| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal ofdebris and rubbish complete all as specified and directed. |
| 2 | Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal ofdebris and rubbish complete all as directed by the Engr-in-Charge |
| 3 | M & L for 25 mm thick, plain cement concrete 1:2:4,type B-0 (using 12.5 mm graded stone aggregate)as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed. |
| 4 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6complete all as specified and directed. |
| 5 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6complete all as specified and directed. |
| 6 | M & L for Glazed, ceramic, colouredtiles of size 300mm x 200mm x 6-7mm thick, on vertical surfaces such as skirting, dados etc, and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles and including 10 mm thick bedding in cement mortor 1:4 complete all as specified and directed. |
| 7 | M & L for 75 mm thick,plain cement concrete1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed. |
| 8 | M & L for 100 mm thick, Plain Cement Concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in footpath/hardstanding, etc and finishing the cement concrete surfaces even and smooth without using extra cementincluding making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed. |
| 9 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 10 | S & F MS steel work in tubular trusses including special shapedwasher etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as speicfied and directed. |
| 11 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges and keeping serviceable sheets in safe custody for reuse in the work complete as directed. |
| 12 | S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer\"s instruction complete all as specified and directed. |
| 13 | S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer\"s instruction complete all as specified and directed. |
| 14 | Demolition of brick work or stone / boulder masonry/ precast concrete block masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal ofdebris and rubbish complete all as directed by the Engr-in-Charge. |
| 15 | M & L for Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate),block masonry with solid blocks of size 300x200x200mm or 300x200x100mm, having compressive strength of not less than 100 Kg/Sq Cm (As per IS-2185) exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 16 | M & L for Providing Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) setting in mortar, complete, in walls in width and setting in mortar 1:6 complete all as specified and directed. |
| 17 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish complete all as specified and directed |
| 18 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed. |
| 19 | M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4,mixed with integral water proofing compoundwith weight of cement in top layer as per manufacturer\"s instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 20 | Supply only integral water proofing compound (ISI marked) complete all as specified and directed. |
| 21 | M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer and over one or more coats of wall care putty to a smooth surface complete all as specified and directed. |
| 22 | M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 23 | Demolition of reinforced cement concrete in any position not otherwise specifically provided for and removing rubbish complete all as specified and directed. |
| 24 | M & L for Precast reinforced cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in landing, cover slabs, shelves and similar articles with plain faces and set in CM 1:6 complete all as specified and directed.(Note: Reinforcement shall be measured and paid seperately) |
| 25 | S & F high strength TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 26 | M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed. |
| 27 | M & L for Preparation of oldpainted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed. |
| 28 | M & L for Repair to old unserviceable/jam steel gate of any size by welding of loose members, greasing and making it serviceable by fixing of loose/broken flat iron side clamps/hinges to wall/pillar etc including replacement unserviceable flat iron clamps/hinges/fasteners etc and necessary welding work complete all as specified and directed. (Note: The cost of FI clamps/hinges/fasteners etc shall deemed to be included in the unit quoted rate) |
| 29 | M & L for 30 mm thick (average thick), plain cement concrete 1:2:4,type B-0 (using 12.5 mm graded stone aggregate)as in sub-base of flooring, lovelling course etc and finished the surface even and rough including cutting the existing loose patches, roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust and applying brushing neat cement slurry with 3 Kg of cement per Sqm complete all as specified and directed. |
| 30 | M & L for applying 3mm thick high performance EPOXY Flooring over the concrete surfaces after preparation of surfaces by griding and cleaning all dirts, debris etc to achieve a sound surface, followed by by applying a coat of primer with Tech 24 of 0.1mm thick a mixer of base and hardener (as per manufacturer\"s instructions), it will be followed by a screed coat coat with Tech 60 of 1.90mm thick by mixer of base, hardener and aggregates (as per manufacturer\"s instructions), broadcasting over screed after that applying sealer coat of 0.1mm thick and and application of final top coat withTech SLE of 0.9mm thick by mixing Base, Hardener, Color paste and aggregates (as per manufacturer\"s instructions)complete all as specified and directed. (Make: Jemkon Pvt Ltd or equivalent approved makes) (Note for item No. 29 & 30: The work shall be got executed through the manufacturer or their authorized applicator. Tenderers are deemed to have entered into an agreement the manufacturer’s/applicator and a valid MOU on Non Judicial Stamp paper of Rs. 100/-shall be submitted to the Engr-in-Charge. The contractor shall provide all facilities to workmen of the applicator for carrying out the work at site without any extra cost to the Govt. All such expenses shall deemed to be included in the unit quoted rates. A MOU shall be signed by the contractor with the manufacturer/applicator to carryout the work by the applicator/manufacturer) |
| 31 | S & F 160 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed. |
| 32 | S & F 160 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 33 | Surface dressing n.exc 15 cm deep as in soft/loose soil complete all as specified and directed. |
| 34 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depthfor foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 35 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. |
| 36 | Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting pointcomplete all as specified and directed. |
| 37 | Excavating in post holes (or similar holes) each n. exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete all as specified anddirected. |
| 38 | M & L for plain Cement Concrete1:3:6, type C-2 (using 40 mm graded stone aggregate) as in post, walls, retaining walls, ballast walls and the likes any thickness, above top of footings including attached pilasters and buttreses complete all as specified and directed. |
| 39 | M & L for Rolled mild steel fo grade Fe 410-W (Gde-E- 250) quality-A as in roof trusses (framed),trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pices, cleat etc complete all as specified and directed. |
| 40 | S & F Mild steel screw bolts of 5 to 10 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm and n.exc 30cm long complete all as specified and directed. |
| 41 | S & F Rolled mild steel in Plates (plain or chequered) channels fo grade Fe 410-W (Gde-E- 250) quality-A, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as speicfied and directed. |
| 42 | M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed. |
| 43 | M & L for use & waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter complete all asspecified and directed. |
| 44 | M & L for use & waste Formwork to sides of pillars, posts, struts, piers, columns and stanchionsfor flat rough finished surfaces of concrete complete all as specified anddirected. |
| 45 | M & Lfor Reinforced Cement Concrete 1:1.5:3, type A-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in foundations including rafts, footings and mass concrete, etc complete all as specified and directed. (Note: Reinforcement will be measured and paid seperately) |
| 46 | M & L for Reinforced Cement Concrete1:1.5:3, Type A-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in columns, pillars, posts and struts complete all as specified and directed. (Note :Reinforcement will be measured & paid seperately) |
| 47 | S & F high strength Mild steel TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed. |
| 48 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 49 | M & L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed. |
| 50 | M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 51 | M & L for 100 mm thick, plain cement concrete 1:4:8,type D-2 (using 40 mm graded stone aggregate)as in sub-base of flooring, etc complete all as specified and directed. |
| 52 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 53 | M & L for glazed, coloured, ceramic, tiles of size (350mm x 250 mm/450mm x 350mm/300mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 10 mm thick bedding in cement mortor 1:4 complete all as specified and directed. |
| 54 | S & F Vitreous China White Wash Hand Basin of Size 450x300mm, Flat back including Brass Chromium plated Waste Fitting 32mm bore (dia) and PVC Waste Pipe 32mm bore (dia) of Low or High density, a Pair of Cast Iron Brackets or Erecting Stand duly Painted, Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3 but excluding Taps, Chain, Plug & Porocelain Stopper complete all as specified and as directed. |
| 55 | S & F 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered \"Hot or Cold\" with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed. |
| 56 | S & F 600mmX450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with chromiun plated brass screws and cup washers complete all as specified and directed. |
| 57 | S & F Soap dish, Vitreous china white, approximate size 160mm x 160mm x 90mm, embedded in walls/fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 58 | S & F 1000 litres capacityrotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position as specified in SSR Part I and directed. |
| 59 | S & F 20 mm bore,Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and directed. |
| 60 | S & F Towel Rack 600mm long with Lower Hangers, Chromium plated including Chromium plated brass screws and wooden/plastic cleats etc complete all as specified and directed. (Make: Jaquar Cat No. ACN-1181S or equivelant of make as per list of manufacturer\"s) |
| 61 | S & F 75 mm bore, PVC (SWR),Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc completeall as specified and directed. |
| 62 | S & F75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 63 | S & F 75mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 64 | S & F 20 mm bore, gun metal, globe or Gate valves with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 65 | S & F 15 mm bore, angular stop cock, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 66 | M & L for Mild steelframed work such as grills, gratings, gates etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-410-0 Gde E-250 complete all as specified and directed. |
| 67 | M & L for 0.63 mm thick, Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams,including bending or turning up,mitred angles, etc. asrequired complete all as specified and directed. |
| 68 | S & F15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and directed. |
| 69 | Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. |
| 70 | Supply, laying, connection and testing, 20mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed. |
| 71 | M & L for Point wiring for one light/exhaust fan/fan point/call bellcontrolled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductorcable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) |
| 72 | S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed. |
| 73 | S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed. |
| 74 | S & F LED tube light fittings, retro bar professional WH 5700K to 6000K, 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specifiedand directed. (Make: Havell\"s Cat No. LUMILINENEOBS20WLED840SPCSSIND or equivelant of make as per list of manufacturer) |
| 75 | S & F LED, 35 Watt New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 with lamp and all accessories including mounting clamps, bolts, nuts and washers, 1.5 Sqmm weather proof twin core twisted FRLS grade copper conductor cable to fittings of suitable length complete all as specified and as directed. (Make: Havell\"s Cat No. ENDURASUNDOWNSL35WLED765PASYBOPC or equivelant of make as per list of manufacturer) |
| 76 | S & F sheet metal enclosure, single door MCB DBs, phosphatised, powder coated, Single pole & neutral (SPN),02 way, 240 Volts suitable for housing MCBs with din rail, neutral and earth bar in proper psoition complete all as specified and directed. |
| 77 | S & F MCB SPN 6-32A Amps, 240 Volts,10KA, C Curve complete all as specified and as directed Havell\"s cat part No. DHMGCSNF006-032 or equivalent make as per List of Manufacturer\"s) |
| 78 | S & F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete all as specified and directed. |
| 79 | S & F 1100 volts grade, heavy duty cablePVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathedin service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, cross ectional area 10 Sqmm 2 core solid conductor complete all as specified and directed. |
| 80 | S & F House service bracket (hook type) complete with 3.0m long GI pipe 40mm dia, Medium Grade, two nos. 90 degree bends, M.S. hook and stay or guy complete all as specified and directed. |
| 81 | M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion complete all as specified and as directed by the Engineer-in-Charge. |
| 82 | M & L for Cutting existing steel tubing 40 to 100 mm bore for alteration or additions(Each cut measured) including Screwing existingsteel tubing, 40 to 100mm bore for alterations or additions (or lengthening screw on pipe to form connector) complete all as specified and directed. |
| 83 | Supply, laying, connection and testing 25mm bore, Steel water tubing, galvanised, medium grade with all fittings, laid in trenches, etc complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately) |
| 84 | Supply, laying, connection and testing 50mm bore, Steel water tubing, galvanised, medium grade with all fittings and jointing materials, laid in trenches, etc complete all as specified and directed. (Note: Excavation and earth work work shall be measured and paid seperately) |
| 85 | S & F 25 mm bore, gun metal, globe or Gate valves with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 86 | S & F 50 mm bore, gun metal, globe or Gate valves with iron wheel head, Class-I, Pressure Tested of 1.5 Mpa, screwed both ends for iron pipe complete all as specified and directed. |
| 87 | M & L for construction of brick masonry valve pit of size 75 cm x 75 cm x 75 cm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in foundation, 15mm thick rendering in cement mortar (1:4) internally, externally up to 15cm below GL, providing valve pit cover made out of 3mm thick MS sheet duly welded with provision of hinges, handle and locking arrangement including 40 x 40 x 5mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC block 1:2:4 type B-1 (20mm graded aggregate) of size 230 X 200 X 100mm, applying two coats of anti-corrosive paint over a coat of red oxide, zinc chrome primer after preparation of steel & iron surfaces including necessary excavation &earth work in soft/loose soil and demolition of existing one complete as specified and directed all as per relevant TD drawing. (Note : Drawing not attached with the tender document.However, the same can be seen in GE/AGE E/M office during working hours) |