) After the Surface is Passed by the Engineer-in-Charge for Water Tightness by Flooding for 72 Hours the same shall be filled with Lean Concrete up to the required Depth.NOTE : Cost of WPC mentioned at (b) here-in-above will deem to be included in the Quoted Unit Rate. However, Filling of Cement Concrete to Sunken Portion will be Measured and Paid separately under Sl No. 1.040 here-in-after. |
| 43 | S&F Plywood 12mm thick, Grade BWR, Type BB, fixed with Screws to Timber Frame Work, complete all as specified and as directed. |
| 44 | S&F Pre-laminated Particle Board 18/19mm thick, Interior Grade, Pre-laminated One Side with Decorative Choice Lamination and Other Side Balancing White Lamination, fixed with Screws to Timber Frame Work, complete all as specified and as directed. |
| 45 | M&L 75mm thick Plain Cement Concrete 1:2:4, type B-2 (Using 40mm graded stone aggregates)as in Sub-base to Floor, etc., complete all as specified and as directed. |
| 46 | M&L Joint Free Non-Skid Ceramic Coloured Tiles 7.0mm to 8.0mm thick (Rectangular or Square), Area of Each Tile exc. 0.06 Sqm but not exc. 0.11 Sqm (1st quality) in Floors, Set and Jointed in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, laid over and including Screed or Screed Bed 15mm thick in Cement Mortar 1:6, complete all as specified and as directed.NOTE : Cost of Screed Bed will deem to be included in the Quoted Unit Rate. |
| 47 | M&L Joint Free Non-Skid Ceramic Coloured Tiles 7.0mm to 8.0mm thick (Rectangular or Square), Area of Each Tile exc. 0.18 Sqm but not exc. 0.36 Sqm (1st quality) in Floors, Set and Jointed in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, laid over and including Screed or Screed Bed 15mm thick in Cement Mortar 1:6, complete all as specified and as directed.NOTE : Cost of Screed Bed will deem to be included in the Quoted Unit Rate. |
| 48 | M&L Joint Free Non-Skid Ceramic Coloured Tiles 7.0mm to 8.0mm thick (Rectangular or Square), Area of Each Tile exc. 0.18 Sqm but not exc. 0.36 Sqm (1st quality) in Vertical Surfaces i.e. Dado, Skirting, etc., Set in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, fixing over and including Screed or Screed Bed 10mm thick in Cement Mortar 1:4, complete all as specified and as directed.NOTE : Cost of Screed Bed will deem to be included in the Quoted Unit Rate. |
| 49 | M&L Glazed Ceramic Coloured/ Printed Tiles 450x300x7.0mm thick in Vertical Surfaces i.e. Dado, Skirting, etc., Set in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, fixing over and including Screed or Screed Bed 10mm thick in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Screed Bed will deem to be included in the Quoted Unit Rate. |
| 50 | M&L Green Marble Work 18mm to 20mm thick (Table Rubbed and Polished) in Steps, Jambs, Pillars, Window Cills, Cooking Platforms and like in Cement Mortar 1:4 including Pointing in White Cement 1:2 Using Marble Dust with Admixture of Pigment to Match the Shade of Marble including Grinding and Polishing, Fixing over and including 20mm thick Cement Screed Bedin Cement Mortar 1:6, complete all as specified and as directed.NOTE : Cost of Screed Bed will deem to be included in the Quoted Unit Rate. |
| 51 | M&L Machine Cut Kota Stone Slab Flooring 16mm to 18mm thick, Laid over and including 20mm thick Cement Screed Bedin Cement Mortar 1:4 and Jointed with Grey Cement Slurry mixed with Pigment to match the Shade of the Slab including Rubbing/ Grinding and Polishing, complete all as specified and as directed.NOTE : Cost of Screed Bed will deemed to include in the Quoted Unit Rate. |
| 52 | M&L 75mm thick Plain Cement Concrete 1:3:6, Type C-2 (using 40mm graded stone aggregates) as in Plinth Protection, etc., laid in alternate Panels, finished Concrete Surfaces Even and Smooth without Using Extra Cement, complete all as specified and as directed. |
| 53 | M&L Rendering 5.0mm thick in Cement Mortar 1:3 on Concrete Surfaces such as Soffits of Slabs, Ceilings, etc. in Patches not exc. 1.00 Sqm Each, finished Plastered Surfaces Fair and Even, complete all as specified and as directed. |
| 54 | M&L 10mm thick renderingin Cement Mortar 1:6 on Brick or Concrete Surfaces, finished Plastered Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed. |
| 55 | M&L 15mm thick Rendering on Bricks or Concrete Works consisting in 2 layers, Back/ Under layer of 10mm thick in Cement Mortar 1:6 and Float/ Top layer 5.0mm thick in Cement Mortar 1:4 including Mixing WPC to Float/ Top finished Plastered Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed.NOTE : Water Proofing Compound (WPC) will be Measured and Paid separately under relevant item here-in-below. |
| 56 | Supply only Water Proofing Compound (as approved), conforming to IS:2645-2003, complete all as specified and as directed. |
| 57 | M&L applying Three Coats of White Wash after Preparation of New Plastered Ceiling Surface complete all as specified and as directed. |
| 58 | M&L applying One Coat of White Wash after Preparing Old Plastered Ceiling Surfaces complete all as specified and as directed. |
| 59 | M&L Preparing New Plastered Surfaces on Walls, Applying 1.5mm thick Wall Care Putty including Cutting/ Rubbing down to obtain an Even and Smooth Surface, Applying Two Coats of Distemper Oil Emulsion (as approved) Over a Coat of Alkali Resistant Priming Paint, complete all as specified and as directed. |
| 60 | M&L Applying Two Coats of Distemper Oil Emulsion (as approved) including Complete Removal of Existing Surface Treatment on Walls, Applying 1.5mm thick Wall Care Putty including Cutting/ Rubbing down to obtain an Even and Smooth Surface complete all as specified and as directed. |
| 61 | M&L Preparing Newly Plastered Surfaces of Walls and Applying Two Coats of Acrylic based Weather Coat Exterior grade Emulsion Paint (any Tinted) in Camouflage Pattern Over a Coat of suitable Primer (as specified by Manufacturer of Paint) including Cleaning Drops from Joinery, Glasses, Electrical Fittings and Washing Floors, etc., complete all as specified and as directed. |
| 62 | M&L Preparing Old Plastered Surfaces of Walls and Applying One Coat of 100% Acrylic Exterior Emulsion Paint (any Tinted) in Camouflage Pattern including Cleaning Drops from Joinery, Glasses, Electrical Fittings and Washing Floors, etc., complete all as specified and as directed. |
| 63 | M&Lapplying Two Coats of Synthetic Enamel Paint (1st grade quality Paint of as approved Tint) over a Coat of Pink Primer after preparing New Wooden Surfaces of any description, over 10 Cm in Width or Girth complete all as specified and as directed. |
| 64 | M&L applying One Coat of Synthetic Enamel Paint (1st grade quality Paint of as approved Tint) after Preparing Old Painted Wooden Surfaces of any description Over 10 Cm in Width or Girthcomplete all as specified and as directed. |
| 65 | M&L applying One Coat of Synthetic Enamel Paint (1stgrade qualityPaint of approved Tint) after Preparing Old Painted Wooden Surfaces of any description, not exc. 10 Cm in Width or Girth when unconnected with other Painting or when Painted in different Tint complete all as specified and as directed. |
| 66 | M&L applying Two Coats of Synthetic Enamel Paint (1st grade quality Paint of approved Tint) over a Coat of Red Oxide Zinc Chrome Primer after Preparing new Steel and Iron Surfaces of any descriptions, exc. 10 Cm in Width or Girth complete all as specified and as directed. |
| 67 | M&L applying One Coat of Synthetic Enamel Paint (1st grade quality Paint of as approved Tint) after Preparing Old Painted Steel and Iron Surfaces of any description, Over 10 Cm Width or Girth complete all as specified and as directed. |
| 68 | M&L applying One Coat of Synthetic Enamel Paint (1st grade quality Paintof approved Tint), Preparing Old Painted Steel and Iron Surfaces of any descriptions, not exc. 10 Cm in Width or Girth when unconnected with other Painting or when Painted in different Tint and complete all as specified and as directed. |
| 69 | M&L Preparing Surfaces of Wood and Wood Based Materials, New or Old of any description and girth, not otherwise described and Treated with Two Coats of Creosoting Oil, complete all as specified and as directed. |
| 70 | M&L Preparing Surfaces of Wood and Wood Based Materials of any description not otherwise described such as Ends of Posts, Backs of Chowkats, etc. and Treated with Tar or Coal Tar Black Paint, Area Tarred exc. 0.10 Sqm but not exc. 0.50 Sqm Each, complete all as specified and as directed. |
| 71 | M&L Preparing Steel and Iron Surfaces of any descriptions not otherwise described such as Holdfast or Similar Small Items and Treated with Tar or Coal Tar Black Paint, Area Tarred not exc. 0.10 Sqm Each, complete all as specified and as directed. |
| 72 | S&F CPVC Pipe 20mm Outer dia, SDR 11 & Plain CPVC SDR 11 Fittings on Walls/ Ceiling or Laying in Floors, complete all as specified and as directed. |
| 73 | S&F Brass Elbow suitable for CPVC Pipe 20mm Outer dia, SDR 11, complete all as specified and as directed. |
| 74 | S&F Brass Tee suitable for CPVC Pipe 20mm Outer dia, SDR 11, complete all as specified and as directed. |
| 75 | S&F Male Brass Threaded Adaptor (MTA/ MBTA) suitable for CPVC Pipe 20mm Outer dia, SDR 11, complete all as specified and as directed. |
| 76 | S&F Female Brass Threaded Adaptor (FTA/ FBTA) suitable for CPVC Pipe 20mm Outer dia, SDR 11, complete all as specified and as directed. |
| 77 | S&F Union suitable for CPVC Pipe 20mm Outer dia, SDR 11, complete all as specified and as directed. |
| 78 | S&F 20mm bore (dia) Galvanised Steel Tubing\"medium grade\", conforming to IS-1239 with all Fittings, fixed to Walls, Ceiling or laid in Floors, complete all as specified and as directed. |
| 79 | S&F Bib Tap 15mm bore (dia) Cast Copper alloy, Chromium Plated, Fancy type with Crutch or Butter-fly Handle, screwed down, screwed for Iron Pipe or for Brass Ferrule and Fixed-in-repairs, complete all as specified and as directed. |
| 80 | S&F Pillar Tap 15mm bore (dia), Cast Copper alloy Chromium Plated, Fancy type, with Capstan Heads, screwed down High Pressure, with or without lettered \"Hot\" or \"Cold\" with Long Screwed Shanks and Fly-nuts, screwed for Iron Pipe and Fixed-in-repairs, complete all as specified and as directed. |
| 81 | S&F Stop Valve 15mm bore (dia), Cast Copper alloy, Chromium Plated, Fancy type, Screwed down, High Pressure, with Crutch or Butter-fly handle, screwed both Ends for Iron Pipe or for Unions and Fixed-in-repairs, complete all as specified and as directed. |
| 82 | S&F Stop Valve 15mm bore (dia), Cast Copper alloy, Chromium Plated, Fancy type with Long Shank and Cup (Concealed type), screwed down, high pressure, with Crutch or Butter-fly handle, screwed both Ends for Iron Pipe or for Unions and Fixed-in-repairs, complete all as specified and as directed. |
| 83 | S&F 20mm bore (dia) Gun Metal Globe/Gate Valve with Iron Wheel Head, Screwed both Ends for Iron Pipe and Fixed-in-repairs, complete all as specified and as directed. |
| 84 | S&F PTMT Ball Valve 20mm bore (dia), having Weight not less than 210 Grams, High Pressure with Epoxy coated Aluminium Rod and High Density Plastic Ball, screwed for Iron Pipe and Fixed-in-repairs, complete all as specified and as directed. |
| 85 | M&L Vitreous China White Squatting Pan of Size 580x440mm, Orissa Pattern with Integral Foot Rests, ‘P’ or ‘S’ Trap, providing Joints between Flush Pipe and Socket of WC Pan, Cones, India Rubber (nozzles of WC Pan) including Cement Concrete 1:5:10 (40mm graded stone aggregates) in Bedding and Making Good to Floor/ Disturbed Surfaces and Fixed-in-repairs, complete all as specified and as directed. |
| 86 | S&F PVC Flushing Cistern 10 Litre capacity White, Low Level, Valveless, Syphonic Action type, ISI Marked with Inlet, Ball Valve, Float and Handle, a Pair of Cast Iron Brackets Erecting Stand duly Painted, including PVC Flush Pipe 32mm or 40mm bore (dia) of Low or High density with PVC Long Bend, Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 and Fixed-in-repairs, complete all as specified and as directed. |
| 87 | S&F Vitreous China White Wash Hand Basin 550x400mm, Flat Back or Angle Back type with Brass Chromium plated Waste Fitting 32mm bore (dia) and PVC Waste Pipe 32mm or 40mm bore (dia) of Low or High density, a Pair of Cast Iron Brackets or Erecting Stand duly Painted, Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 but excluding Taps, Chain, Plug & Porcelain Stopper and Fixed-in-repairs, complete all as specified and as directed. |
| 88 | S&F Kitchen or Laboratory, made of Stainless Steel l.0mm thick, Overall Size 495x420mm having Bowl Size 410x330x160mm with Plugs, Washers, Wastes and PVC Waste Pipe 32mm or 40mm bore (dia) of Low or High density, including Bedding in Cement Mortar on to Dwarf Wall or including Fixing Cantilever Brackets and Connecting Union to Pipe and Fixed-in-repairs, complete all as specified and as directed. |
| 89 | S&F PVC Connection Pipe 15mm in size and 450mm in Length with PTMT Nuts and Fixed-in-repairs, complete all as specified and as directed. |
| 90 | S&F Looking Mirror size 600x450mm, 5.5mm thick Selected quality Glass, Bevelled edge, mounted on 4.0mm thick PVC Sheet with PVC/PTMT Frame, fixed to Wooden Plug with Brass Chromium plated Screws and Fixed-in-repairs, complete all as specified and as directed. |
| 91 | S&F Chromium Plated Shower Rose 125mm Size with Shower Arm, Swivel Joint including fixing to Steel/ CPVC Pipe and Fixed-in-repairs, complete all as specified and as directed. |
| 92 | S&F Tubular Towel Rail 20mm dia, Brass Chromium Plated, D-type, 600mm Long between Flanges with Bracket (One Pair) and Fixed-in-repairs, complete all as specified and as directed. |
| 93 | S&F Stainless Steel Soap Dish, not less than 150mm in Size (as approved), fixing to Walls with and including Chromium plated Brass Screws and Wooden/ Plastic Cleats and Fixing-in-repairs, complete all as specified and as directed. |
| 94 | S&F in repair 75mm bore (dia) PVC (SWR) Floor Trap with Chromium Plated Grating, Plain including Jointing to Waste Pipe with Solvent Cement and Fixed-in-repairs, complete all as specified and as directed. |
| 95 | S&Fin repair 100mm dia (Minimum weight 25 Grams) PTMT Grating Doom, complete all as specified and as directed. |
| 96 | S&Fin repair 100mm bore (dia) PVC (SWR) Pipe, Single Socketed, in any length with Rubber Ring Joints, Fixing to Walls or Laid on Floors with Clamps, complete all as specified and as directed. |
| 97 | S&F in repar 75mm bore (dia) PVC (SWR) Bends (any Radius) and Jointing with Solvent Cement, complete all as specified and as directed. |
| 98 | S&F in repar 75mm bore (dia) PVC (SWR) Junction, Single (Single T), Equal or Unequal with Access Door and Jointing with Solvent Cement, complete all as specified and as directed. |
| 99 | S&Fin repar 75mm bore (dia) PVC (SWR) Pipe, Single Socketed, in any length with Rubber Ring Joints, Fixing to Walls or Laid on Floors with Clamps, complete all as specified and as directed. |
| 100 | S&Fin repar 110mm bore (dia)PVC (SWR) Bends (any Radius) and Jointing with Solvent Cement, complete all as specified and as directed. |
| 101 | S&Fin repar 110mm bore (dia) PVC (SWR) Junction, Single (Single T), Equal or Unequal with Access Door and Jointing with Solvent Cement, complete all as specified and as directed. |
| 102 | E/M SERVICES/ WORKS :- |
| 103 | M&L Taking down carefully Unserviceable Copper/Aluminium Point Wiring (Light, Fan, Socket or Power) complete from in any Situations including Fixtures and Fittings such as Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fittings of any description, etc, Making Good Disturbed Surfaces of Walls/ Ceilings, etc. in Cement Mortar 1:3 and Applying Surface Treatment (White/Colour Washing/ Distempering/ Painting) wherever required to match the Existing Finishes, complete all as specified and as directed. |
| 104 | M&L Taking down/out Unserviceable Sub-main Wiring from Batten/ Conduit/ PVC Casing Capping of any description, Making Good disturbed Portion/ Surfaces of Walls/ Floor/ Ceiling, etc. by using Cement Mortar 1:3 and Applying Surface Treatment (White/ Colour Washing/ Distempering/ Painting) wherever required to match the Existing Finishes, complete all as specified and as directed. |
| 105 | Taking down Ceiling Fan, Exhaust Fan of any description from any Situation, Sealing Cable End, Dismantling Blades and Keep in Safe Custody for Re-hanging/ Re-fixing, complete all as specified and as directed. |
| 106 | Taking down MCB DB/ Main Switch with MCB of any description including Making Good Disturbed Surfaces of Walls/ Ceilings, etc. with Cement Mortar 1:3 and Applying Surface Treatment (White/Colour Washing/ Distempering/ Painting) wherever required to match the Existing Finishes, complete all as specified and as directed |
| 107 | M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green colour) as Earth Continuity Wire, drawn in Concealed PVC Conduit, heavy duty (HMS grade) of suitable Dia/ Size alongwith all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddle, etc. complete with GI Terminal Box not less than 1.5mm thick, fixing Flush to Wall Surfaces, covered with 3.0mm thick Plastic laminated Sheet Cover and/or Modular Plates of suitable Size for mounting Switches, Sockets, etc., Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/ FAN/ BELL POINT controlled by One 1-way Switch 6 Amp, complete all as specified and as directed. NOTE : Cost of PVC Conduit with all Fitting/ Fixtures, etc. as required at Site of Work will deem to be included in the Quoted Unit Rate.However, Cutting into Chases to Walls required for concealing PVC Conduit and Making Good to damaged Surfaces will deem to be included in the Quoted Unit Rate. |
| 108 | M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green colour) as Earth Continuity Wire, drawn in Concealed PVC Conduit, heavy duty (HMS grade) of suitable Dia/ Size alongwith all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddle, etc. complete with GI Terminal Box not less than 1.5mm thick, fixing Flush to Wall Surfaces, covered with 3.0mm thick Plastic laminated Sheet Cover and/or Modular Plates of suitable Size for mounting Switches, Sockets, Fan Regulators, etc., Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT POINT controlled by One 2-way Switch 6 Amp, complete all as specified and as directed.NOTE : Cost of PVC Conduit with all Fitting/ Fixtures, etc. as required at Site of Work will deem to be included in the Quoted Unit Rate.However, Cutting into Chases to Walls required for concealing PVC Conduit and Making Good to damaged Surfaces will deem to be included in the Quoted Unit Rat. |
| 109 | M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt FRLSH PVC Insulated, Unsheathed, Multi-stranded, Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated Unsheathed FRLSH Multi-stranded, Single Core Copper Conductor Cable (Green colour) as Earth Continuity Wire, drawn in Concealed PVC Conduit, heavy duty (HMS grade) of suitable Dia/ Size alongwith all Fitting/Fixtures as Tee, Bend, Elbow, Socket, Saddle, etc., Connected to Common Earth dolly for ONE 6 AMP SOCKET POINT controlled by One 1-way Switch 6 Amp on SAME BOARD, Controlled by 1-way Switch, complete all as specified and as directed.NOTE : Cost of PVC Conduit with all Fitting/ Fixtures, etc. as required at Site of Work will deem to be included in the Quoted Unit Rate.However, Cutting into Chases to Walls required for concealing PVC Conduit and Making Good to damaged Surfaces will deem to be included in the Quoted Unit Rate. |
| 110 | M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green colour) as Earth Continuity Wire, drawn in Concealed PVC Conduit, heavy duty (HMS grade) of suitable Dia/ Size alongwith all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddle, etc. complete with GI Terminal Box not less than 1.5mm thick, fixing Flush to Wall Surfaces, covered with 3.0mm thick Plastic laminated Sheet Cover and/or Modular Plates of suitable Size for mounting Switches, Sockets, etc., Earth Continuity Wire connected to Common Earth dolly for ONE 6 AMP, 3/5 PIN SWITCH SOCKET COMBINATION POINT on INDEPENDENT BOARD, complete all as specified and as directed.NOTE : Cost of PVC Conduit with all Fitting/ Fixtures, etc. as required at Site of Work will deem to be included in the Quoted Unit Rate.However, Cutting into Chases to Walls required for concealing PVC Conduit and Making Good to damaged Surfaces will deem to be included in the Quoted Unit Rate. |
| 111 | M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green colour) as Earth Continuity Wire, drawn in Concealed PVC Conduit, heavy duty (HMS grade) of suitable Dia/ Size alongwith all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddle, etc. complete with GI Terminal Box not less than 1.5mm thick, fixing Flush to Wall Surfaces, covered with 3.0mm thick Plastic laminated Sheet Cover and/or Modular Plates of suitable Size for mounting Switches, Sockets, etc., Earth Continuity Wire connected to Common Earth dolly for ONE 16 AMP, 3/5 PIN SWITCH SOCKET COMBINATION POINT on INDEPENDENT BOARD, complete all as specified and as directed.NOTE : Cost of PVC Conduit with all Fitting/ Fixtures, etc. as required at Site of Work will deem to be included in the Quoted Unit Rate.However, Cutting into Chases to Walls required for concealing PVC Conduit and Making Good to damaged Surfaces will deem to be included in the Quoted Unit Rate. |
| 112 | M&L Point Wiring with 4.0 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH multi-stranded single core Copper Conductor Cable with 4.0 Sqmm (nominal area) 1100 Volt grade PVC insulated unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green colour) as Earth Continuity Wire, drawn in Concealed PVC Conduit, heavy duty (HMS grade) of suitable Dia/ Size alongwith all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddle, etc. complete with GI Terminal Box not less than 1.5mm thick, fixing Flush to Wall Surfaces, covered with 3.0mm thick Plastic laminated Sheet Cover and/or Modular Plates of suitable Size for mounting Switches, Sockets, etc., Earth Continuity Wire connected to Common Earth dolly for Metal Clad Socket for ONE AC/ GEYSER POINT on INDEPENDENT BOARD, complete all as specified and as directed. NOTE : Cost of PVC Conduit with all Fitting/ Fixtures, etc. as required at Site of Work will deem to be included in the Quoted Unit Rate.However, Cutting into Chases to Walls required for concealing PVC Conduit and Making Good to damaged Surfaces will deem to be included in the Quoted Unit Rate. |
| 113 | M&L Sub-main Wiring with 2-Runs of 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Conductor drawn in Concealed PVC Conduit, heavy duty (HMS grade) of suitable Dia/ Size alongwith all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddle, etc. and Making Good Disturbed Surfaces of Walls/ Roofs/ Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed. NOTE :-(a)Cost of 3-Runs of Cable & 1-Run of PVC Conduit will deem to be included in the Quoted Unit Rate and the same also Measured as ONE UNIT. (b)Sub-main Wiring will be measured PVC Conduit only. Wire required for looping, etc. as ordered will deem to be included in the Quoted Unit Rate. |
| 114 | M&L Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 6.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Conductor drawn in Concealed PVC Conduit, heavy duty (HMS grade) of suitable Dia/ Size alongwith all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddle, etc. and Making Good Disturbed Surfaces of Walls/ Roofs/ Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed. NOTE :-(a)Cost of 3-Runs of Cable & 1-Run of PVC Conduit will deem to be included in the Quoted Unit Rate and the same also Measured as ONE UNIT. (b)Sub-main Wiring will be measured PVC Conduit only. Wire required for looping, etc. as ordered will deem to be included in the Quoted Unit Rate. |
| 115 | S&F Switch Piano 6 Amp, Single Pole, 1-way, Flush type, 230 Volt and Electrically Connecting up, complete all as specified and as directed. |
| 116 | S&F Switch Piano 6 Amp, Single Pole, 2-way, Flush type, 230 Volt and Electrically Connecting up, complete all as specified and as directed. |
| 117 | S&F Bell Push 6 Amp, Flush type, 230 Volt and Electrically Connecting up, complete all as specified and as directed. |
| 118 | S&F Socket Out-let 6 Amp, 3 Pin, Flush type, 230 Volt and Electrically Connecting up, complete all as specified and as directed. |
| 119 | S&F Switch Socket Combination, 6 Amp, 3 Pin, 2-in-1, Flush type, 230 Volt and Electrically Connecting up, complete all as specified and as directed. |
| 120 | S&F Switch Socket Combination, 6/16 Amp, 3 Pin, 2-in-1, Flush type, 230 Volt and Electrically Connecting up, complete all as specified and as directed. |
| 121 | S&F Lamp Holder, PVC/Polycarbonate type with back plate straight or angular for 230 Volt and Electrically Connecting up, complete all as specified and as directed. |
| 122 | S&F Ceiling Rose Surface type, Bakelite, 3 Terminal suitable for 230 Volt and Electrically Connecting up, complete all as specified and as directed. |
| 123 | S&F Ceiling Fan Regulator, Electronic Delux step socket type, 230 Volt and Electrically Connecting up, complete all as specified and as directed. |
| 124 | S&F Call Bell, AC, 230 Volts, Single Pole, 230 Volt and Electrically Connecting up, complete all as specified and as directed. |
| 125 | S&F LED Bulb (B-22) suitable for 1x9 Watt Light Fittings in Lamp Holder, complete all as specified and as directed. |
| 126 | S&F Decorative LED Wall Light Fitting made up of polycarbonate suitable for 9 Watt, Retrofit type B-22 Base, IP-66 Protection grade, with and including Inverter type 9 Watt LED Lamp (or nearest Higher Wattage), Electrically Connecting up with and including 3 Core Flexible Copper Conductor Cable of suitable Size and Length, complete all as specified and as directed. |
| 127 | S&F LED Light Fitting 1x9 Watt (or nearest Higher Wattage), 5700 K, Mirror type, 2 Feet Long, Wall/ Surface mounted with PC Housing, Integrated type with High Efficiency PMMA Diffuser & Electronic Driver, Surge Suppressor of 2 KV or more, Operating Range – 140 V to 270 V, 50 Hz, Complete with all Accessories, Internally Pre-wired, Fixed with 02 No. PVC Round/ Square Block, Screws, etc., Electrically Connecting up with and including 3 Core Flexible Copper Conductor Cable of suitable Size and Length, complete all as specified and as directed. |
| 128 | S&F LED Light Fitting 1x10 Watt, Bulkhead Luminaires including LED Light, Driver, Holder, Electrically Connecting up with and including 3 Core Flexible Copper Conductor Cable of suitable Size and Length, complete all as specified and as directed. |
| 129 | S&F LED Light Fitting 1x20 Watt (or nearest Higher Wattage), 6500 K, 4 Feet Long, Wall/ Surface mounted, Square Profile Housing and Polycarbonate Channel including Lithium Ion Battery with Charging Time 08 Hours and Back up Time upto 04 Hours, Decorative type with Integrated High Efficiency Electronic Driver, Operating Range – 140 V to 270 V, 50 Hz, Complete with all Accessories, Internally Pre-wired, Fixed with 02 No. PVC Round/ Square Block, Screws, etc., Electrically Connecting up with and including 3 Core Flexible Copper Conductor Cable of suitable Size and Length, complete all as specified and as directed. |
| 130 | Re-fixing only LED Light Fitting upto 1x20 Watt (Serviceable Light Fitting obtained from Item No. 2.001 here-in-before) on Wall/ Surface mounted, Fixed with 02 No. PVC Round/ Square Block, Screws, etc., Electrically Connecting up with and including 3 Core Flexible Copper Conductor Cable of suitable Size and Length, complete all as specified and as directed. |
| 131 | Re-hanging Ceiling Fan or Re-fixing Exhaust Fan of any description (Serviceable Fan obtained from Item No. 2.003 here-in-before) in any Situation, Electrically Connecting up with and including 3 Core Flexible Copper Conductor Cable of suitable Size and Length, complete all as specified and as directed. |
| 132 | S&F Miniature Circuit Breaker (MCB) 10 Amp to 32 Amp, Single Pole (SP) with rating 240 Volt, 10 KA \"C\" Curve and Electrically Connecting up, complete all as specified and as directed. |
| 133 | S&F Miniature Circuit Breaker (MCB) 32 Amp, Single Pole & Neutral (SPN), \"C\" Series, 50 Hz, 10 kA, 240 Volt and Electrically Connecting up, complete all as specified and as directed. |
| 134 | S&F MCB 40 Amp to 63 Amp, Triple Pole & Neutral (TPN), \"C\" Curve, 50 Hz, 10 kA, 415 Volt and Electrically Connecting up, complete all as specified and as directed. |
| 135 | S&F MCB 100 Amp, Triple Pole & Neutral (TPN), \"C\" Curve, 50 Hz, 10 kA, 415 Volt and Electrically Connecting up, complete all as specified and as directed. |
| 136 | S&F Sheet Metal Enclosure for DB\"s when MCBs to be used 8-way, SPN, 240 Volt, Single Door, Epoxy Based Powder Coated Painted, IP-43 Protected suitable for mounting MCB DP/SPN as Incomer and MCB SP as Out-going with 200 Amp rated Bus-bar, Neutral Bar, Earth Bar, Connecting Cable Links and Electrically Connecting up, complete all as specified and as directed. |
| 137 | S&F Sheet Metal Enclosure for DB\"s when MCBs to be used 4-way, TPN, 415 Volt, Horizontal/ Vertical, Double Doors, Epoxy Based Powder Coated Painted, IP-43 Protected suitable for mounting MCB DP/SPN as Incomer and MCB SP as Out-going with 200 Amp rated Bus-bar, Neutral Bar, Earth Bar, Connecting Cable Links and Electrically Connecting up, complete all as specified and as directed. |
| 138 | S&F Factory made Sheet Metal Enclosure, Single Pole & Neutral with Socket Plug Top, having 2-Pin Earth Plug & Socket, IP-43 Protected with Steel Phosphatised Powder Painted, Fixed with MCB 20 Amp (01 No.) Single Pole (SP), 240 Volt, Flush with Wall Inside the Niches or Out-side on Wall Surface suitable for Mounting MCB\"s, etc. and Connecting up, complete all as specified and as directed. |
| 139 | Disconnecting & Taking down/out Unserviceable LT Cable of any Size and any description from Trenches, Floors, Walls, Bricks, GI Protection Pipes, etc., complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid separately under appro-priate Items. |
| 140 | Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Electric Cable Lines, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 141 | Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps not exc. 150mm Height along the Route of the Electric Cable Lines with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed |
| 142 | M&L Horizontal Boring upto 50mm Bore (dia) suitable for Passing Cable Protection Pipe Under Road/ Foot Path, not exc. 10.00 Metre in a Single Length with necessary Machinery/ T&P, complete all as specified and as directed.NOTE : GI Protection Pipe will be Measured & Paid under appropriate Item. However Hire Charges of necessary T&P will deem to be included in the Quoted Unit Rate. |
| 143 | M&L XLPE insulated, Armoured, Heavy duty, Electric Cable with Aluminium Stranded Conductor, 1100 Volt grade, Cross-sectional Area 25 Sqmm, 4.0 Core, laid in Trenches/ Ducts or Passing through Pipe or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks Protection, Protection Pipe, etc. will be Measured and Paid separately under appropriate Items. |
| 144 | M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (Below, Above and Around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in Depth before Laying the Cable and 15 Cm in Depth after laying the Cable) and Consolidated (Punned) upto 180mm thickness, complete all as specified and as directed. NOTE : Punned thickness of Sand Cushioning only will be Measured for Payment. |
| 145 | Supply & laying Kiln burnt Sub-class ‘B’ Bricks of Size 230x115x75mm for Covering to UG Cable Protection, Laid Flat Transversally Width Equal to the Length of the Cable, complete all as specified and as directed. |
| 146 | M&L Galvanised Steel Tubing Pipe 40mm bore (dia), Light grade with Bend, laid in Trenches or Under Roads/ Flooring/ Culverts, etc., complete all as specified and as directed. NOTE : Necessary Earthworks will be Measured and Paid separately under appropriate Items. |
| 147 | M&L Galvanised Steel Tubing Pipe 40mm bore (dia), Light grade with Bend, fixing to Electric Poles with suitable Size Mild Steel Flat Iron 40x4.0mm Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed. NOTE : Cost of Mild Steel Clamps, Bolts, Nuts, Washers, etc. will deem to be included in the Quoted Unit Rate. |
| 148 | M&L Earthing Complete with Galvanised Earth Plate Electrode 600x600x6.0mm thick buried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connectedto Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of Size 450x450x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing including Taking down/ out Old Unserviceable Earthing of any description, complete all as specified and as directed. |
| 149 | Removing of excavated materials (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 150 | SCHEDULE OF CREDIT |
| 151 | DEDUCT \"TOTAL AMOUNT OF CREDIT\" AGAINST \"SCHEDULE OF CREDIT\"Bidder(s) shall/ will Quote the EQUAL AMOUNT (as per SCHEDULE OF CREDIT of Tender Documents) under Column \"UNIT RATE\" (M) against Row No. 162 . |