Tender For Comprehensive Day To Day Maintenance Work Of Md Accommodation At Mirthal Under Ge South Pathankot.; 1 Resecuring or easing andadjusting without taking down ofshutter area exceeding 1.00 sqm but not exceeding 2.00 sqm each of complete all as specified and directed. 2 Taking down shutter and refixing in same opening after easing same shutter area exc 1 Sqm but n exc 2 Sqm each of complete all as specified and directed. 3 S&F in repair 300mm ordinary rat rail, rod pattern mild steel springs ISI marked including roller and roller plate complete including all necessary welding if required complete all as specified and directed. 4 Taking down shutters of any description exc 1.00 sqm and not exc 2.00 Sqm each complete all as specified and directed. 5 Taking down chowkat or frame with shutter (without taking off shutter from the frame) not exceeding 1.50 Sqm each including taking out hold fast embedded in PCC, complete all as specified and directed. 6 Taking down chowkat or frame with shutter (without taking off shutter from the frame) exceeding 1.5 Sqm and n.exc 4 Sqm each, complete all as specified and directed. 7 S&F prelaminated 18mm thick lead free factory made 100% solid WPC (wood polymer composite) sheet having high natural fiber content 25 to 30% wood colour sheets with density not less than 500 Kg/Cum and the weight of sheet of 1 sqm should be 11 Kg (+-5%) manufactured by ISO 9001-2015 certified company the sheet should be 100% water proof termite proof, fire retardant, manufactured by single layer extrusion process with excellent screw holding capacity and shore D hardness complete including all fittings likehandle, hinges, hydraulic stopper, beading etc. as per direction of Engineer-in-charge. 8 S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other frame/Chowkhat of size 45x70mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum , screw withdrawal strength of 2200N (Face) & 1100N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with properly of being termite/borer proof, water/moisture proof and fire retardant 152 Section 8 and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. 9 S & F Magnetic door catches with sticking plate of standard size for cupboard doors as approved by GE. 10 M&L for Non skid ceramic colour tiles 7 to 8 mm thick (sq/ rect) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, infloor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:6 including dismantling of floor tiling incl cement mortar bedding (but not backing) removing serviceable tiles to a store and rubbish off premises complete all as specified and directed. 11 M&L for providing glazed ceramic colouredwall tiles of size 450mmx350mmx7mm thick, set, jointed in colour cement to match laid over and including 10 mm thick rendering in cement mortar 1:4 including dismantling ofwall tiling incl cement mortar bedding (but not backing) removing serviceable tiles to a store and rubbish off premises, complete all as specified and directed. 12 M&L for vitrified ceramic tiles, light shade 10 mm thick (sq/ rect) polished, area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, infloor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:6 including dismantling of floor tiling incl cement mortar bedding (but not backing) removing serviceable tiles to a store and rubbish off premises, complete all as specified and directed. 13 Demolition of Concrete of any description (unreinforced) and in any position, complete all as specified and directed. 14 M&L for 75mm thick PCC (1:3:6) type C2 using 40mm graded crushed stone aggregate as in sub base/ floor complete all as specified and directed 15 M&L for 1:5:10 type E2 cement concrete in foundation , filling and mass concrete, complete all as specified and directed. 16 S&F Doctor fixit Pidifin 2k high performance 2 component flexible Acrylic polymer modify cement base water proofing coating in two coats 1mm thick dry film mixed in ratio 2:1 by weight or 1:5:1 by volume product of M/S Pidilite Industry Limited Makers of Fevicol adhesive brand. 17 S&F Aluminium alloy, anodised, sliding door bolt 300mm longwith hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and directed. 18 S&F 100mm long butt hinges medium weight cold rolled ISI marked mild steel, complete all as specified and directed. 19 S&F 125mm extruded aluminium alloy handle fabricated anodized ISI marked complete all as specified and directed. 20 S&F 150mm long aluminium, anodized barrel tower bolts of extruded section ISI marked complete all as specified and directed. 21 S&F for hasp and staple aluminium anodised 100 mm long with mild steel hinge pin including bolt to hinge plate and fixed with screw complete, 22 S & F for Continuous (Piano) type hinges mild steel bright finish or electro galvanized with wide of flaps 30mm complete all as specified and directed. 23 Taking down cement plaster on brick or concrete surfacesany description including raking out joints hacking for key scrubbing down with water complete all as specified and directed. 24 M&L for15mm thick plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement including scaffolding at any height complete all as specified and directed. 25 M&L for Rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. 26 M&L for preparation of New plastered surfaces of wall including scaffolding up to 7m height,two coats of cement base paint over a coat of primer on newly plastered surfaces of wall including preparation of surfaces and curing after applying each coat, complete all as specified and directed. 27 M&L for preparation of new plastered surfaces of wall including cornices plastersand applying two coats of oil bound distemper over a coat of primer on wall complete all as specified & directed by Engr-in-Charge. 28 M&L for rendering 10mm thick on concrete in CM 1:3in facia or edging of chajjas, ceiling and roof projectionmaking the line in true shapefinished even & smooth without using extra cementincluding scaffolding up to 7 meter height, complete all as specified and directed. 29 M&L for preparation of new plastered surfaces of ceiling, chajjas and roof projectionand applying two coats of oil bound distemper on ceiling, complete all as specified and directed. 30 M&Lone coat of cement base paint on wall includingpreparation of surfacecomplete all as specified & directed by Engr-in-Charge. 31 M&L Complete removal of existing treatment from internalsurfaces of walls by wire brushing and washing, rubbing down and stopping of surfaces, applying 1mmwall care puttyon walls and make the surface of level, clean and repair disturbededges of bricks/concrete walls finish to even and smooth and applying two coats of oil bound distemper over a coat ofprimer all as specified and directed by Engr-in-Charge. 32 S&FRotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted fixed in position all as specified in SSR part-I, capacity of tank 500 ltr incl inlet and outlet connection 20mm dia and 15mm dia GI pipes medium grade respectively 20mm GI pipe medium grade over flow pipe 15cm long and PTMT valve 20mm high pressure with polyethylene float and fly nuts including dismantling water tanks (capacity of tank exc. 250 ltr but n. exc. 500 ltr) and removing from site complete all as specified and directed. 33 S&F Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted fixed in position all as specified in SSR part-I, capacity of tank 1000 ltr incl inlet and outlet connection 20mm dia and 15mm dia GI pipes medium grade respectively 20mm GI pipe medium grade over flow pipe 15cm long and PTMT valve 20mm high pressure with polyethylene float and fly nuts including dismantling water tanks (capacity of tank exc. 500 ltr but n. exc. 1000 ltr) and removing from site complete all as specified and directed. 34 Disconnecting existing tanks, exc 250 ltr n exc 500 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. Cleaning and removing all scale and dirt, etc, from tanks and from mouths ofcirculating pipes, etc. complete all as specified & directed. 35 Disconnecting existing tanks, exc 500 ltr n exc 1000 ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. Cleaning and removing all scale and dirt, etc, from tanks and from mouths ofcirculating pipes, etc. complete all as specified & directed. 36 S&F in repair vitreous China squatting pan Orissa pattern size 580 x 440mm white with integral foot rest (excluding flushing cistern and flush pipe), including connection to trap, and to flushing pipe, anti syphonage pipe etc. and including 110mm bore PVC P or S trap complete incl making good to floor complete all as specified and directed. 37 S&F in repair for Vitreous China wash down water closet pan including P or S trap (pedestal pattern), white or in matching colour of tiles (excluding flushing cistern and flush pipe) including plastic water closet seat cover white colour or in matching colour with closet closed pattern with flat bottom cover and mild steel chromium plated or aluminized hinging device and wash down water closet complete all as specified and as directed. 38 S&F in repair vitreous china wash hand basin (flat back or angle back type)colouredof bowl size 550mmx400mm including waste and waste pipe PVC 32mm dia to be fixed over marble slabs or iron brackets complete all as specified and directed. 39 S&F in repair plastic water closet seat cover, back closed pattern with flat bottom,and mild steel chromium plated or aluminized hinging device complete all as specified and directed. 40 S&F in repairs 10 litres PVC low level flushing cistern( white colour) symphonic action type with inlet ball valve float and push type handle including bracket, PVC 32mm diaflush pipe with coupling and fixed complete all as specified and directed. 41 S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen with plugs, washer and waste including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed. 42 S&F sinks made of stainless steel w/o drainage board 1mm thick kitchen or laboratory with plugs, washers and wastes pipe and waste coupling including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, bowl size 495mm x 395mm x 195mm complete all as specified and directed. 43 S&F in repair bib taps, fancy type, chromium plated, cast copper alloy ISI marked with crutch or butter fly handle high pressure screwed down screwed for iron pipe of 15mm bore, complete all as specified and directed. 44 S&F in repairs 15mm boreAngle valve, cast copper alloy fancy type chromium plated ISI marked with crutch or butter fly handle high pressure screwed both ends for iron pipe or for union and fixed complete all as specified and directed. 45 S&F in repair centre hole basin mixture valve, cast copper alloy fancy type 15mm brass chromium plated mixer (central hole basin mixer w/o pop up waste system) for mixing hot & cold water screwed down for iron pipe , complete all as specified. 46 S&F in repair pillar tap, cast copper alloy, chromium plated, fancy type with capstan heads screwed down high pressure with or without lettered hot or cold with long screwed, shanked and fly nuts screwed for iron pipe 15mm dia complete all as specified and directed. 47 S&F in repair Brass Chromium Plated wall mixture valve cast copper alloy fancy type for mixing hot and cold water screwed down high pressure with capstan head screwed both ends for iron pipe 15mm bore dia complete all as specified and directed. 48 S&F in repairs 25 mm dia stainless steel curtain rod design/ shape approved by Engr-in-Charge complete all as specified and directed. 49 S&F in repair MS bracket(turned, weathered and mitered) brackets ofwith cut, hole suitable for 25mm dia rod fixed with screws and gutties in wall complete all as specified & directed. 50 All as per serial item No. 48 here-in-above, but end caps with wall ornament and fixed to curtain rod with screws of design/shape all as specified and directed . 51 S&F in repair galvanized mild steel wire cloths 0.46mm nominal dia and average width of aperture 1.18mm & fixed with tint tacks or galvanized wire staples complete all as specified and directed. 52 S&F in repair Cabinet Mirror of size 400mmx500mmx6mm thick with frame as per Cat Part No.554 of Prayag or techno commercial equivalent complete all as specified and directed. 53 S&F 600x450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood & fixed to wooden plugs with chromium plated beads screws & cup washers, complete all as specified and directed. 54 S&F sheet glass 3.00mm thick ordinary quality and glazing with oil putty in square n.exc 0.50Sqm in each panes including glass pin, complete all as specified and directed. 55 S & F 3mm thickfigured Sheet glass pin headed type and glazing with oil putty and pins in square n exc 0.5 sq. m in each pane on complete all as specified and directed. 56 Hacking outold broken glass (any thickness, size, quality or description) from wooden frames, glazed with putty or fixed with beads complete all as specified and directed. 57 S&F 15mm bore GI tubing medium grade galvanized ISI marked with all fittings complete on walls including taking up or down GI pipe 15mm bore and connections, including removal unserviceable pipe complete all as specified and directed. 58 S&F GI tube 20mm bore medium grade galvanised with all fittings and fixed to short length incl taking up or down GI pipes 20mm bore and connection including cleaning for refixing or removal un-serviceable pipe,complete all as specified and directed. 59 Supply & Fixing in repair Stainless steel Plate rack 1mm thick of size900mm x 600 mm x 200mm deep with plate racks, spoon holders, shelves etc. complete all as specified and directed. 60 M & L for sheet glass 5.5 mm thick heat absorbing/solar control film/tinted and glazing with oil putty/aluminium bedding in square n exc 0.5 sqm in each complete all as specified and directed. 61 S&F in repair floor door stopper of overall length of cover plate 140mm aluminium alloy body and tongue, anodised, with hard drawn steel spring fixed in floor complete all as specified and directed. 62 Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed. 63 M&L for brick work in cement mortar 1:4 of old size sub class ‘B bricks straight or curved on plan exceeding 6mtr mean radius complete all as specified and directed. 64 M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick wallsbuilt in cement mortar 1:4, complete all as specified and directed. 65 S&F in repair 20mm PTMT ball valve high pressure with epoxy coated aluminium rod & high density plastic ballscrewed for iron pipe and fixed, complete all as specified and directed. 66 S&F in repair brass chromium plated tublar towel rail 20mm dia D type 60cm long between flanges, complete all as specified and directed. 67 S&F in repair towel ring of PTMT fixed with and including Chromium plated brass screws and plastic cleats ( min wt. 90 gms)complete all as specified and directed. 68 S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. 69 S&F in repairs brass chromium plated shower rose 75mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified and directed. 70 S&F in repair Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed. 71 S&F in repair mild steel, chromium plated Soap Dish fixed with and incl CP screws all as specified and directed. 72 S&F in repair of CP health faucet with ABS body, 1.25 mtr long flexible tube &hook fixed with and incl CP screws complete all as specified and directed. 73 S&F 5.5mm thick glass shelf 12cm widewith cp bracket guardand60cm long CP railing including chromium plated brass screws and wooden/plastic cleats as in repair,complete all as specified and directed. 74 S&Ffor Cornerglass shelf assembly consisting of 5mm thick sheet glass shelf 30cm wide with chromium plated bracket guard and railing. 75 S&F in repair stop valves (ISI marked),15mm dia, cast copper alloy, chromium plated fancy type with long shank and cup (concealed type) screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipes or for unions and fixed in pipe, complete all as specified and directed. 76 S&F for 110mm bore, PVC (SWR) P trapas in repair complete all as specified and directed. 77 S&F for 75mm bore, PVC (SWR) floor trapas in repair complete all as specified and directed. 78 S&F in repair 32mm bore corrugated PVC waste pipe, 90 cm long for WHB with cup, complete all as specified and directed. 79 S&F grating round 100mm size of stainless steel as in repair, complete all as specified and directed. 80 M&L for preparation of old painted wooden surface of any description exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. 81 M&L for Preparation of old painted steel surface of any description exc 10cm width or girth and applying one coat of synthetic enamel paintcomplete all as specified and directed. 82 S&F in repairs brass spindle for bib tap/ pillar tap etc all as specified and directed by Engineer-in-Charge. 83 S & F in repair for peg set of 5 Pin Stainless steel Grade, AISI 304, fancy type, superior quality with fixing arrangement complete all as specified & directed. 84 S&F in repair sinks couplingof required size 50/ 65/ 75/ 100 mm approved by Engr-in-charge complete all as specified and directed. 85 S&F for replacing of GI fittings medium grade ISI marklike long screw Elbow for 15mm bore pipe complete all as directed. Note: Cost of taking down GI tubing for replacement of worn out/defective GI fitting & refixing there after shall be deemed to be included in the rates quoted by the contractor 86 All as per serial item No 85 but socket 87 All as per serial item No 85 but nipple (100mm) 88 All as per serial item No 85 but nipple(150mm) 89 All as per serial item No 85 but Tee 90 S&F for replacing of GI fittings medium grade ISI marklike long screw elbow for 20mm bore pipe complete all as directed. Note: Cost of taking down GI tubing for replacement of worn out/defective GI fitting & refixing there after shall be deemed to be included in the rates quoted by the contractor. 91 All as per serial item No 86 but socket 92 All as per serial item No 86 but nipple(100mm) 93 All as per serial item No 86 but nipple(150mm) 94 All as per serial item No 86 but Tee 95 S&F in repair internal flushing cistern kit of make approved ny Engr- in-charge complete all as spd and directed. 96 Dismantling/taking down of cast iron or unreinforced concrete or PVC soil waste and drain pipe 75mm or 100mm dia with all fittings complete all as specified and directed. 97 S&F, 110mm bore, PVC rainwater (SWR) drainage pipes single socketed, in any length with rubber ring joints as in repair, fixed to walls with sufficient number of Iron stack clamp complete all as specified and directed. 98 S&F of 75mm PVC (SWR) drain pipes 75 mm bore single socketed in any length with rubber ring joint fixed to walls complete all as specified and as directed. 99 S & F in repair Sintex water tank cover (Dhakkan)fixed with screws for 500and1000 Ltrcapacitywater storage tank. 100 S&F in repairs Door seal (Snake guard) with Aluminium frame powder coated up to 900 to 1000mm door opening complete all specified 101 M & L for Securing old glass of any description in existing steel/wooden frames glazed with putty/beads including removing loose or decayed putty/beads, reputtying to match existing work etc. and fixed complete all as specified and directed. 102 S&F Solid PVC door frame of size 50mmx47mm made out of 5mm prelam PVC sheet used instead of Plain colour PVC sheet and edges will be painted to match with prelam sheet reinforced with MS Square tube, supplying & fixing in opening as per specification and drawing. Note : Door frame shall be water proof, termite proof, elegant and should have excellent screw holding strength to fix hinges and hold doors properly for long life) 103 S&F Factory made Solid PVC Moulded Door Shutterwith wood free EPS, 28 to 30mm thick (stiles) with 5 mm thick moulded prelam PVC sheet on the front face and 5 mm prelam PVC sheet on back face, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed. 104 S&F steel window/ventilator with tubular frame factory made double shutters of size 79mm x 39mm, 16 gauge rectangular tubular frame withside hung shutter with glazing bars 12x3mm flat iron incl projecting type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long and 10mm square bar grills complete, includingtwo coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. 105 M & L for cement concrete type C-0, 1:3:6 using 12.5 mm graded crushed stone aggregate as in back filling ofhollow portion of frame with plain cement concrete and for fixing of hold fast complete all as specified and directed. 106 S&F pressed steel frame for door made out of MS sheet 1.25mm thick of size 105mmx60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete all as specified and directed. 107 S&F pressed steel frame for doors made out of MS sheet 1.25mm thick of size 125mmx60mm for with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete all as specified and directed. 108 S&F 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated, fitted to chowkats complete all as specified and directed. 109 S&F 35mm thick 2nd class hard wood in glazed and Skelton factory made shutters open rebated and prepared to receive glass/wire gauge etc. with sash bars edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass/wire mesh etc. sizes of members as per clause 8.24(a) of SSR Part-I complete all as specified and directed. 110 M&L for 18-20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including screed bed or bedding layer 15mm thick in cement mortar 1:4 complete all as specified and directed.Note:- The rate included for making gas pipe holes 25mm dia with rounded holes and all open edges to be half rounded. 111 Demolition of stone slabs and tiles of any description or thickness in floors/apron laid bedded and pointed in any mortar complete all as specified and directed. 112 Dismantling and taking out burnt winding by cutting, cleaningslots and re-winding of AC ceiling fan motor 1200mm of any make of fan with super enameled copper winding wire of existing gauge including, sleeve work, varnishing with E class insulation varnish, complete all as specified and directed including taking down & refixing the same.Note :- (i) Motor shall be wound with machine only. (ii) super enameled copper winding wire shall only be used. 113 Supply & fixing in replacement of old unserviceable gun metal bush of ceiling fan complete all as specified and directed. 114 Supply & fixing in replacement of old unserviceable capacitor 2.5 mfdISI marked complete all as specified. 115 All as per Srl item No. 106 here-in-above but 3.15 mfd complete all as specified. 116 Supply & fixing in replacement of old unserviceable ball bearing suitable for 1200 mm sweep of ceiling fan complete all as specified. 117 Supply & fixing in replacement of old unserviceable shackle assy kit (rubber real -01, MS split clamp two Nos, nuts and bolts washers 2 Nos & split pin -02 Nos) suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed. 118 Supply & fixing in replacement of old unserviceable fan blades, ISI Marked, suitable for 1200/1400mm sweep ceiling fan of any make complete all as specified. 119 Supply & fixing in replacement of old unserviceable MS down rod of appropriate External dia of ceiling fan complete (length of rod not less than 45cm and not more than 60cm and 15 mm dia) complete all as specified. 120 Supply & fixing in replacement Canopy for ceiling fan as per existing sample complete all as specified and directed. 121 Supply & fixing in replacement PVC Two way connector for ceiling fan complete all as specified and directed. 122 Supply & fixing in replacement of old unserviceable steel screw (to be used for fixing of fan blade) as per sample/site requirement of fan complete all as specified. 123 Servicing of ceiling fans of capacity 1200 mm sweep including taking down from site, dismantling, cleaning, greasing/oilingof bush and bearings, replacement of set of split pins, cotter pins, blade screws and refixing to the existing site after servicing complete all as directed by Engr-in-Charge. (Unserviceable parts if any will be measured and paid separately). 124 Dismantling and taking out burnt BLDC ceiling fan Driver card with Replacement to new BLDC ceiling fan Driver card of AC ceiling fan1200 mm sweep of any make of fan complete all as specified and directed including taking down & refixing the same. 125 Supply & fixing in replacement of 1200 mm BLDC ceiling fan remote suitable for as per existing fan complete all as specified and directed. 126 Supply and Fix cable PVC insulated and overall sheathed with flexible copper conductor Single core of size 1.0 sqmm complete all as specified and directed. 127 Dismantling and Re-winding of exhaust fan/industrial fan motor 250-300 mm sweep any make of fan with super enameled copper winding wire of suitable gauge as per existing including cutting and getting out old burnt winding, sleeve work, varnishing with E class insulation varnish, threading, connections fan complete all as specified and directedNote :- (i) Motor shall be wound with machine only.(ii) super enameled copper winding wire shall only be used. 128 Supply & fixing in replacement louver, suitable for exhaust fan of any make and size upto 250-300 mm, complete all as specified and directed. 129 Disconnecting the inlet/outlet water connections and electric connections of Storage type electric water heater of capacity 25 Ltrs capacity, taking down carefully from wall after unscrewing nut/bolts ,checking the outer body for any cracks and strip opening the same carefully for thorough inspection of serviceability/functionality of parts such as internal tank, syphon assembly, thermostat switch, heating element, glass wool etc, servicing complete and re-assembling and re-fixing after repair, fixing to wall testing, installation and commissioning all as directed. Note: (a) The spares required for replacement shall be measured and paid under relevant Schedule items of Sch here-in-after. 130 Supply & fixing in replacement of syphon assembly made out of SS of 25 ltr capacity including necessary studs screws and rubber gasket/washers matching with existing/new inner tank complete all as specified and directedfor carrying out repairs under relevant item No. 121 here-in-before. 131 Supply & fixing in replacement of thermostat switch ISI marked forstorage type electric water heater AC 230 volt adjustable range from 0-90 degree Celsius)for carrying out repairs under relevant item No. 121 here-in-before. 132 Supply & fixing in replacement of cup/triangulartypestorage type electric water heater element AC 230 volt, of rating 1500/2000 wattfor carrying out repairs under relevant item No.121 here-in-before. 133 Supply & fixing in replacement of indicator lamp square/roundtype suitable forstorage type electric water heater 25 ltr all as per sample AC 230 Voltfor carrying out repairs under relevant item No. 121 here-in-before. 134 Supply & fixing in replacement of cable flexible PVC insulated, PVC sheathed, copper conductor, 3 core 0.75 mm complete all as specified and directed. 135 Supply & fixing in replacement of sheet metal enclosure single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed. 136 De-scaling ofstorage type electric water heater of capacity 25 ltr after taking down thestorage type electric water heater from wall, strip opening the assembly, de-scaling the syphon assembly and refixing the assembly and re-installation ofstorage type electric water heater complete all as directed by Engineer-in –Charge. 137 Supply & fixing in replacement of safety valve/dead wt. valve ISI marked suitable for 25 Ltrs capacitystorage type electric water heaters. 138 Supply & fixing in replacement of gun metal glove or gate valves with iron wheel head, screwed both ends for iron pipe and fixed of size 15 mm. 139 Supply & fixing in replacement of anchor boltsuitable for geyser/Exhaust fan complete all as specified and directed (Note:- Anchor bolt shall be grouted with hammer drill only) 140 Supply & fixing in replacement of brass non return valve suitable for 25 ltrstorage type electric water heater of size 15 mm. 141 Disconnecting thewater connections and electric connections of Desert coolers of capacity 3000 CFM to 5000 CFM, taking down carefully from stand/ CC supports ,checking the outer body for any damage and strip opening the same carefully for thorough inspection of serviceability/functionality of parts such as fan assembly with motor (blower assly),water pump, khas khas pad , control wiring , selector switch etc, servicing complete and re-assembling and re-fixing after repair, fixing to wall testing, installation and commissioning all as directed. Note: (a) The spares required for replacement shall be measured and paid under relevant Schedule items of Sch here-in-after.(b) Any other minor spares such as nut bolts, screws, piano switch, indication lamp replacement required is deemed to beincluded in quoted rate. 142 Supply only blower motor ofsingle way shaft 240 Volts 50 c/s of suitable capacityfor desert cooler of capacity 3000 CFM to 5000 CFM single way shaft 240 Volts 50 c/s complete all as specified and directed for carrying out repairs under relevant item, complete all as specified and directed. 143 Supply only water circulation pump suitable for desert cooler of capacity 3000 CFM to 5000 CFM240 volts 50 c/s single phase complete all as specified and directed for carrying out repairs under relevant item. 144 M&L for point wiring in repair for light/fan controlled by one switch with 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor FRLS cable in existing PVC concealed conduitterminated in new anodise pressed steel sunken box having thickness not less than 2 mm with 3 mm thick ISI marked bakelite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including, cutting chiseling for concealed boxes, including insulation test of point wiring and making good disturbed surface area and white wash/colour wash to matching with the existing colour including taking down of old existing wiring any type and all as specified. Note: Colour coding is to be maintained (Ph-Red, N-Black, Half-Yellow, Earth-Green). 145 All as per item No. 136 here-in-before but for call Bell point complete all as specified and directed. 146 All as per item No. 136 here-in-before but for one 5 pin 5 Amps socket outlet independent board complete all as specified and directed. 147 All as per item No. 136 here-in-before but for one 3 pin 5 Amps socket outlet on same board complete all as specified and directed. 148 M&L for point wiring in repair for light/fan controlled by one switch with 4 Sqmm PVC insulated unsheathed multistranded copper conductor FRLS cable in existing PVC concealed conduitterminated in new anodise pressed steel sunken box having thickness not less than 2 mm with 3 mm thick ISI marked bakelite laminated sheet fixed with cadmium plated screws and washers for switches and sockets, including 4 Sqmm PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including, cutting chiseling for concealed boxes, including insulation test of point wiring and making good disturbed surface area and white wash/colour wash to matching with the existing colour including taking down of old existing wiring any type and all as specified. Note: Colour coding is to be maintained (Ph-Red, N-Black, Half-Yellow, Earth-Green). 149 S & F in replacement of switch piano flush type one way 5 Amps SP 240 Volts complete all as specified and directed. 150 S & F in replacement of switch piano flush type one way 15 Amps SP 240 Volts complete all as specified and directed. 151 S & F in replacement of socket outlet 2 in 1, 3 pin 5 amps flush type 240 Volts complete all as specified and directed. 152 S & F in replacement of socket outlet 2 in 1, 5 pin 5 and 15 amps flush type 240 Volts complete all as specified and directed. 153 S & F in replacement of switch bell push, flush type, 5 amp one way complete all as specified and directed. 154 S & F in replacement of bell electric heavy duty Ding Dong type 230 volts single pole complete and all as specified. 155 S & F in replacement ofold u/s fan regulator with fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or directed 156 S & F in replacement of fan regulator suitable for BLDC fan and connecting electrically all as required or directed 157 S & F in replacement of existing old u/s switch socket combination with socket combination Polycarbonate body, 5 pin, 5 Amp flush type with pvc box all as specified and directed. 158 S & F in replacement of existing old u/s switch socket combination with socket combination Polycarbonate body, 5 pin, 15 Amp flush type with pvc box all as specified and directed. 159 S & F in replacement of existing old u/s ceiling rose with ceiling rose Polycarbonate body surface bakelite 2 to 3 terminals, 230 volts. 160 S & F in replacement of existing old u/s lamp holder with lamp holder batten type polycarbonate body with back plate for batten fitting all as directed. 161 S & F in replacement of existing old u/ssubmain wiring with two single core PVC insulated flexible copper conductor cable of size 4 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. 162 S & F in replacement of existing old u/ssubmain wiring with two single core PVC insulated flexible copper conductor cable of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in and including concealed PVC conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed. 163 S & F in replacement of existing old u/s tube light fitting with batten type18/20 watt energy efficient tube light fittings LEDcomplete with minimum 3.5/4 feet long with all accessories prewired and making connection with copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fittings complete all as specified and directed. 164 S & F in replacement of LED Bulk head light fitting 1 X 9/10 watts cool Daylight (CDL) round type premium quality diffuser for even distribution of light complete , connecting electrically to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required. 165 S & F in replacement of existing old u/s tube light fitting with batten type10 watt energy efficient tube light fittings LEDcomplete with minimum 2 feet long with all accessories prewired and making connection with copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fittings complete all as specified and directed. 166 S & F in replacement of LED lamp 7 watt , 230 volts retrofit type complete all as specified and directed by Engr-in-charge. 167 S & F in replacement of LED lamp 15 watt , 230 volts retrofit type complete all as specified and directed by Engr-in-charge. 168 S & F in replacement of LED lamp 12 watt , 230 volts retrofit type complete all as specified and directed by Engr-in-charge. 169 S & F in replacement of sheet metal enclosure 4 way , with SPN DBs ( grouted in walls) double door type IP-43 Protection. Isolated Neutral, Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge 170 S & F in replacement of sheet metal enclosure 8 way, with SPN DBs (grouted in walls) double door type IP-43 Protection. Isolated Neutral, Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge 171 S & F in replacement of sheet metal enclosure 12 way, with SPN DBs (grouted in walls) double door type IP-43 Protection. Isolated Neutral, Door earthing, cement spill protector, IK-08 complete including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site or directed by Engr-in-Charge 172 Supply and fix in replacement of existing old u/s MCB SPN with MCB SPN , 240 volts, 32 amps, with rupturing capacity 10 KA, complete all as specified and directed by Engr-in-charge. 173 Supply and fix in replacement of existing old u/s MCB SPN with MCB SPN , 240 volts 40 amps, with rupturing capacity 10 KA, complete all as specified and directed by Engr-in-charge. 174 Supply and fix in replacement of existing old u/s MCB SPN with MCB SPN, 240 volts any rating from 63 amps, with rupturing capacity 10 KA, complete all as specified and directed by Engr-in-charge. 175 Supply and fix in replacement of existing old u/s MCB TPN with 63 amp MCB TPN, 415 volts breaking capacity 10 KA, complete all as specified and directed by Engr-in-charge. 176 Supply and fix in replacement of existing old u/s MCB TPN with 40 amp MCB TPN, 415 volts breaking capacity 10 KA, complete all as specified and directed by Engr-in-charge. 177 Supply and fix in replacement of existing old u/s MCB TPN with 32 amp MCB TPN, 415 volts breaking capacity 10 KA, complete all as specified and directed by Engr-in-charge. 178 S & F VTPN DBs Double Door4 way suitable for MCCB incomer, IP 43 protection 415 V AC, 50 Hz AC appropriate size of bus bar and neutral link complete all as specified and directed 179 M&L for Replacement of unserviceable MCCB 100 Amps current carrying capacity 16 KA , AC 415 Volts three polecomplete all as specified and directed.including dismantling the existing with all connections & fixing the new with all connections all as directed by Engg-in-charge. 180 Supply and fix in replacement MCB single pole 240 volts with rating 6 to 32 amps, with rupturing capacity 10 KA, complete all as specified and directed. 181 Supply and fix in replacement MCB single pole 240 volts with rating 40 amps, with rupturing capacity 10 KA, complete all as specified and directed. 182 Supply & fixing in repair of Hylum sheet 5x5 to 10 x 12 inches for fixing of switches, sockets etc including cutting for fixing on existing or new sunken box with brass screw complete all as specified and directed by Engr-in-charge 183 Supply & fixing in repair ofpressed steel terminal boxes (for mounting switches /sockets/ regulators/ceiling roses etc) made of not less than 16 gauge MS sheet and 6cm depth of size 4x4 to 10 x 12 inches for fixing bakelite sheet of suitable size complete all as specified and directed by Engr-in-charge 184 M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cm X6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0mm dia by means of nuts bolts, washers, check nuts of iron or steel includingPCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I. all specified. 185 S & F High performance IP66 LED Street light 35 watt, housing made of die-cast aluminium, with street optic lens, with all accessories and connecting up with and including provision of 3 core flexible copper wire of size 1.5 sqmm from ceiling rose, and 35W LED light etc. drawn through and including 32mm bore GI light grade protection pipe upto 1.5 m length with suitable fixing accessories on walls, complete all as specified and directed. 186 S & F in replacement Gang Box for 15 Amp Switch socket combined including 15 Amp combination complete all as specified and directed. 187 S & F in replacement Gang Box for 5 Amp Switch socket combined including 5 Amp combination complete all as specified and directed. 188 S & F for providing/cutting the round/square hole of required size in wall finishing the disturbed surfaces as per existing finishes complete all as specified and supply and fixing MS ventilation fans single phase, 230 volts, 225/230 mm or 9 H.D EX Fan (900 RPM) complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 1.5 Sqmm copper cable from ceiling rose to exhaust fan motor and MES No with black synthetic enamel paint 2.0 cm high complete all as specified and directed. 189 Note: (i) In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.(ii) The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum. 190 Rate quoated above items No.01 to 180 here in beforeinclusive provision as under : Making arrangement for establishment of centralized complaint centre in the existing building as under :- (a)Infrastructure required in Complaint cell i.e. computer, telephone, furniture, stationary, transport and other necessary items/materials to establish a new complaint centre able to receive and manage complaints from the users by all means ie Manual complaint mechanism, Telephonic complaints mechanism, SMS complaint Mechanism and e-mail complaint mechanism through automation tools/application i.e Service Request Tracking and Response System (STARS) developed by VYNUS SOLUTIONS and to maintain a consolidated list of complaints and its redressal mode indicating all its relevant data.(b)Computer data operator shall be able to manage all the necessary activities and having qualification as Graduate in any discipline with minimum one year certificate course of computer applications (from a Govt recognized institute), (c ) Provision and maintenance of all tools, plants, equipment and safely gear required for tradesmen under this contract (d) Provision of communication facilities to supervisor and tradesmen. (e) Monitoring and management of complaints report from generation to execution of complaint including pending complaints.(f)Updating status of lodged complaints before change of eight hour shift.(g)Provision of motorized conveyance for deployment to all tradesmen under this contract.(h)Basic inputs to be noted from the complainants will be locality, Building No, Qtr No, Name and Rank of complaint and exact nature of complaint and mobile No/ telephone 191 (j) On lodging the complaint, the Complaint No. willbe assigned for reference . Also system should indicate an approximate time for repairs.Accordingly a corresponding complaint slip shall be generated by the system with all relevant info.Complaint slip should be printed in triplicate and to be handed over immediately to Supervisor who shall detail appropriate tradesmen for repair with required materials/store. One copy of complaint shall be retained in complaint centre and two copies with tradesmen.(k)On both copies of complaint slip, status of the complaint attended shall be endorsed by the complaint/user.One copy to be retained by the complainant and second copy to be with tradesmen for handing over in the complaint centre.Reasons for non attending of complaint etc shall be recorded alongwith estimate of expected time to attend and rectifying the complaint.(l) At the end of each day, summary of complaints shall be prepared and generated indicating No of complaints lodged, attended in time, Reasons for not attending , probable time required for attending the pending complaints etc .(m) Timing of complaints will be 9:00 AM to 6:00 PM including sundays and holidays.(n)JE in charge of MES will review the complaints recorded in the system daily and will carry out personal inspectionof complaints attended and its status and will take remedial measures in this regard.(o)AGE will visit the complaint cell at least thrice a week and GE at least once a weak to check the efficacy of the system and record their remarks accordingly. Note : Contractor shall be responsible for followings:- (i)Installation of landline telephone connection with internet broadband facility, obtaining SIM cards for mobile phones for supervisor and workers, deployed by the contractor. (ii) Implementation of Bio-metric system for attendance of supervisors and workers, deployed by the contractor. (iiii)Payment of telephone bills, internet charges, mobile bills, expenses etcshall be borne by the contractor and no claim whatsoever on this account will be admissibleby the department.