Tender For Spl Repair To Bldg Tr-124,Tr-136 And Tr-137 Within Aor Of Age B/R-Ii At Pallanwala Mil Stn Under Ge South Akhnoor.; 1 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and as directed . 2 Dismantling wrought iron or mild steel work/ structural steel work of any description not otherwise provided for ,complete all specified and directed. 3 Dismantling asbestos cement corrugated,semi-corrugated ,etc roof coverings including ridge ,complete all specified and directed. 4 Demolition of cement concrete un-reinforced in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed. 5 Demolition brick work or stone/boulder masonry built in cement mortarincluding all quoins, arches, pillars etc but excluding ashlars facings, dressed stone work and precast concrete articles ,complete all specified and directed. 6 Taking down cement plaster from brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc.,complete all specified and directed. 7 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth , for manhole,pipe line,cables, foundationetc not exceeding 10.00 sqm on plan and getting out in any type of soil,complete allas specified and as directed . 8 Returning filling including spreading levelling watering and well ramming in layers n.exc 25cm in soil, complete all as specified and as directed . 9 Removing excavated material (soils) not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point, complete all as specified and as directed . 10 S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified & directed . 11 S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall,fixed with self tapping screws ,complete all specified and directed. 12 Dismantling wall and ceiling boards (fibre, pulp, insulation etc), or insulation boards/slabs/blankets, any thickness any type including cover fillets, complete all as specified and directed. 13 Providing and fixing ceiling board of 4mm thick, designer, in ceiling fixed as per manufacturer’s instructions, including powder coated galvanised iron snap grid frame work of main and tee (weight not less than 240gm/Rm), angle (weight not less than 217 gm/Rm), grid size 595x595mm, for false ceiling all as specified, and hangers not less than 3mm nominal dia, galvanised iron (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of galvanised iron wire of 2.0mm dia, length as required at site and expansion hold fasteners 12.50mm dia, 40mm long ,complete all specified and directed. 14 All as per item 13 here-in-above but fixing only (material obtained from Srl. Item No. 12 to be used) 15 S&F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, confirming to grade Fe 410-W (Gde E-250 quality-A),complete all as specified and directed. 16 All as per item 15 here-in-above but fixing only (material obtained from srl. Item no.02 to be used) 17 M&L for plain cement concrete 1:2:4, type B-1 using 20 mm graded crushed stone aggregates as in hold fasts,copings, bed plates, kerbs, water troughs and the like includingweathering, slightly rounded or chamfered angles and throating, including necessary formwork , complete all as specified and as directed. 18 S&F TMT bars of 5mm dia and over upto and including 10mm dia in stirrups,spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.,complete all as specified and as directed. 19 S&F TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.,complete all as specified and as directed. 20 S&F in repair curtain rod, 20 mm dia stainless steel fixed with brakets,stops,rollers etc , complete all as specified and as directed. 21 M&L for 75 mm thick plain cement concrete 1:3:6, type C-2 (using 40 mm graded crushed stone aggregate) as in sub base finished even and fair including necessary formwork , complete all as specified and as directed . 22 M&L for machine pressed precast concrete interlocking paver block of any size and shape confirming to IS 15658-2006 of 60mm thickness M-35 grade,including 25mm sand cushioning ,complete all as specified and as directed 23 M&L for 25 mm thick plain cement concrete 1:2:4 type B-2 using 20 mm graded crushed stone aggregates as in sub bases of floors and pavings etc.including necessary formwork ,complete all as specified and as directed. 24 M&L for reinforcement cement concrete,(nominal mix) type B-1,1:2:4(20 mm graded crushed stone aggregatge) for Chajjas/ Balcony/ Landing work/kitchen slab etc., complete all as specified and as directed. 25 M&L for formwork to flat finished surface of concrete to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, chajja, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc., complete all as specified and as directed . 26 Providing and laying at or near ground level factory made kerb stone of M-25 (Design mix) grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required ,complete all as specified and as directed . 27 M&L for brick work with sub class `B bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 ,complete all as specified and as directed . 28 M&L for brick work with sub class `B bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6, but except bricks,complete all specified and directed. 29 Rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces using water proofing compound , finishing the surface even & smooth without using extra cement, complete all as specified and as directed .Note:- Cost of Water proofing compound shall be deemed to included in quoted rate. 30 Rendering 10 mm thick in cement mortar 1:6 onany surfaces of brick work, finishing the surface even & smooth without using extra cement,complete all as specified and as directed . 31 M & L for non-skid, coloured tiles of size 600x600 mm 7 to 08 mm mm thick of , set and jointed in neat cement slurry (3 Kg cement per Sqm) and pointed in white or coloured cement to match over screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in cement mortar 1:4,complete all specified and directed. 32 M & L non-skid,joint free, coloured tiles of size 600x600 mm 7 to 08 mm mm thick, as in skirting set and jointed in neat cement slurry (3 Kg cement per Sqm) and pointed in white or coloured cement to match shade of tiles over 10 mm thick rendering in cement mortar 1:4on other than fair faces of brick work ,complete all specified and directed. 33 M&L Glazed ceramic coloured/shaded tiles of any design/pattern approved in vertical surface of size 450X 350X 7mm thickset and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles over 10 mm thick rendering in cement mortar 1:4 on other than fair faces of brick work ,complete all as specifed and directed. 34 Taking down chowkat or frame exceeding 1.5 sqm but not exceeding 4 sqm each with shutters (without taking off shutters from the frames),complete all specified and directed. 35 Taking down chowkat or frame not exceeding 1.5 Sqm each with shutters (without taking off shutters from the frames),complete all specified and directed. 36 S&F pressed steel frame of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. ,complete all specified and directed. 37 M&L forplain cement concrete 1:3:6 type C-0 using 12.5mm graded crushed stone aggregate as in back filling of steel chowkhat single or double rebated or for fixing ,complete all as specified and directed. 38 S&F 30 mm thick 2nd class hard wood plain, framed, panelled shutter (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered particle board, medium density, wood particle board with commercial face veneered supplied & fitted to chowkat ,complete all as specified and directed. 39 S&F factory made, glazed and skeleton shutters in second class hardwood, 35mm thick, open rebated and prepared to receive glass, gauze etc. in 3 panels) with sash bars, edged of framing plain, chamfered or rounded. Fitted with cut and mitred beads for securing glass including galvanized mild steel wire cloth, 0.46mm nominal dia of wire and average width of aperture 1.18mm etc.; sizes of members of shutters as specified in SSR Part-l Section 8 clause 8.24 (a); supplied and fitted to chowkhats, complete all us specified and as directed. 40 S&F factory made steel window/Ventilator, box type, using ERW hollow P section, comprising double frame for and including gauged and glazed skeleton shutter with wire mesh and glass sheet 3.0mm thick, 4mm thick frosted glass jointed internally and made with flat iron 40x4mm complete including grill/ guard bars of 8mm square bars fixed horizontally @100mm C/C including mild steel hinges, handles, tower bolts, stops, lugs etc, complete all as specified and as shown in drawing No- CEUZ/TD/1517/15, sheet No- 1/3 to 3/3. Note :- Cost of all items/elements eleborated in the specification and in Drawing shall be deemed to inlcude in quoted rate. 41 M&L for mild steel square bar framed work such as in grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; staging for of water tanks, cooler stand and similar work conforming to Fe-290, Gde-E-165, including cutting and welding, complete all as specified and as directed. 42 Writing letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high , complete all as specified and as directed. 43 Writing Stops, commas, short lines, dashes, hyphens, brackets, etc, complete all as specified and as directed. 44 S&F150 mm long Extruded aluminium alloy handle, cast type, anodised ISI marked , complete all as specified and as directed. 45 S&F 200 mm long aluminium, anodised, barrel tower bolt of extruded section ISI marked , complete all as specified and as directed. 46 S&F 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed , complete all as specified and as directed. 47 S&F mild steel spring for doors, 300mm, ordinary rat tail rod pattern springs including roller and roller plate, ISI marked, complete all as specified and as directed. 48 S&F floor door stopper 140mm overall length of cover plate of aluminium alloy body and tongue,anodised,with hard drawn steel spring, ISI marked fixed in bottom body of door complete all as specified and directed. 49 S & F granite of any type (table rubbed and polished) 15-18 mm thick ,as in steps, jambs, pillars, window/ ventilator-cills,cooking platform,urinal partition and like including screed bed 20mm thick in cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite , complete all as specified and as directed. 50 M&L for 50mm thick, plain cement concrete M-10(1:3:6), type C-1 (using 20mm graded crushed stone aggregate),as in plinth protection and providing the joints throughout the thickness, filled with mastic filling comprising bitumen 85/25 grade and sand mixture 1:3 by weight,including necessary formwork , complete all as specified and as directed. 51 M&L for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat chalk whiting, on plastered surfaces,preparatory to distempering, over two coats of wall care putty, complete all as specified and as directed . 52 M&L for preparation of old plastered surfaces of walls including complete removal of existing treatment and applying two coats of distemper oil emulsion over one coat chalk whiting, on plastered surfaces,preparatory to distempering, over two coats of wall care putty, complete all as specified and as directed .. 53 M&L for applying one coat of synthetic enamel paint including preparation of old or previously treated steel surfacesover 10 cm in width or girth , complete all as specified and as directed. 54 M&L for applying two coats of synthetic enamel paint over a coat of pink primer on wooden surface over 10cm width or girth including preparation ofnewuntreated surface complete all as specified and directed. 55 M&L for applying two coats of synthetic enamel paint over a coat of zinc chrome/red oxideprimer including preparation of new or previously untreated steel surfacesover 10 cm in width or girth , complete all as specified and as directed. 56 M &L for preparation of new surfaces of walls plastered surface, priming with alkali resistant primer and applying two coats of exterior emulsion paintin camouflage pattern , complete all as specified and as directed. 57 M&L for complete removal of exiting treatment from old plastered wall surfaces,applying two coats of Emulsion paint over one coat of primer, complete all as specified and as directed . 58 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.to match with existing surface ,colour ,shade with putty and white cement for smooh finishing of holes ,small patches etc, complete all as specified and as directed . 59 Material and labour for point wiring (IN NEW CONCEALED CONDUITS TO SURFACES) complete with 1.5 sqmm PVC insulated, FRLS type, ISI marked,conforming to IS-694/1990 unsheathed,multistranded,single core,copper conductor cable 1100 volts grade colour code drawn through and including PVC conduit 20 mm dia medium grade (MMS) including cutting, chasing work at any height and all accessories to be concealed in walls/roofs/floors/ceiling etc. flush mounting MS box with top,bottom,side/back wall, knockout for conduit with entry from any direction made out of 1.20mm thick suitable for fixing of housing of switch module for switch,socket,fan regulator,red colour indicator, blank plate etc as approved coloures including 1.5 Sqmm PVC insulated multistranded FRLS type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly,complete all as specified and directedfor the following:- (Note:- Allnecessary accessories such as box,top cover, plate, blank plate,MS box,screws,washers and all electrical fixtures are to be used of same make/brand only ) 60 (a) One light point/fan point/ exhaust fan point/ bell point controlled by one switch ,complete all as specified and as directed . 61 (b) One 5 pin 6 amps socket point controlled by one 6 amps switch on same board,complete all as specified and as directed . 62 (c) One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board,complete all as specified and as directed . 63 Description all as per item No 59.00above, but point wiring with 4.0 sqmm and earth conductor of size 4.0 sqmm complete all as specified and directed but for One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on independent boardcomplete all as specified and directed . 64 Supply and fixing switch modular type, single pole, one way, 6 Amps, complete all as specified and as directed. 65 Supply and fixing switch socket,modular type,6-pin, 6/16-Amps, 3 module ,complete all as specified and as directed . 66 Supply and fixing modular socket ,type,3-pin, 6-Amps,2 module ,complete all as specified and as directed . 67 Supply and fixing fan regulator,modular type,2-module, 100-120-Watt ,complete all as specified and as directed . 68 Supply and fixing ceiling rose, three phase/ PVC/ polycarbonate, isolated body type,3 terminals complete all as specified and as directed . 69 Supply and fixing white cover plate with frame,8 module, complete all as specified and as directed . 70 Supply and fixing white cover plate with frame,2 module, complete all as specified and as directed . 71 Supply and fixing white cover plate with frame,3 module, complete all as specified and as directed . 72 Supply and fixing in repair LED tube light fitting, 20 watt, 4 feet long indoor decorative high lumen batten, including connecting up with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to fitting ternimal, complete all as specified and as directed . 73 Supply and fixing lamp holder, PVC Polycarbonate type with back plate suitable for batten fittings , complete all as specified and as directed . 74 Supply and fixing in repair LED secruity light fitting of capacity 60 Watt in aluminium PDC housing, toughened glass cover with IP66 protectionwith suitable inbuilt surge protector with bracket made of GI pipe 40mm dia light grade 1.0 mtrs long duly cut and welded at an angle of 120 degrees and fixed to wall with 50mm X 6mm MS clamps-02 nos with 16mm dia bolts,nuts and washers, complete all as specified and as directed . 75 Labour only for taking down and refixing/hanging ceiling fan (M.D. supply) with replacement of 3 core multistranded copper conductor cable of size23/0.193 from ceiling rose to fan ternimal,complete all as specified and directed. 76 Supply and fixing in repair sheet metal enclosures DBs double door factory made power coated out of CRCA mild steel sheet 1.2 mm thick with metallic painting white series, 240 volts 200 amps rated enamelled bus bar 12 way dust and vermin proof proof suitable for incorporation of MCBs duly concealed in walls and making good to disturbed surface and colour matching,complete all as specified and directed. 77 Supply & fixing MCB SPN 40 Amps 10 KA,B series, AC, 240Volts, 50Hz, ISI marked,complete all as specified and directed. 78 Supply & fixing MCB SP 6 to 32 Amps 10 KA,B series, AC, 240Volts, 50Hz , ISI marked,complete all as specified and directed. 79 Supply and laying of well burnt bricks, sub class B laid flat with width equal to length in trenches for protection of cable,complete all as specified and directed. 80 M & L for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches ,complete all as specified and directed. 81 Supply,laying, connecting and testing 1100 volts grade,10 sqmm,2.0 core, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape ,complete all as specified and directed.(Note : 1.Excavation, earth work, bricks protection and sand cushioning will be measured and paid separately). 82 Material and labour for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres belowground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipeof 15 mm diafrom earth electrode up to test point or up to 7.5mtr whichever is less by means of GIbolts, nuts, check nuts and washersall as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM, RCC cover 1:2:4 type B1 of size 45X45X6CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required valueincluding removing old unserviceable earthing items, completeall as specified and directed.