Tender For Shri Sarswati Sansakrit U.M. School Gurvat Rajapur Cholapur Varanasi. - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. for All kinds of soil.As per DSR:Vol.1:2023 item 2.8.1 2 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete,As per DSR:Vol.1:2023 item 2.25A 3 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).As per DSR:Vol.1:2023 item 4.1.8 4 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources).As per DSR:Vol.1:2023 item 4.1.3 5 Providing and laying in position, 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources), of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.As per DSR:Vol.1:2023 item 5.1.2 6 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : in 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu- ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) as per DSR:(Vol.-1):2023 Item 5.2.2 7 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).as per DSR:(Vol.-1):2023 Item 5.3 8 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete as per DSR:(Vol.-1):2023 Item 5.9.1 9 Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform as per DSR:(Vol.-1):2023 Item 5.9.3 10 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers as per DSR:(Vol.-1):2023 Item 5.9.5 11 Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts as per DSR:(Vol.-1):2023 Item 5.9.6 12 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) as per DSR:(Vol.-1):2023 Item 6.1.2 13 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand):as per DSR:(Vol.-1):2023 Item 6.4.2 14 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and aboveplinth level of Thermo-Mechanically Treated bars of grade Fe-500D or more as per DSR:(Vol.-1):2023 Item 5.22.6 & 5.22A.6 15 Steel work in built-up section frame work i/c cutting hoisting fixing in position i/c applying primer in gratings frames gaurd gate and similar work. 10.25.2 16 Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 4.0 mm thick glass panes as per DSR:(Vol.-1):2023 Item 10.30.1 17 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) as per DSR:(Vol.-1):2023 Item 13.1.2 18 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement as per DSR:(Vol.-1):2023 Item 13.9.1 19 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement as per DSR:(Vol.-1):2023 Item 13.9.2 20 Making groove in plastered surface or moulding to R.C.C. projections.as per DSR:(Vol.-1):2023 Item 5.30 21 Providing and laying Vitrified tiles in floor in Glazed vitrified floor tiles polished finish of size600x600mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. as per DSR:(Vol.-1):2023 Item 11.41A.2.1 22 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per DSR:(Vol.-2):2023 Item 13.80 23 Distempering Two or more coats on new work with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over and including water thinnable priming coat with cement primer having VOC content less than 50 gms/litre, as per manufacturers specification. as per DSR:(Vol.-2):2023 13.41.1 24 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade on New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 Ltr/10 sqm):. as per DSR:(Vol.-2):2023 13.47.1 25 Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture as per DSR:(Vol.-2):2023 Item 13.48.3 26 Providing and fixing on wall face unplasticised 110mm dia Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as per DSR:(Vol.-2):2023 12.41.2 27 Providing and fixing on wall face unplasticised - PVC moulded 110mm Coupler fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing withseal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion as per DSR:(Vol.-1):2023 12.42.1.2 28 Providing and fixing unplasticised -PVC 110mm pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. completeas per DSR:(Vol.-1):2023 12.43.2 29 S/F of Informatory Signboard at site 30 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group c 31 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 32 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 33 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 34 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 35 Upto 450 mm sweep 36 8 way , Double door 37 Double pole 38 Supply and fixing of LED tube light with batten suitable for upto 1x22 watt LED tube light fitting complete in all respect. CAT AAA 39 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 40 Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0 mm thickISI Marked G.P.sheet spot welded Four to Eightholes for pipe entryof the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed. Fixing with wiring conduit laid in the R.C.C. roof before concretingalongwith supply of all material, labour, T&P etc. required for proper completion of the work. 41 Supply and fixing of 17 watt LED Bulb ISI make. 42 Supply of AC 380mm sweep, 230/250 volt 50Hzs Exhaust fans ISI make, i/c nut bolt etc complete.