| 1 | Taking down carefully existing copper/Aluminum point wiring (light,fan, socket or power) complete including fixture and fittings such as switches, bellpushes, ceiling roses, pendents, regulators, sockets, light fitting, callbells etc removiing materials to store for keeping in safe custody or for taking credit(credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. to match existing complete allas specified and directed |
| 2 | M & L forPoint wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor to common earth and connected to earth dolly, GI terminal boxes, modular frame & cover plate (suitable for modular switch/sockets) comprising the following: - |
| 3 | One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified. |
| 4 | One Socket outlet three pin, 6 Amp, on the same board, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified |
| 5 | One Socket outlet three pin, 6 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor,in existing concealed conduit all as specified. |
| 6 | One Bell/Buzzer point controlled by one push button with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor,in existing concealed conduit all as specified. |
| 7 | One light point controlled by two two way switch. with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in existing concealed conduit all as specified. |
| 8 | One socket outlet three pin, 5/15 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor,in existing concealed conduit all as specified. |
| 9 | M & L for inverterwiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed cable,one light point /one5 Ampsocket pointonly.including drawn thoughPVC conductall as specified and as directed by Engr in charge. |
| 10 | S&F Switch modular type single pole, one way, 6 Amp, one module, complete all as specified. |
| 11 | S&F Switch modular type single pole one way, 16 Amp,one module, complete all as specified. |
| 12 | S&F Switch modular type single pole, two way, 6 Amp, one module, complete all as specified. |
| 13 | S&F Bell push switch modular type single pole one way, 6 Amp, one module, complete all as specified. |
| 14 | S&F Socket outlet modular type, multipurpose, 3 pin, single pole one way, 6 Amp,two module, shutter type complete all as specified. |
| 15 | S&F Socket outlet modular type multipurpose 3 pin, 2 in 1 single pole one way 6/16 Amp, two module, shutter typecomplete all as specified |
| 16 | S&F in repair Modular telephone socket one module complete. |
| 17 | S&F Fan regulator, modular type, 5 step, high speed, two module complete all as specified. |
| 18 | S&F in repair Switch piano, flush type single pole, one way 5 Amp complete all as specified |
| 19 | S&F in repair Switch piano, flush type single pole, two way 5 Amp complete all as |
| 20 | S&F in repair Switch piano, flush type single pole, one way 15 Amp complete all as specified |
| 21 | S&F in repair Bell push 5/6 Amps 230 V AC complete all as specified |
| 22 | S&F in repair Socket outlet 3 pin, 5A, flush type all as specified |
| 23 | S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified |
| 24 | S&F in repair Socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified |
| 25 | S&F in repair Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified |
| 26 | S&F Ceiling rose, 3 terminal PVC/polycarbonate, suitable for 230 V, AC, 50 Hz supply. |
| 27 | S&F call bell ding dong type AC 230 V complete.( Make Anchor/ SSK/Cona) |
| 28 | Supply and Fixing onlywall mounted extruded Aluminium/polycarbonate integrated LED batten fixture with tube 1.2 m, 20watt, 1.2 m3000/6500K,efficacy not less than 90 lumen/watt worm white, extruded Aluminium/polycarbonate, PC diffusor and integrated inbuilt driver completecomplete including making connection complete all as specified and directed. |
| 29 | Supply and Fixing only decorative wall light fixture made of polycarbonate suitable for retrofit 9W LED lamp(base B-22) complete with PC diffusor & including one 9W LED lamp(base B-22), 3000/6500K, not less than 90 lumen/watt efficacy including making connection complete all as specified and directed. |
| 30 | Supply and Fixing onlyintegrated round shape 12/18watt 220V AC surface type 3000/6500K,efficacy not less than 90 lumen/watt with high efficiency PMMA diffusor soft glare free light complete and integrated inbuilt driver, holders, LED lamps etc including making connection complete all specified and directed) |
| 31 | S&F LED light fitting 9/10W bulkhead luminaires incluing LED light, driver, holder connecting up with three core flexible copper conductor cable of suitable size complete allas specified and directed |
| 32 | S&F Lamp holder PVC/polycarbonate type with back plate complete all as specified |
| 33 | S&F post top lantern LED type 20 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistance complete with driver and lamp complete all as specified and directed |
| 34 | S&F LEDdownlighter/spot light fitting, recessed mounted, round shaped of ceiling cut outφ160mm, 12watts efficacy not less than 90 lumen/watt, 3000/6500K extruded Aluminium/polycarbonate, PC diffusor, module and inbuilt driver complete including making connection complete all as specified and directed. |
| 35 | S&F LEDlandscape/bollard light fitting, round shaped of 0.6m pole size, 10watts, efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, IP65, PC diffusor, module and inbuilt driver complete including making connection & fixing of pole base with nut and bolt to PCC pedestal/coping complete all as specified and directed.. |
| 36 | S&F in repair LED AC Rope 60 LED/M 6500K/4000K IP65, waterproof, with reflector, multicolor complete C ROPE 60 LED/M Light Accessories complete all as specified and directed. |
| 37 | S&F LED string light with white/ warm white colour with minimum 50 LED/ Mlamps and length 20 mtrs long out door type6500K/4000K IP65, waterproof, with reflector,completewith all Accessories complete all as specified and directed |
| 38 | S&F in replacement sub main two single core PVC copper conductor unsheathed wiremulti stranded 4 sqmm along with earth wire 4.0 sqmm copper conductor single core wire connected by common earth inexisting surface/recessed PVC/steel conduit complete all as specified.(Note :- two lengths of 4.0 sqmm cable and one length of 4.0 sqmm earth cablewill be measured as one running length) |
| 39 | S&F in replacement sub main two single core PVC copper conductor unsheathed wiremulti stranded 6 sqmm along with earth wire 6.0 sqmm copper conductor single core wire connected by common earth inexisting surface/recessed PVC/steel conduit complete all as specified.(Note :- two lengths of 6.0 sqmm cable and one length of 6.0 sqmm earth cablewill be measured as one running length) |
| 40 | S&F in replacement sub main two single core PVC copper conductor unsheathed wiremulti stranded 10 sqmm along with earth wire 10.0 sqmm copper conductor single core wire connected by common earth inexisting surface/recessed PVC/steel conduit complete all as specified.(Note :- two lengths of 10.0 sqmm cable and one length of 10.0 sqmm earth cablewill be measured as one running length) |
| 41 | S&F in replacement sub main four single core PVC copper conductor unsheathed wire multi stranded 10 sqmm along with earth wire 10.0 sqmm copper conductor single core wire connected by common earth inexisting surface/recessed PVC/steel conduit complete all as specified.(Note :- four lengths of 10.0 sqmm cable and one length of 10.0 sqmm earth cablewill be measured as one running length) |
| 42 | S&F in replacement sheet metal encloser double door 4 way TPN 415V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed |
| 43 | S&F in replacement sheet metal encloser double door 12 way SPN 240V ISI marked complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed |
| 44 | S&F in replacement single pole and neutral enclosure 240V with a two pin and earth plug and socket complete with one double pole MCB 20Amp complete all as specified and direcetd |
| 45 | S&F in repair MCB 6-32 Amp 240V SP 10 KA ‘B’ series complete all as specified |
| 46 | S&F in repair MCB 40-63 Amp 240V SPN 10 KA ‘C’ seriescomplete all as specified |
| 47 | S&F in repair MCB 415V 40 to 100Amp TPN 10 KA ‘C’ seriescomplete all as specified |
| 48 | S&F in repair MCCB 415V, FP 100 to 125A 16kA complete all as specified |
| 49 | M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burriedin ground vertically to earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick eachconnected to and including GI earth wire 4 mm dia by means of nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate to distribution board and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates)for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I andtesting on completion including replacement of old unserviceable.Note:- It is mandatory to paint a sqaure shape notice board of yellow color with legible black color letters of earthing mentioned details as below; Cost incurred deemed to be inlcuded in quoted rate:- |
| 50 | S&F in repair rigid non metallic PVC conduit medium grade 20 mm nominal dia,\"ISI marked\" inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddles, pipe hooks etc for telephone socket, complete all as specified. (MAKE FINOLEX/polycab/supreme) |
| 51 | S&F in repair Hylam sheet cover 3mm thick of size 8\"X5\" to 13\"x8\" complete with machine screw/ washer with provision of slots for switches, sockets, fan regulators (including refixing of all switches, sockets, fan regulators dismentaled from existing sheets) complete all as specified |
| 52 | Supplying and fixing in replacement 1100volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 6sqmm complete all as specified |
| 53 | S&F LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 protection including fixing with suitable bolt and nuts complete with making connection complete all as specified and directed. |
| 54 | Dismentaling & taking down of existing single phase energy meter andSupply and fixing New electronic meter temper proof LCD display with polycarbonate cover 10-60 Amp, accuracy class 1.0 50 Hz, confirm to IS 13779 IP 54with parameter to show data , time, current reading, load,pf voltage and KWH complete all as specified and directed. |
| 55 | Dismentaling & taking down of existing threephase 4 wireenergy meter andSupply and fixing New electronic meter temper proof LCD display with polycarbonate cover 10-60 Amp, accuracy class 1.0 50 Hz, confirm to IS 13779 IP 54with parameter to show data , time, current reading, load,pf voltage and KWH complete all as specified and directed. |
| 56 | Checking of non functional point wiring such as light point, fan, socket 5/15A independent board, same board, power point, switches 5/15A, sockets 5/15A, switch board, Call Bell, bell push, MCBs, DBs etc and find out faults at site and making proper functional and repairing to cable connection/ loose connection and refixing by replacing by new screws etc and testing complete all as specified and directedNote:- (i) Necessary T&P required at site will be provided by the contractor and cost of T&P deemed to be included in the quoted rates. |
| 57 | Taking down and Hanging onlyCeiling fan 1200/1400 connecting up including provision ofcable from ceiling rose or connecting to fan etc |
| 58 | S&F wall mounted bed side light LED 6 waats adjutable operated on 230 volts 50 Hzcomplete including making connection & all as specified and directed.((Make crompton/ suriya/ bajaj/hevvalls or equivilent) |