Tender For Provision Of Fire Suppressor System At Af Station Jaipur.; 1.00 S & F powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and all as specified and directed. 2.00 S & F powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and all as specified and directed. 3.00 M & L pre-laminated particle board, 12mm thick interior grade, pre-laminated both sides with decorative choice laminations, fixed to aluminium doors/partition complete all as specified and directed. 4.00 S & F 4.8 mm thick sheet glass ordinary quality and glazing with beads fixed with metal panel pins exceeding 0.50 sqm in each pane all as specified and directed. 5.00 S & F Butt hinges, 100mm size extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 all as specified and directed. 6.00 S & F extruded aluminium alloy handles fabricated type, anodised 150mm size all as specified and directed. 7.00 S & F Aluminium anodised barrel tower bolt of extruded section 200mm long all as specified and directed. 8.00 S & F door closer hydraulically regulated, aluminium extruded section body, designation No. 3, universal type suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 kg complete all as specified and directed. 9.00 S & F for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed. 9.01 E/M works 10.00 Supply, installation, testing & commissioning of fk-5-1-12 Seamless Cylinder CCOE Approved, comply with UL 2166 complete with valve assembly and pressure gauge with a safety burst disc and a safety cap of following capacity as mentioned are as under complete all as specified and as directed.Note:- (i) System pressure should be 42 Bar UL Listed only.(ii) The cylinders has to be corossion resistant and burst disc should be rated to + 5 deg 65 deg centigrade complete all as specified and as directed. 10.01 34 Ltr PESO approved MS Seamless cylinder as per IS 7285 standard,Cylinder neck thread 2 ½” – 12 UN -2B / 3”-12 UN – 2B,Test pressure Minimum 225 Bar,Working pressure 0°C to +54°C, Valve body-Brass, Further components of valve are made using stainless steel, elastomeric gasket materials, brass, plastic as per UL standard 2166, Pressure gauge made of Brass/ Stainless Steel Polycarbonate. Thread 1/8” -27 NPT, Dial dia-41 mm, Pressure range 0 to 70 bar Temperature rating 0 to 55 ºC complete all as specified and as directed. 10.02 80 Ltr PESO approved MS Seamless cylinder as per IS 7285 standard. Cylinder neck thread 2 ½” – 12 UN -2B / 3”-12 UN – 2B. Test pressure Minimum 225 Bar. Working pressure 0°C to 54°C, Valve body-Brass, Further components of valve are made using stainless steel, elastomeric gasket materials, brass, plastic as per UL standard 2166. Pressure gauge made of Brass/ Stainless Steel Polycarbonate. Thread 1/8” -27 NPT, Dial dia-41 mm. Pressure range 0 to 70 bar. Temperature rating 0ºC to 55 ºC complete all as specified and as directed. 10.03 140 Ltr PESO approved MS Seamless cylinder as per IS 7285 standard. Cylinder neck thread 2 ½” – 12 UN -2B / 3”-12 UN – 2B. Test pressure Minimum 225 Bar. Working pressure 0°C to 54°C, Valve body - Brass, Further components of valve are made using stainless steel, elastomeric gasket materials, brass, plastic as per UL standard 2166. Pressure gauge made of Brass/ Stainless Steel Polycarbonate. Thread 1/8” -27 NPT, Dial dia-41 mm. Pressure range 0 to 70 bar. Temperature rating 0ºC to 55 ºC complete all as specified and as directed. 11.00 Supply, installation, testing & commissioning of Novec 1230/ FK-5-1-12 Fire Protection fluid compound of carbon, fluorine and oxygen (CF3CF2C (O) CF (CF3) 2) comply with UL standard 2166 filled in cylinders non toxicity of the agent and its minimal impact on the environment (low global warming potential and zero ozone depletion potential) complete all as specified and as directed.Note:- First filling of gas in cylinders included in quoted rate 12.00 Supply, installation, testing & commissioning of Electric Control Head, electrically operated from the Detection & Control System Electric Actuator made of brass with nickel plated work on 24 Volts DC, Max current 0.5 Amps, Power consumption 12 Watts, Temp rating (-) 20 ºC to (+) 55 ºC, Thread size M 36 x1.5 complete all as specified and as directed. . 13.00 Supply, installation & testing of Manual Actuator for manual operation made of Brass or Stainless steel, neck thread M 36 x 1.5, temp rating 0ºC to 54ºC complete all as specified and as directed. 14.00 Supply, installation & testing of Discharge hose made of synthetic rubber, Coated steel, working pressure Max. 70 bar inlet pressure, comply with UL 2166, burst pressure 360 Bar, nominal bore DN 33, maximum bending angle 8 ºC, Inlet thread -Screw cap 1 7/8”- 12 UN (Female) 90°-bow, outlet thread - G1 1/2 (Male) Straight, Temperature ratiing 0°C to 54°C. Lenth 350 mm to 500 mm, (use with 34, 80, 120 & 140 Ltrs capacity Cylinders) complete all as specified and as directed. 15.00 Supply, installation & testing Warning Sign, Non tearable, water proof, auto glow sticker, of size 300 mm x 200 mm paste out side the room complete all as specified and as directed. 16.00 Supply, installation, testing & commissioning of Pressure Operated Control Head which allows for pressure actuation slave cylinders and is mounted directly on top of the slave, Pneumatic Actuator to be made of Brass,Thread size M 36 x 1.5, operating pressure 6 bar, Temperature rating 0ºC to 55 ºC complete all as specified and as directed. 17.00 Supply, installation, testing & commissioning of Flexible Actuation Hose made of Synthetic Rubber, end fitting- Stainless Steel, Maximum pressure 300 bar, Connections -Male thread BSP G1/8” flat sealing (included straight), Connecting nut M12 x1.5 DKOL 6 L (24°cone) Straight, Minimum Bending Radius R - 100 mm, Temperature Rating 0°C to 54°C, Length 500 mm to 1000 mm, (Pilot pressure is directed to a pressure operated control head on each cylinder valve using 1/4 inch complete all as specified and as directed. 18.00 Supply, installation, testing & commissioning Bleeder valve installed on the end cylinder to release additional pressure, Bleeder Valve body- Stainless Steel internal components made of stainless Steel & Elastomeric Gasket Material, Functional Principle: Closes and Opens automatically, Status (Open / Closed) closing Pressure : ~0.4 Bar increasing pressure (at volume flow > 40 l/ min) Opening Pressure - 0.5 Bar (+/- 0.2 Bar) Falling Pressure, Inlet Thread-G 1/8” (M), Temperature Range- (-) 20°C to (+) 65°C. Maximum Pressure Pmax- 207 Bar complete all as specified and as directed. . 19.00 Supply, installation, testing & commissioning of Manifold Check Valve installed at the discharge manifold to allow removal of any FK- 5-1-12 cylinder from the manifold while still retaining a closed system, Check valve made of Stainless Steel & Elastomeric Material, Nominal Bore- 4 mm (12.57mm²), Maximum Pressure- 360 Bar, Inlet Thread- 1/8” BSP (F), Outlet Thread- 1/8” BSP (F), Temperature Rating 0°C to 54°C complete all as specified and as directed. . 20.00 Supply, installation & testing Manifold installed to connect multi cylinder bank made of Carbon Steel Seamless Pipe, Schedule 80 ASTM A106 Grade B pipe to be used, Maximum Working Pressure 70 Bar, Temperature Range 0°C to 54.4°C complete all as specified and as directed. 21.00 Supply, installation, testing & commissioning of Discharge Nozzles made of Stainless Steel, Temperature Rating 0°C to 54°C, Orifice size as per OEM flow calculation, designed to provide the proper flow rate and distribution of FK- 5-1-12 to total flood a hazard area (-)180 ºC. / 360 ºC complete all as specified and as directed.Note:- Acoustic calculations should be submitted as per technical specifications for approval. 22.00 Supply, installation of Cylinder Strap for cylinder made of Mild Steel, size - 40 mm x 5 mm Thickness, Temperature Rating 0ºC to 54ºC complete all as specified and as directed. 23.00 Supply, installation MS Fabricated cylinder stand made of mild steel.angle of size 40 mm x 6 mm Thickness, Temperature Rating 0ºC to 54ºC complete all as specified and as directed. 24.00 Supply, installation, testing & commissioning of Manifold Supervisory Switch for indication of discharge of system made of Stainless Steel, Threads- 1/2” BSP (M), Temperature Rating (-)18ᵒC to (+) 54.4ᵒC, Test Pressure 173 Bar, Operating Pressure 5 Bar,Voltage Ratings 15 Amps/ 240 Volts, AC complete all as specified and as directed. 25.00 Supply, installation & testing of Cylinder pressure switch or contactable guage in the cylinder to monitor low pressure indication made of Plated Steel, Switch type SPST- NO, Thread Connection- G1/4”, Electrical Connections- D6.35 x 0.8, Temperature Rating (-) 30ᵒC to (+) 65ᵒC, Test Pressure 70 Bar, Voltage Ratings 240 Volts, AC/ 120 Volts DC- I Amp, Operating Pressure/ Action Pressure 41 Bar, Reset Pressure 35 Bar complete all as specified and as directed. 26.00 Supply, installation, testing & commissioning Smoke Detector installed to trace (roof) smoke in cross zone, Photoelectric RE 316SH-2L & Heat Detector should be UL approved, Dual LED’s for 360° visibility, Operating Voltage: 9 ~ 33 Volts DC, Reset Voltage- less than 1 Volt, Thermal Rating 59°C (138°F), Rate of Raise of Temp 11.1°C / min (20°F/min), Smoke Sensitivity- (1.9 ± 0.76) % / ft, Operating Temperature (-) 10 °C to (+) 37.8 °C complete all as specified and as directed. 27.00 Supply, installation, testing & commissioning of 4 zone Gas Release Panel UL Listed, Initiating Device Circuits- All Zones are Class B Style B/C operation (Programmable, .Primary Power (120 – 220) Volts AC ± 10%, 50 Hz, 2.5 Amps, Normal Operating Voltage (14–21) Volts DC, Alarm Current (15–30m Amps), Short Circuit Current 45m Amps, Maximum.Loop resistance 100 ohms Maximum, End-Of-Line Resistor 3K9, 1/2 watt. Standby Current 7m Amps (2 mAmps for Detectors) complete all as specified and as directed. 28.00 Supply, installation & testing Centralized Panel, wall mounted made out of MS powder coated/ABS, of size 350 x 350 x150 mm for monitor pressure of group of protection areas of following specifications complete all as specified and as directed. (i) Indications :- Healthy,Fault, Silenced, Acknowledged.(ii) Output :- Built in Buzzer, 3 nos PF relay contact suitable for 230 Volts AC/ 5 Amps.(iii) Power rating :- 230 Volts AC/ 5 Amps, 30 Volts DC/ 2 Amps(iv) Battery Back up :- Required(v) Push buttons :- 1 for Silencing and 1 for Acknowledgement, 1 for reset. 29.00 Supply, installation & testing of 2 core x 1.5 sq. mm, twisted pair Copper FRLSH armoured fire alarm cable with RED insulation, Type A ST1 PVC insulated, Aarmoured FRLSH Cable 650 Volts as per IS- 1554, with GI saddle spacers every 0.3 mtr intervels with Single compression Cable Glands, ABS Junction Boxes (wherever required), terminals, Ferruling complete for Centralized monitoring panel complete all as specified and as directed. . 30.00 Supply, installation, testing & commissioning as set of Manual release in MS enclosure with lock and key arrangement or break glass type, UL Listed with Painted Die Cast housing, 14 Gauge plated steel black plate, Corrosion inhibited surface, Terminal block ( 4 position), Single gang mounting, 10 Amps, 120 Volts, AC snap action switch (SPST). Electrical Switch- 10 Amps @120 Volts AC, Weight- 15.50 ounce (oz)/ 420 grams, Manual Pull station Dual Action complete all as specified and as directed. 31.00 Supply, installation, testing & commissioning as set of Manual Abort Station switch in MS enclosure with lock and key arrangement or break glass type, UL Listed with Painted die cast housing, 14 Gauge plated steel black plate, Corrosion inhibited surface, Terminal block (4 position), Single gang mounting, 10 Amps ,120 Volts, AC snap action switch (SPST), Electrical Switch- 10 Amps @ 120 Volts AC, Weight-15.50 ounce (oz)/ 420 grams, Manual Pull station Dual Action complete all as specified and as directed. 32.00 Supply, installation, testing & commissioning of UL Listed sounder cum storb should comply with international standards such as NFPA72 (2016 edition). Flexible optic design to meet the light dispersion, 4 candela settings:15/ 30/ 75/ 110 cd output, 2 audible tone settings- Continuous/ Temporal 3, Slim and Sleek, Light Source & Color - High power cool white LED, Pulse Duration - 20ms, Max Current Draw (mA) - (67-93mA), Flash Rate-1 flash per second, Operating Voltage : 24 Volts DC (16-33 Volts DC) / FWR, Sounder Output -(75 dB to 85 dB), Mounting Options-Standard 4” * 4” back box, Wiring - 2-Wire Type, Screw Terminals - #12 to #18 AWG wires complete all as specified and as directed. 33.00 Supply, installation, testing & commissioning of selector switch wall mounting type for main to reserve, made of ABS/ PVC material size -135 x 235 x 135 mm Type. (without mounting lugs), Switch- 2 position Latching type, Rotary Switch Model 2A S2- 2P, Switch Elements- (NO & NC) type, MOC- SS 316, 1.5mm thick, Max. Current- 2Amps, Max. Voltage- 110 Volts DC/ 220 Volts AC, Temperature Range 0°C to 54°C complete all as specified and as directed. 34.00 Supply, installation, testing & commissioning LED Display sign board ceiling/ wall mounting type EVACUATE GAS RELEASED (inside) & DO NOT ENTER (outside) , LED Display sign board is Made up of uniformly extruded, aluminum alloy. paint & Colour- Epoxy polyester powder coating, White in colour, Diffuser cum message panel- CAD Designed printing on 10 mm clear acrylic sheet Input- 24 Volts DC, LED- Multiple LEDs) complete all as specified and as directed. 35.00 M & L for preparing UL approved Flow calculations with piping isometric, Gas quantity, layout drawings, with Cylinder CCOE certificate for Storage cylinders,OEM fill certificate,Certificate for filling in India and all related documentation complete all as specified and as directed. Note:- Detailed engineering to be done by OEM and provide flow claculation report of required gas for protection area before execution of work. 36.00 Supply, installation, testing & commissioning of pipes as per flow calculations for the specific hazard volume and stand to hold, position & support the Manifold and Piping properly with fabrication work of pipes. Sch 40, ASTM A106 Grade B, total pressure 100 Bar, fittings Socket welded, thickness minimum 2.8 mm and goes high as per sizes and ASTM standarad of followng sizes complete all as specified and as directed. 36.01 15 mm dia Nominal Bore 36.02 20 mm dia Nominal Bore 36.03 25 mm dia Nominal Bore 36.04 32 mm dia Nominal Bore 36.05 40 mm dia Nominal Bore 36.06 50 mm dia Nominal Bore 36.07 65 mm dia Nominal Bore 36.08 100 mm dia Nominal Bore 37.00 Supply, installation, testing & commissioning maintenance free Battery 12 Volts, 7 Amp sealed to provide backup for control panel complete all as specified and as directed. 38.00 Supply, installation, testing & commissioning of CO2 gas cylinder of capacity 68 Ltrs suitable to fill 45 Kg CO2 Gas. Manufacturing standard- IS 7285, UL 1254, UL 2166, material 37 mng Manganese Steel, cylinder diameter- 267 mm, Cylinder Neck Thread- 3/4” NGT/ 25E, Filling Density- 0.667 Kg/ Ltrs, Maximum, Temperature Ratings (-20) ᵒC to (+) 55ᵒ C, Min Test Pressure 250 Bar, All the components attached should be UL Listed complete all as specified and as directed. Note:- First filling including Co2 gas required for filling included in item rate quoted. 39.00 Supply, installation & testing of Master Valve to operate master cylinder assembly, made of brass as per standard -UL 2127, NFPA 12, Threads-Inlet- 3/4” NGT, Outlet, 7/8” UNF, Temperature Ratings (-)18ᵒC to (+) 54.4ᵒC, Electric Operation-24 Volts DC, Test Pressure- 207 Bar complete all as specified and as directed. 40.00 Supply, installation & testing of Slave Valve to operate pilot cylinders used in multi cylinder bank made of Brass, Stainless Steel, Elastomeric material as per standard UL 2127, NFPA 12. Threads-Inlet- 3/4” NGT, Outlet: 7/8” UNF, Temperature Ratings (-) 18ᵒC to (+) 54.4ᵒC, Test Pressure- 207 Bar complete all as specified and as directed. 41.00 Supply, installation & testing of Discharge hose for gas discharge through manifold piping, made of Flexible Wire braided Rubber end Fittings of Stainless Steel as per standard UL 2127, NFPA 12. Threads- 7/8” UNF (F) x 7/8” UNF (F), Temperature Ratings (-) 18ᵒC to (+) 54.4ᵒC, Test Pressure- 180 Bar complete all as specified and as directed. 42.00 Supply, installation & testing of Check valve to install between manifold and discharge hose, made of Stainless Steel, Elastomeric Material, Threads- 7/8”UNF (M) x 3/4” BSP (M), Temperature Ratings (-) 18ᵒC to (+) 54.4ᵒC, Test Pressure- 180 Bar complete all as specified and as directed. 43.00 Supply, installation & testing of Interconnecting hose to connect pilot cylinders with master cylinder, made of Flexible Wire Braided Rubber end fittings- Stainless Steel, Threads- 3/8” BSP (M) x 3/8” BSP (M), Temperature Ratings (-) 18 ᵒC to (+) 54.4ᵒC, Test Pressure- 180 Bar complete all as specified and as directed. 44.00 Supply, installation & testing of Cylinder Battery Frame with manifold and rack support, made of Mild Steel Manifold Carbon Steel Seamless Pipe to fix cylinders and manifold in the single fabricated frame complete all as specified and as directed. 45.00 Supply, installation & testing of Safety relief valve to manage additional pressure, made of Stainless Steel, Nickel burst disc. Threads- 1/2” BSP (M), Temperature Ratings (-) 18 ᵒC to (+) 54.4ᵒC, Test Pressure (Blanked Condition)- 180 Bar, Operating Pressure 170 ± 5 Bar complete all as specified and as directed. 46.00 Supply, installation & testing of Bleeder Valve to manage additonal pressure made of Stainless Steel, Threads, 3/8” BSP (M), Temperature Ratings (-) 18ᵒC to (+) 54.4ᵒC, Test Pressure- 180 Bar, Leakage Pressure 1.4 Bar complete all as specified and as directed. 47.00 Supply, installation & testing of Pressure Switch to monitor gas discharge, made of Stainless Steel as per standard UL 2127, NFPA 12. Threads- 1/2” BSP (M), Temperature Rating (-) 18ᵒC to (+) 54.4ᵒC, Test Pressure 180 Bar, Operating Pressure ≥ 5 Bar, Electrical Ratings 15Amps/ 250 Volts, AC Max complete all as specified and as directed. 48.00 Supply, installation & testing of Discharge Nozzle to distribute agent in protection area, made of Stainless Steel as per standard UL 2127, NFPA 12,Threads- 1/2” BSP (M), Temperature Ratings (-) 18ᵒC to (+) 54.4ᵒC complete all as specified and as directed. Note:- Orifice sizes to be considered as per software calculation by OEM 49.00 Supply, installation & testing of 4 zone Gas Release Panel UL Listed, Initiating Device Circuits -All Zones are Class B Style B/C operation (Programmable), Primary Power (120 – 220) Volts AC ± 10%, 50 Hz, 2.5 Amps, Normal Operating Voltage (14 – 21) Volts DC, Alarm Current 15 - 30 m Amps, Short Circuit Current 45 m Amps Maximum, Loop resistance-100 ohms Maximum, End-Of-Line Resistor 3K9, 1/2watt, Standby Current -7m Amps (2m Amps for Detectors complete all as specified and as directed. 50.00 Supply, installation & testing of Clean agent based 2 Kg direct low pressure Firessense Automatic Fire detection and fire fighting system consisting of following complete all as specified and as directed. :-(a) Clean agent cylinder made of mild steel, Cylinder diameter 110 mm (Approx.)(b) Cylinder Neck Thread- M30 x 1.5, Height- 300 mm (Approx.)(c) Temperature Rating (-) 20°C to 60°C(d) Test Pressure- 35 bar(e) Cylinder valve made of Brass (Nickel Plated), Threads- M30 x 1.5, Temperature Ratings (-) 20ᵒC to (+) 60ᵒ C, Test Pressure- 28Bar.(f) Valve Seat- DN 6 mm, Valve Thread- 1/8” (M) x 1/8” (F). (g) Pressure gauge test pressure 28 Bar, range 0 to 28 bar, Pressure gauge Connection M10 x 1, Dial Zones-Green Zone and Red Zone 50.01 (h) Tube connector material brass, Connections- Pushfit suitable for tubing of Outer dia- 6 mm, Inner dia- 4 mm, Temperature Ratings (-) 20ᵒC to (+) 60ᵒ C, Test Pressure- 28bar. (j) End of line Connector made of Brass (Nickel Plated), Threads/ Connection- M10 x 1/ Detecting tubes 4 x 6, Test Pressure- max 28 Bar, Temperature Rating (-) 20°C to (+) 60°C. (k) Pressure Switch made of Plated Steel, Switch Type- SPST-NO, Thread Connection- G1/4”, Electrical Connections-D6.35 x 0.8, Temperature Rating (-) 30ᵒC to 9+) 65ᵒC, Test Pressure- 70 Bar.(l) Voltage Ratings- 240 Volts AC/ 120 Volts DC- I Amp. 50.02 (m) End of line Plug made of Brass (Plated), Connection-Pushfit suitable for tubing of Ø 4 x 6, Test Pressure Max. 28 Bar, Temperature Rating (-) 20°C to (+) 60°C.(n) Tee Connector made of Brass (Plated), Connections- Pushfit suitable for tubing of Ø 4 x 6, Test Pressure- Max. 28 Bar, Temperature Rating (-) 20°C to (+) +60°C.(o) Monitoring panel made of ABS Enclosure, Power Supply- 230 Volts, 50 Hz, AC, Indication- GREEN LED: System Healthy RED LED, System Discharged Buzzer- Sound on when system is discharged, Temperature Rating- (-) 20°C to (+) +60°C 51.00 Supply, installation & testing of Heat detection tube made of modified polyamide (PA), Inner diameter- 4mm, Outer diameter- 6mm, Operating Temperature- 137.8 ºC to 148.9 ºC, Installation Temperature- < 120ºC, Bend Radius- Min 100 mm, Tube should be UL Listed with all necessary fittings & supports complete all as specified and as directed. 52.00 Supply, installation & testing of DC convertor for Panel protection power supply to convert AC power into DC complete all as specified and as directed. 53.00 M&L for point wiring with 2.5 Sqmm, PVC insulated, unsheathed, multistranded copper conductor single core FRLSH cable, IS-694 marked, drawn through and including heavy duty PVC rigid conduit,ISI marked complete with all ISI Marked accessories such as socket, elbow, junction box, etc including provision of ISI marked and PVC modular box, covered with modular white cover plate with frame suitable modular swiches including PVC insulated multistranded copper conductor 2.5 Sqmm (nominal area) single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly all as complete specified 54.00 S & F modular switch 1 way 16A, 1 module, one way all as specified and directed. 55.00 S&F modular socket 6A/16A - 2/3 pin combined 2 module all as specified and directed.