maintenance of electronic installation in Various Nrb At Chandigarh. (Repair/ Replacement Of Security Lights And Miscellaneous Items In Police Station Sec-39 And Police Post Maloya, Ut Chandigarh Under The Jurisdiction Of Sde E-7, Chd.)-DSR 1.8 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 2 Group C 3 DSR 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 4 Group C 5 DSR Item No. 1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 6 5/6 amps switch 7 3 pin 5/6 A socket outlet 8 15/16 A switch 9 6 pin 15/16 A socket outlet 10 DSR 1.29 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. 11 DSR Item No. 1.30 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. 12 DSR Item No. 1.17 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 13 3 x 1.5 sq. mm 14 3 x 2.5 sq. mm 15 DSR 1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 16 5/6 A switch 17 3 pin 5/6 socket outlet 18 15/16 A switch 19 6 pin 15/16 socket outlet 20 DSR item No.1.21Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 21 25 mm 22 DSR 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 23 4 way (4 + 12), Double door 24 DSR 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 Single pole 26 Triple pole and neutral 27 DSR 2.16 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V C curve DP MCB complete with connections, testing and commissioning etc. as required. 28 DSR 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 29 Note: The MCCB should have adjustable overload and adjustable S/C protections ((Ics=100% of Icu). 30 125 A,36KA,FPMCCB 31 Supply & Erection of 3 mm thick white glazed bakelite sheet on existing M.S. box. The job includes the cost of sheet and making holes & cutting and fixing with screws as required to complete the job. The bakelite should be of Superhylam/Formica/ Greenlam (ISI marked) make only. 32 DSR 1.9 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency>85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temprange -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV withShort & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/cconnections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast / Extruded aluminium Body (Thickness≥ 1.20 mm)36 watt 33 S/E of 18/20 watt polycarbonate tube rod 4’ long. The tube rod should be replaced in the place of existing defective tube rods in existing tube fittings as per the various locations. The job includes the cost of petty material required at site as per the satisfaction of the EIC. 34 LED Flood Light, powder coated pressure die cast aluminum(System lumen efficacy 105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Flood Light, powdercoated pressure die cast aluminum body with built in or separate driveras per the requirement with Driver efficiency >85%, Input voltage: Inputvoltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the150 watt