}

Tender For Provn Of Otm Accn For Engr Regt (Phase 1 Of Two Phases) At Panagarh., panagarh-West Bengal

Military Engineer Services has published Tender For Provn Of Otm Accn For Engr Regt (Phase 1 Of Two Phases) At Panagarh.. Submission Date for this Tender is 23-07-2025. Building Work Tenders in panagarh West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

49987756
Tender For Provn Of Otm Accn For Engr Regt (Phase 1 Of Two Phases) At Panagarh.
Tender
Indian
West Bengal
Panagarh
23-07-2025

Tender Documents

Tender Details

Tender For Provn Of Otm Accn For Engr Regt (Phase 1 Of Two Phases) At Panagarh.; 2 Construction of Building for Single Living Accn Havs/Ors (T/S) (394 Ors & 53 Havs) Cook House And Dining Hall with all fitting and fixtures etc. Complete all as specified and all as shown on drawing. 3 Construction of Building for Pump House With Toilet And Meter & Switch Room with all fitting and fixtures etc. Complete all as specified and all as shown on drawing. 4 Construction of Building for Guard House and Armoury with all fitting and fixtures etc. Complete all as specified and all as shown on drawing. 5 Construction of Alarm Post with all fitting and fixtures etc. Complete all as specified and all as shown on drawing. 6 Construction of Sentry Post with all fitting and fixtures etc. Complete all as specified and all as shown on drawing. 7 Construction of Flag Staff with all fitting and fixtures etc. Complete all as specified and all as shown on drawing. 8 Construction ofFire Point with all fitting and fixtures etc. Complete all as specified and all as shown on drawing. 9 Construction ofRefuse Bin with all fitting and fixtures etc. Complete all as specified and all as shown on drawing. 10 Construction of Static Water Tank of 50,000 Lit Capacity with all fitting and fixtures etc. Complete all as specified and all as shown on drawing. 11 Construction of UG Sump of 20,000 Gallon Capacity with all fitting and fixtures etc. Complete all as specified and all as shown on drawing. 12 Construction ofOver Head Water storage Tank of 30,000 Gallon Capacity at 21 Meter Staging height with all fitting and fixtures etc. Complete all as specified and all as shown on drawing. 13 Lumpsum price workedout by the tenderer for SITE CLEARENCE, AREA DEVELOPMENT, EARTH WORK & EXCAVATIONas listed in Schedule ‘A’ Part-II. 14 Lumpsum price workedout by the tenderer for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III. 15 Lumpsum price workedout by the tenderer for INTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-IV. 16 Lumpsum price workedout by the tenderer for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-V. 17 Lumpsum price workedout by the tenderer for REFRIGERATION AND WATER COOLER as listed in Schedule ‘A’ Part-VI. 18 Lumpsum price workedout by the tenderer for LIGHTENING PROTECTION as listed in Schedule ‘A’ Part-VII. 19 Lumpsum price workedout by the tenderer for DIRECT GENERATOR SET (DG SET)as listed in Schedule ‘A’ Part-VIII. 20 Lumpsum price workedout by the tenderer for ROAD/PATH/CULVERT/HARD STANDING as listed in Schedule ‘A’ Part-IX. 21 Lumpsum price workedout by the tenderer for AREA DRAINAGEas listed in Schedule ‘A’ Part-X. 22 Lumpsum price workedout by the tenderer forSEWAGE DISPOSAL as listed in Schedule ‘A’ Part-XI. 23 Lumpsum price workedout by the tenderer forEXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-XII. 24 Lumpsum price workedout by the tenderer forEXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-XIII. 25 Lumpsum price workedout by the tenderer forCHAIN LINK FENCING & GATE as listed in Schedule ‘A’ Part-XIV. 26 Lumpsum price workedout by the tenderer forRAIN WATER HARVESTING / RECHARGE PITas listed in Schedule ‘A’ Part-XV. 27 Sch A Part-XVI (MISC B&R AND E&M ITEMS) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. 5 siginifies this fact only.COMMON ITEM FOR ALL SCHEDULE 28 Material & Labour for mixing of Fly ash, Clinker & stone dust in proportion of 1:3:6 ( i .e10 %Fly ash, 30% Clinker and 60% Stone dust) laying , watering , ramming and compacting with vibratory roller to get min CBR value 8% and Dry density 97 % placed at required camber and gradient completeas specified and as directed.Note: - Design mix is mandatory, The unit rate quoted is deemed to include this aspect. The design mix shall be approved by the GE. 29 INTERNAL ELECTRIFICATION 30 Supply and fixing Conical Shape LED wall lamp with Metal body and B22 base retrofit holder including 7 watt led lamp (Minimum 700 lumen) complete all as specified and as directed. 31 Supply and fixingLED table / bed side lamp swan neck type with Metal bodyincluding 2 watt led lamp (Minimum 50 lumen) complete all as specified and as directed. 32 Supply and fixing PVC body exhaust fan 250mm sweep size (latest 5 star rated as per BEE of current year) with louvers, AC, Single phase 230/240 volts 900 RPM and connecting with 1.5 Sqmm, 3 Core flexible copper wire from ceiling rose to fan after and including cutting/making opening of walls and making good the disturbed surfaces completeall as specified and as directed. 33 Supply and fixing MCB DB TPN 6 ways (double door) IP-43, IK-9 protection with MCCB incommer including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed. 34 Supply and fixing MCCB triple pole and neutral (Four pole) 200 Amp, 415 volts, 50 Hz, having thermal setting range 70% to 100% and fixed magnetic setting and breaking capacity 36 KA including making incoming and outgoing connections complete all as specified and as directed. 35 Supply and fixingMCB 16 Amps, DP, 240 Volt C series, breaking capacity 10 KA including making incoming and outgoing connections complete all as specified and as directed. 36 Supply and fixing MCB 32 Amps, DP, 240 Volt C series, breaking capacity 10 KA including making incoming and outgoing connections complete all as specified and as directed. 37 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approved LT panel board indoor type, platform mounted factory made, totally enclosed dust and vermin proof openablefrom both front and rear side made out of 2.0 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paintover a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz, 3 phase4 wire systemand internal connection should be provided with copper strips of suitable size and necessary foundation workand comprisingfollowing :- (i) Copper Bus bar 200 A capacity(ii) Incoming MCCB, 4 pole, 160Amps, 415 Volt AC, 35 KA rupturing capacity- Qty 1 no(iii) Outgoing MCCB, 4 pole, 63 Amps, 415 Volt AC, 16 KA rupturing capacity - Qty 7 nos (iv) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 No(v) Digital Ammeter (Size 96x96mm) with selector switch incl CT (300/5 Amp) with all connection -01 No(vi) LED indicating lamps -03 Nos 38 INTERNAL WATER SUPPLY 39 Supply and fixing Brass Cromium Plated Wall Mixer 3-in-1 System with connector and provision for both Hand Shower and Overhead Shower complete with long Bend pipe, connecting Legs & Wall Flange (without Hand & Overhead Shower) complete all as specified and as directed. 40 Supply and fixing 15mm bore Brass CP central hole basin mixer with 450mm long braided hose for mixing hot or cold water screwed down forany type of pipe and fixed complete all as specified and as directed. 41 Supply and fixing 15mm bore Brass CP wall mount sink mixer with U shaped round casted spout with 150mm long,connecting leg and wall flange for mixing hot or cold water screwed down for any type of pipe and fixed complete all as specified and as directed. 42 Supply and fixing 15mmbore two way bib taps cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed forany type of pipe suitable for connecting with health faucet complete all as specified and as directed. 43 Supply and fixing chromium plated shower rose with shower arm revolving joints fixed to 15mm bore GI Pipe/ any other pipe complete all as specified and as directed. 44 Supply and fixing hand shower (health faucet) (brass chromium palted)with 8mm dia, 1m long, flexible tube fixed with wall hook complete all as specified and as directed. 45 REFRIGERATION AND WATER COOLER 46 Supply and install refrigerator electric driven single phase capacity minimum 320 Ltrs double door frost free BEE 5 Star rated as per latest energy efficient in level period of current year complete all as specified and as directed. 47 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1KVA complete all as specified and as directed. 48 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 2KVA complete all as specified and as directed. 49 DIRECT GENERATOR SET (DG SET) 50 Supply and installation testing and commissioning silent Diesel Enginegenerating set 415 volts 40 KVA3 phase 0.8 power factor, 50 Hz, 1500RPM self exicited self regulated brushless AC generator installed including AMF panel, control panel having meter and sound proof canopy as per CPCB norms and foundation etc.suitable for ambient condition at Panagarh and confirming to condition under ISO 3046, IS:10001/ 10002,BS 5514/5000 with capacity of 10% overloading for one hour in every twelve hour duration and including the following accessories :-(A)Alternator:- Synchrounous alternator rated at 40 KVA suitable for continuous operation at 1500 RPM generating 415 volts at 0.8 p.f (lag) suitable for 50 Hz, three phase, 4 wire system.The alternator shall be brushless, single bearing, self excited/ self regulated with an AVR. The alternator will be suitable for climate and shall generally confirm to IS: 4722 :2001. The salient features of the alternators are :- (a) +-1% voltage regulation (max) in static conditions.(b) IP:23 protections with class H insulation.(c) Permanent lubricating bearing. (B) Diesel Engine:- Adquate capacity of diesel engine water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500RPM, as per latest CPCB 4 + norms compliance upto latest ammendment complete with standard accessories. 51 (C)ACOUSTIC ENCLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Critical processes of punching is done on CNC machines to maintain dimentional accuracy of holes within 0.1 mm.Powder coating is done after seven-tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE-RETARDANT foam as acoustic material & Rock wool for hot zone.Adequate hinged doors shall be provided to canopy, one door shall have glass window for control panel visibility.(D) AMF Panel :- Automatic Mains Failure (AMF) panel made of CRCA sheet of 2 mm thick including necessary arrangement to install, testing and commissioning & connecting to load cable up to changeover switch, suitable capacity of 4 pole MCCB complete all as per OEM recommendation.(E) Civil Works :- All civil works including PCC platform and related foundations including for panel and equipments including making goodof disturbed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommended by the OEM.Note :-(i) The contractor shall be arrange for artificial resistive load inclussive of 08 Hrs for testingof DG set at site and the cost is deemed to be included in the quoted rates. (ii) If any technical left out points / specification as mention above but required for efficient working of DG Set shall deemed to included in the quoted rate. 52 SEWAGE DISPOSAL 53 Material and Labour for RCC Septic tankcoventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft, manhole openings with cover connection etc. complete with effective depth of 1.5 meter and overall depth of 3 meter for 150 users complete all as shown on drawing and as directed. [Drawing No:-CZ/TD/477] 54 Material and Labour for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia X 4.5 M effective depth for 150 users complete all as shown on drawing and as directed. [Drawing No:-CZ/TD/4/464(R)] 55 EXTERNAL WATER SUPPLY 56 Supply and laying of pipe ductile Iron, socket & spigot type, Class “K-9”, 150 mm nominal dia complete all as specified and as directed. 57 Material & labour for DI specials like Bends (any type, radius and angle) tapers any type (straight, bend, increasing,decreaing or double socket etc) Tee pieces single branch Y junction, double branch, cross for DI pipe upto 200 mm bore complete all as specified and as directed. 58 Supply and fixing 80mm bore Gun metal gate valve with iron wheel head and gun metal spindle screwed both ends complete all as specified and as directed. 59 Supply and fixing 80mm bore cast iron foot valve withbolts, nuts and washers conforming to IS-4038, PN 0.2 complete all as specified and as directed. 60 Material and labour for Construction of brick masonrychamber of 90 cm x 90 cmx 90 cm [internal dimensions] suitable for 150 mm/200 mm bore sluice valve with PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundationbrick wall with sub class ‘B’ brick, oldsize built in CM1:6 PCC [1:2:4] type B1 [using 20 mm graded stone aggregate for coping rendering in CM [1.4] 15 MMthick including provision of MS sheet cover 3 mm thick including handle, hinges locking arrangements etc with two coats of synthetic enamel paint over a coat ofred oxideprimer to steel surfaces and locking arrangement including necessary excavation and earth work in any type of soil complete all as specified and as directed. 61 Material and labour Construction of brick masonrychamber of 60 cm x 60 cmx 60 cm [internal dimensions] suitable for 50mm bore sluice valve with PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundationbrick wall with sub class ‘B’ brick, oldsize built in CM1:6 PCC [1:2:4] type B1 [using 20 mm graded stone aggregate for coping rendering in CM [1.4] 15 MMthick including provision of MS sheet cover 3 mm thick including handle, hinges locking arrangements etc with two coats of synthetic enamel paint over a coat ofred oxideprimer to steel surfaces and locking arrangement including necessary excavation and earth work in any type of soil complete all as specifiedand as directed. 62 Drilling of bore (Trial Bore) of size 250 mm dia upto 180 mtr depthby direct rotary/ DTHmechanical system for injection wellin any kind of soil strata including hard stone/boulders and submitting the strata detail both graphically recorded as well as strata results including testing of yield , complete all as specified and as directed. 63 Reaming of bore well from 250 mm dia to 525 mm dia hole in three steps from 250 mm to 350 mm, 350 mm to 450 mm and 450 mm to 525 mm dia bore siutable for lowering ERW Mild steel casing pipes and gravel packing for the required length (i.e 40 mtr depth) below the ground level, complete all as specified and as directed. 64 All as per item no 29.08 here-in-before but exceeding 40 mtr and upto 150 mtr depth, complete all as specified and as directed. 65 Supply, assembling, lowering and fixing in position 250 mm nominal (10) bore ERW MS housing pipe, ISI marked, of 8 mm wall thickness, screwed and socketed in random length upto 6 mtr including fitting of centralizer at regular interval into bore hole to a depth upto 40 mtr from ground level, as per IS 3589, painted both inside and outside with black bituminous paint suitable for drinking water purpose including necessary fittings & fixtures by jointing electric welding, complete all as specified and as directed. 66 Supply, assembling, lowering and fixing in position 200 mm nominal (8) bore ERW MS housing pipe, ISI marked,of minimum 6.0 mm wall thickness, screwed and socketed in random length upto 6 mtr including fitting of centralizer at regular interval into bore hole to a depth exceeding 40 mtr and upto 150 mtr from ground level, as per IS 3589, painted both inside and outside with black bituminous paint suitable for drinking water purpose including necessary fittings & fixtures by jointing electric welding, complete all as specified and as directed. 67 Supply, assembling, lowering and fixing in position low carbon galvanized (LCG) steel strainer pipe 200 mm nominalbore of wall thickness 7.00 mm cagetype wire wound screen ‘V’ shaped profile in suitable length having slots of size 1.6 mm width including necessary end coupling, welding as required and including special sockets for connecting to MS pipe, complete all as specified and as directed. 68 Supply and fixing mild steel reducer suitable for (250 x 200 mm ) bore casing pipe, 10 mm thick, fitted to casing pipe as per IS 2800 by means ofelectric welding ,complete all as specified and as directed. 69 Material and labour for carrying out electro logging test upto complete drilling depth of tube well for fixing water strata and submitting of Report including its interpretation by a qualified Hydrologist/ground water expert, complete all as specified and as directed. 70 Material and labour for Yield test with the help of V notch for bore well by continiously pimping for 16 hrs to determine safe pumping yield, complete all as specified and as directed. (Note : Rate quoted by contractor shall deemed to be inclusive the rate of Pump, DHPP and required T&P ) 71 Supply and fixing mild steel bail plug assembly suitable for 200 mm bore casing pipe internal threaded with strong iron hook, screwed and welded to casing pipe as per IS 2800, complete all as specified and as directed. 72 Supply, filling and packing washed pea gravels of size 2 mm to 4.6 mm all around casing pipe and slotted pipe, complete all as specified andas directed 73 Supply and fixing mild steel housing clamps 1200 mm long 100 mm wide, made out of 20 mm thick MS plate made to shape for 250 mm bore casing pipe with necessary bolts, nuts and washers at ground level, complete all as specified and as directed. 74 Developing of tube well by means of air compressor, for number of hours, until sand free clear potable water is obtained including testing by using diesel engine driven turbine pump to get maximum yield and discharge including supply of yield test result, complete all as specified and as directed.(Note : Rate quoted by contractor shall deemed to be inclusive the rate ofDHPP and required T&P ) 75 Supply and fixing pressure gauge with isolation cock suitable for a working pressure of 7 Kg/cm² (Liquid based High Intensity), complete all as specified and as directed. 76 Supply and laying flat PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 10 Sqmm 3 core including jointing material and connection work, complete all as specified and as directed. 77 Supply and fixing round strand steel wire rope dia 12 mm and connected clamp nut bolts fixed, complete all as per directed. 78 Supply and fixing 80 mm bore galvanized steel tubing medium grade, 6.00 metre long in twin arrangements as in gravel filling arrangement to bore wellfixed 5 metre below ground level and 1 metre above ground level, inclined at an angle of 40 degree from horizontal plane of ground, including PCC (1:2:4) foundation of size 1m X 1m X 0.75m complete all as specified and directed. Note- PCC foundation block for the pipes will be measured and paid separately under respective items in this schedule. 79 Supply, lowering and fixing MS column pipe 100 mm bore, medium grade, confirming to IS, 3 meter long pipe both end flanged, threading, welding and drilling of holes, cutting of ducts of size 10 mm x 20 mm 2 No. in each flange for fixing submersible cable, including rubber gasket of suitable size, nuts, bolts, washer etc including painted internally and externally with two coat of non corrosive non toxic bituminous paint including making all type of connections as required, complete all as specified and as directed. 80 Supply and fixing well capmade out of 5 mm thick MS plate with provn of suitable holes for passing two runs of flat 3 core PVC insulated sumersible cablemotor and one run of SWR, 100 mm dia column pipe and suitable for fixing 250 mm nominal bore ERW heavy duty MS of 8.0 mm wall thickness casing pipe complete all as specified and as directed. 81 Supply, install, testing & commissioning ofmonoblock type Centrifugalpump suitableforminimum Discharge min 570 LPM at 36 Mtr head with cast ironcasing, bronze impeller, SS shaft,electric driven,10 HP, 415 V, TP suitable for under ground sump complete all as specified and as directed. (Two Centrifugal pump for sump)Note: The quoted rate shall deemed to be inclusive the rate of PCC foundation for pumps and electric wiring from starter to pump through MS conduit placed under floor/ wall etc as required basis. 82 Supply, install, lowering, testing & commissioning of Submersible pump set 8 stage Suitable for minimum head 40 Mtr with 285 LPM discharge electric driven 7.5 HP, 415 V AC, TP with operational efficiency performance and durability wide voltage range 350-440 Voltssuper finished water lubricated bush bearing , with less speed drop motors with teflon bearing and sand guard complete all as specified and directed. (One running and one stand by) 83 Supply, install, connecting, testing & commissioning of high pressure single head adjustable chemical dozing system of the following specification:-a) Adjustable high pressure 100 PSIG power input 230 V, 50 Hz, max flow rate 02 US GPD to 40 US GPD with mandatory assecceries like lead tubing connecting ferrules, check valves, etc. alongwith 100 Ltr capacity FRP tnk as preperation tank.b) Prepration tank, dozing tank, consist of water inlet line, outlet with Y strainer, overflow conical bottom for sludge deposition and agitator as per OEM Specification. 84 Supply and Installation of Iron remover plant complete with pressure filter, catalytic media, air compressor, back washing facility including RCC foundation of capacity 8000 gallon/hrs, Consisting of following:(a) Supply, installation, testing and commissioning of down flow MULTIGRADE FILTER having capacity 35000 LPH/8000 GALLON PER HOUR consisting vertical cylindrical mild steel pressure vessel with dished end, having size of 1200 mm dia X 1875 mm height Vertical type one set of 100 mm dia nominal bore frontal mild steel pipe work for inlet, outlet, back wash and rinse line and 5 No butter fly valve having hand lever type complete all as specified and directed.Note: -(i) The pressure vessel shall be made of Heavy Grade MS Sheet 4 mm thick(ii) Dished ends shall be machine made of Heavy Grade MS Sheet 5 mm thick (iii) The filter plant shall ensure even distribution across the surface area of the filter bed, header, lateral system & bottom collecting system.(iv) The plant shall have Air release arrangement with 2 No pressure gauge to monitor head loss across the filter and sampling cocks on inlet and outlet ends. The filter plant shall have full charge of filter media as per manufacturer’s design(v) Depth of filter media shall 915 mm and total media quantity shall be as per OEM specification. (Gravels, Pebbles, Silex, Core Silex & Sand).(vi) The filter have man hole, hand hole and supporting legs. 85 (vii) The job shall include necessary surface dressing, PCC/RCC foundation as required complete all as specified & as directed bymanufacturer & the same duly approved by officer.(viii) The vessel shall be painted internally with 2 coats of anticorrosive and nontoxic black bituminous paint (compatible with drinking water) and external surface shall be painted with 2 coats of Synthetic Enamel paint over a coat of red oxide primer.(ix) The plant shall be designed for a flow of 35000 LPH(x) The MULTIGRADE FILTER shall have first fill of filter as per manufacturer’s instruction.(xi) The TURBIDITY after treatment from should be <=1 PPM. (xii) The backwash frequency shall be every 12 hours (twice a day) for continuous operating unit. If unit is operated intermittently, the total operating time in service cycles shall be limited to 5-6 hours before next back wash & back wash time 15-20 minutes.TECHNICAL SPECIFICATION:MULTIGRADE FILTER FLOW RATE(m3/hr) - 35QUANTITY(NOS) - 1FILTER DIA(MM) - 1200FILTER HEIGHT(MM) – 1875SHELL THICKNESS(MM) - 4DISHEND THICKNESS(MM) - 5FRONTAL PIPE WORK(MM) - 100MEDIA DEPTH(MM) - 915 86 MEDIA QUANTITY - Shall be as per OEM Specification.BACKWASH TIME - 20-30 Minutes(b) Inter connecting pipe work-MSEP for Multigrade Filter(c) Supply, installation, testing and commissioning of down flow OXIDIZATION PLANT having capacity 35000 LPH/8000 GALLON PER HOUR consisting vertical cylindrical mild steel pressure vessel with dished end, having size of 1000 mm dia X 1875mm height Vertical type one set of 100 mm dia nominal bore frontal mild steel pipe work for inlet, outlet, back wash and rinse line and 5 No butter fly valve having hand lever type complete all as specified and directed.Note: - (i) The pressure vessel shall be made of Heavy Grade MS Sheet 4 mm thick(ii) Dished ends shall be machine made of Heavy Grade MS Sheet 4 mm thick (iii) The filter plant shall ensure even distribution across the surface area of the filter bed, header, lateral system & bottom collecting system.(iv) The plant shall have Air release arrangement with 2 No pressure gauge to monitor head loss across the filter and sampling cocks on inlet and outlet ends. The filter plant shall have full charge of filter media as per manufacturer’s design(v) Depth of filter media shall 915 mm and total RESIN quantity shall be as per OEM specification.(vi) The filter have man hole, hand hole and supporting legs. 87 (vii) The job shall include necessary surface dressing, PCC/RCC foundation as required complete all as specified & as directed bymanufacturer & the same duly approved by officer.(viii) The vessel shall be painted internally with 2 coats of anticorrosive and non toxic black bituminous paint (compatible with drinking water) and external surface shall be painted with 2 coats of Synthetic Enamel paint over a coat of red oxide primer(ix) The plant shall be designed for a flow of 35000 LPHTECHNICAL SPECIFICATION:IRON REMOVAL FILTER - FLOW RATE(m3/hr) - 35QUANTITY(NOS) - 1FILTER DIA(MM) - 1000FILTER HEIGHT(MM) - 1875SHELL THICKNESS(MM) - 4DISHEND THICKNESS(MM) - 4FRONTAL PIPE WORK(MM) - 100MEDIA DEPTH(MM) - 915MEDIA NAME - MNO2MEDIA QUANTITY(KG) - Shall be as per OEM specificationBACKWASH TIME - 20-30 Minutes. 88 (d) Interconnecting pipe work-MSEP for Oxidation Chamber(e) Supply, installation, testing and commissioning of Sodium Hypochlorite Dosing Pump capacity 0-6 LPH & 0.4kg/cm2 with 150 ltr LDPE Dosing Tank.(f) Supply of Iron testing kit with 1 ltr solution complete-01 No.(g) Supply of chlorine testing kit with solution complete--01 No.Note:-(1) The CGW report shall be made available to the department.(2) The Capacity of Iron removal plant is indicative. The Iron removal plant shall be designed based on the water testing report.(3)Necessary chlorination plant must be catered for the treatment of bore well water in addition to above items(4)The vessel must be filled up with specially grade MnO2 (minimum 65% purity) and gard coke catalyst media of quantity as per manufacturer instructions with supporting under bed media. 89 Supply, Install, testing and commissioning of air compressor reciprocating type, horizontal model of capacity as recommended by OEM of IRP coupled with electric motor of suitable capacity for 440 Volts, 3 phase 502 Hz complete with Air receiver safety valve including copper cable connection from main panel to starter and starter to motor, DOL starter panel, PCC/RCC foundation, earth workand providing 15mm dia GI pipe medium grade from compressor to oxidation chamber including air filter etc complete all as per specification of manufacturer and as directed by Engr-in- Charge. 90 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approved LT panel board indoor type, platform mounted factory made, totally enclosed dust and vermin proof openablefrom both front and rear side made out of 2.0 mm thick CRCAMS Sheet and built upon suitable size angle ironframe work , having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paintover a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz, 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing (For pump house):- (i) Aluminium Bus bar 200 A capacity(ii) Incoming MCCB, 4 pole, 125Amps, 415 Volt AC, 25 KA rupturing capacity- Qty 1 no(iii) Outgoing MCCB, 3 pole, 32 Amps, 415 Volt AC, 25 KA rupturing capacity - Qty 5 nos (01 For submersible pump, 02 For centrifugal Pump, 01 for street light and 01 standby)(iv) Outgoing MCB 4 pole 32 Amps, 10 kA, 240 volts- 02 NOS (Pump house & Street light)(v) Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 No(vi) Digital Ammeter (Size 96x96mm) with selector switch incl CT (300/5 Amp) with all connection -01 No(vii) Star delta starter - 04 Nos (7.5HP -02 Nos & 10 HP- 02 Nos) (viii) LED indicating lamps -03 Nos, (ix) Time switches 415 V three Phase of 20 Amp rating with contactor-01 No. 91 Supply, install, commissioning and connecting of water level indicator made out of stainless steel (scale min 150mm width & 1 m in length) including floats, PVC rope, SS pully, pully cover, etc complete all as specified and as directed. 92 EXTERNAL ELECTRIC SUPPLY 93 Supply and fixing LED street light fitting 36 Watt 230 V AC outdoor type having system lumen not less than 110 Lm/W and potted driver with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket 40mm dia 1.2m long with impact and corrosion resistant including thermal management in multiple optics complete with IP-66 protection complete all as specified and as directed. 94 Supply & fixing junction box with 3 phaseterminals and size of box 155x210x92 or nearest higher size grade of polycarbonate body with IP 66/67 degree of protection, dust proof watertight, shock proof fire retrant with internally embeddedgasket fitted with heat treated bakelite terminals blocks and PVC glands for cable entry complete all as specified and as directed.(48 Nos for street light & 12 nos for flood light) 95 Supply & fixing Three core 1.5sqmm(nominal area)service wire PVC insulated copper conductor FRLS, multi stranded, unsheathed 1100 volts grade IS-694 marked for connection from junction box to street light fitting through steel pole with necessary clamps, bolts, etc required for fixing complete all as specified and as directed. 96 Supply , install, testing and commissioning of cubical housing cabinet type CPRI approved Confirming to IP55 LT panel board outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openablefrom both front and rear side made out of3.15 mm thick CRCAMS Sheet and built upon suitable size MS angle ironframe work, having front and rear hinged doors, lifting lugs (2 Nos), earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts, spring and washers.The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply spray paint with two coat of synethetic enamel paintover a coat of red oxide primer. The panel should be suitable for 415 volts, 50Hz, 3 phase4 wire systemand internal connection should be provided with aluminium strips of suitable size and necessary foundation workand comprisingfollowing (Feeder Panel 1) :- 97 System Voltage-415V, 3-Ph, 4 wire, 50 HZAluminium BUSBAR rating -200 Amps, cable entry (incomming and outgoing ) form bottom with cable gland Incomming : 125 Amps MCCB FP,50 KA of electric release with over load adjustment 0.4 to 1.0 In & short circuit electronic release adjustment 1.5 to 10.0 In (adjustment current with time), 415 Volts, 50 Hz-01 No (Incoming from CSS)Outgoing -(a)MCCB 4 pole 100 Amps 25 kA adjustable thermal release 0.64 to 10 In & adjustable magnetic release (3.5 to 10 In)- 01 No (For OR Accn) (b)MCCB 4 pole 32 Amps 25 kA adjustable thermal release 0.64 to 10 In & adjustable magnetic release (3.5 to 10 In) - 02 Nos (1 Guard House + 1 spare)(c)Digital volt meter (size -96x96mm) 0-500 volts with selector switch -01 Nos(d) Digital Ammeter (Size 96x96mm) with selector switch incl CT (500/5 Amp) with all connection -01 No (e) LED indicating lamps -03 Nos 98 Supply,installation and commissioningofCompact Secondary Substation (CSS) 500KVA comprising to following parameters:-(a)CPRI approved CRCA Sheet steel housing 3.15 mm thick with corrosion resistance and all side openable hinged door and lock and key arrangements.(b)Steel parts are tested as per IS 6988.(c)Engineered for smooth air flow for natural cooling.(d)No access to High voltage parts.(e)GI strip earthing for lightening protection and lightening spike etc.(f) Separate earthing for lightening protection and lightening spike etc.(g)Seperation steel sheet wall for CB/ Transformer / LT Panel.(h)Heavy lifting lugs with all equipments load.(j) Slopped roof.(k)Necessary danger plates outside of the CSS.(l) Necessary HT and LT cable / Earth strips opening.(m) Circuit Breaker (CB) in SF6 insulated stainless steel enclosure. commissioning of with metering module with necessary CTs and PT, comprising the following :- (Complete unit is to be installed inside CSS, protection accessories, Enclosure: Metal Clad, IP-54 Protection.Protection Relay : Self Powered AlfapneumaticLCD disply type Internal are tested for 1 sec, Fully compartmentalized sheet steel enclosure with automatic safety shutters, GI foundation bolts with provision of cable terminating facilities with powder coated smooth glossy finish and as per follows: 99 (i) Rated Voltage - 12 KV(ii) Rated Frequency -50Hz.(iii) Rated continuous current rating - 630 Amps(iv)Rated Interrupting Current- 21 KA(v)Rated making current for VCBs - 52 KA.(vi)Rated making current for Isolators-62 KA(vii)Rated short time current for 3 sec -26.3 KA(viii) Operating duty -0-0.3 sec-CO 3 min – CO(ix)Power frequencywithstand voltage- 28 KV(x) Impulse withstand voltage - 75 KV.(xi)Bus bar rating - 120% of continuous current. (xii) Operation: Spring closingmechanism - DC moter operated with 24 volt supply, Breaker Closing - Manual & Electrical through TNC switch.(xiii)Shunt Trip coil - 24 V DC(xiv) Safety Interlock Locking facility – Required(xv) Breaker panel indication - ON (RED) / OFF( Green)(xvi) Accessories:Mechanical counter, Space heater with Thermostat, Fuse and ON/OFF switch,Aux relays for remote trip/ indication for PC interface etc, cubicle illumination lamp LED 9 watt retrofit type 230 V AC, T-N Switch,Anti pumping contractoretc.(xvii)Mimic Diagram: An operating mimic diagram shall be provide on the front side of each cubicle 100 (xviii)Battery Bank with charger for RMU is included in the item rate and rating of battery as described by OEM.(Note:- CB complete will be obtained directly from the OEM andnot from the authorized system assemblers of OEM. The installations, calibration and testing of CB will be conducted in the presense of authorized representative of OEM by the Contractor.)(n) Transformer 500 KVA Copper wounded dry resin cast distribution type 11/0.433 KV , 3phase, 4 wire LT output 50 Hz DYN 11 suitable for indoor installation ofload tape changer with step +7.5% upto (-)7.5% in step of 2.5 % on HT side all technical specificationcomprising to IS 1180 part I&II with all necessary standerd fittings and accessories coplete after necessary testing after complition with the following specification (i) Standerd KVA Rating - 500 KVA (ii) Primary Voltage - 11 KV AC (iii)Secondry Voltage - 433 Volts (iv) Neutral earthing should be solidly earth system. (v) Rated Frequency - 50 Hz with +(-) 3% Tolerance. 101 (o) LT panel for 500 KVA Transformer made with 2 mm CRCA sheet with necessary angle ironframe and vermin proof font side openable double door with necessary locking arrangement opening for bus bar / cable entry opening for natural air ventilation / coolingnecessary Ammeter, Voltmeter, selector switch, CTs, suitable size bus bar, paints and primer with Air Circuit Breaker (ACB) as incomer 800A, 50 KA, 415 V, AC, 50 Hz, 4 Pole with necessary setting and microprocessor control draw out type 1500 Amps bus bars, as out goingMCCB 315 Amps -02 Nos , MCCB 160 Amps - 03 Nos & , 32 A MCB TPN -02 Nos(Note: All outgoing MCCBs should be adjustable thermal and magnetic protection and Ics =100% Icu for all MCCBs).(p)Necessary interconnections for HT and LT equipments with suitable size insulated copper bus bar.(q)Necessary foundation for installations of CSS.(r)APFC panel of 15 KVAR complete with all controlling switchgear and of 5 KVAR x 01 No , 2 KVAR X 05 Nos steps and necessary automatic controller and switching device, 440 V, AC 3 Phase, 50 Hz rating with MD-XL type heavy duty capacitor. This panel needs to be connected directly with main LT panel bus war with suitable size LT cable. 102 Supply, fixing, testing and commissioning of solar street light fitting LED 24 Watt high AIO power LED delivers system lumen output > 120LM/W including minimum life upto 50,000 hrs, confirming to IP-65, Power Suppply >80%, galvanised steel pole in built, Lithium FERRO PHOSPHATEbattery not less than 100 Ah solar panel, charge controller with dusk down sensor complete with all necessary accessories as directed.Note:- All excavation earthwork and PCC shall be measured and paid seperately under respective item.

Key Value

Document Fees
INR 3000 /-
EMD
INR 2575000.0 /-
Tender Value
INR 54.80 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail