Tender For Spl Repair To Bldg No A/8/191, Provn Of Guard Post And Room With Attached Toilet And Bath And Provn Of Footh Path From Wellness Clinic To Lao Office In The Aor Of Age Br-Ii Under Ge Panagarh., panagarh-West Bengal

Military Engineer Services has published Tender For Spl Repair To Bldg No A/8/191, Provn Of Guard Post And Room With Attached Toilet And Bath And Provn Of Footh Path From Wellness Clinic To Lao Office In The Aor Of Age Br-Ii Under Ge Panagarh.. Submission Date for this Tender is 25-07-2025. Building Work Tenders in panagarh West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

50021235
Tender For Spl Repair To Bldg No A/8/191, Provn Of Guard Post And Room With Attached Toilet And Bath And Provn Of Footh Path From Wellness Clinic To Lao Office In The Aor Of Age Br-Ii Under Ge Panagarh.
Tender
Indian
West Bengal
Panagarh
25-07-2025

Tender Documents

Tender Details

Tender For Spl Repair To Bldg No A/8/191, Provn Of Guard Post And Room With Attached Toilet And Bath And Provn Of Footh Path From Wellness Clinic To Lao Office In The Aor Of Age Br-Ii Under Ge Panagarh.; 1 Surface excavation n.exc.30 cm deep andaveraging 15 cm deep and getting out in soft/loosesoilincluding clearing away all grass vegetation, saplings, shrubs, brush wood, under growth, roots and trees n. exc. 30cm girth and removing rubbish upto a distance of 50 metre out of the periphery of the area completeall as specified and as directed. 2 Exacvating over areasn n. exc 1.5m deep and getting out in soft/loose soil complete all as specified and as directed. 3 Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soilNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. 4 Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed. 5 Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 6 M&L for filling with mix of flyash, clinker & stone dust in the proportion of 1:3:6 (ie 10% fly ash, 30% clinker and 60 % stone dust) laying in layers n. exc 100mm thick, watering, ramming and compacted with vibratory/ power roller 8 to 12 tonn roller to required camber and gradient complete all as specified and as directed by Engr-in-Charge, laid in layers n. exc 15cm thick, spread, levelled and blinded with earth and rammed including watering complete all as specified and as directed. 7 M&L Sand filling under floors or in foundations including watering and consolidaion, all as specified and as directed. 8 M&L for Hardcore using Broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, all as specified and as directed. 9 Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as sepcified and directed. 10 Demolition of cement concrete reinforced as in ground floors and pavings not exceeding 15 cm thick below or above ground level complete all as specified and directed. 11 Demolition of cement concrete as in ground floors and pavings not exceeding 15 cm thick below or above ground level (unreinforced) complete all as specified and directed. 12 Dismantling framed trusses span n exd 10 mtr complete all as specified and directed. 13 Dismantling (corrugated,semi corrugated ) sheet in roof covering complete all as specified and directed. 14 Dismantling of building board of any discription fixed in any position complete all as specified and directed. 15 Taking down window chowkhats or frame not exceeding 1.5 Sq. m each with shutter(s) (without taking off shutters from the frame), including removing to store, completeall as specified and as directed. 16 Taking down chowkhats or frame exceeding 1.5 Sq. m but not exceeding 4 Sq. m each with shutter(s) (without taking off shutters from the frame), including removing to store, completeall as specified and as directed. 17 M&L for Plain cement concrete type D2 1:4:8 (using 40 mm graded stone aggregate) as in foundation and mass filling, completeall as specified and as directed. 18 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including marking joints with or without grooves (thickness of joints except at sharp curve shall not more that 5mm), including making drainage opening wherever required complete as specified and as directed. 19 M&L for providing reinforcement cement concrete M-25 (Design Mix) as in footing, foundation,beams, plinth beams, base for columns and mass concrete complete all as specified and directed. 20 M&L for providing reinforcement cement concreteM-25 (Design Mix)as incolumns complete all as specified and directed. 21 M&L for providing reinforcement cement concrete M-25 (Design Mix) as in chajja complete all as specified and directed. 22 M&L for M-25 Design mix using 20mm stone aggregateBeams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. 23 M&L for providing reinforcement cement concreteM-25 (Design Mix)as inSlabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed. 24 M&L for damp proof course 40mm thkM-20 (Nominal Mix) using 12.5mm graded stone aggregate with water proofing compound conforming to IS-2645 liquid grade as per manufacturer’s instructions with and including polythene film 200 micron over and including 85/25 grade Industrial bitumen (IS-702 : 1988) @ 1.5 kg/sqm blended with the dry sand @ 0.05 cubic meter/ sqm. complete all as specified and directed. 25 M&L PCC (1:2:4) type B1 as inkerbs incl necessary form work (cast in situ) etc complete as directed. 26 M & L for cement concrete 1:3:6, Type C-1 (Using 20 mm graded stone aggregates) in surface channlels and drains complete all as specified and directed 27 M & Lfor forming fair finish drain channel 45 cm inner grith in cement concrete using extra cement, complete all as specified and as directed. 28 M&L for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc all as specified and as directed.. 29 M&L forfly ash brick old size straight or curved on plan exc 6 mtr mean radius built in CM 1:6 ,including demolition of brick work built in cement mortar including all quoins, arches, pillar etc all as specified and directed. 30 M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter complete all as specified and directed. 31 M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of pillers, posts, struts, pier, columns and stanchions complete all as specified and directed. 32 M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides and fair finish soffits of floor or roof beam,beam hauchings, girders, bressum-mers, lintels cantilever, shelves including supports, overhangs, etc also splays between floors and beams etc complete all as specified and directed. 33 M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to chullah hoods, chajjas, troughs and similar fair finish items including edgges complete all as specified and directed. 34 M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; n.exc. 200mm thick (Horizontal or sloping) fair finished surfaces of concrete flat complete all as specified and directed. 35 M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50X100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardan and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.edepth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. 36 S&F Factory made single extruded WPC (Wood Polymer Composite) solid decorative panelled decorativeflush door shutter one side plain on other sideof 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) complete all as specified and as directed. 37 S&F factory made single extruded WPC (Wood Polymer Composite) wire gauzed i.e. panel will bewire mesh in lieu WPC , the wire gauze shall be warped on additional square 8mm MS Solidtube and this tube shall bewelded to MS frame complete all as specified and as directed. 38 Solid PVC Door frame of size 50mm x 47mm made out of 5mmPVC sheet reinforced suitable for solid PVC door suppling & fixing in opening, completeall as specified and as directed. 39 Material and labour for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made outof MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC “C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side &as gap insert for top rail & bottom rail includning butt hinges completeall as specified and as directed. 40 S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples completeall as specified and as directed. 41 S&F butt hinges, extruded alluminium,with mild steel hinge pin,bright polished and fixed, type 100 mm size B21 complete all as specified and directed. 42 S&F 150 mm long aluminium alloy handles,fabricated type, anodised complete all as specified and directed. 43 S & F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed completeall as specified and as directed. 44 S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and slidibg bolts of extruded section or cast-aluminium alloy. 45 S&F Drapery rod (conduit) of dia not less than 25 mm having a corrugated virgin PVC extrusion on it& finials of approved shade with standard MS powder coated/ brackets, fixed to walls with rawl plugs and steel screws complete all as specified and directed 46 S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows,ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at nctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.Pbrass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief 47 S&FPowder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-chargeher for openable/sliding shuttters) including all necessary fittings as directed 48 M&L Mild steel TMT bars 10 mm dia & over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. 49 Ditto but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. 50 M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe-410-W(Gde- E-250) quality-B complete all as specified and directed. 51 M&L Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; complete all as specified and directed. 52 M&L framed work such as grills ,grating,etc,with ends of bars shouldered and or riveted or forged into spike ;framed guard bars for windows and iron gate conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed. 53 M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated of any profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified up to anyheight including all necessary scaffolding and safety measurescomplete all as specified and directed. 54 M & L forpre-paintedhot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specifiedany heightMtr height including all necessary scaffolding and safety measurescomplete all as specified and directed. 55 M&Lfor grading roof in cement mortar 1:3,25mm thick in edge and 50mm thick in ridge including necessary curing complete all as specified in SSR Part I clause No 11.42.2 56 M & L for providing water proofing treatment with a layer of APP based polymeric membrane, 3 mm thick (minimum), weighing not less than 3.60 kg/Sqm reinforced with polymer non woven fabric (weighing not less than 160 gm/ Sqm) shall be applied over and including one coat of cold bituminious primer @ 0.40 ltr/ Sqm ( membrane shall be laid using butane torch and sealing all joints etc, complete all as specified and directed .( Note: The overlaps shall be of minimum 75 mm on longitudinal direction and 100 mm on transversedirection) complete all as specified and directed. 57 M&L for preparing surfaces of roof and applying one coat ofaluminiumPaint complete all as specified 58 S&F in for 4 mm thick non asbestos fibrecement designer buildingboardsfixed or laid/ inserted to timber/GI / Aluminium frame work with screw fixed in ceiling flat or sloping including hangers 4 mm dia GI (up to 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long including anodised aluminium snap grid 605 x 605 mm frame work complete all as specified. 59 M & L Green marble work 15 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of following typesnt with admixture of pigment to match the shade of granite stone including grinding and polishing complete over 15mm thick Screed bed or backing coat for laying floor finishes in CM 1:6 complete all as specified and directed. 60 M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.® complete all as specified and directed. 61 M&L 75 mm cement concrete type B1 (1:2:4) using 20mm graded aggregateas in receiving floor finished complete all as specified and directed. 62 M & L for cement concrete 75mm thick 1:4:8, Type D-2 (Using 40 mm graded stone aggregates) as in sub base for flooringetc complete all as specified and directed. 63 M&L40 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in roof padding, finished fair and even without using extra cement from roof surfaces complete all as specified and directed. 64 Material and labour for non skid ceramic tiles coloured 7 to 8 mm thick(square/rectangular) area of each tile exc 0.06 sqm but not exc 0.11 sqm, in floors etc, set and jointed with neat cement slurry and pointed in white or coloured cement with pigment to match the shade of tiles over and including 15mm thick screed in cement mortar (1:6) complete all as specified and directed. 65 M&L for Non Skid ceramic colouredtiles 7mm to 8mm thick, (square or rectangular) area of each tile exc 0.18 Sqm but n. exc 0.38 sqm in floors etc , over & including 15 mm thick cement mortar (1:6) screed etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, 66 Material and labour forGlazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to matchand including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed. 67 M&L for Chequered Cement concrete tiles 20cm x 20cm x 25mm thick, set jointed and pointed in neat cement slurry in floors over 15mm thick screed bed in cement mortar 1:6, with grey cement and pigment complete all as specified and directed. 68 M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade, with grey cement and pigment, all as specified and as directed. 69 M&L for cement concrete type C2 1:3:6 (40mm graded aggregate) 75mm thick as in plinth protection finished even and smooth without using extra cement, incl making joints 10mm wide to the full depth of PCC at every 3 meters and at every change of direction and filling the same with and including bitumen and sand 1:3 by weight complete all as specified and directed. 70 M&L for rendering 15 mm thickon other than fair faces of brick work or concrete surfaces, finished fair and even on walls in cement mortar (1:6), complete all as specified. 71 M&L Rendering 15 mm thick cement plaster in CM 1:4 on external fair faces of brick/concrete work surfaces finished fair and even with usingWPC (WPC will be measured and paid separately) complete all as specified and directed. 72 Rendering 5 mm thickon fair faces of concrete surfaces, finished fair and even on ceiling/chajja in cement mortar (1:3), complete all as specified complete all as specified and directed. 73 Supply only liquid water proofing compound completeall as specified and as directed. 74 M&L for three coats of white washing on newceiling/chajja surfaces including preparation ofcomplete all as specified. 75 Material & Labour for preparation of new surfaces of plastered walls and applying Twocoats ofDistempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification. over and includinga coat of primerover plastered surfaces of walls to prepare the surface even and smooth complete all as specified. 76 Material & Labour for preparation of new surfaces of plastered walls and applying Twocoats ofDistempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification. over and includinga coat of primer with 1.0 mm thick white wall care putty (premiumquality) over plastered surfaces of walls to prepare the surface even and smooth complete all as specified. 77 Material and labour for treatment of wall &applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004 , alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives@ 1.43 litre/10sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as specified and directed. 78 S&F 4mm thick figured sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading )in square n.exc 0.5 Sqm in each panes complete all as specified. 79 M&L for preparation of concrete kerb stone or plaster surfaces of any description not otherwise described over 10cm width or girth and applying two coat of water based floor paint over one coat of priming paints plaster coat complete all as specified and as directed. 80 M&L for two coats of synthetic enamel paint over & including a coat of red oxide primer over new steel & iron surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified and directed 81 M&L for steel tubes,15mm dia bore medium grade with all fitting; laidin wall and ceiling complete all as specified and directed. 82 S&F Bib taps, cast copper alloy with handle, chromium plated fancy type,with wall flange screwed down, suitable for 15 mm bore pipe complete all as specified and directed. 83 M&L for PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement etc complete all as specified and directed. 84 Supply and fixPVC (SWR) pipes 110mm bore single socketed, in any length with ruber ring joints laid in trences or in floors complete all as specified and directed. 85 S & F 110mm bore PVC(SWR) bends any radius complete all as specified and directed. 86 S&F 10 litre capacity two way flash PVC low level flushing cisternwith all accessories complete fixed with WC including syphone pipe, PVC flushing pipe of size complete all as specified and directed. 87 S & F vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. 88 S&FVitreous china wash basin, white, flat back, size 550x400mm excluding taps,chain and plug and porcelain stopper butincluding brackets, CP waste coupling and 32mm bore GI pipe light grade complete all as specified and as directed. 89 S&F PVC connection pipe 15mm size & 450mm long with cromium plated brass coupling on both ends suitable for 15mm bore steel tubing complete all as specified and directed. 90 S&F Cast copper alloy, chromium plated long neck pillar cock fancy type, suitable for 15 mm bore pipe,complete all as specified and directed. 91 S & F CP Stop valve, any description, suitable for 15mm bore pipe ascomplete all as specified complete all as specified and directed. 92 Supply and fixing beveled edged looking mirror of size 600mmx450mm of selected quality mounted on chromium plated brass screws and cup washers to wall ,complete all as specified and directed. 93 S&F Cast iron P or S trap, ISI marked, suitable for 100 mm bore CI spun pipes , complete all as specified. 94 S&F Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed. 95 S&F CP Swivel showerarm 15mm size,195 mm long with bend of 45 degree with flange of fixing with 15mm pipe (Minimum weight 40 gm) complete all as specified complete all as specified and directed. 96 Grating with or without hole of PTMT (minimum weight 40gm) and fitting of shade matching to tiles/floor fixed with white cement including matching shade pigment complete all as specified. 97 S&Fofconcealed stop cock, fancy type 15mm bore, chromium plated complete all as specified and directed. 98 S&F Vitreous china urinal, half stall type, white (excluding flushing cistern, flush pipe) including urinal spreader of PTMT any colour for fixing with 15mm dia pipe. (Minimum weight 60gms) and including waste pipe complete all as specified and directed. 99 M&L for 10 Users On site LLDPE septic tank of capacity not less than 2000 Ltr designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for, complete all as specified and directed.(2000Ltr) 100 M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2 M dia X 1.5 M effective depth as per CEs drawings complete all as specified and directed. 101 Supplying and laying of PVC underground drainage sewer system pipe bearing 160 mm dia SN 8 including jointing with couplar, bend tee as per site requirement complete laid in trenches or floors complete all as specified and directed. 102 E/M PORTION Taking down carefully aluminium/Copper conductor point wiring (light , fan, socket or powr) complete including fittings such as switches, ceiling rose, pendents, regulators sockets etc and removing (except those to be reused shall be kept in safe custody at the site) andmaking good disturbed surfaces of walls, floors etc tomatch with the existing completeall as specified and directed. 103 M & L for concealed point wiring for fan/light point controlled by one one way switchcomplete with 1.5 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red/yellow/blue wires for phases and black wire for neutral),drawn into and including non metalic PVC rigid conduit medium grade of suitable size and conduit accessories fixed on wall, floor, roof etc. and including PVC FRLSH insulated 1.5 sq mm copper conductor for earth continuity (Green Colour)and connected to common earth dollyincluding sunken in GI terminal box2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets ect.Note : a) Note :- Cost of PVC conduit, cutting chases of wal/ceilingl, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surfaceare deemed to be included in the quoted rate. 104 All as per item No. 103.00here-in-before but5 Amp socket on same boardwith other switches. 105 All as per item No103.00 here-in-beforebut using 2.5 sqmm FRLSH PVC insulated unsheathed multi strand copper cable (1100 V) for line conductor and 2.5 Sqmm FRLSH PVC insulated unsheathed solid copper cable (1100 Volts) for earth continuty wire for onemulti socket out let power point on independent board. 106 All as per item No103.00 here-in-beforebut using 4.0 sqmm FRLSH PVC insulated unsheathed multi strand copper cable (1100 V) for line conductor and 4.0 Sqmm FRLSH PVC insulated unsheathed solid copper cable (1100 Volts) for earth continuty wire for onemulti socket out let power point on independent board. 107 Supply and fix switch piano flush type, single pole , 5/6 Amps, one way complete all as specified. 108 Supply and fix switch socket combination 2 in 1 multipurpose5 pin , (6 Amps ) flush typecontrolled by one switch complete all as specified. 109 S&Fsocketoutlets 2 in 1, 5 pin, 5/6 Amps flush type230/240 V complete all as specified and as directed .( For Same Board only) 110 Supply and fixed switch socket combination5 in 1 , 6 pin , (5/16 Amps ) flush typecontrolled by one switch complete all as specified. 111 Supply & fix ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified. 112 Supply & fix stepped type electronic fan regulator flush type 240 Volts, 120 watt, ISI marked complete all as specified . 113 Supply and fixing for concealedtype sub main wiring with two run of 4.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and includingthrough Rigid non-metallic PVC conduit(medium) ISI marked of size 25mm bore with all fittings like tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxesetc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc.including one run of 4.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified.Note : (i) Note : 2 runs of line conductor,one run of earth continuity conductor, one run of PVCconduit shall be measured as unit length. (ii)Cost of PVC conduit, conductors,making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. 114 Supply and fixing for concealedtype sub main wiring with two run of 6.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and includingthrough Rigid non-metallic PVC conduit(medium) ISI marked of size 25mm bore with all fittings like tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxesetc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc.including one run of 6.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified.Note : (i) Note : 2 runs of line conductor,one run of earth continuity conductor, one run of PVCconduit shall be measured as unit length. (ii)Cost of PVC conduit, conductors,making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. 115 Supply and fixing lamp holder, PVC/polycarbomate type with back plate straight of angle suitable for LED lamp complete all as specified and directed. 116 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC). 117 Supply & fixingLED flood light 70 watt (Min) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with BIS approved driver and lamp, Aluminum die cast housing High efficiency long life LED package in integral module with lumen efficacy of 120 lm/W (Min) and viewing angle of 45 degree to ensure better uniformity, electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test as perlatest IS. operational voltage of 170 volts to 270 volts, frequency of 50 Hz,protection grade IP 66, IK-08 CRI greater than or equal to 70%, CW available CCT of 5700K/6500K, power factor of minimum 0.95 , life span of minimum 50000 working hours cincluding necessary electrical connections by PVC sheathed copper conductor wireof 3 core x 1.5 Sqmm and necessary fixing arrangement all as specified.Note : (i) The minimum requirement of lumen efficiency, lumen output and power consumption has been specified. However,as per availability, the bidders may opted higher specification with out any extra cost. The quoted rate is deem to be included for that and no extra payment will be made on this account. (ii) The fittings should be marked Date of installation and Date of Procurement with marker pen 118 Supply & fixingLED security light 35/36 watt (Min) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with BIS approved driver and lamp, Aluminum die cast housing High efficiency long life LED package in integral module with lumen efficacy of 115 lm/W (Min) and viewing angle of 45 degree to ensure better uniformity, electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test as perlatest IS. operational voltage of 170 volts to 270 volts, frequency of 50 Hz,protection grade IP 66, IK-08 CRI greater than or equal to 70%, CW available CCT of 5700K/6500K, power factor of minimum 0.95 , life span of minimum 50000 working hours cincluding necessary electrical connections by PVC sheathed copper conductor wireof 3 core x 1.5 Sqmm and necessary fixing arrangement all as specified.Note : (i) The minimum requirement of lumen efficiency, lumen output and power consumption has been specified. However,as per availability, the bidders may opted higher specification with out any extra cost. The quoted rate is deem to be included for that and no extra payment will be made on this account. (ii) The fittings should be marked Date of installation and Date of Procurement with marker pen 119 S&F in repairs LED 20 Watt tube light fittingintregatedtype, includingLED retrofit tubelamp 20 W , LED tube light nominal power 20 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours and LED batten with aluminium housing and polycarbonate diffuser complete fittingincluding connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fittingcomplete all as specified & directed..Note (i) Make of batten and LED tube lamp should be of same make. 120 Taking down existing panel light fitting any type (600 mm x 600 mm) recess mounting/surface and S&F LED light fitting 35/36 watt recess mounting of size 600 mm x 600 mm , , LED wattage of minimum 3 watt each and Maximum 5 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz,lumen efficacy of minimum 115 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, ITHD below or less than 15%, CW available CCT of 5700K, power factor of minimum 0.95, CRCA powder coated white after phosphochromate treatment housing, life span of minimum 50000 working hours including making electric connection from source with PVC sheathed copper conductor wire of 1.5 Sqmmx 3 core complete all as specified and directed by EIC. 121 S & F in repairs sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 8 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, Ik09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match asthe existing withall as specified and directed . 122 S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, Ik09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match asthe existing withall as specified and directed . 123 Supply and fixed inMCB TPN 40 to 100 Amps,C Curve 10kA, 415 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed engr-in-charge. 124 Supply and fixed MCB SPN 40 to 63 Amps,C curve 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. 125 Supply and fixed MCB SPN 32 Amps,C curve 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. 126 Supply and fixed MCB SP 6-32 Amps,C curve 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. 127 Supply only ventilating metalic body exhaust fan380 mm sweep 230 volt AC, complete with louver and all accessories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing arrangement to wall connected with twin core twisted flexible copper conductor (23/.0076) of suitable size all as directed. 128 Material andlabour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mmmm buried directly in ground (Earthpit not less than2.25m below ground level) with top edge of theplate not less than 1.5m below normal groundlevel, connected to GI wire 4 mmasearth lead by means of bolt, nuts, check nutsandwashers of galvanised iron or steel, upto 7.5mlength, earth strip protected by andincluding 15 mm diaGI pipe (light grade) andconnected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC(1:3:6)type C1 , Precast RCC(1:2:4)TypeB1 coverslab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100mm C/C bothwayswith onehandle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm boreGI Pipe (Medium Grade) for watering, Charcoal andsalt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any typeof soil anddisposal of spoil to a distance n.exc50 m andnecessary testing complete all asshown in Electrical Plate No 3 of SSRPart-I.NOTE : 1. The unit rare includes for protectionh GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI wire of 32x6mm including protection pipe,from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI strip and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate 129 M&L taking down of ceiling fans of any sweep and transportation to work shopincluding dismantling for repair/overhauling, oiling, greasing, vernishing including replacementofunserviceable accessories like capacitor, connector etc. After repair re-assembling fan, testingfor efficient functioning including hanging it back in position and provn of 0.5 Sqmm copper flexible twin twisted cable (length not exceeding 0.5 metre) from ceiling rose to fan , complete all as specified and as directed by Engrs-in-Charge. 130 Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Cables, GI Pipes, etc. and keep in Safe custody for re-use, complete all as specified and as directed 131 Supply, Laying,testing and connecting XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with solid aluminium conductor 1100 volt grade of size 2 core 10 sqmm. , laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,includingBrass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etc all as specified 132 Supply, Laying,testing and connecting XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade of size 2 core 16 sqmm. , laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,includingBrass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etc all as specified 133 Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cableincludingspreading and punning down to 18 cm thickness complete all as specified and as directed.(Compacted thickness shall be measured) 134 Supply and lay in trenches fly ash bricks, for cable protection all as specified and directed by the Engr-in-Charge. 135 M & L for Boring of horizontal hole under road, pavement, hardstanding by trenchless technology using ultra sound technique and necessary machine with and including GI Pipe light grade of dia 100 with all fittings, for passing of cablecomplete all as specified.Note : (i) One run of boring of horizontal hole and one run of GI Pipe light grade of dia 100 with all fittings will be measured as one unitlength.(ii) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore.(iii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor. No extra cost will be paid on this account.(iv) Contractor has to get the survey of route, length and depth for boring before quoting the rate. 136 S&F Pipes galvanized,50 mm bore “light grade”, supplied and laid complete including necessary fittings such as tees, bends, elbows, sockets, reducers etc as per site requirement or specified. 137 Material and labour for laying of GI tubing40 mm bore, medium grade, ISI marked, conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 like elbow, socket, tee, reducer, nipple, short piece, union etcas required at site and laid in trenches incl connecting with existing lines all as directed by Engr-in-charge.Note:(i) Union or long screw have to provided at starting / end point of jointing pipe line . 138 Material and labour for laying of GI tubing25 mm bore, medium grade, ISI marked, conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 like elbow, socket, tee, reducer, nipple, short piece, union etcas required at site and laid in trenches incl connecting with existing lines all as directed by Engr-in-charge.Note:(i) Union or long screw have to provided at starting / end point of jointing pipe line . 139 Supply& fixedgun metal ,gate valve, 25 mm dia with iron wheel head, screwed both ends for iron pipe and fix complete all as specified and directed. 140 Supply& fixedgun metal ,gate valve, 40 mm dia with iron wheel head, screwed both ends for iron pipe and fix complete all as specified and directed. 141 S & F rotational moulded polyethylene ISI marked (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position with and including Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for 25mm bore dia iron pipe, provision of 25 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes including dismantling the existing one and removing to store complete all as specified and as directed. 142 Cutting existing steel tubing of bore of pipe 40/50mm for alterations or additions (Each cut measured), Screwing existing steel tubing in position without taking down

Key Value

Document Fees
INR 500 /-
EMD
INR 98600.0 /-
Tender Value
INR 49.25 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail