Tender For Completion Of Incomplete Work For Provn Of Otm Accommodation (Ph-I Of Two Phs) At Panagarh Mil Stn Under Ge (P) Panagarh.; 1 Sch A Part -I (Building Works)Note:- This Sch is notpre-priced by MES and the pre-priced rate indicatedas Rs 0.00 under Col 5 signifies this fact only. 2 Completion of incomplete Building for signal unit with all fitting and fixtures etc. Complete all as specified and as shown on complete drawings. 3 Completion of incompleteBuilding for office accn/ Adm block with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 4 Completion of incomplete Building for JCO Mess and single living JCO accn with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 5 Completion of incomplete Buildingfor single living ORs accn / Dinning and cook house with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 6 Completion of incomplete Building for Storage Accn (Armouries)& Guard House alongwith hardstanding with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 7 Completion of incomplete Building for Store Room (General Authorisation) with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 8 Completion of incomplete ramp with all fitting and fixtures etc. Complete all as specified and as shown on drawings 9 Completion of incomplete Building for sentry post with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 10 Completion of incomplete Building for Ironing Room with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 11 Completion of incomplete Building for Meter & Switch House with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 12 Completion of incomplete Pump House/ UG water tank with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 13 Completion of incomplete RCC OHT Tankwith 18mtr staging with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 14 Completion of incomplete Incinerator with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 15 Completion of incompleteFlag mast with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 16 Completion of incomplete Alarm post with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 17 Completion of incompleteFire point with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 18 Completion of incomplete Refuse bin with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 19 Completion of incompleteDhobi ghat with all fitting and fixtures etc. Complete all as specified and as shown on drawings. 20 Lumpsum price worked out by the tenderer/ bidder for SITE CLEARENCE, AREA DEVELOPMENT, EARTH WORK AND EXCAVATIONas listed in Schedule ‘A’ Part-II on Serial Page No. __ 21 Lumpsum price worked out by the tenderer/ bidder for INTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-III on Serial Page No. __ 22 Lumpsum price worked out by the tenderer/ bidder for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV on Serial Page No. __ 23 Lumpsum price worked out by the tenderer/ bidder for ROAD/ PATH/ CULVERT as listed in Schedule ‘A’ Part-V on Serial Page No. __ 24 Lumpsum price worked out by the tenderer/ bidder for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI on Serial Page No. __ 25 Lumpsum price worked out by the tenderer/ bidder for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VII on Serial Page No. ___ 26 Lumpsum price worked out by the tenderer/ bidder for SECURITY FENCING AND GATE as listed in Schedule ‘A’ Part-VIII on Serial Page No. ___ 27 Lumpsum price worked out by the tenderer/ bidder for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IX on Serial Page No. ___ 28 Lumpsum price worked out by the tenderer/ bidder for EXTERNAL ELECTRIC SUPPLYas listed in Schedule ‘A’ Part-X on Serial Page No. ___ 29 Lumpsum price worked out by the tenderer/ bidder for LIGHTENING PROTECTIONas listed in Schedule ‘A’ Part-XI on Serial Page No. ___ 30 Lumpsum price worked out by the tenderer/ bidder for RAIN WATER HARVESTING / RECHARGE PIT as listed in Schedule ‘A’ Part-XII on Serial Page No. ___ 31 Schedule ‘A’ Part-XIII (MISCELLANEOUS ITEMS)Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. 5 signifies this fact only. 32 M & L for mixing of Fly ash, Clinker & stone dust in proportion of 1:3:6 ( i .e10 %Fly ash, 30% Clinker and 60% Stone dust) laying , watering , ramming and compacting with vibratory roller to get min CBR value 8% and Dry density 97 % placed at required camber and gradient complete as directed .Note:Break down details of this Items is shown in Annexure ‘B’ in Schedule ‘A’ Notes. 33 (INTERNALELECTRIFICATION)Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size dia with all fittings and accessories for modules switch/socket etc in metal flush box screws complete including PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one light/ fan point / call bell point controlled by one, one way switch complete all as specified and as directed. 34 All as per Ser Item No 13.02 here-in-above but for one ceiling/ exhaust fan point controlled by one switch complete all as specified and directed. 35 Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one 5/6 Amps socket outlet points controlled by one, one way switch on independent board complete all as specified and as directed. 36 All as per item No. 13.04 above but one 5/6amps socket outlet point on the same board with other switches complete all as specified and as directed. 37 All as per item No. 13.02 above but for one Point wiring controlled by two nos two switch complete all as specified and as directed. 38 Material and labour for point wiring with 4sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed PVC rigid conduitheavy grade of adequet size with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 4 sqmm green colour as earth continuty conductor connected to common earth dolly for one15/16 Amps socket outlet points controlled by one, one way switch modular type on independent board complete all as specified and as directed. 39 Material and labour for point wiring with 1.5sqmm (nominal area) PVC insulated and unsheathed single core FRLS (conforming to IS-694) copper cable 1100 volts grade with multi stranded copper conductor in and including concealed stove enameled steel conduit of adequet size dia with all fittings and accessories for modules switch/socket etc in metal flush box modular with cadmium plated iron screws completeincluding PVC insulated and unsheathed FRLS (conforming to IS-694) single core multi strandedcopper conductor cable of size 1.5sqmm green colour as earth continuty conductor connected to common earth dolly for one light/ fan point controlled by one, one way flame proof rotary type switch complete all as specified and as directed. 40 Supply and fixing switch flame proof rotary type with terminal box in LM6, 16 amps single pole 230 volts complete all as specified and as directed. 41 M & L for modular metal flush box 12 Module complete all as specified and directed. 42 M & L for modular white cover plate with frame, 12 module complete all as specifed and directed. 43 S & F for LED lamp 7 watt (retrofit) complete all as specifed and directed. 44 S & F LED type conical shape wall metal body with 1 no 7 Watt retrofit LED Lamp minimum lumen 700, complete all as specifed and directed. 45 S & F LED type table lamp / bed side light ( 3000k) Metal body 2 Watt minimum 50 lumen complete all as specifed and directed. 46 S & F telephone Socket (RJ-11) modular type complete all as specifed and directed. 47 S & F TV Socket modular type complete all as specifed and directed. 48 Supplying and fixing ceiling fan five star rated withBrush Less direct current (BLDC) 1200 mm sweep (without remote ) , 28 W complete withblades,down rod and accessories,230v,Min delivery 210 CFM with service value 6.00 BEE complete all as specified and as directed. 49 All as per Ser Item No 13.17 here-in-above but for 1400mm sweep, Minium air delivery 245 CFM with service value 6.00 BEE, five star rating with brushless direct current motor (BLDC) complete all as specified and directed. 50 Supplying and fixing exhaust fan made of sturdy Engineering plastic complete with lovers shutters, AC single phase, 230 V, 50 HZ , 1200 RPM, Copper winding, 250mm Sweep complete all as specified and directed. 51 Supplying and fixing exhaust fan noiseless square type metal body case , 450mm sweep heavy duty single phase (1400 RPM) ISI marked with blades flush mounting withlouvers, AC single phase 230/240 volts, 50 Hz including necessary fixing accessories and make good of surfaces complete all as specified and as directed. 52 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 6 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 53 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 8 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 54 Supplying and fixing sheet metal enclouser for Vertical DBS Triple pole and neutral 4 way double door 415 Volts when MCCB 4 Pole to be used as incommer complete all as specified and as directed. 55 Supplying and fixing MCCB 125 Amps, capacity 25kA, 4 pole, 415 volts (Adjustable thermal type & fixed magnetic setting) complete all as specified and as directed. 56 Supplying and fixing sheet metal enclouser for DBS Single pole and neutral 6 way double door with 200 Amps rated bus bar 240 Volt complete all as specified and as directed. 57 Material and labour for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less than 20 mm diawith all fittings and conduit accessories concealed type including one run 4 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note:-(i) Two runs of cable with one run earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 58 Material and labour for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less than 20 mm dia with all fittings and conduit accessories concealed type including one runs 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note :-(i) two runs of cable with one run earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 59 Material and labour for sub main wiring with four runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded,unsheathed1100 volts grade in PVC concealed rigid conduit (heavy grade) of not less tha 25 mm dia with all fittings and conduit accessories concealed type including two runs 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694)as earth wire complete all as specified and as directed. {Note :-(i) Four runs of cable with two runs earth wire and PVC conduit shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth.} 60 Material & Labour for earthing with galvanised steel earth plate electrode of size 60cmx60cm x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level,connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron or steel using GI or steel wire 4 mm dia as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation andearth work insoft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregatepit, funnel,20mm dia GI medium grade watering pipe, 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick including complete all as specified and directed. {NOTE:- (i) Each protection pipe and earth lead upto and including 7.50m length is deemed to be included in unit rate of of this item..} 61 (ROAD/PATH)M & L 225 mm thick (compacted thickness)wet mix macadam( WMM), with curshed stone aggregate and stone dust (as per design mix)of specifiedgrading, spread using mechanical paver as specified, watered, rolled & consolidated as specified to required gradient and camber complate all as specified & directed. 62 M&L for laying polythene paper black 150 micron with laps complate all as specified & directed. (Area for polythene paper without considering lap shall be measured and paid) 63 M&L and laying 150 mm thick (compacted thickness) wet mix macadam (WMM) with crushed stone aggragate of specified grading,spread using mechanical paver as specified, watered, rolled and consolidated as per required greadeant and camber complate all as specified & directed. 64 M&L for 100 m thick dry lean concrete (DLC) over a prepared subgrade with coarse and fine aggregate conforming to IS : 383, Size of aggregate not exc 40 mm (Grading and other parameters as per table 600 - 1 of MORTH, IRC SPR : 49 Specification) complate all as specified & directed. 65 M&L for cleaning and preparing the road surface and making good for road marking applying reflective thermoplastic white road marking paint (HOT APPLICATION) comforming to BIS 3262 laid down through modern propelled road marking machine in a layer of CRYSTALEX and use of all ingredients such as binder, glass, beads, titanium dioxide, calcium carbonate, interfiller thermoplastic required for glass beads per square meter by incorporating the white glass beads for reflectivity in 100mm width complete all as specified and as directed.Make of Thermoplastic Road marking paint/Retro-Reflective paint - M/s Asian Apcomark, M/s STP or M/s Shalimar Paints Ltd or M/s Berger Paints Ltd, M/s Jhonson & Nicholson Paints Ltd or M/s Jotun India Pvt Ltd. 66 (SEWAGE DISPOSAL)M&Lfor constrution of RCC Septic tankcoventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 150 users Complete all as shown on drawing and as directed. 67 M&L for constrution Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia X 4.5 M effective depth Complete all as shown on drawing and as directed. 68 (EXTERNAL WATER SUPPLY) Design, supply, install, testing and commissioning Iron removal pressure feed type filtration plant 10000 GPH to with stand pressure 10 Kg/Sq cm with catalytic and filter media (as required size and grade / mesh to obtain potable water recommended parameters as per WHO) including MS frontal pipe (duly welded), Cocks, valves, (inlet outlet, back wash, rinse, bypass complete as per manufacturers instruction). Provision of main hole Hand hole strainer including air vent system, coagulant feeder with accessories, oxidation chamber with media, (MnO2) with all accessories suitable capacity with all fitting fixture, pressure gauges, RCC/PCC foundation as per OEM recommendation. Drainage system and connected to rising and delivery system including painting and writing complete. The technical details of Oxidation chamber and Multigrade filter are as given below:- 69 A) Oxidation Chamber- (i)Feed Flow - 40 M³/Hr. (ii) Operating pressure - 3.5 kg/cm². (iii) Max. allowable pressure drop - 0.5 Kg/cm. (iv) MOC of vessel - MS. (v) Frontal Pipeline Size - 150/100mm. (vi) Media type - Manganese-di-oxide. (vii) Thickness in mm (shell and dish-ends) - 6 mm. (viii)Media Quantity - 600 Kg. (B) Multigrade Filter- (i) Flow rate - 40 M³/Hr. (ii) Operating pressure - 3.5-5.5 kg/cm². (iii) Max. allowable pressure drop - 0.5 Kg/cm². (iv) Continuous duty cycle - 48 Hrs. (v) Backwash - 20 Min. (vi) Rinsing - 10 Min. (C) Filtering Media Details- (i) Media Type - Mixed sand. (ii)Depth of sand - 2800 Kg. (iii) Depth of Gravels support - 2000 Kg. (iv) Guaranteed life of filtering media - One year.(D) Vessels Details- (i) Type Cylindrical - Vertical. (ii)Dimension in mm (DIA X HOS) - 1600 X 2300 mm. (iii) Free board for back wash - 50%. (iv)Materials - MS. (v) Thickness in mm (shell and dish-ends) - 8-10mm. {Note:-- Rate deemed to be included with the followings:-(a)Raw water and treated water tested report of all parameter from National Test House Salt Lake. (b)Training to DEL Staff with required material and maintaining log book and other register as directed. (c) Electronic flow meter-01 including necessary wiring complete. (d)Butter fly and gate valves as required.(e) 2 Nos air compressor of capacity 210 CFM with 3 Phase Motor, Starter, air pipe connection including electrical connection complete. 70 Supply, install, lowering, testing & commissioning of submersible pump set 8 stage, suitable forminimum head 40 Mtr with 635 lpm dischage with electric driven motor of capacity 15 hp, 415 V AC, TP with operational efficeiency performance and durability wide voltage range 350-440 Volts, super finished water lubricated bush bearing, with less speed drop motors with reflon bearing and sand guard complete all as specified and directed by Engr-in-charge. 71 Trail drilling of bore of size 250 mm dia upto 120 mtr depthby direct rotary/ DTHmechanical system for injection wellin any kind of soil strata including hard stone/boulders and submitting the strata detail both graphically recorded as well as strata results including testing of yield , complete all as specified and as directed. 72 Reaming of bore well from 250 mm dia to 525 mm dia hole in three steps from 250 mm to 350 mm, 350 mm to 450 mm and 450 mm to 525 mm dia bore siutable for lowering ERW Mild steel casing pipes and gravel packing for the required length (i.e 50 mtr depth) below the ground level , complete all as specified and as directed. 73 All as per item no 13.41 here-in-before but exceeding 50 mtr and upto 170 mtr depth, complete all as specified and as directed. 74 Supply, assembling, lowering and fixing in position 250 mm nominal (10) bore ERW MS housing pipe, ISI marked,of 8 mm wall thickness, screwed and socketed in random length upto 6 mtr including fitting of centralizer at regular interval into bore hole to a depth upto 40 mtr from ground level, as per IS 3589, painted both inside and outside with black bituminous paint suitable for drinking water purpose including necessary fittings & fixtures by jointing electric Arc welding , complete all as specified and as directed. 75 Supply, assembling, lowering and fixing in position 200 mm nominal (8) bore ERW MS housing pipe, ISI marked,of minimum 8.0 mm wall thickness, screwed and socketed in random length upto 6 mtr including fitting of centralizer at regular interval into bore hole to a depth exceeding 40 mtr and upto 120 mtr from ground level, as per IS 3589, painted both inside and outside with black bituminous paint suitable for drinking water purpose including necessary fittings & fixtures by jointing electric Arc welding, complete all as specified and as directed. 76 Supply, assembling, lowering and fixing in position low carbon galvanized (LCG) steel strainer pipe 200 mm nominalbore of wall thickness 7.00 mm cagetype wire wound screen ‘V’ shaped profile in suitable length having slots of size 1.6 mm width including necessary end coupling,electric Arc welding as required and including special sockets for connecting to MS pipe, complete all as specified and as directed. 77 Supply and fixing mild steel reducer suitable for (250 x 200 mm ) bore casing pipe, 10 mm thick, fitted to casing pipe as per IS 2800 by means ofelectric Arc welding ,complete all as specified and as directed. 78 M&L for carrying out electro logging test upto complete drilling depth of tube well for fixing water strata and submitting of Report including its interpretation by a qualified Hydrologist/ground water expert , complete all as specified and as directed. 79 S&Fmild steel bail plug assembly suitable for 200 mm bore casing pipe internal threaded with strong iron hook, screwed and welded to casing pipe as per IS 2800 , complete all as specified and as directed. 80 Supply, filling and packing washed pea gravels of size 2 mm to 4.6 mm all around casing pipe and slotted pipe, complete all as specified andas directed 81 S&F mild steel housing clamps 1200 mm long 100 mm wide , made out of 20 mm thick MS plate made to shape for 250 mm bore casing pipe with necessary bolts, nuts and washers at ground level, complete all as specified and as directed. 82 Developing of tube well by means of air compressor, for number of hours, until sand free clear potable water is obtained including testing by using diesel engine driven turbine pump to get maximum yield and discharge including supply of yield test result , complete all as specified and as directed. (Note : The rates of DHPP is inclusive in the quoted rate) 83 S & F well cap made out of 5 mm thick MS Plate with provn of suitable holes for passing two runs of flat 3 core PVC insulated sumersible cable motor and one run of SWR, 100 MM dia column pipe and suitable for fixing 250 mm nominal bore ERW heavy duty MS of 8.0 Mm Wall thickness casing pipe complete all as specified andas directed. 84 S&F pressuregauge with isolation cock suitable for a working pressure of 7 Kg/cm² (Liquid based High Intensity), complete all as specified and as directed. 85 Supply and laying flat PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 10 Sqmm 3 core including jointing material and connection work , complete all as specified and as directed. 86 S&F round strand steel wire rope dia 12 mm and connected clamp nut bolts fixed ,complete all as per directed. 87 Supply , lowering and fixing MS column pipe 100 mm bore, medium grade, confirming to IS, 3 meter long pipe both end flanged, threading, welding and drilling of holes, cutting of ducts of size 10 mm x 20 mm 2 No. in each flange for fixing submersible cable, including rubber gasket of suitable size, nuts, bolts, washer etc including painted internally and externally with two coat of non corrosive non toxic bituminous paint including making all type of connections as required, complete all as specified and as directed. 88 Supply , install, testing and commissioning of cubical housing cabinet type weather proof powder coated LT panel board indoor type, platform mounted factory made, totally enclosed dust and vermin proofof CPRI approved,openablefrom both front and rear side made of2 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:- 89 (i) Aluminium Bus bar 160 Amps -25 KA breaking capacity(ii) Incoming MCCB, 4 pole, 100 Amps, 415 Volt AC, 25 KA rupturing capacityQty 1 No(iii) Outgoing MCCB, 3 pole, 32 Amps, 415 Volt AC, 10KA rupturing capacityQty 4 Nos(03 For submersible pump and 01 standby)(iv) Outgoing MCB 4 Pole 32 Amps, 10 KA, 240 Volts - 01 Nos(v) Star delta motor starter suitable for 15 HP motor pump - 03 Nos(vi) LED indicating lamps - 03 Nos(vii) Digital Volt meter (Size - 96 x 96mm) 0-500 Volts with selector switch - 01 No(viii) Digital Ammeter (Size96x96mm) With selector switch including CT ( 100/5Amp) with all connection- 01 No(xiv) Matering and accessories complete all as directed by Engr-in-Charge. 90 Supply, installation, commissioning and testing of 200mmsluice valveof cast iron body flangedconforming to IS-14816, PN-1.6 Non rising type spindle and hand wheel including all jointing materials such as nuts, bolts, washers, & fibre/ rubber gasket as required complete all as specified and as directed. 91 Supply, installation, commissioning and testing of 150mmsluice valveof cast iron body flanged conforming to IS-14816, PN-1.6 Non rising typespindle and hand wheel including all jointing materials such as nuts, bolts, washers, & fibre/ rubber gasket as required complete all as specified and as directed. 92 Material and labour for Construction of brick masonry valve pit of internal dimension 90 cm x 90 cm x 90 cm depth with fly ash brick in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping including formwork MS frame with 50 x 50 x 6 mm angle iron 5 mmthick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed. 93 Material and labour for Construction of brick masonry valve pit of internal dimension 60 cm x 60 cm x 60 cm depth with fly ash brick in CM (1:4) and 10 mm thick plastering in CM (1:4), PCC (1:4:8) type D2 (Using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type CI (using 20 mm graded broken stone aggregate) as in bedding and copping including formwork MS frame with 50 x 50 x 6 mm angle iron 5 mmthick MS sheet cover plate with locking arrangements, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed. 94 Supply, install, testing & commissioning of Centrifugal pump suitable for minimum, Discharge 635 LPM at 30 Mtr head with cast iron casing, bronze impeller, SS Shaft, electric driven motor of 10 HP, 415 V, TP suitable for under ground sump and install complete including PCC foundation as per manufacture instruction complete all as specified and directed. 95 Supply, install, connecting, testing & commissioning of high pressure single head adjustable chemical dozing system of the folowing specification : (a) Adjustable high pressure 100 PSIG Power input 230 V, 50 HZ, Max flow rate 02 US GPD to 40 US GPD with mandatory assecceries like lead tubing connecting ferrules, check valves, 170 ltr FRP solutin preparetion tank with lid, port hole, inlet/outlet/drain connection, level guage ete and fitted with 900 RPM motor PVC agitator combined with 100 ltr dosing tank lid port hole inlet/outlet/drain connection, level guage etc either fitted with 900 RPM moter and PVC agitator complete all as speficified and directed.Make : Any make of E-in-C approved or ISI Marked of any make as approved by Accepting Officer. 96 Supply and laying DI Pipe 200mm dia of class K-7 Spigot and socket type with and including titan joint gasket complete in any length laid in trenches complete all as specified and directored. 97 Supply and laying DI Pipe 150mm dia of class K-7 Spigot and socket type with and including titan joint gasket complete in any length laid in trenches complete all as specified and directored. 98 M&L DI Fittings bends (any type radius and angle) tapers any type, (straigth, bend, increasing, decreasing or double socket etc) Tee pieces single branch Y junctions double branch, cross (all sockets or socket and spigout ) collars, caps and plugs upto 300 mm bore complete all as specified and directored. 99 (EXTERNAL ELECTRIC SUPPLY)suply , installation and commissioning of compact secondary substation (CSS) 315KVA comprising to following parameters:-(a) Housing to made with conforming to the norms of CPRI, CRCA sheet steel housing 3.15mm thick with corrosion resistance and all side openable hinged door and lock and key arrangements.(b)Steel parts are tested as per IS 6988.(c)Engineered for smooth air flow for natural cooling.(d)No acces to high voltage parts.(e) GI strip earthing for lightening protection and lightening spike etc.(f)Separate earthing for lighrening protection and lightening spike etc.(g)Separation steel sheet wall for VCB/ Transformer/ LT Panel.(h) Heavy lifting lugs with all equipment load.(j) Slopped roof.(k) Necessary danger plates outside fo the CSS.(l) Necessary HT and LT cable / earth strips opening.(m)Necessary form work incl foundation as per OEM recommendation. 100 (n) Circuit Breaker (CB) in SF6 insulated stainless steel enclosure. commissioning of with metering module with necessary CTs adn PT, comprising the following :- (Complete unit is to be installed inside CSS, protection accessories, Enclosoure: Metal Clad, IP-54 Protection Relay : Self Powered Alfa neumatic LCD display type internal are tested for 1 sec, fully compartmentalized sheet enclosure with automatic sagety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows:(i) Rated Voltage - 12 KV(ii)Rated Frequency - 50 Hz.(iii)Rated continuous current rating - 630 Amps(iv)Impulse withstand voltage - 75 KV(v) Bus bar rating- 150% of continuous current.(vi)Operation: Spring closing mechanism- DC motor operated with 24 volt supply, Breaker Closing- manual & Electrical through TNC switch. 101 (vii)Shunt trip coil- 230 V, AC(viii) Safety interlock locking facility - Required(ix)Breaker panel indication - ON (RED)/ OFF (Green)(x) Accessories: Mechanical counter, space heater with thermostat, fuse adn ON/OFF switch, Aux relays for remote trip/ indication for PC interface etc, cubicle illumination lamp LED 9 watt retrofit type 230 V AC, T-N switch, anti pumping contractor etc.(xi) Mimic Diagram : An operating mimic diagram shall be provide on the front side of each cubicle(xii)Battery Bank with charger for SF 6 Circuit Breaker is included in the item rate and rating of battery as described by OEM.(Note : SF 6 Circuit Breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM.The installations, calibration and testing of CB will be conducted in the presence of authorised representative of OEM by the Contractor.) (o)Transformer 315 KVA Copper wounded dry resin cast distribution type 11/0.433 KV, 3 phase, 4 wire LT output 50 Hz DYN 11 suitable for indoor installation of load tape changer with step + 7.5% upto (-) 7.5% in step of 25.% on HT side all technical specification comprising to IS 11171 update version part with all necessary satndard fittings and accessories complete after necessary testing after completion with the following specification : (i) Standard KVA Rating- 315 KVA (ii)Primary Voltage - 11 KV AC(iii) Secondary Voltage - 433 Volts . 102 (iv)Neutral earthing should be solidly earth system (v) Rated Frequency - 50 Hz with + (-) 3% Tolerance (Note : All outgoing MCCBs should be adjustable thermal and magnetic protection and Ics = 100% Icu for all MCCBs). q) Necessary interconnections for HT and LT equipment with suitable size insulated copper bus bar.(r) Necessary foundation for installations of CSS. 103 Suply , installation and commissioning of Compact Secondary Substation (CSS) 250 KVA comprising to following parameters :-(a) Housing to bemade with Conforming to the norms of CPRI, CRCA sheet steel housing 3.15mm thick with corrosion resistance and all side openable hinged door and lock and key arrangements.(b)Steel parts are tested as per IS 6988.(c)Engineered for smooth air flow for natural cooling.(d)No acces to High voltage parts.(e) GI strip earthing for lightening protection and lightening spike etc.(f)Separate earthing for lightening protection and lightening spike etc.(g)Separation steel sheet wall for VCB/ Transformer/ LT Panel.(h)Heavy lifting lugs with all equipment load.(j) Slopped roof.(k) Necessary danger plates outside of the CSS.(l) Necessary HT and LT cable / Earth strips opening.(m)Necessary form work incl foundation as per OEM recommendation. 104 (n) Circuit Breaker (CB) in SF6 insulated stainless steel enclosure. commissioning of with metering module with necessary CTs and PT, comprising the following :- (Complete unit is to be installed inside CSS, protection accessories, Enclosoure: Metal Clad, IP-54 Protection Relay : Self Powered Alfa neumatic LCD display type internal are tested for 1 sec, fully compartmentalized sheet steel enclosure with automatic safety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows:(i) Rated Voltage - 12 KV(ii)Rated Frequency - 50 Hz.(iii)Rated continuous current rating - 630 Amps(iv)Impulse withstand voltage - 75 KV(v) Bus bar rating- 150% of continuous current.(vi)Operation: Spring closing mechanism- DC motor operated with 24 volt supply, Breaker Closing- manual & Electrical through TNC switch.(vii)Shunt trip coil- 230 V, AC(viii) Safety Interlock Locking facility - Required(ix)Breaker panel indication - ON (RED)/ OFF (Green)(x) Accessories: Mechanical counter, Space heater with Thermostat, Fuse and ON/OFF switch, Aux relays for remote trip/ indication for PC interface etc, cubicle illumination lamp LED 9 watt retrofit type 230 V AC, T-N switch, anti pumping contractor etc.(xi) Mimic Diagram : An operating mimic diagram shall be provide on the front side of each cubicle. 105 (xii)Battery Bank with charger for SF 6 Circuit Breaker is included in the item rate and rating of battery as described by OEM.(Note : SF 6 Circuit Breaker complete will be obtained directly from the OEM and not from the authorised system assemblers of OEM.The installations, calibration and testing of CB will be conducted in the presence of authorised representative of OEM by the Contractor.) (o)Transformer 250 KVA Copper wounded dry resin cast distribution type 11/0.433 KV, 3 phase, 4 wire LT output 50 Hz DYN 11 suitable for indoor installation of load tape changer with step + 7.5% upto (-) 7.5% in step of 2.5% on HT side all technical specification comprising to IS 11171 update version part with all necessary standard fittings and accessories complete after necessary testing after completion with the following specification : (i) Standard KVA Rating- 250 KVA (ii)Primary Voltage - 11 KV AC 106 (iii) Secondary Voltage - 433 Volts (iv)Neutral earthing should be solidly earth system. (v) Rated Frequency - 50 Hz with + (-) 3% Tolerance.(p)LT Panel for 250 KVA Transformer made with 2 mm CRCA sheet with necessary angle iron frame and vermin proof font side openable double door with necessary locing arrangement opening for bus bar / cable entry opening for natural air ventilation / cooling necesary Ammeter, Voltmeter, Selector switch, CTs , suitable size bus bar, paints and primer with Air Circuit Breaker (ACB) as incomer 630A, 50 KA, 415 V , AC, 50 Hz, 4 Pole with neccesary setting and microprocessor control draw out type bus bars, as outgoing MCCB 200 Amps, 35 KA - 02 Nos, MCCB 160 Amps, 35 KA - 02 Nos & 32 A MCB 4 Pole - 04 Nos. (Note : All outgoing MCCBs should be adjustable thermal and magnetic protection and Ics = 100% Icu for all MCCBs).(q) Necessary interconnections for HT and LT equipment with suitable size insulated copper bus bar.(r) Necessary foundation for installations of CSS. 107 Supply and fixing LED street light fittings on ploes capacity 45 Watts, high pressure die cast aluminum housing IP 66 rating front cover made of toughened clear glass, suitable for pole mounting wih bracket arm 40mm dia, Gl light grade pipe upto 1.4 m long, bend to required shape, clamp 40mmx6mm or required length including nuts & bolts fixed on steel poles complete all as specified.Model No : ENDURASUNDOWNSL45WLED765PASYBOTG of make : Havells or equivalent make as per Appendix D. 108 Supply & Fixing junction box with 3 Phase terminals and size of box 130mm x 180mm x 77mm or nearest higher size made of polycarbonate with IP 66/67 degree of protection, dust proof, water tight,shock proof, fire retardant,with internally embedded gasket fitted with heat treated bakelite for terminals block and PVC Glands for cable entry complete all as directed 109 M&L Three core 1.5sqmm(nominal area)service wire PVC insulated copper conductor FRLS, multi stranded, unsheathed 1100 volts grade IS-694 marked andfrom junction box to street light fitting through steel pole withPVC conduit & necessary clamps, bolts & nut etc required for fixing complete all as specified and directed. 110 Supply , install, testing and commissioning of cubical housing cabinet type conforming toCPRI approved LT panel board outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer.The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowings :-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -200 Amps , cable entry (incomming and outgoing ) form bottom with cable gland Incomming : 125 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No (Incoming from CSS)Outgoing -(a) MCCB 4 pole 100 Amps 25 kA - 02 Nos (for signal unit and 1 standby)(b) MCCB 4 pole 16 Amps 25 kA - 2 Nos (For OFFR Living ,meter or switch house and and 01 No for street lights)(c)Timeswitches astro type 250V sigle phase of 20 Amp rating with contactor(d) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos(e) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No (f) LED indicating lamps -03 Nos 111 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approved LT panel board outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer.The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:- System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -400 Amps , cable entry (incomming and outgoing ) form bottom with cable glandIncomming : 250 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No(incoming from CSS)Outgoing -(a) MCCB 4 pole 200 Amps 35 kA - 01 Nos (Adm buidling)(b) MCCB TPN 16 Amprs 25 KA-02 Nos (Guard house and standby)(c) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos(d) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No(e) LED indicating lamps -03 Nos. 112 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approvedLT panel board Outdoor type, platform mounted factory made dust proof, weather proof powder coated totally enclosed dust and vermin proof openablefrom both front and rear side made of3.15 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos) , earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coats of synthatic enamel paint over a coat of red oxide primer. The panel should be suitable for 415 volts , 50Hz , 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing:-System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -600 Amps , cable entry (incomming and outgoing ) form bottom with cable glandIncomming : 315 Amps MCCB FP,35 KA, 415 Volts, 50 Hz-01 No(incoming from CSS)Outgoing -(a) MCCB 4 pole 125 Amps 35 kA - 03 Nos(02 Nos for OR Accomodation and 01 Nos standby)(b) MCCB 4 pole 63 Amps 25 kA - 01 Nos(JCO Accomodation and JCO Club) (c) MCCB 4 Pole 25 Amprs 25 KA - 01 Nos (Drying and ironing room)(d) MCCB TPN 16 Amprs 25 KA - 02 Nos (Street lights and one standby)(e) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No (f) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos (g) LED indicating lamps -03 Nos (h)Timeswitches astro type 250V sigle phase of 20 Amp rating with contactor 113 Supply, install, testing and commissioning of Automatic Power Factor Correction (APFC) panel board of aggregate capacity 15 KVAR suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz, outdoor type, cubicle, floor mounted, free standing dust and vermin proof, air ventilation made out of 3 mm thick CRCA sheet duly powder coated, Manufactured shall be CPRI norms and as approved by GE, factory made.Panel board shall have front and rear opening with hinged type doors and rubber gasket, handles, industrial type locking arrangement, cable alleys, switch gear compartment, bottom cable, entry holes for incoming and outgoing cables, earthing terminals, danger notice plate, Aluminum bus bar duly covered with heat shrink sleeves of colour coded duly fixed on DMC / SMC insulators housed in a separate bus bar chamber including control wiring with PVC insulated, flexible, multistranded copper conductor cables of adequate size and of adequate length for connecting of capacitors, contactors etc duly ferruled crimped with suitable lugs / thimbles and including connecting of incoming and outgoing cables. Panel board shall be mounted on and including MS angle iron frame of suitable size duly painted and PCC1:2:4 type B1 for foundation / Platform to suit the site requirement complete all as specifiedand directed and comprising of following:-(i) APFC relay microprocessor based digital display type of 9 stages suitable for operation of PF upto unity – 01 No. 114 (ii) MCCB 320 Amps, 4 pole, 50KA, 415V, 50HZ – 01 No for incoming.(iii) MCCB 80 Amps, 4 pole, 25KA, 415V – 03 No’s for capacitor outgoing.(iv)MCCB 40 Amps, 4 pole, 25KA, 415V – 01 No for capacitor outgoing.(v)MCCB 16 Amps, 4 pole, 25KA, 415V – 05 Nos for capacitor outgoing(vi) MCB SP 0.5 to 5 AMPS, ‘C’ Curve, 240V-09 Nos as per circuit control.(vii) Capacitor Bank 2 KVAR, 3 phase, 440V MPP type including suitable rating contractor -05 Nos.(viii) Capacitor Bank 2 KVAR, 3 phase, 440V MPP type including suitable rating contractor -02 Nos.(ix) Capacitor Bank 1 KVAR, 3 phase, 440V MPP type including suitable rating contractor -01 Nos. 115 (x) LED indication lamps RYB – 01set.(xi) Auto / manual selector switch -01No.(xii) Push button and indication lamp for each capacitor bank -01 set.(xii) Digital voltameter with selector switch -01set.(xiv) Digital ammeter with selector switch & CT’s -01.(xv) Aluminium bus bar TPN 480 Amps rating -01 set.Note: The contractor should be factory inspection and drawings approval by the GE / Engineer-in-Charge before procurement after commissioning of APFC panel the power factor (PF) to achieve 0.95 to 0.99 mandatory at any load condition automatically. 116 Supply and fix solar street light smart integrated solar system all in one with MPPT (Maximum Power Point Tracking) charge controller ,Tilable LED Panel,Adjustable AIO mounting angle ,mono crystalline solar panel ,PIR motion sensor, and 6m tubular pole with 30 wattLED light at a rate 100 lm/w, 60wp, 75 AH (Lithium ferrous phosphate battery luminaries must have a life of greater than 50,000 hours and have IP 66 rating, the modules are to bedesigned to with stand corrosive atmosphere and heavy wind loads. the modules are to be certified for standers IEC 61215, IEC 61730 (Safely class I & II) complete all as specified and directed. 117 Supply and fix LED post top lantern decorative typeo fttings for 360 degreee indirect light on pillars of capacity 40 watts high pressure die cast aluminium housing IP 65 rating, suitable fr mounting 40 dia GIlight grade pipe upto 0.5 m long or required length including nuts and bolts and fixed complete all as specified and directed.Model No : RUBYPT40WLED757PSYMTOPC OF MAKE : Havels or equivalentmake as per Appendix D 118 M&L fpr boring holes horizontally under road without damaging the surface of road (minimum 1 mtr below the road surface/ footpath with the help of GI tubing not exceeding 100mm dia bore for passing of UG cable complete all as specified and directed. 119 (REFGIGERATION & WATER COOLER) Supply, installation, commissioningofrefrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 308 - 315 ltrs capacity, conforming to IS 15750 (2006) for frost free, with power saver compressor with minimum BEE 5 star rating complete all as specified and as directed. 120 Supply, installation, commissioningofrefrigerator single door, electric driven (single phase) 230V AC, 50 Hz, 192 - 210 ltrs capacity, conforming to IS 1476 for direct cool with power saver compressor with minimum BEE 5 star rating complete all as specified and as directed. 121 Supply, installation, commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hzminimum capacity 320 ltrs, BEE 5 star rating complete all as specified and directed. 122 Supply, installation, commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hzminimum capacity 400 ltrs, BEE 5 star rating complete all as specified and directed. 123 Supply, installation, commissioning of Water cooler fullystainless steel, electric driven single phase having approx storage capacity of 80 Ltr and nominal cooling capacityof 40 Lts per Hour as per latest IS 1475 and BEE 5 star ratingcomplete all as specified and directed. 124 Supply, installation, commissioning of Water cooler fullystainless steel, electric driven single phase having approx storage capacity of 120 ltr and nominal cooling capacityof 60 Lts per Hour as per latest IS 1475 and BEE 5 star ratingcomplete all as specified and directed. 125 S & F Voltage stablizer of capacity 2 KVA for automatic operation, single phasewith neutral, air cooled indoor type and disign defore input Voltage variation between 170 Volts to 250 Volts with output Voltage stabiilized at 230 Volt with accuracy of + 2.5% complete all specified and director. 126 S & F Voltage stablizer of capacity 1 KVA for automatic operation, single phasewith neutral, air cooled indoor type and disign defore input Voltage variation between 170 Volts to 250 Volts with output Voltage stabiilized at 230 Volt with accuracy of + 2.5% complete all specified and director. 127 (DG SET) M&L Earthing complete with galvanised steel earth plate electrode 60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected tousing galvanised iron strip 32×6mm as earthing lead earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated by Engr-in-charge including testing on completion. 128 Supply and installation testing and commissioning silent Diesel Enginegenerating set 415 volts 40 KVA3 phase 0.8 power factor, 50 Hz, 1500RPM self exicited self regulated brushlessAC generator installed including AMF panel,suitable for ambient condition at Panagarh and confirming to condition under ISO 3046, IS:10001/ 10002,BS 5514/5000 with capacity of 10% overloading for one hour in every twelve hour duration and including the following accessories :- (A) Alternator:- Synchrounous alternator rated at 40 KVA suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p.f (lag) suitable for 50 Hz, three phase, 4 wire system.The alternator shall be brushless, single bearing, self excited/ self regulated with an AVR. The alternator will be suitable for climate and shall generally confirm to IS: 4722 :2001. The salient features of the alternators are :- (a) +-1% voltage regulation (max) in static conditions.(b) IP:23 protections with class H insulation.(c) Permanent lubricating bearing. 129 (B) Diesel Engine:- Adquate capacity of diesel engine water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500RPM, as per relevant IS/BS complete with standard accessories. (C)ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent (to comply GRIHA and other agencies norms) canopy shall be of nut bolt type construction. Critical processes of punching is done on CNC machines to maintain dimentional accuracy of holes within 0.1 mm.Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone.Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility (D) AMF panel : Automatic Mains Failure (AMF) panel made of CRCA sheet of 2 MM thick including necessary arrangement to install, testing and commissioning & connecting ot load cable to up ot changeover switch, suitable capacity of 4 pole MCCB complete all as per OEM recommendation.(E) Civil Works :- All civil works including PCC platform and related foundations incl for panel and equipments incl making goodof disturbed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommendedby the manufacturer. 130 (F) AMF Panel Specification shall be as per manufacture instruction.Note :-The contractor shall be arrange for artificial load resistive for testingof DG set at site and the cost is deemed to be included in the quoted ratesMAKES :- Make of engine : CUMMINS/KIRLOSKARGREEN/ASHOK LEYLAND/ GREAVES COTTON.Make of alternator : KIRLOSKAR GREEN / ALSTOM / CROPTON GREAVES /SIEMENS 131 Supply, erecting,testing aand commissioning of solar water heating system with heat exchanger for cold & warm regions respectively with solar evacuated tube collection conforming to IS : 12933 (Part - i ) with amdt No 1 and IS : 12933 (Part 2) /2003 suitable for inlet water with chlorine and fluorine content up ot 100 ppm and supply hot water at the outlet of 200 litters capacity with elctrical back up meeting specifications as under and comprising of followings :-Supply and fixing rotational moulded polyethylene water storage tank (Cylindrical Vertical with closed lockable top with lid and locking arrangement) hoisted and fixed in position all as specified in SSR Part -I of capacity 200 Litters complete for storage of cold water feeding to solar water heater, including staging made out of MS Angle iron 50x50x6 mm all as specified and directed at site by Engineer-in-Charge.Material :- Soalr water heating System : Comprising of solar Evacuated tube Collector, Collectors stand assembly.Staniless steel insulated hot water Storage tank with heat exchange and various other components . Solar evacuated tube collector component shall have :Evacuated tube collector component shall have : solar Evacuated tube collector cover plate made of toughened glass.Sheet for absorber made of copperAbsorber made of copper sheet and copper tube.the minimum thickness of Aluminium shall be as under:- (a) Channel section for sides 1.6mm (b) Sheet for bottom 0.7 mm (c) Support for glass retaining 1.2 mm sheet for entire body 1.0 m AbsorberAbsorber shall consist of riser, header and sheet for absorer. The diameter of header shall be 25.4 +/- 0.5 mm and thickness 0.71 mm. The Diameter of riser shall be 12.7 +/- 0.5 mm and thickness 0.56 and made of copper only. 132 S & F Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore complete all as specified and directed. 133 Rain water Harvesting /Recharge PitS & F 150 MM perforated UPVC pipe with 20% Perforation complete all as specified and directed. 134 S & F 150mm bore PVC (SWR) vent cowl complete all as specified and directed. 135 M&L for hand packed gravel (Stone chips 12.50mm) for filling in bore holes and inside of recharge pit complete all as specified and directed. 136 Boring for 350 Mm Dia bore to a depth of 40 mtr in soil and getting out and disposal of spoil to a distance of 50 mtr using DMC method ( Direct mud Circulation) complete all as specified and directed. 137 GRIHA RATING FOR FOLLOWING BUILDING:-Minimum 3 star GRIHA rating shall be obtained for the following buildings which includes pre-certification and final ratings from approved aggency(a) OFFICER/ ADMIN BLOCK (b)SINGLE living JCOs ACCN(c) SINGLE living HAV/OR ACCN (T/S)Note :- 01The GBA (Green Building adviser) ofr obtaining GRIHA certification shall be approved by Accepting Officer.02. The GBA shall be responsible for all necessary actions for obtaining final GRIHA rating as per following guide lines:- (a) Pre-Cretification :-1. Submission of GRIHA per certification documents to certification agency as applicable immediately after the issue of Job/Work order.2. Analysis and suggest improvement/correction in the MEP/Other relevant drawings/documents and draft tender of the subject work for GRIHA star Rating (Min Three Star).3. Preparation, Submission & uploading all the documents in accordance with the GRIHA requirment, documentation shall be supported by drawings, test result quipment catalogues & calculations.4. Selection of equipment & material.5. To facilitate the planning team for selection of appropriate energy efficient & eco -friendly technologies, equipment & materials for the building e.g lighting system ,white goods, water treatment technologies, renewable energy, nontoxic paints, rapidlly renewable materials, recycled materials, ecofriendly materials etc.6. preparation of vendors & suppliers list for inclusion in the tender & working out specification of equiptment & materialto suit the GRIHA requirement. 138 7. Develop templates for GRIHA calculations to achieve certain points, this include materials related criteria, construction of waste management at site, energy calculation etc.8. conduct solar path analysis for each to achieve the best design ( shading device, Orientation etc.)9. Conduct solar path analysis for each fenestration to achieve the best design ( shading device, orientation etc)10 Perform day light analysis to ensure optimun condition achieved as per the guidelines provided by ECBC 2007.11. Perform day light analysis for window -wall ration, glass peropertiies (SHGC) & Providing recommendations to meet the compliance of ECBC 2007.12. Perform hourly calculation to show that thermal comfort condition as well as non-condition area are cachieved.13. Perform energy simulation to predict the energy performance of energy system in the bldg is less than the benchmarked energy perfomance as prescribed by GRIHA.14. Submit of ECBC compliance document to show that compliance fo mandatory requirment of ECBC are meet.15.Submission of draft specification to comply with relevant criteria of GRIHA for inclusion in tender documents.16. Liasoning and coordinating with GRIHA team for registration of project, uploading relevant document. Responding ot queries, observations, modification and corrections given by GRIHA team within specified time framed and reporting client with lates update.17. completion of all documentation requirement and formatlities before conclusion of main bldg. Contract and obtaining pre-certification with 3 or above star rating. 139 Final Rating:-Acquiring of Final Post GRIHA (minimum 3 star rating) certification approval from GRIHA including changes in drawings/ design during execution of work.Note:-The consultancy fees is inclusive of the following:-1. Pre-certification Registration Fees2. Certification registration Fees3. Site visit of GRIHA Official4. Site visit of GRIHA Official5. Third party EvaluatorPayment Schedule :-(i) 10% after pre-certification(ii) 50% at finalisation of specification(iii) 40% after obtaining GRIHA certification 140 Providing and fixing white vitreous china floor mounted water closet of size 360X640X685 mm of approved shape including providing and fixing vitreous china cistern with duel flush fitting, of flushing capacity 3 litre/6litre (adjustable to 4litre/8litre, including seat cover, and cistern fitting nuts, boltsand gasket etc complete all as specified and directed.Model No: SLS-WHT--6851P of make Jaquar of equivlent make/model as specified in Appendix D. 141 Providing and fixing white vitreous china wash basin for under counter mounting, specially fabricated brackets, painted whit, brass tap, 32 mm C.P. Wast, 15mm C.P. Brass self closing tap, connection pipe & rubber adopter for waste connection, complete including cutting and making food the walls, wherever requird complete all as specified and directed.Cat No : CNS_WHT_705 for wash basin ofmake Jaquar& Cat No PRS-031 for 15mm C.P brass tapof make Jaquar or equivlent make/model as specified in Appendix D. 142 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. Size 485 X 310 X 710 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitablebrackets all as per manufacturers specification and direction of Engineer-in-Charge.Cat No : URS-WHT-13255 of make of equivlent make/model as per Appendix D 143 Providing and Fixing of P.V.C waste Flexible pipe 40mm dia for sink and Urinal including PVC waste fittings complete including cutting and making good the walls, wherever required complete all as specified and directed 144 Providing and Fixing of P.V.C waste Flexible pipe 15mm dia for sink and Urinal including PVC waste fittings complete including cutting and making good the walls, wherever required complete all as specified and directed 145 Providing and fixing C.P. Brass angle valve 15mm dia for basin mixer and gyser pointsconforming to IS : 8931 complete all as specified and directedCat No FLR-CHR-5053N of make of equivlent make / model as per Appendix D. 146 Providing & fixing Liquid soap container of standard shape with bracket of the same material with snap fitting of approvedquality and colourcomplete all as specified and directedCat No : CAN-1135N of make of equivlent make / model as per Appendix D 147 Provinding & fixing Sink cock 15mm nominal bore of approved quality and colour complete all as specified and directedCat No : FLR-5347ND of make of equivlent make / model as per Appendix D 148 Provinding & fixingCP Brass Health faucet with 1.5M S.S Flexible Tube with wall hook including screw, Nut, bolts, cutting wall/floor and making good the same whatever required complete all as specified and directedCat No : ALD-CHR-583 of make of equivlent make / model as per Appendix D 149 Provinding & fixingCP Brass Bid cock Including wall fange, Connections, screws, nut, bolts, cutting wall/floor and makiing good the same whatever requiredcomplete all as specified and directedCat No : FLR 5037Nof make of equivlent make / model as per Appendix D 150 Provinding & fixing sink CP Wall mount double Robe Hookfixed to wooden cleats with C.P Brass screws, cutting wall/floor and making good the same whateverrequired complete all as specified and directedCat No : CAN-1161N of make of equivlent make / model as per Appendix D 151 Providing and fixing of straight type Macfit Single body push fit type WC pan connector with factory supplied srpring loaded seal guard of mcalpine, UK with integral single mould sealing fins made of flexible eva body, including bush/ adaptor for use with C.I pipe as supplied with the pan connecrtor complete all as specified and directed. Model : MAC 1 of make Macalpine of equivlent Model as approved by E-In-C or Accepting officer. 152 HOT WATER SUPPLYSupply, installation, commissioning and testing of water heater storage type, electric driven, capacity of 15 litres, single phase, 230V AC 50 Hz, closed type ISI marked vertical wall mounting, with steel body cover and Copper inner container, BEE 5 star rated. Complete with all accessorios such as safety valve thermostat connection pipe complete all as specified and directed. 153 Supply, installation, commissioning and testing of water heater storage type, electric driven, capacity of 25 litres, single phase, 230V AC 50 Hz, closed type ISI marked vertical wall mounting, with steel body cover and Copper inner container, BEE 5 star rated. Complete with all accessorios such as safety valve thermostat connection pipe complete all as specified and directed. 154 S&F CP Brass stop cock (concealed) of 100mm dia of standand design conforming to 15:8931 complete all as specified and directed. 155 Providing and fixing sound insulated PP piping system as per ON EN 1451 _ Part I-6 & EN 12056 part I-5 with 3 Layer pipe made of PP-C +PP-MV+PP-C in Blue Ral 5014 (Halogen and calcium free) colour, Push-fit type, food safe having high impact and stiffness, offering sound level of not more than 22dBA at a flow rate of 4 I/S and having pipe ring stiffness as per ISO/DIS 9969 and tightness as per EN 1277/B and C and DIN 19560 with all necessary fillings in blue colour, filled with factory fitted lip ring of make : Polyplast or equivalent make as approved by GE suitable for PP110mm dia Pipes complete all as specified and directed. 156 All as per item No 14.24 here-in-after but for PP 75mm dia pipes 157 All as per item No 14.24 here-in-after but for PP 40/50mm outer dia meter pipe (For wash basin etc) 158 Providing and fixing floor trap with minimum 50mm water seal with rubber seal on inlet to push fit hopper for indirect waste connection, 110mm inlet& 110m outlet long hight complete all as specified and directed. 159 Providing and fixing 110 X 50mm UPVC Floor Drain / Plain Floor trap complete all as specified and directed. 160 Providing and fixing SS Grating Over Floor Trap& Floor Drain 127 X 127mm complete all as specified and directed. 161 M&L concrete bed to drain pipe including packing under and lacking against the side of pipe after they are laid and tested with PCC (1:4:8) type D-2, for 110mm dia complete all as specified and directed. 162 All as per srl item No 14.30 here-in-after but for PP 40/50mm outer dia meter pipes. 163 S&F clean out cap plug (FCO/COP) for cleaning of same materials (POLO KAL NG) for PP 110mm dia complete all as specified and directed. 164 S&F 3-layer PPR-polypropylene random copolymer conceled pipes SDR 7.6 (PN-16) UV stabilized and antimicro bial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fitting for 50mm outer dia laid in trinches complete all as specified and directed.