Repairing And Renovation Work At Benfed Bardhaman Branch Office, Purba Bardhaman I- 1 CIVIL WORKSDismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. upto 150 mm. thickRoof 2 1st Floor 3 Ground Floor 4 Dismantling all type of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing as directed within lead of 75m 1st Floor 5 Ground Floor 6 Dismantling R.C. Column, beams,wall etc. Including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars.1st Floor 7 Ground Floor 8 Stripping off worn out plaster and raking out joints of walls, celings etc.upto any height and in any floor including removing rubbish with in alead of 75m as directed 9 Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge 10 Cleaning the exposed reinforcement preferably upto full diaMeter by wirebrush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturers specification] [Mode of measurement:The affected surface area of reinforcement shall be considered for payment] 11 Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge 12 Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturers specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface). 13 Scraping of moss, blisters etc.thoroughly from exterior surface of wallsnecessitating the use of scraper, wire brush etc.(Payment against thisitem will be made only when this has been done on the specific directionof the Engineer-in-charge) 14 c) Extra rate for careful dismantling andrecovering at least 150 no of useable bricks per cum. 15 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement ifany, in ground floor as per relevant IS codes.(i) Pakur Variety 16 Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. 17 M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for Each additional floor or 4m. beyond initiial 8m. or part thereof.III) For built up sections / srtuctural members of specified sectionsweighing not less than 22.5 Kg./m ISMB 300(300*140*13.1) 18 Reinforcement for reinforced concrete work in all sorts of structuresincluding distribution bars, stirrups, binders etc initial straightening andremoval of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawingand direction. 19 Guniting concrete surface with cement mortar (25mm nominal thick) applied with compressor after cleaning surface and spraying with epoxy complete as per Technical specification. 20 Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy. 21 Sealing of cracks / porous concrete by injection process through nipples/Grouting complete as per Technical specification.A Cement Grout 22 B Cement mortar (1:1) Grouting 23 Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size withhexagonal square mesh wire netting, I.R.C. fabric mesh or X.P. M. fitted andfixed after tying the existing reinforcement on concrete without distributingthe same and with proper scarping and cleaning the reinforcement anddisturbed concrete with wire brush etc. after applying a coat of cementincluding the cost of wire netting I.R.C or X. P. M. & cost of all handling andscaffolding complete as per direction of Engineer-in -charge.b) 25 mm thick 24 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed andraking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](i) With 1:6 cement mortar - (b) 20 mm thick plaster ( EXTERIOR)Ground Floor 25 1st Floor 26 Roof 27 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed andraking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](i) With 1:4 cement mortar - (b) 15 mm thick plaster ( INTERIOR)Ground Floor 28 1st Floor 29 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed andraking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](i) With 1:4 cement mortar - (b) 10 mm thick plaster( INTERIOR)Ground Floor 30 1st Floor 31 Acrylic Distemper to interior wall, ceiling with a coat of solvent basedinterior grade acrylic primer (as per manufacturers specification)including cleaning and smoothning of surface.Two CoatsGround Floor 32 1st Floor 33 Applying Acrylic Emulsion Paint of approved make and brand on wallsand ceiling including sand papering in intermediate coats including putty(to be done under specific instruction of Superintending Engineer) :(Two coats) i) Standard QualityGround Floor 34 1st Floor 35 Applying Exterior grade Acrylic primer of approved quality and brandon plastered or cencrete surface old or new surface to receivedecorative textured (matt finish) or smooth finish acrylic exterioremulsion paint including scraping and preparing the surface throughly,complete as per manufacturers specification and as per direction of theEIC.Ground Floor 36 1st Floor 37 Mumty Room 38 Protective and Decorative Acrylic exterior emulsion paint of approvedquality, as per manufacturers specification and as per direction ofEngineer-in-Charge to be applied over acrylic primer as required. Therate includes cost of material, labour, scaffolding and all incidentalcharges but excluding the cost of primerGround Floor 39 1st Floor 40 Mumty Room 41 Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohrs hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sq.m. or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sq.m. below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make asdirected and removal of wax coating of top surface of tiles with warm water andpolishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to themanufacturers specification and direction of Engineer-in-Charge. (Whitecement, synthetic adhesive and grout material to be supplied by the contractor). a) In Ground Floor: Sizes-300 mm x300mm x10 mm with breaking strength >1200 NGround Floor 42 1st Floor 43 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of Each tile upto 0.09 Sq.m (i) Coloured decorativeGround Floor 44 1st Floor 45 Dismantling Orissa pattern W.C. including taking out of base concrete, if necessary, complete.TOTAL 46 Dismantling urinal. 47 Dismantling wash basin with brackets with or without waste fittings. 48 Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc.(b) With S trap 49 Supplying, fitting and fixing Closet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete.(a) E.W.C.(ii) Plastic (hallow type) white 50 Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.- 470 mm X 280 mm X 340 mm 51 Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets.550 mm X 400 mm size 52 Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. 53 Supplying, fitting and fixing urinal flush pipe fittings of approved brand.(a) C.P. urinal flush pipe fittings range of one 54 supplying,fitting and fixing best quality Indian make mirror 5.5mm thick with silver in gas per I.S.I. specification ssupported on fibre glass frameofany colour, frame size 550 mm X 400 mm 55 Supplying, fitting and fixing soap holder..PTMT(Prayag or equivalent) 56 Supplying fitting & fixing C.P. towel rail with brackets complete - 25mm dia., 600mm long 57 Supplying, fitting and fixing pillar cock of approved make.a) PTMT Pillar Cock - 15 mm. 58 Supplying, fitting and fixing dome shaped C.P. waste grating for urinals - 50mm. 59 Supplying, fitting and fixing Waste fittings complete.(a) C.P. over brass - 32 mm 60 Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe,with PVC coupling at one end fitted with necessary clamps.(i) 900 mm long 61 Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder batsclamps, including cutting pipes, making threads,fitting, fixing etc.(a) For Exposed Work,PVC Pipes(i)15 mm 62 (ii)20 mm 63 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (iii) 160 mm. Dia. 64 B) UPVC Fittings: c) Bend (iii) 160 mm. Dia. 65 d) Shoe (iii) 160 mm. Dia. 66 Supplying, fitting and fixing bib cock or stop cock.(i) Chromium plated Bib Cock long body with wall flange with aerator(Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand) 67 Chromium plated Stop Cock (Equivalent to Code No. 513(A) &513(B) & Model - Tropical / Sumthing Special of ESSCO or similar 68 (c) Chromium plated Hand shower 70mm dia Round Shape Single flowwith Flexible Tube & fittings(Equivalent to Code No. ESH-5512 & Model -Tropical / Sumthing Special of ESSCO or similar). 69 Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately)(a) Upto area 2.5 Sq.m 70 Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Local 71 Panel shutters of door and window, as per design (Each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.In ground floor.(iv) 25mm thick shutters with 12mm thick panel of size 30 to 45 cm.(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. 72 Removing old paint from blistered painted surface of steel or other metalby chipping including scraping and cleaning and exposing the originalsurface. 73 Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : With super gloss (hi-gloss) (i) Two coats (with any shade except white) 74 (b) On steel or other metal surface : 75 (b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sandpapering etc. 76 Rendering the Surface of walls and ceiling with White Cement baseWATER PROOF wall putty of approved make & brand.(1.5 mm thick) 77 (a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand 78 (b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint havingadhesive & waterproofing properties by mixing in proportion (1 liquid: 4cementitious material) or as per manufacturers specification for waterproofing layer in water tank etc. (No Departmental Cement is required) 79 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In- Charge. 80 Renewing worn out putty of glass panes :a) Panes not exceeding 0.2 Sq.m 81 (b) Panes exceeding 0.2 Sq.m but not exceeding 0.5 Sq.m 82 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. ii) 4mm thick coloured / tinted / smoke glass 83 Supplying fitting and fixing in position including all cost of materials, labour etc. as directed complete a) M.S. Clamp 40mm x 6mm x 125mm upto 170mm length 84 b) Iron butt hinges 75mm x 40mm x 1.12mm 85 c) Iron butt hinges 100mm x 58mm x 1.90mm 86 d) Anodised aluminium catch hook-150mm long 87 e) Anodised aluminium socket bolt-100mm long x 10mm dia. 88 g) Iron hasp bolt,16mm dia. - 300mm long 89 i) Iron door ring -75mm dia. 90 j) Wooden hinge cleat (sal) - 75mm long including 62mm long iron butt hinge 91 k) Wooden buffer block (sal) - 125mm long 92 Filling up cracks with cement mortar (1:3) at the junction of the out side wall and drain. (Cement 11.4 Kg/100 Mtr.) 93 Labour for Chipping of concrete surface before taking up Plastering work. 94 Brick work with 1st class bricks in cement mortar (1:6)(a) Above plinth level 95 ELECTRICAL WORKSSupplying and fixing Sheet steel 60/63 A Main Switches 415V TPN with fuse on L&N on flat iron frame on wall [Approved make] as directrd by EIC. 96 Supplying & fixing sheet metal (16 SWG) Iron Clad 4 bars 415 V, 100/125 A (Cu. bars) Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991) [Approved make] 97 Supplying and fixing double door Horizontal 4 way TPN MCB Distribution board with IP-42/43 protection, on wall surface & mending good thedamages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [Approved make] 98 Supplying and fixing 240/415 V 63A FP MCB Isolator on din rail of existing for TPN DBs and necessary connection. [Approved make] 99 Supplying and fixing 240/415 V 6-32A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing for TPN DBs and necessary connection. [Approved make] 100 Wiring With PVC Insulated & Unsheathed Single Core Stranded Copper Wire ‘FR – in PVC Casing-Capping (Precision Make) on wall/ceiling (a) {2 x 4 Sq.m.m + 1 x 2.5 Sq.m.m} for [Approved make] 101 (b) {2 x 2.5 Sq.m.m + 1 x 1.5 Sq.m.m} for [Approved make] 102 (c) {3 x 1.5 Sq.m.m} for[Approved make] 103 Distribution wiring in 1.1 KV single core stranded FR PVC insulated & unsheathed copper wire [Approved make] in 25mm size PVC rigid conduit FR (Precision make) incl. necy. fittings as required, {4 x 6 Sq.m.m + 2 x 4 Sq.m.m} 104 Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 Sq.m.m) single core stranded FR PVC insulated & unsheathed copper wire [Approved make]in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 Sq.m.m) single core stranded FR PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top coveron wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface] (a) Average run 5 mtr 105 (b) Average run 8 mtr 106 Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 Sq.m.m) single core stranded FR PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 Sq.m.m) single core stranded FR PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light point with 2 no. 2 way piano key type switch fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casingcapping and Switch board both on surface], Average run 10 mtr 107 Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 Sq.m.m) single core stranded FR PVC insulated & unsheathed copper wire [Approved make]in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 Sq.m.m)single core stranded FR PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to 5A 3 pin flush type plug socket with piano key type switch (Anchor make) fixed on sheet steel fabricated CRC MS switch board with bakelite/perspex (wall matching color) top cover of 3 mmthick flushed in wall by housing the board after cutting brick wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface] (a) On Board 108 Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch[Approved make] on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board andbakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required 109 Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB[Approved make]on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. 110 Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Approved by Make) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex coverand making necessary connections as required. 111 Supply & Fixing 240 V, 25 A, Modular type starter [Approved make] with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. 112 Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket [Approved make], without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. 113 Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator [Approved make] & necy. Connections. 114 Supplying & Fixing 240 V AC/DC superior type Multitune ( min 10 nos. tune) Call Bell (Anchor) with selector switch for single/Multi Tunes mode, Battery operated on HW board incl. S&F HW board 115 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long By TATA-Medium GI pipe 116 Extra for providing masonery enclosure on the top of the earth electrode of overall 117 Extra for treatment of soil by using salt & charcoal or coke for plate electrode 118 Excavation of soil for installation of Earth Electrode and filling & ramming. For For Morrum Soil 119 Connecting the equipments GI pipe to earth busbar including S & F10 SWG. GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages 120 Connecting the equipments to earth busbar including S & F 14 SWG. GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages 121 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required 122 Fixing only single/twin fluorescent light fitting suspended 25 cmbellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG)supports fixed with “L” type MS clamp whose one side fixed onceiling with sutable size 4 nos. fastener and other side connectedwith the conduit with suitable size of bolts and nuts incl. S&F EIconduit, “L” type (125mmx125mm) 6mm thick and 25mm with MSclamps and connecting the length of PVC insulated wire andmending good damages to original finish and painting etc. by2x24/0.20 mm (1.5Sq.m.m.) flexible copper wire of 1.10 mt. length. 123 Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5Sq.m.m.) flexible copper wire of 1.10 mt. length. 124 Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required 125 Fixing only bulk head ceiling fitting on wall /ceiling by screws etc. 126 Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) 127 Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 Sq.m.m flexible copper wire. 128 Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 Sq.m.m flexible copper wire 129 Supply & Fixing Socket type fan regulator (Step type) [Approved Make] on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connectionsetc. 130 Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length 131 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diaMeter 23 cm (9) 132 Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 23 cm (9) 133 Supplying and fixing PVC casing-capping [Precision Make] onwall or ceiling, incl. necy. PVC fittings etc. and mending gooddamages to building works (a) 20x10mm Size 134 (b) 25x10mm Size 135 Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl.bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works, 175 mm x 100 mm x 65 mm 136 SUPPLY OF FITTINGS LIGHT and FANFIRE EXTINGUISHER:Supplying & fixing 2x20W T8LED light with Batten fixture.CROMPTON MAKELED Batten (IGP162 LT8-162xT8) & LED Aluminium 20W T8 tube (LGT8-20-865-2) or equivqlent model of PHILIPS /BAJAJ / HAVELLS as per direction of EIC. 137 Supplying & fixing Centura Neo LED Flood Light 50 W 6500 K IP66 LED Flood light suitable for industrial area lighting.HAVELLS MAKE (LHEECNP7PB6J050) or equivqlent model of PHILIPS /BAJAJ / CROMPTON as per direction of EIC. 138 Supplying & fixing 10W LED Bulkhead light fixture.CROMPTON MAKE(CIS-306-10-57-SL-DP-NBK) or equivqlent model of PHILIPS /BAJAJ / HAVELLS as per direction of EIC. 139 Supplying & fixing1400 mm sweep Ceiling Fan. HAVELLS MAKE (FHCSV1SBRN56) or equivqlent model ORIENT/ CROMPTON/USHA make as per direction of EIC. 140 Supplying & fixing 400MM sweep Wall Fan (cabin fan). HAVELLS MAKE (FHWSW4SIVR16) or equivqlent model ORIENT/ CROMPTON/USHA as per direction of EIC. 141 Supplying & fixing 230MM sweep (9) Exhaust Fan. EPC MAKEor equivqlent model ORIENT/ CROMPTON/USHA or equivalent make as per direction of EIC. 142 Supply,, Installation, Testing & Commissioning of 6.0Kg ISI marked ABC Dry powderextinguisher (Stored Presser Type) consisting of welded MS cylindrical body, squeeze, lever discharge valve, fitted with internal discharge tube, high pressure discharge hose, discharge nozzle, suspension brack. 143 Dismantling of damaged existing electrical wiring before taken up. 144 Add 18% G.S.T. + 1% L.W.Cess