Tender For Special Repair To Building No P-07 At Dca Sadar Under Ge(West) Bareilly.; 1 M & L fornon-skid ceremic colouredtiles7 to 8 mm thick(Square/rectangular) areaof each tile exceeding0.18 Sqm but not exceeding 0.38 Sqm in floors etc set and jointedin neat cementslurry and pointed in whiteor colouredcement to match of tiles and screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 for laying floor finishes incl dismanlting of existing flooring completeall as specified. 2 All as per serial item No 1 as above but as in vertical surfaces of tiles and rendering 10 mm thick in cement mortar 1:4, as in backing layer complete all as specified. 3 M & L for non- skid ceremic colouredtiles7 to 8 mm thick(Square / rectangular) areaof each tile exceeding0.11 Sqm but not exceeding 0.18 Sqm in floors etc set and jointedin neat cementslurry and pointed in whiteor colouredcement to match incl dismantling of tilesand screed bed or bedding layer of mortar 15mm thick in cement mortar 1:6 for laying floor finishesall as specified. 4 M&L for Glazed (plain /coloured) ceramic tiles wall 600x300x7mm thick on vertical faces of walls including 10mm thick rendeingin CM 1:4 set jointed in neat cement slurry and pointed in coloured cement to match including taking down old dado/skirting complete all as specified. 5 M&L for Providing & injecting chemical for post construction ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in a portion with cement mortar 1:2 to match the existing apron complete all as specified and directed. 6 M & L for Post Construction Anti TermiteTreatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor sall as specified and directed. 7 Taking down chowkats with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each including making good disturbed portions of wall with new or old bricks, lintel,cills, etc in CM 1:4 complete all asspecifiedand directed. 8 Taking down chowkats with shutters (without taking off shutters from the frames) area exc 1.5 Sqm each and not exc. 4.00 Sqm including making good disturbed portions of wall with new or old bricks, lintel,cills, etc in CM 1:4 complete all asspecifiedand directed. 9 Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. complete as specified by the manufacturer and as per directions of Engineer-in-charge. 10 Supply and fixing 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856 complete all as specified by the manufacturer and as per directions of Engineer- in-charge. 11 S&F for 125x60mmx2mm thick pressed steel, frames for door with one or more rebates including filingand inner surface of the frame shall be treated with a coat of bituminous paint & compaction with PCC 1:3:6 Type C1, necessary fixing lugs, SS hinges, lock strike plate, 02 x MS bar/flat at bottom of the frame etc, complete including wooden texture finished paint on the frame surface all as specifiedand directed. 12 S&F for 105x60mmx2mm thick pressed steel, frames for door with one or more rebates including filing andinner surface of the frame shall be treated with a coat of bituminous paint & compaction with PCC 1:3:6 Type C1 necessary fixing lugs, SS hinges,lock strike plate, 02 x MS bar/flat at bottom of the frameetc, including wooden texture finished paint on the frame surfacecomplete all as spd and directed. 13 S&F for 30 mm thick Factory made flush shutter, solid core construction with block board core and ply wood face panels, commercial type on both side, complete all as specsified & directed. 14 M & L for 35 mm thick plain framed glazed and skeleton shutter open rebated& prepared to receive glass, gauge etc, with sash bar edges of framingplain chamfered or rounded fitted with cut and mitered beads for securing glass including campsule mesh tightly fixed with the glazed and skelton door shutter etc, of 2nd class hard wood, members of shutters as specified in SSR Part - ISection 8 clause 8.24 (a) fitted to chowkats all as specified and directed. Note:- Campsule Mess will be measured and paid separately. 15 S&F in repairs factory made PVC Cupboard frame of the size 75mm x 40mm with a wall thickness of 5mm, made out of extruded 5mm thick plain/prelam PVC sheet of density 600 kg/cbm, having bottom width of 50mm and thickness of 10mm. All four frame lengths reinforced with 15 mm x 15mm M. S. square tubes of 19 gauge thickness throughout the frame and mitre cut at two corners adjointed with 2 nos. of 15mm long brackets 0f 10mm x10mm M S square tubes. The door frame shall be fixed to the wall using 8/100 long M S screws through the frame by using PVC fasteners. A minimum of 4 nos. of screws to be provided for each vertical member and minimum of 2nos. of screws to be provided horizontal member etc. complete as per direction of Engr-in-Charge, manufacturers specification and drawing. 16 S&F in repairs factory made PVC cupboard flush type shutter of 30mm thick consisting of frame made out M S tubes of 19 gauge thickness and size 19mm x 19mm for stiles and rails. The inside panel shall consist of 20 mm thick multichamber hollow PVC section of 1mm wall thickness, bonded using solvent cement/ cynoacrylate adhesive with 5mm thick plain/prelam PVC sheet, on both side of inside panel incliding necessary items to fix the shuter to frame such as 100mm stailess steel hinges, 100 mm long handles made of anodised aluminium and magnetic ball catch for each pair of shutter.All four edges of the panel to be sealed with lipping of 10mm thick and 20mm wide PVC sheet baton (made by sticking 2nos. PVC foam sheet of 5mm thickness using PVC solvent cement adhesive).complete as per direction of Engr-in-Charge. 17 S&F for fancy type 200 mm long stainless steel handles etc, complete all as specified and directed 18 S&F for 100mm long stainless steel butt hinges complete all as specified and directed. 19 S&F for 150mm long aluminum anodised, barrel tower bolts of extruded section and fixed. 20 S&F for 200mm long aluminum anodised, barrel tower bolts of extruded section and fixed. 21 S&F for 150mm long Extruded aluminium alloy handles, fabricated type, anodised 22 S&F 150 mm long floor door stopper of aluminium alloy body and tongue, brass body and tongue with hard drawn steel spring fixed in floor complete all as specified and directed. 23 S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as spd and directed. 24 S&F galvanised Stainless steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanesed wire stapels complete all as specifed and directed. 25 S&F 300 mm size, MS ordinary rat tail rod pattern springs including roller and roller plate complete including fixed to wooden and steel chowkats. complete all as specifed and directed. 26 M&L Preparation of oldwooden surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint. complete all as specifed and directed. 27 M&L painting to wood and wood based surfaces of any description exc 10cm with or girth with two coats of synthetic enamel paint over a coat of pink primer including preparation of newly or previously untreated surface complete all as specifed and directed. 28 M & L preparation of old steel surfaces of any description over 10 cm inwidth or girth and applying one coat of synthetic enamel paint complete all as specifed and directed. 29 M&L forpainting to steel surface exc 10 cm width or girth with two coats of synethic enamel paint over a coat of red oxide primer including preparation of newly or previously untreated surface complete all as specifed and directed. 30 M & L for Plain Cement Concrete 1:3:6type C-1(using 20 mm graded aggregate) as in bed blocks for hold fast/concrete filling in chowkhats and similar work etc complete all as specified and directed. 31 M&L 15mm thick cement plaster on brick surfaces or concrete surfaces (on external surface) in cm (1:4) using WPC@ 3% per 50 kg of cement including taking down plaster finishing the surface even and smooth without using extra cement and necessary scaffolding all as spd and directed, 32 M&L 15mm thick cement plaster on brick surfaces or concrete surfaces (on external surface) in cm (1:4)using WPC@ 3% per 50 kg of cement newly surface even and smooth without using extra cement and necessary scaffolding all as spd and directed 33 M&L 12mm thick cement plaster on brick surfaces or concrete surfaces (on internal surface) in cm (1:6) including taking down plaster finishing the surface even and smooth without using extra cement and necessary scaffolding all as spd and directed 34 M&L 12mm thick cement plaster on brick surfaces or concrete surfaces (on internal surface) in cm (1:6)newly surface even and smooth without using extra cement and necessary scaffolding all as spd and directed 35 M & L for rendering 5mm thick on ceiling or concrete surfaces in cement mortar (1:3) finished including taking down plaster the surface even and smooth withoutusing extra cement and necessary scaffolding complete all as spd and directed 36 M & L for rendering 5mm thick on ceiling or concrete surfaces in cement mortar (1:3) newly surface even and smooth without using extra cement and necessary scaffolding all as spd and directed 37 M&L white washing three coats on ceiling surfaces including preparation of newly plastered untreated surfaces and necessary scaffolding all as spd and directed 38 M&L for applying 1 mm thick layer of wall care putty on external and internal wall surfacesincl rubbing down the surfaces with sand paper after getting dried all as directed to obtain a smooth & even surface complete all as spd and directed. 39 M&L Preparation of old decorated surfaces and applying three coat of white wash on ceilings surfaces and rubbing down with sand paper to have even and smooth surfacesall as specified & directed by Engr-in-Charge. 40 M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment and applying two coats of oil bound distemper using Airless spray technology operating single spray gun paint usage over a coat of 1 mm thick layer of wall care puttyand certified by paint manufacturer and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower complete all as specified and directed. 41 M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper using Airless spray technology of operating single spray gun and paint usage over a coat of 1 mm thick layer of wall care puttyand certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface to achieve excellent application using limited manpower complete all as specified and directed. 42 M&L for preparation of old plastered surfaces of walls by complete removal of existing treatment and applying two coats of exterior weather proof paint using Airless spray technology operating single spray gun paint usage over a coat of 1 mm thick layer of wall care puttyand certified by paint manufacturer and as mentioned in PS and accessories for applying weather prrof paint should be able to spray in hard to reach areas and penetration of paint on the surface to achieve excellent application using limited manpower complete all as specified and directed. 43 M&L for preparation of new plastered surfaces of walls and applying two coats of exterior weather proof paintusing airless spray technology of operating single spray gun and paint usage over a coat of 1 mm thick layer of wall care puttyand certified by paint manufacturer and as mentioned in PS and accessories for applying weather proof paint should be able to spray in hard to reach areas and penetration of paint on the surface to achieve excellent application using limited manpower complete all as specified and directed. 44 Demolition of brick work or stone/boulder masonry built in cement mortar or cement limemortar including all quoins, aches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles all as spd and directed 45 M&L brick work with fly ash bricks straight or curved on plan exc 6 m mean radius built in CM (1:6) all as spd and directed 46 M&L brick work with fly ash bricks straight or curved on plan to any radius in half brick thick walls built in CM (1:4) all as spd and directed 47 M & L for cutting chases of hanging chajjas, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges ofsunshades, shelves, lintels, Chajja ( up to IIIrd floor) etc making good, cutting out exc 10cm and not exc 40cm girth in RCC chajjas in brick walls complete all as specified and as directed. 48 Demolition of reinforced cement concrete, (other than ground floors), shelves, chajjas, slabs and stair case similar work carefully and matching to adjoining disturbed surfaces complete all as specifed and directed. 49 Demolition of reinforced cement concreteof any description and in any position not otherwise specifically provided complete all as specifed and directed. 50 M & L form work to edges of concrete rough finished surface flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide. 51 Form work to soffits of suspended slabs flat surface of concrete finishedrough surfaces of concrete not exceeding 200mm thick, complete all as specified and directed. 52 M & L formwork to sides and soffits of lintels,lintel bend, beams etc finished rough surfaces of concrete complete all as specified. 53 M & L formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular finishes rough surfaces of concrete.etc finished rough surfaces of concrete complete all as specified. 54 M & L formwork to chullah hoods, chajjas, trough and similar items including edges finished rough surfaces of concrete complete all as specified. 55 S&F TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia. complete all as specifed and directed. 56 S&F TMT bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders bent to shape required,including binding with mild steel wire (annealed) not less than .9mm dia. complete all as specifed and directed. 57 M&L RCC 1:2:4 type B1 using 20 mm graded aggregate as in slab, shelves and stair case etc.all as specified and directed. 58 M&L RCC type B 1, 1:2:4 (20mm graded agg) as in beams, cantilevers, lintels, over 1.5 m span. complete all as specifed and directed. 59 M&L RCC type B 1, 1:2:4 (20mm graded agg) as in columns, pillars, piers, posts and struts. complete all as specifed and directed. 60 M&L RCC 1:2:4 type B1 using 20 mm graded aggregate as in chajjas and like all as specified and directed. 61 Dismantling of concrete by chiseling from RCC members like column , beam, parapet facia, chajja, ceiling,etc exposing the reinforcement without disturbing the reinforcement free from rust by sand blasting/using chemical, apply a coat of rustolin to remove rust and acralic polymer on old rusted reinforcement proving at places addl reinforcement welding with existing reinforcement as directed wherever required binding RCC 50 mmx 50 mm (10 mm gauge welded mesh ) & tack , securing with clips / linding wire, welding & provision guniting pressure 2.2 to 2.5 kg /sqm with admixer 1 cement 3.5 of sand of thickness 25 to 40 mm including stripping floating with wooden strippers for proper dimension control neccssary form work & scaffolding up to three storey and including height of head room complete surface of guniting to be finished fair with 10 mm thick plaster in cement mortar 1:4 with water proofing compound @ 200 ml every 50 kg of cement and applying two coat of Dr fixit /pidilite new coat ezee at interval of 8 hours cure for thesurfaces completeall as spd as directed. Water proofing Compound :-Dr Fixit (Pidiproof LW+ or pidicrete URP). 62 Demolition of cement concrete(un-reinforced), in any position and paving n.exc. 15 cm thickness (below or above ground level) including tile/ terrazzo floor complete all as specified and directed. 63 M & L for plain cement concrete 1:3:6typeC-1(using 20mm graded stone aggregate) as in plinth protection 75 mm thick finished even and fair including forming 10 mm wide joints at not exceeding 3 m distance between adjoining slabs shall not exceed 10 mm in thickness and shall be filled with bitumen mastic i.e. bitumen and sand in proportion 1:2 all as specified or as directed. 64 M & L for Providing water proofing treatment to RCC sunken slab as specified and directed as under:- (a) Cleaning the existing RCC sunken slab and vertical wall/RCC beam and hacking the surface. (b) 15mm thick plastering over the floor & vertical surface in CM 1:4, mixed with liquid water proofing compound @ 200ml per 50 kg of cement trowelled to even and smooth finish without using extra cement .(Water proofing compound shall be measured and paid separately). (c ) filling the sunken portion with water for 72 hrs and carring out the ponding test.(Any leakage /seapage noticed shall be repaired). (d) Applying two coats of elastomaric acrylic water proof coating Make: Dr. Fixit of pidiproof LW+ or equivalent per sqm in each coat with roller application.(Note: Each coat of elastomaric acrylic compound requires 6-8hrs to dry up itself second coat shall be applied on getting the first coat completely dried up.) 65 Supply only liquid waterproofing compound all as specified. Make : Dr. Fixit (pidiproof LW+) 66 M&L for cement concrete type E2 1:5:10 (40 mm graded aggregate) as in mass concrete complete all as specifed and directed. 67 S&F 32mm dia GI pipe, medium grade as in spout pipe in sunken floor complete all as specified and directed. 68 M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate as in levelling course, haunching, coping and similar works of over RCC roof surface including rounded or chamferred on edges etc all as specified and directed. 69 M&L for 15 mm thick rendering on fair faces of concrete surfaces in CM 1:4 with water proofing compound concrete surface complete all as specified and directed.(NOTE:- WPC shall be measured and paid separatly) 70 Dismantling of roof terracing cement / brickconcrete (un-reinforced) and existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land complete all as specified. 71 M&L 25mm thick cement concrete type B1 1:2:4 using 20mm graded stone aggregate in floor finishes even and fair to receive floor tiles. complete all as specifed and directed. 72 Supply and providing water proofing treatment with polyster based water waterproofing membrane standard water proofing membrane 3 mm thick, wt not less than 3.5 kg/ sqm having 10 years guarantee for water tightness all as specified and directed and described as under : (a) Prepartionof RCCroof surface and applying one coat of polymer modified bitumen 85/25 @ 1.2 Kg/Sqm over a coat of polymer primer @ 0.30 Kg/Sqm including cleaningsurface, all as per manufactures specification complete all as specifiedand directed.(b) Supply & Providing APP based polyster based water waterproofing membraneminimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced/ torch application of membrane with 10 cm overlaps as required thereof, complete all as specifiedor as directed. Make :- IWL Hyperplas Polyster (M/S IWL), Super Thermolay (M/S STP Limited), Torch Shield AP by Pidilite Industries. 73 M & L for applying one coats of Bitumen based UV reflective and water proofing paint with aluminium finish over APP membrane and maximum coverage 8.00 Sqm per litre per coat on non assessible roof over APP membrance complete all as specified. 74 M & Lfor heat reflective weathering tile minimum 250 x 250 x 15 mm thick, fixed withneat cement slurry overlaid over 15mm thick screed bed in cementmortar 1:4 on roof top and joints shall be 4mm wide, sealed with 2 mm deep polysulphide compound (sealing compound) complete all as specified and directed. 75 M&L for20mm thick Granite (Z- black colour only) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. stone including grinding and polishing and 15mm screed bed in cement mortar 1:6 including dismantling of tiles, hearting etc complete all as specified. 76 M&L for20mm thick Granite (Z- black colour only) machine cut and machine, polished,and moulding,window cills, riser of steps and urinal partition wash basin platforms and flooring, skirting/ dados like in cement mortar(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of marble laid over cement screed and jointed with grey cement slurry mixed with pigment to match including rubbing & mirror polishing ding and inclucding 10mm thick cement plaster on brick surfaces or concrete surface in cm (1:4) finished even and rough as screed and dismantling of wall tile including cement mortar bedding complete all as spd and directed. 77 M & L for 20-25 mm thick machine cut pre polished kota stone slab flooring laid under stairs soffits area and jointed with grey cement slurry fixed with pigmentto match to shade of the slab including rubbing and mirror polishing over and or 20 mm thick bedding layer of cement mortar 1:6 for laying floor finishes even and rough with and including dismantling floor, hearth or wall kota stone slab including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed. 78 M&L for 20-25mm thick machine cut pre polished kota stone slab in riser of steps skirting, dado and pillar,landing in single piece with round nosing with three numbers of serration using as front door steps, laid over cement screed and jointed with grey cement slurry mixed with pigment to match including rubbing & mirror polishing ding and inclucding 10mm thick cement plaster on brick surfaces or concrete surface in cm (1:4) finished even and rough as screeddismantling of wall tile including cement mortar bedding complete all as spd and directed. 79 Rounding to edges of stone slabs one edge, such as in steps , cooking platform, and other similar situations complete all as specified and directed 80 S&F in repair vitreous china squatting pan of orrissa pattern long pan size580 x 440 mm white with Por S trap size100 mm dia front or back inlet and integral foot rest any pattern (excluding flushing cistern and flush pipe) including provn of lime concrete bedding (1:2:5), minimum 150mm all round and finish just below level of rim of pan complete all as specified and directed. 81 S&F in repair PVC low level flushing cistern 10 litres, valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flushing pipe complete all as specified and directed.Make :- Sleek fresh dual flush of Hindware Model No Pastel size 47.6x15.5x32, Parryware Cat No 8177*, CeraCat No B1810110 fittings snow white 82 S&F in repair fancy type chromium plated brass angle valve type suitable for 15mm bore pipe complete all as specified and directed. 83 S&F in repair 15 mm dia bib tap fancy type chromium plated with flange quarter turn incl all necessary fittings complete all as specified and directed. 84 S&F in repairs 450mm long PVC connection 15mm bore with PTMT nuts complete all as specifed and directed. 85 S&F for 20 mm bore CPVC water tubing with all fittings medium grade and fixed complete to wall and ceiling or laid in floors incl taking down of existing pipe line of any description complete all as specified or as directed. 86 S&F for 25 mm bore CPVC water tubing with all fittings medium grade and fixed complete to wall and ceiling or laid in floorsincl taking down of existing pipe line of any description complete all as specified or as directed. 87 S&F in repairs 0.8 mm thick kitchen or laboratory sinks made of stainless steel (304 grade) with plugs, washers and wastes including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm etc complete all as specified and as directed . 88 S&F in repairs 75 mm x 32 mm dia chromium plated waste fitting special size suitable for stainless steel sinks including PVC flexible waste pipe of approvedquality complete all as specified and directed. 89 S&F in repairs 100mmx100mm stainless steel grating fixed complete all as specified and directed. 90 S&F in repair fancy type stainless steel towel rack size 600mm long including a pair of brass bracket complete all as specified and directed. 91 S & F stainless steel plate rack not less than 5 Kg of size 31X36X10 complete all as specified and as dirrected. 92 S&F in repairs vitreous chinaware coloured wash hand basin with padestal of size 55X40X82cm complete including CP Waste coupling ,waste pipe ,complete fixing arrangementand cutting for and pinning in walls & making good complete all as specifed and directed by Eng in charge. 93 S & F in repair fancy type 150mm size square brass CP shower rose with or without swivel joints complete all as specified and as directed. 94 S&F Brass chromium platedwall mixer 2 in 1, 15mm for mixing hot & cold water incl provision of over head shower, screwed down three joints to steel pipes or unions and plugging and screwed to walls incl necessary fitting and taking down of oldPVC tap complete all as specified and directed. 95 S&Ffancy type 15mm dia chromium plated fancy type wall mixer hot & cold with long swan for kitchen sink fixing and connection to pipes incl necessary fitting and takinf down of old PVC taps complete all as specified and as directed. Model :- Cera cat Part No:-1016501 ,Kerovit Cat Part No KB411019 & Asian Paints Cat Part No SYSM101. 96 S&F in repair fancy type brass chromium plated soap dish of 160x160x90 mm complete all as specified and directed. 97 S&F in repairs designed looking mirror area exc 0.54 sqm to 0.75 sqm of selected quality 6mm thick glass, mounted on fixed to wall with CPplugs with chromium plated brass screws and cup washers, complete all as specified and as directed. 98 S&F in repairs PVC corner set of three of size (12X12 ,9X9 and6 X6 ) with railling and complete all as specified and directed. 99 S&Ffancy type 15 mm bore brass chromium plated WHB mixer for mixing hot and cold water screwed down for iron pipe and fixed to WHB including taking out existing PVC pillar tap from old WHB complete all as specified and directed.Make :ARI 39001B Aria of Jaquar ,Hindware Model No F280010 SCP, CeraModel NoF2002461, Asian Paints Cat Part No MMCH101 & Kerovit Cat Part No :- KB1211026. 100 S/F in repairs low density polyethene pipes (LDPE) 32mm of pressure rating 6 Kg/cm2 fixed to walls complete all as specified and directed. 101 S&F in repairs stainles steel Curtain Rod 25 mm dia of approved quality with two number decorative design as approved brackets fixed in brick/concrete wall and same finished knobs on each end of curtain rod all as directed and specified. 102 S & F 500 ltrs capacity rotational moulded polythylene triple layered water storage tanks white in colour (cylindrical vertical with closed top) hoisted and fixed in position incl dismalting of existing tank/ demolition of RCC water storage tank of capacity and any description all as specified in SSR Part Iall as directed and specified. 103 S&F in repairs 15mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms complete all asspecified or as directed. 104 S&F in repairs of 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed all as directed and specified. 105 S&F Mild steel OHT cage, bands, straps, supports or stay, for rain water, ventilating pipes including bolts if reqd, hooks (stay) heavy for large gates hook and pintle large hasps and staple, chains hand made sliding bolts clamps, hold fasts wall ties etc etc hooks for hanging fans plain angle cleats for securing purlins to wood truss or rafter, knee piece inserts, two way and three way straps, plate washer and similar small articles confirming to Fe-290 Gde - E-165 all as directed and specified. 106 Taking up or down AC/PVC rain water pipe, soil/waste/vent pipe of any size with fittings etc. all as directed and specified. 107 S & F PVC (SWR) 110 mm diasoil waste or rainwater drainage pipes single socketed in any length with rubber ring joint laid in floor or fixed on wall all as specified or as directed. 108 S & FPVC (SWR) 110 mmbore bends all as specified or as directed. 109 S&F in repairPVC (SWR) multi floor trap with grating including jointing with solvent cement floor trap 75 mm dia outlet plain including jointing to waste pipe fixed in cement concrete (1:2:4), type B-1 complete all as specified and as directed. 110 S&F in repair PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints fixed to wall and floorwith necessary fitting complete all as specified and as directed. 111 S & F in repairs spun iron soil, waste and vent pipe, 75mm bore, in any length with or without ear with cement joint fixed to walls all as directed and specified. 112 S&F in repairs PVC 100mm bore Y-Junction piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches with oval access doorall as directed and specified. 113 S&F in repairs PVC 100mm bore branch piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches with oval access door all as directed and specified. 114 S&F in repairs PVC 75 mm bore branch piece single (equal or unequal) ordinary or inverted (spigot or shocket type) or with parallel branches with oval access door all as directed and specified. 115 S&F in repairs 100mm bore PVC bends (any radius) diminishing pieces or tapers (larger bore mesured) with oval access door all as directed and specified. 116 S&F in repairs 80mm bore PVC bends (any radius) diminishing pieces or tapers (larger bore mesured) with oval access door all as directed and specified. 117 S&F in repairs 80 mm bore PVC cowl complete all as specified. 118 S&F powder coated aluminium sliding windows frame with movable shutter ( sliding on minimum two PVC roller of best quality) for each shutter on three tracks with stainless steel mosquito proofing and glazing shutter and including 5.50 mm thick glass & stainless steel wire mesh fixed with neoprene rubber gasket with aluminium beading, clips,frame made with aluminium section as appended below-(i) Window frame of minimum size : 92 x38 mm X 1.15 mm thick for three tracks.63 x38 mm X 1.15 mm thick for two tracks. 119 S & Fforstainlesssteel glossy finish hat peg set of five tier with necessary fitting complete all as specified and directed. 120 S&F for mild steel window grills box type framed work as in window guard bars, grills or forged into spikes, framed balusters, walkway railing and similar work including welding, FE-290 grade E-165 complete all as specfied and directed. 121 S&F for Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for 75mm dia pipe, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. 122 S&F for Stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for 100mm dia pipe, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. 123 S&F for computerised reflective letter / bldg number on ACP sheet (size 45mm x 45mm) and fixing with 04 nos of screw, rawal plug etc on wall in front of building complete all as specified and directed. 124 M&L for Machine pressed precast conctete interlocking paver block with gray cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Gradeover 25mm thick sand cushioning including watering and consolidation and dismatling of existing tile complete all specified and directed. 125 M&Lfor PCC kerb stone outer coloured surface machine pressed factory made of size 300 mm long , 300mm wide, 150mm thickusing M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete incl form work weathering, slightly rounded or chamfered angles and throating all as specifed and directed 126 S & F for 150 mm dia reinforced concrete pipes,class NP2, laid and jointed, tested as in sewer line complete with collars incl providing PCC beddingwith 1:3:6Type C1 (using 20 mm graded stone aggregate) including packing under and completely surrounding the pipes after they are laid and tested andcomplete allas specified and as directed. 127 Excavating in trenchs, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in sof/loose soil complete all as specified. 128 Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.Note:- 16 Cum Quantity is for External Electrification. 129 Removing excavated Soil material n exc. 50m and depositing wheredirected at a level n exc. 1.5 m above the starting point complete all as specified and directed.Note:- 08 Cum Quantity is for External Electrification. 130 Internal E/M 131 Taking down carefully unserviceable copper/aluminium point wiring (Light, fan, socket or power) complete including unserviceable fittings and fixtures such as switches, ceiling roses, pendents, regulators, sockets,lamp holders, brackets, except ceiling fittings, bulk head fittings, tube light fittings etc. and making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed. 132 Taking Down old sub main copper/aluminium cable off various sizes from existing conduit/ batten complete all as specified and directed. 133 Taking down old MCB DBs/ main switches off size complete all as specified and directed 134 M&L for wiring with and includingmulti stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including medium grade, rigid non metallic, PVC concealed conduit of 20mm bore and including cutting chases for conduits and sinkings for boxes, its accessories & including with multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number ascontinuity earth wire terminating with new sunken concealed terminal boxescomplete all as specified and directed for the following :- 135 (a)One light/fan/Bellpoint controlled by one switch 136 (b)One 3 pin, 5 Amps, socket outlet on the same board, controlled by another switch. 137 (c)One multi pin socket outlet, 5 Amps, on Independent board. 138 (d) One light point controlled by 2-way switch. 139 M&L for wiring with and includingmulti stranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number, drawing through in and including medium grade, rigid non metallic, PVC concealed conduit of 20mm bore and including cutting chases for conduits and sinkings for boxes, its accessories & including with multi stranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with valid CML number ascontinuity earth wire terminating with new sunken concealed terminal boxescomplete all as specified and directed. 140 S&F, switch piano, flush button, single pole, one way 15 Amps complete all as specified and directed 141 S&F, Socket outlet 15 Amps complete all as specified and directed 142 S&F, switch piano, flush button, single pole, one way, 5 Amps complete all as specified and directed 143 S&F switch piano flush type single pole 2-way 5/6 Amp complete all as specified and directed. 144 S&F, Socket outlet 5 Amps complete all as specified and directed 145 S&F Bell Push, flush type, 5 Amps, Single pole, one way, 230 Volts AC circuit complete all as specified and directed. 146 S&F in repairs Bell (Ding dong,230 Volts AC circuit single pole complete all as specified and directed. 147 M & L in repairs for ceiling fan regulators, Electronic steped type, AC, 230 Voltscomplete all as specified and directed. 148 S&F, in repairs ceiling rose, 3 terminal , any shade, of PVC/Polycarbonate, isolated body complete all as specified and directed 149 S & F of following factory made V TPN DBs-DPX-160 MCCB DBs, IP-43 protection-IK09 with metal door with 160 Amps copper busbar with 2 neutral busbar, earth bar cables ties for cable management fully insulated busbar with set of wires and door earthing for provision of DPX 160 MCCB and incomer and SP/TP MCBs as outgoing 4 way etccomplete all as specified and directed. 150 S&F in repairs MCCB 63 Amp,415 volts, 4 pole, Thermal magnetic release for line protection etc complete all as specified and directed. 151 S&F sheet metal distribution board, SPN, 8 way 240 Volt, single door factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 A tinned copper bus bar complete all as specified and directed. 152 S&F, in repairs, miniature circuit breakers, type curve‘B’ , 10 KA, SP, 6 to 32 Amps complete all as specified and directed. 153 S&F, in repair, miniature circuit breakers, SPN, type curve‘C’ 10KA, 32 Amps, 240 Volts.complete all as specified and directed. 154 S&F, in repairs, LED light fitting, high lumens batten type, housed in extruded from powder coated aluminium, 20 watt for soft diffuser lighting with and including lamp and connecting up complete with white PVC insulated and PVC sheathed round flexible three core copper conductor cable of suitable size complete 155 S&F, in repairs, LED light fitting, high lumens batten type, housed in extruded from powder coated aluminium, 10 watt for soft diffuser lighting with and including lamp and connecting up complete with white PVC insulated and PVC sheathed round flexible three core copper conductor cable of suitable size complete all as specified and directed. 156 S & F of 1100 volts grade heavy duty two single core 4 Sqmm size (Nominal Area) PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC conduit medium grade not less than 25 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of 4 Sqmm size (Nominal size) stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. NOTE: - TWO SINGLE CORE CABLES ALONG WITH EARTH WIRE AND PVC CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH. 157 S&F in repairs LED Bldg Street light fitting 35 - 36W, IP 65 made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP65 protection, roadway luminaire with high powerLED as light source 1 x 35/36 Watt, LED 6000K, complete with all accessories internally pre-wired complete all as specified and as directed. 158 S&F in repairs Street Light bracket made oflight grade GI pipe 32 mm bore and 1.20 mtr long duly bent to shape including2 Pairs of MS Clamps made out of 40mm x 3mm M.S. flat, nuts, bolts, washers etc complete all as specified and as directed. 159 M&L in repairs for earthing and testing complete with galvanized iron earth plate electrode 60 cm x 60cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 M below normal ground level with top edge plate at adepth not less than 1.5M below normal ground level connected to and including earth lead GI wire 4 mm dia, by means of bolts and nuts,check nuts and washers etc.,made of GI and connected to panel/distribution board and earthing test point and earth dolly all as shown in elect plate No.3 of SSR Part-1 including necessary earth work,excavation PCC chamber cover with handle (PCC 1:2:4) incl 20mm dia GI pipe ofmedium grade for watering and15mm dia GI pipe of light grade for protection of earthing lead ,wiremesh, funnel, charcoal dust,common salt,copper lugs etc complete all as specified and as directed. 160 Taking down Ceiling Fan of any size and place in safe custody by the contractorcomplete all as specified . 161 Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified . 162 Rewinding of ceiling fan with copper wire incl replacemement of bearing ,greasing and painting with white paint complete all as specified . 163 Supply and fix Exhaust FanMetal Body AC single phase 230/240V of size 300 sweep with louver complete all as specified . 164 M & L for Hole cutting in wall for fixing of exhaust fan of size 300 mm and good the disturbed surfacres of wallby using putty and match with existing colour of wall complete all as specified and directed.Note:Cost of repairing work and material ( cement and sand) included in quoted rate. complete all as specified . 165 M&L for Angle Holder, insulated body with back plate with & including LED Lamp 7 Watt suitable for batten fittings complete all as specified . 166 Supply and fix Water heater storage type, electric, capacity 25 litres.BEE 5 star rated complete all as specified . 167 S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified . 168 External E/M 169 Taking down carefully serviceconnections of any description from pole, wallor service brackets etc including making good disturbed surface to match with the existing surface complete all as specified. 170 Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm, 3.5 core. complete all as specified . 171 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/dence soil for laying of LT UG cables/base for Poleetc complete. 172 M&L for sand cushioning laid in trenches for laying of LT UG cables complete complete all as specified . 173 M&L Modular bricks common burnt clay building bricks, sub-class ‘B’ designation-75 for LT UG cable protectioncomplete all as spd and directed. 174 S&F GI tubes light grade of dia 80 mm with all fitting and fixed complete for protection of LT UG Cables laidto walls or in floors or along with poles etc complete all asspd and directed. 175 Notes:-Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.