Purchase Of Sports Exercise Physiology Lap Equipments , Cardiopulmonary Exercise Testing System • System Should Be Compact Can Be Used In Laboratory Operation And Low Maintenance Costs And Easy Servicing. • System Should Be State Of The Art Computerized Telemetry Breath Test Analyzer For On-Line Breath By Breath Measurement Of Exercise Test Of Respiratory System To Measure Following Parameter: Time, Ve, Bf(Rr), Hr, Feo2, Feco2, Peo2, Peco2, Vo2, Vco2, Ve/Vco2(Eqco2), Ve/Vo2(Eqo2), Rq(Rer), Vd/Vt, Vo2/Kg, Vo2/Kg/Hr, Met, Watt(Work), Hr, Ttot, Ti, Te, Ti/Te, Ti/Ttot, Pef, Pif, Br, Vet, Sum, Tv/Te, O2 Kinetics, Oxygen Deficit, Oxygen Debt Parameters And Indirect Calorimetric. Wireless Hr Recording System, Indirect Cardiac Output By “Wassermann Algorithm” • System Should Comply Ats And Ers Guide Line And It Should Be Ce Certified., Iso Certified • System Should Have Automatic Ambient Conditions Measuring System. • System Should Work Under Temperature Range 0 To 50” Celsius. •System Should Have Facility For Automatic Calibration Of Analyzers. Volume Transducer Calibration With Precision Calibration Syringe. • System Should Meet Following Technical Specification Flow Rate Measurement: Measuring Headpiece Should Be Either Through Turbine /Dvt/ Pneumotach And Dead Space Less Then 40 Ml, It Should Not Be Affected By Humidity , Flow Range +/- 18 L/S And Accuracy < 2% Oxygen Analyser :Should Be Either Electrochemical Cell/Paramagnetic And Measurement Range 0- 100 %, Response Time T90 < 100 Ms And Accuracy +/-0,04 % And - Resolution 0,02 % Carbon Dioxide Analyser : Should Be Ndir (Infrared Absorption) And Measurement Range 0 - 10 %,- Response Time T90 < 90 Ms , Accuracy +/- 0,04 %, And Resolution 0,02 % • Software Should Support Latest Windows Or Latest And In Corporate Customized Predicted Normal Equations. Software Should Be Capable Of Changing Graphics Displays During Real Time Testing. • System Should Have Facility For Automatic Treadmill Or Bicycle Ergo Meter Control. • Should Be Supplied With Software, Standard Accessories For Operation Manual Carrying Case For Field Use. • System Should Be Supplied With Latest Data Acquisition System, Deskjet Printer And Ups. • System Should Comply En Iso 13485:2003, En Iso 9001:2000, Ec Certificate93/42/Eec , Programmable Treadmill • Running Machine With User Terminal (Display &Keyboard) Stand- Alone And Remote Control Via Rs232 • Running Surface: L:170 Cm (Minimum), W: 65 Cm (Minimum) • Maximum Possible Load: 200 Kg (440 Lbs) • Speed Range: 0-40 Km/H • Elevation: ±25% (14° Maximum Elevation) Motorized Adjustment, Reverse Belt Rotation. • Motor System 3.3 Kw, Single Phase Ac Motor, Maintenance Free And Brushless • Power Transmission: Frequency Inverter, Poly V- Belt, Very Quiet Operation • Safety System: Emergency-Off Safety Stop Switch (Safety Lanyard With Actuator, Pull Cord And Clip); Potential Equalization Bolt; Transformer For Potential-Isolation From The Mains • Ambient Condition: Temperature: +10To +40 Degrees C, Humidity 30 To 70% • Display (Resolution): Lcd Display • Heartrate Monitoring: Wireless Transmitter; The Treadmill Should Be Able To Interface With Well-Known Compatible Metabolic Gas Analyzer As Per Standard And Custom Exercise Protocols • Different Programs Safety Harness- 1. Indispensable Accessory For Stress Testing, Accident Prevention And For The General Safety Of Athletes. 2. Safety Arch With Different Heights And Widths To Fit All Running Machines. 3. An Emergency Stop At The Crossbar Of The Safety Arch Allows Automatic Stop Of The Running Belt In The Moment A Fall Occurs. 4. The Harness And Chest Belt (Available In 5 Sizes: Xxs, S, M, L, Xl) Secure The Subject And Prevents Falling Over To The Front. 5. Chest Belt Straps Do Not Pinch Or Restrict The Athlete , Programmable Ergometer • Functional Design And Excellent Stability, Load Up To 160Kg. • Easy To Use Saddle, Handle Bar And Pedals • Speed Independent And Dependent Power Control • Handle Bars Are Easy To Change To Suit Different Tests, Rotatable By 360 Degrees. • Mechanical/Motor-Assisted Seat Adjustment • Easy To Control And Calibrate. • Can Be Controlled By Two External Devices (Rs232or Usb). • Ble Smart And Ant+ Hr Systems. • Work Load Range6-1000W. • Universal Interface For Ecg System/Pc Based Ecg Units • Multiple User Programmable Exercise Test Protocol , Anaerobic Ergometer (Upper Body) • Suitable For Anaerobic Upper Body Test (Wingate Option). • Adjustable Standard Chair For Optimal Positioning • Easy To Start With Lighter Fly Wheel. • The Weight Basket Is Released By A Pushbutton Mounted On The Cover. • Work Load Range 50 Watt-2400 Watt. • 5 Khz Hr System In Display. • Should Be Already Calibrated With Correct Weights • Weight Basket (1Kg) System Must Have 4Pcs 0.1Kg, 1Pcs 0.5 Kg, 3Pcs 1Kg. • Must Include-Chest Belt, Pc, Anaerobic Test Software, User License, Ups, Power Adapter, Printer, Hdmi Cable. • Connectivity Through Rs232. International Safety Standards European Ce/Usfd Approved. , Anaerobic Ergometer (Lower Body) • An Ergometer For Anaerobic Tests (Wingate Test) For Lower Body With Unique Anaerobic Test Software • Computer Laptop With Accessories Like Ups, Printer Of Suitable Configuration Should Be Provided By The Supplier. • Multiple Bouts With Fatigue Index • High Sampling Frequency (50 Hz) • Weight Basket (1 Kg), The Fastest Way From “0” To Full Power • Start From 0 Rpm With Accurate Power • Extra Rigid Frame • Calibrated With Correct Weights • 5 Khz Hr System For Display • Pc Connectivity Withrs232 • Work Load Range: 50-2400 W • Weight Basket System (0.1Kg 4 Pc, 0.5 Kg-1 Pc, 1 Kg- 8 Pc Weights) For Accurate Workload. • Extra Wide Floor Stands, Prepared For Fixed Installations. • Adjustable Seat Post • Handlebar With Basket Release Button • Resistance: A) System: Weight Basket, B) Flywheel • Electronic Meter Shows Pedal Turns Per Minute (Rpm)- Heart Rate In Beats Per Minute (Hr)- Cycling Time In Minutes And Seconds (Time)- Intended Cycling Speed In Km/ Miles Per Hour (Speed)- Plus Distance Covered In Miles (Distance). • International Safety Standards. European Ce/ Us Fda Approved. , Wearable Physiological Monitoring System (30 Sensors) • Should Be Able To Work In Lab And Field Studies (Portable And Easy To Carry). • The System Should Be Able To Record The Below Parameters Wirelessly (2 Ecg Signals, Acceleration -3Axis, Respiration, Skin Temperature, Gsr, Spo2, Ppg) • Should Have High Adc Resolution • The System Should Provide Real Time Data Recording With Online And Offline Analysis • Should Have At Least 8 Hours Of Operation In Full Transmission Mode. • Option For External Battery Pack. • Automatic Heartrate Variability Analysis. • Online And Offline From Human Subjects. • Online And Offline Ecg Analysis For All Ecg Intervals, Plots Etc. • Telemetric Transmission Should Be Minimum100 Meter Not Less Than That. • Should Provide Frequency And Time Domain Hrv Analysis With Automatic Plots Generation Like Tachogram Plot, Rr, Histogram Plot, Delta Rr, Histogram Plot, Poincare Plot, Power Spectrum Plot Etc. • The Software For Recording The Data And Analysis The Data Should Be Same. • Four Force Sensor Balance Board For Body Sway Analysis That Communicate With The Same Software Via Bluetooth For Analysis And Recording. • Both Wireless System And Force Sensor Balance Board Should Work On Same Software Simultaneously And Independently For Recording And Analysis As Per User Demand. • Should Have Software-Controlled Filtering High Pass, Low Pass Filters, Ac Coupling, Digital Filters, Band Pass Filter And Main Filters. • Display Modes: Must Have Simple Chart View, Scope View, Xy View, Zoom View, Fft, Spectrum, Averaging View Etc. • The Software Should Have Built In Smart Analysis Features Like Power Spectrum, Template Matching, Curve Fitting, Cross Correlation Etc. • Facility To Perform Complete Heartrate Variability Analysis (Time And Frequency Domains) Online And Offline, Ecg Interpretation, Pqrst Amplitudes And St Elevation, Cardiac Axis Analysis During Exercise. •Cyclic Measurement: Rate Period, Frequency, Count, Minimum, Maximum, Height, Integral, Variance, Derivatives, Arithmetic And Mathematic Formulae • Iso And European Iec Certificates To Be Provided , Spirometer (With Mip And Mep Testing Facility) • Should Include Validated Bidirectional Digital Turbine Flowmeter Or Pneumotachograph With Max Flow Range Of = 16L/S • Should Be Provided With Suitable Software For Data Management, Real Time Assessment And Accurate Interpretation • The System Should Have Autonomy Of Min 5 Hours. •Must Include Rechargeable Batteries, Battery Charger, Adapters, Thermal Papers (If Required), Usb Cable, User Manual, Single Use Mouthpieces (200Pc), Single Use Nosepieces (25Pc), Thermal Printer Rolls [10Pc (If Required)], Compatible Desktop/Laptop, A Colored Multi-Function Printer • The Compatible Desktop/ Laptop Must Meet The Specifications As Under Windows 10 (32 Bit And/Or 64Bit), Min 2Ghz Cpu With Ram More Than 4Gb, More Than 500Gb Hdd And 4 Usb Ports, A Full Hd Display Monitor, Ups, Keyboard, Mouse • The Lung Function Tests Must Include Fvc Pre/Post, Svc Pre/Post, Mvv, Spo2 (Optional: Mip/Mep) • Interface Options: Usb/ Rs232/Bluetooth • Colored Display •Safety And Quality Control In Compliance With International Guidelines (I.E. Ats, Ers) , Handgrip Dynamometer • Measuring Range Up To 100 Kg • Minimum Measuring Unit: 0.1Kg • Accuracy: ±0.1Kg • Display: Lcd In 3 Digits • Items Displayed: Each Value And The Average • Automatic Stop Approx. 1Minute After The Final Measurement Dry Battery With A Life Of Approx. 100 Hrs. Service, Temperature Range: 5 To 35 Degree C , Back Dynamometer • Measuring Range Up To 300 Kg • Minimum Measuring Unit: 0.5Kg • Accuracy: ±0.5Kg • Display: Lcd In 4 Digits • Displayed: Each Value And The Average • Automatic Stop Approx.1 Minute After The Final Measurement, Dry Battery And Life Of Each Cell Approx.100 Hrs Service, Temperature Range: 5 To 35 Degree C , Sit And Reach Box • Rust Proof Long Lasting Metal • Box With Adjustable Height Will Be Preferred • Scale Marked In Centimeters • With Maximum Stretching Indicator Slide Portable , Blood Pressure Monitor (Digital) (As Per The Requirement) Display And Measurement Features - Display Type: Lcd Digital Display For Clear And Easy Reading - Measurement Range: Typically Measures Blood Pressure And Pulse Rate With Accuracy - Cuff Size: Universal Cuff Size, Usually Fitting Arm Circumferences Between 22-32 Cm Accuracy And Reliability - Accuracy: Clinically Validated For Accuracy, With Some Models Featuring Intelli Wrap 360° Accuracy For Precise Readings Regardless Of Cuff Positioning. - Intellisense Technology: Provides Comfortable And Controlled Inflation For Accurate Measurements, Memory And Data Storage. - Memory Storage: Stores Multiple Readings, Typically Up To 60 Or 99 Measurements, With Date And Time Stamps For Tracking Progress. - User Profiles: Some Models Allow For Multiple User Profiles, Making It Easy To Track Readings For Different Individuals. Preference Will Be Given To Product With Below Mentioned Additional Features - Body Movement Detection: Alerts Users To Potential Inaccuracies Due To Movement During Measurement - Irregular Heartbeat Detection: Notifies Users Of Potential Irregular Heart Rhythms - Hypertension Indicator: Flags Readings That May Indicate High Blood Pressure - Average Readings: Calculates Average Readings Over A Set Period, Such As The Last 3 Readings Within 10 Minutes Power And Portability - Power Source: Often Powered By Batteries (E.G., 4 X Aa Alkaline Batteries) Or Usb Rechargeable - Portability: Compact And Lightweight Design For Easy Use At Home Or On-The-Go , Portable Lactate Analyzer With 200 Strips • The Analyzer Should Be A Compact One With Digital Lcd Display Of Parameters. • Portable, Light Weight, Battery Operated. • Can Measure Lactate From Whole Blood With Minimal Sample • Processing Speed: = 15 Secs • Calibration: Automatic/ Calibrated By Simple Coding • At Least 100 Nos. Test Strips Should Be Supplied With The Unit • Measurement Condition: 5°- 40° C Temperature, Max 85% Humidity • Measuring Range: 0-25Mmol/L • Memory Capacity: >300 Samples • Provision To Inter Phase The Data With Data Acquisition System Through Usb Cable And Results Should Be Viewed In The Supplied Data Management Software. , Pulse Oximeter (As Per The Requirement) Fingertip Pulse Oximeter; Certification - Approved By Fda • Pulse Rate Range - 20 To 300 Bpm; Oxygen Saturation Range 0 - 99% To100% Spo2. • Wavelength Of Led - 660 660 Red Light; 940 940 Infrared Light. Pulse Oximeter With Alarm Is Durable And Efficient To Withstand Years Of Use. , Field Test Accessories (Cones, Measuring Tapes- 50 Meters, Bluetooth Speakers, Stopwatches, Optical Hr Sensors) As Per Requirement , Digital Bmi Machine • Capacity: 660 Lbs / 300 Kg, Gradation: 50G/0.1Lbs. • Measuring Range: 30-220 Cm, Gradation:1Mm/ 0.05Inch. • Power Supply: Battery, Power Adapter. • Frankfurt Line For Precise Position Of Head. • Three-Line Multi-Function Touch Display Shows Weight, Height And Automatically Calculated Bmi. , Sitting Height Table • Measuring Range:320Mm To1090 Mm. • Anti-Reverse Carriage Lock To Compensate For Upper Leg Variation And Adjustable Foot Rest. , Multi-Frequency Body Composition Analyzer Tetra-Polar Electrode Method Using 8 Touch Electrodes • Smf-Bia Technology, 15 Impedance Measurements Using 3 Different Frequencies. • Must Be Equipped With Data Storage Facility. • Touch Screen Color Lcd Screen Display. • Voice Guidance For Test. • Measuring Time:20 Secs • Measuring Weight Maximum: 250 Kg • Maximum Height Measurement: 220 Cm • Measuring Sites: Whole Body Composition And Segmental Composition (Arms, Legs And Truck) • Software: Latest Operating System With Compatible And Upgradable Software. • External Interface Via.Rs232/Usb/Bluetoothwi-Fi • Compatible Printer/Inbuilt Thermal Printer Must Be Supplied. • Must Show High Correlation With Dexa Security Access Code. , Anthropometry Kit Includes • Large Bone Anthropometer (60Cm) • Small Bone Anthropometer (18Cm) • Flexible Ergometer(3M) • Anthropometric Measuring Tape(2M) • Portable Stadiometer (3M). • Padded Transport Case , Electronic Weighing Machine • Digital Display. • Capacity:1Kg-200Kg • Accuracy: 50Gc , Arm Span Measurement Apparatus • Material: Light Weight Wood • Free Sliding Extensor For Easy Measure. • Range:0–3000 Mm (1Mm Graduation) • Easy To Assembly: 4 Screws And 4 Dowel Pins Including A Case • Weight: 3.0Kg • Dimensions:324X8.55X12cm , Skinfold Caliper (As Per The Requirement) Measuring Range- : 0 Inches – 1.81Inches In Measuring Range-:0Mm-46 Mm Constant Pressure Between Anvils:10 Grams/Sq. Mm Dial Graduation: 0.08 In / 0.2 Mm Weight In Wallet:1.1Lbs/0.5 Kg , Anthropometer (As Per The Requirement) Measuring Range - Inches (0 In - 82.68 Inch) Measuring Range – Millimetres (0 Mm To 2100 Mm ) Weight: 2 Kg / 0.95 Lbs. , Automated External Defibrillator (Aed): Key Features - User-Friendly Interface: Simple And Intuitive Interface For Easy Operation By Non-Medical Personnel - Voice Prompts: Voice Prompts And Visual Instructions To Guide Users Through The Rescue Process - Automated Analysis: Automated Analysis Of The Patients Heart Rhythm To Determine If A Shock Is Needed - Shock Delivery: Delivery Of A Life-Saving Shock To Restore A Normal Heart Rhythm Performance Specifications - Shock Energy: [Insert Shock Energy, Typically 150-200 Joules] - Waveform: [Insert Waveform, Typically Biphasic Or Monophasic] - Analysis Time: [Insert Analysis Time, Typically <10 Seconds] - Shock Delivery Time: [Insert Shock Delivery Time, Typically <30 Seconds] Safety Features - Safety Checks: Automatic Safety Checks To Ensure The Device Is Functioning Properly - Cpr Guidance: Guidance On Cpr Techniques And Timing To Ensure Optimal Care - Battery Backup: Battery Backup To Ensure Device Functionality In Emergency Situations Additional Features - Data Storage: Optional Data Storage Capabilities To Track Patient Information And Device Usage - Connectivity: Optional Connectivity Options For Data Transfer And Device Integration - Durability: Durable Design To Withstand Harsh Environments. , Ecg Machine Display And User Interface - Display Size: 3.5-Inch To 8-Inch Lcd Or Tft Display, With Touch Screen Functionality For Ease Of Use - Resolution: High-Resolution Display For Clear Waveform Visualization Ecg Acquisition And Analysis - Number Of Leads: Minimum 12-Lead Ecg Machines, With Simultaneous Acquisition And Display - Sampling Rate: 500-32,000 Hz, Affecting The Accuracy And Detail Of Ecg Readings - Ecg Analysis Program: Advanced Algorithms For Accurate Interpretation, Such As Glasgow Or Marquette 12Sl Connectivity And Storage - Wireless Connectivity: Bluetooth Or Wi-Fi For Seamless Data Transfer To Pcs Or Mobile Devices - Internal Storage: 10,000 Ecg Storage Capacity, Depending On The Model - External Storage: Usb Or Sd Card Slots For Expanded Storage Options Printing And Reporting - Built-In Printer: Thermal Printing System For High-Quality Ecg Tracings - Paper Speed: Adjustable Paper Speed, Typically 25Mm/S Or 50Mm/S - Report Formats: Multiple Report Formats, Including Pdf And Customizable Options Power And Portability - Battery Life: 3-10 Hours Of Continuous Use, With Rechargeable Lithium-Ion - Weight: Portable Designs Weighing 1-5 Kg, Ideal For Clinical Or Home Use Additional Features - Pacemaker Detection: Built-In Pacemaker Detection And Analysis Capabilities - Arrhythmia Detection: Advanced Algorithms For Detecting Arrhythmias And Other Cardiac Conditions - Hook-Up Advisor: Guidance On Electrode Placement For Optimal Signal , Smart/Electronic Stethoscope (As Per The Requirement) Key Features - Digital Auscultation: Amplifies Heart And Lung Sounds Up To 40-60 Times, With Active Noise Cancellation And Multiple Audio Filters (E.G., Diaphragm, Bell, And Extended Modes) - Ecg Capabilities: Single-Lead Or 3-Lead Ecg, With Real-Time Analysis And Visualization Of Heart Rhythm And Morphology - Wireless Connectivity: Bluetooth 4.0 Or Higher For Seamless Data Transfer To Smartphones Or Tablets - Data Storage: Ability To Save Recordings For Future Reference And Share With Healthcare Professionals Technical Specifications - Frequency Response: 20 Hz To 2 Khz For Heart And Lung Sounds - Sampling Rate: 4000 Hz For Sound Recordings And 500 Hz For Ecg Signals - Resolution: 16-Bit Or 12-Bit Resolution For Sound And Ecg Signals - Power: Rechargeable Lithium-Ion Battery With Wireless Charging Capabilities Additional Features - Murmur Detection: Ai-Powered Algorithms For Detecting Heart Murmurs And Other Abnormal Sounds - Atrial Fibrillation Detection: Automatic Detection Of Atrial Fibrillation And Other Arrhythmias - Telehealth Capabilities: Secure Live Streaming For Remote Consultations And Virtual Exams - Hipaa Compliance: Ensures Secure Data Transfer And Storage Of Patient Information , Muscle Oximeter System Should Measure Smo2 (Muscle Saturation And Th.B. (Total Haemoglobin) In The Capillaries And Tissue Of Muscle • System Is Capable To Measure Up To 0.5(12Mm) Of Skin And Fat. •System Sensor Can Be Programmed To Measure Every 2 Seconds Or 0.5 Seconds With Smoothing Of Seconds Or None. • System Sensor Should Function In Different Temperature Range With Use Of Light Shield • System Sensor Should Function During All Types Of Vigorous Exercise And Should Have Water And Sweat Resistant. • System Hardware Should Have Physical Dimension Of Sensor 2.4 X 2.0 X0.6 In (No Light Shield ) 5.0 X 4.5 X 1.2 In (With Light Shield) 62 X52 X 15 Mm (No Light Shield ) 128X115x30 Mm (With Light Shield ) And Weight Of Sensor 1.2 Oz (48 G) (No Light Shield ) 2.1 Oz (59 G) (With Light Shield) • System Sensor Should Have Rechargeable Lithium Polymer Battery. System Sensor Should Have 10.000 Data Points Or Over 5 Hours In Default Update Rate. • System Sensor Should Be Compatible With Several Data Display And Collection Software That Are Used For Training Studio And Research Applications. • System Software: It Should Supports Multiple Sensors Per User And Multiple Users. It Can The Data Using Multiple Ant+ Dongles And/Or Multiple Npe Wasp Devices. It Allows Viewing Of The Muscle Oxygen Data And Has An Automated Muscle Oxygen Report That Is Generated At The End Of A Workout. It Should Be Compatible With Most Smart Trainers, Concept Ll Rowers And Some Treadmills. • Standards Used. En 301 489-17 V3.1.1:2017 Bluetooth Low Energy Radio , En 303 417 V1.1.1:2017 Wireless Power Transmission (Wpt) Radio , Draft En 301 489-3 V2.1.1:2017 Wireless Power Transmission (Wpt) Radio , En 55032:2012/Ac:2013 Class B ,En 61000-3-2;2014 En 61000-3-3;2016