Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 2 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge. |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar |
| 4 | Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead: Of area 3 sq. metes and below |
| 5 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 6 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 9 | Providing and laying in sunken floor autoclaved aerated cement brick bats filling with cement concrete1:3:6 (1 Cement: 2coarse sand : 4 graded stone aggregate 20mm nominal size),cost and conveyance of all materials, labour charges etc. complete at all levels as directed by Engineer-in-charge |
| 10 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level. Concrete of M30 grade with minimum cement content of 350 kg /cum. |
| 11 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level. Concrete of M25 grade with minimum cement content of 330 kg /cum. |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-550D |
| 13 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-550D |
| 14 | Providing fusion bonded Epoxy coating not less than 175 micron thickness and upto 300 micron to reinforcement barsof any diameter as per IS-13620-1993/ ASTM-775 M including repairs to cut ends,welded spouts and handling damages with reccomendedliquid epoxy compatible with the coating and testing of coating at plant etc complete as directed by engineer ion charge. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : Edges of slabs and breaks in floors and walls. Under 20 cm wide |
| 18 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/ 230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 19 | Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. |
| 20 | Providing and fixing 40 mm thick pre hung single leaf doorshutters consisting of an engineered door frame (Door Jamb) and architraves all wrapped, finished and supplied along with lock, latch and hinges cutting etc. Engineered Wood Jambs of 100mm size shall made from high quality fibre boards which has inbuilt properties to withstand climatic changes. It can be wrapped using Veneer and PVC foil as per the design. Veneer wrapped Jambs will be UV lacquered which protects the jambs from moisture, heat and abrasion.The rate is inclusive of all fixing accessories , Labour etc. complete as per the design and approval of Engineer in charge, |
| 21 | Providing and fixing factory made uPVC wooden colour glazedsliding doors comprising of uPVC multi-chambered frame with in-built roller track, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension,uPVC extruded interlocks and uPVC extruded Inline sash adaptor ,EPDM gasket, zinc alloy (matching colour powder coated) handle both side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (matching colour powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg),G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Twotrack Two panels made of (big series) frame having wall thickness 2.30 ± 0.2mm as per the approved drawing with fly proof mesh toughened glass pane and glazing bead of appropriate dimension. Approval of all material samples by the Architect/Engineer-In-Charge prior to procurement is mandatory. Vender must prepare shop drawing for this item based on architectural details/drawings and should take approval from Architect/Engineer-In-Charge prior to fabrication. The Rates inclusive of 6mm toughened glass Glazing,Locks,track,rollers, handle and fitting,anchor fasterners ,all required accessoriers etc complete. |
| 22 | Providing and fixing factory made uPVC wooden colourfixed window comprising of uPVCframe with , sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension,uPVC extruded interlocks and uPVC extruded Inline sash adaptor (if required),EPDM gasket, zinc alloy (matching colour powder coated) handle on one side of extreme panel along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (matching colour powder coated) touch lock with hook (if required for wire mesh panel), stainless steel (SS 304 grade) body with adjustable double nylon rollers (weight bearing capacity to be 120 kg),G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.uPVC wooden colourfixed window frame having wall thickness 2.30 ± 0.2mm as per the approved drawing and glazing. Approval of all material samples by the Architect/Engineer-In-Charge prior to procurement is mandatory. Vender must prepare shop drawing for this item based on architectural details/drawings and should take approval from Architect/Engineer-In-Charge prior to fabrication. The Rates inclusive of 6mmtoughened glass Glazing,Locks,track,rollers, handle and fitting,anchor fasterners ,all required accessoriers etc complete. |
| 23 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost and conveyance of all materials, labour charges,tool rental charges, lead,liftetc completes directed by Engineer-in-Charge at all levels. |
| 24 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work |
| 25 | Providing and supplying heavy duty injection adhesive for rebar fixing using Epoxy resin of 330/500ml HILTI HIT-RE 500 V3/or equivalent for fixing rebar.Embedment depth as mentioned from the Structural consultants, including supplying two component system consisting of resin and hardener in 3:1 ratio; filling above mentioned mortar with standard dispenser before inserting rebar strictly as per the manufacturers recommendations.The installation and the setting instructions should be strictly followed as per the manufacturers recommendations.The chemical anchor shall carry ETA, COLA and DIBT approval and fire approval. Application can be done in both wet & dry concrete condition, corrosion tested. The approved chemical shall beinstalled in hammer drill, diamond coring holes , including cost and conveyance of all materials, labour charges,tool rental charges, lead,liftetc complete as directed by Engineer-in-Charge at all levels. (The above work shall be carriedout by an agency having sufficient experience. Only skilled and experienced persons shall be employed for this purpose.) For fixing 10mm Dia bar with a hole dia of 12- 14 mm. (Excluding the cost of reinforcement ) |
| 26 | Providing and fixing high-performance galvanized steel M12 anchor rod of 125 mm length, 8.8 grade strength of approved make including cost and conveyance of all materials, labour charges, lead, lift, etc complete as directed by Engineer-in-Charge at all levels.(The above work shall be carried out by an agency having sufficient experience. |
| 27 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 28 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 29 | Providing and fixing railing with bottom aluminium channel of size 120 mm x 42 mm (5.35 KG/Mtr) of approved brand and Top Rail with SS304 Grade of size 40 x 40 x 2 mm (IM055T/equivalent)and 12 mm thick Toughened clear glass is fixed to the groove with EPDM gasket, The bottom section is fixed to the floor using Hilti/Fischer or Equvalent Chemical Anchor Bolt, The rate is including welding, grinding, buffing, polishing and fixing the railing with necessary accessories of required size, all complete as per the approved design / architectural drawing and approval of Engineer-in-charge.Railing Height – 1000 mm from FFL-Balcony Rail |
| 30 | 12mm cement plaster of mix1:4 (1 cement : 4 fine sand) including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer-in-Charge at all levels - Internal plastering |
| 31 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 32 | Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 33 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour Old work (one or more coats) |
| 34 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 35 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats |
| 36 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. |
| 37 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 38 | Providing, casting, and fixing precast concrete jali of M30 grade with reinforcement as per design, cast in approved moulds, cured, and installed in position using cement mortar and MS clamps. Includes all materials, labour, transportation, and finishing as per drawings and instructions of the Engineer-in-Charge. |
| 39 | Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately). |
| 40 | Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately). |
| 41 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 42 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size.Size of Tile 600 x 600 mm. |
| 43 | Providing and laying fully Vitrified matt tiles in different sizes (thickness to be specified by manufacturer),with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in allcolours & shade, in dadoing, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sq.m including grouting/filling thejoint with white cement & matching pigments,cost and conveyance of all materials, labour charges etc. complete at all levels as directed by Engineer-in-charge Size of Tile600x600 mm |
| 44 | Supply and installation of a custom-made Glass Reinforced Concrete (GRC) beading as per design and drawing. GRC shall be manufactured using white cement, alkali resistant glass fibre, silica sand, water with admixtures and pigmented cured with acrylic thermal plastic with dimensions as per design and Drawing. The rate shall be inclusive of moulding of any pattern as per conception design including preparing the moulds for casting, making the grc composite material, applying the material in moulds, demoulding the cured GRC elements from moulds, grinding and finishing the demoulded GRC elements, fixing at site, finishing the groves, joints with GRC mixture and application of water, oil & dirt repellent low voc protect guard with brush/roller on GRC in two coats. Applications to be done strictly as per manufacturers specification.(Note: All scaffolding materials if required shall be arranged by the contractor on his cost) |
| 45 | Supply and installation of a custom-made Glass Reinforced Concrete .GRC COLUMN CLADDING As Per Approved Shape and Dimension . GRC shall be manufactured using white cement, alkali resistant glass fibre, silica sand, water with admixtures and pigmented cured with acrylic thermal plastic with dimensions as per design and Drawing . The rate shall be inclusive of finishing with acid wash as per specification, moulding of any pattern as per conception design including preparing the moulds for casting, making the grc composite material, applying the material in moulds, demoulding the cured GRC elements from moulds, grinding and finishing the demoulded GRC elements, fixing at site, finishing the groves, joints with GRC mixture and application of water, oil & dirt repellent low voc protect guard with brush/roller on GRC in two coats. Applications to be done strictly as per manufacturers specification |
| 46 | Supply and installation of a custom-made Glass Reinforced Concrete (GRC) Makudam as per design and drawing. GRC shall be manufactured using white cement, alkali resistant glass fibre, silica sand, water with admixtures and pigmented cured with acrylic thermal plastic with dimensions as per design and Drawing. The rate shall be inclusive of moulding of any pattern as per conception design including preparing the moulds for casting, making the grc composite material, applying the material in moulds, demoulding the cured GRC elements from moulds, grinding and finishing the demoulded GRC elements, fixing at site, finishing the groves, joints with GRC mixture and application of water, oil & dirt repellent low voc protect guard with brush/roller on GRC in two coats. Applications to be done strictly as per manufacturers specification.(Note: All scaffolding materials if required shall be arranged by the contractor on his cost) |
| 47 | Procuring healthy grass free from weeds and foreign materials and laying on the soil medium as turfing,the rate include for grass cost, transport to site, cost and application of manure, planting, labour, supervision and maintenance for 2 months after plantingPearl Grass |
| 48 | Supplying , stacking and spreading sludge / well decayed farm yard manure from thesource,Mixing earth and manure or in proportion specified or directed, Spreading ofdung manure or / and good earth in required thickness.and fine dressing the ground as per natural gradiantapproved by the engineer in charge incl. screening, loading, unloading, conveyance and stacking at site. |
| 49 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 50 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-inCharge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. |
| 51 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineerin-charge). |
| 52 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 53 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 54 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 55 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 56 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 57 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 58 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 59 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 60 | 20 mm |
| 61 | 25 mm |
| 62 | 32 mm |
| 63 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 64 | 5/6 A switch |
| 65 | 2 way 5/6 A switch |
| 66 | 15/16 A switch |
| 67 | 3 pin 5/6 A socket outlet |
| 68 | 6 pin 15/16 A socket outlet |
| 69 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 70 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 71 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 72 | 1 or 2 Module (75mmX75mm) |
| 73 | 3 Module (100mmX75mm) |
| 74 | 4 Module (125mmX75mm) |
| 75 | 6 Module (200mmX75mm) |
| 76 | 8 Module (125mmX125mm) |
| 77 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way , Double door |
| 78 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 79 | 6 way (4 + 18), Double door |
| 80 | 8 way (4 + 24), Double door |
| 81 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 82 | 12 way (4 + 36), Double door |
| 83 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 84 | Single pole |
| 85 | Double pole |
| 86 | Triple pole |
| 87 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 88 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 89 | 25 A |
| 90 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 91 | 40 A |
| 92 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. |
| 93 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 94 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable PVC box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 95 | Group C |
| 96 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable PVC box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 97 | Wiring for light point/ fan point / exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copperconductorsingle core cable in surface / recessedmedium class PVC conduit,with modular switch, modular plate,suitable GI box and earthing the point with 1.5sq.mm.FRLS PVCinsulatedcopper conductor single core cable etc. as required for; |
| 98 | Two light controled by one switch. |
| 99 | S\" type M.S. fan hook fabricated from suitable dia. S.S. rod/Anger Bolt duly painted for fixing of ceiling fan. The \"S\" type hook shall be fixed to steel bar in RCC ceiling. The ceiling shall be replastered with sand, cement & neeru etc. The cost of labours for chipping out ceiling upto steel bar & fixing of \"S\" hook & resurfacing the ceiling is included in the cost of item |
| 100 | Supply of the following sizes of Ladder Type FRP cable trays with vertical sides on both ends as per approved design and FRP supports with coupler plates spaced 300mm apart throughout the length as specified, including the cost of support hooks, fasteners, painting if required etc.( Contractor shall ensure to use corrossion free materials as support or fastening fittings) |
| 101 | 150mm(150x100x25) |
| 102 | 300mm(300x100x25) |
| 103 | SITC of following Light Fixtures/Ceiling Fans / Exhaust Fans |
| 104 | LED Downlight Recessed Fitting 15 W |
| 105 | LED Downlight Recessed Fitting 12 W |
| 106 | LEDRecessedLuminaire 36Watts |
| 107 | LED Linear Fixture 20Watts 4ftSurface Mounted |
| 108 | Mirror Light 5W |
| 109 | Ceiling Fan -1200 mm ( BLDC) |
| 110 | Exhaust Fan-450 mm |
| 111 | Bollard Lights |
| 112 | 50W Flood Light |
| 113 | LED STRIP LIGHT WITH DRIVER HAVE Aluminium powder coatedPROFILE -5 Mtr |
| 114 | Supplying and fixing of 25 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 115 | Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required. |
| 116 | one run |
| 117 | Supplying and fixing of 25 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 118 | Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required. |
| 119 | 1 or 2 Module (75mmX75mm) |
| 120 | Supply and drawing of UTP 4 pair Cat 6 LAN cable in the existing surface/recessed PVC conduit as required. |
| 121 | one run |
| 122 | Supplying and drawing 2 pair, 0.5 sq mm FR PVC insulated copper conductor, un armoured telephone cable in the existing surface/recessed steel/ PVC conduit. |
| 123 | Supplying and fixing of 25 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 124 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. |
| 125 | Telephone socket |
| 126 | Supplying and fixing ofGI box of following size modules, alongwith modular base & cover plate for modular switches in recess etc as required. |
| 127 | 1 or 2 module( 75 mmx75 mm) |
| 128 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 129 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 130 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required |
| 131 | Supplying and fixing of 25 mm Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 132 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. |
| 133 | TV antenna socket outlet |
| 134 | Supplying and fixing following size/ modules,GI box along with modular base, cover plate for modular switches in recess etc as required. |
| 135 | 1 or 2 module( 75 mmx75 mm) |
| 136 | Supply, installation, testing and commissioning ofIP based IRVarifocal dome Camera, 1/3\" CMOS, 3 MP, 2.7–12 mm MFZ, night vision compatible,IR range of 40 mtrs PoE, inbuilt micro SD card,Ethernet port, H.264, IP 66, ONVIF, UL, FCC & CE certified. All mounting accessories shall be included |
| 137 | Supply, installation, testing and commissioning of 8 port- Edge PoE switch |
| 138 | Supply, installation, testing and commissioning of Patch Panel UTP Keystone- 24 Port- Fully loaded (Cat 5e,Cat 6 & Cat 6 A ) |
| 139 | Supply and installation of Cat 6 UTP patch cord, 1 mtr |
| 140 | 150mm(150x100x25) |
| 141 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. |
| 142 | RJ 45 socket |
| 143 | Supply and installation of Cat-6 shuttered 24 port patch panel |
| 144 | SITC of24 portunmanaged ethernet switch |
| 145 | Supply and installation of 9U rack withFront glass door, Rear Perforated door with handle Lock & key. Front/Rear 19\" mounting angles, top, bottom open, RAL 9005 with all other accessories |
| 146 | Supply of the following sizes of Ladder Type FRP cable trays with vertical sides on both ends as per approved design and FRP supports with coupler plates spaced 300mm apart throughout the length as specified, including the cost of support hooks, fasteners, painting if required etc.( Contractor shall ensure to use corrossion free materials as support or fastening fittings) |
| 147 | 150mm(150x100x25) |
| 148 | Supply,laying and termination of 20 pair telephone cable, 0.5mm copper PVC insulated,unarmoured telephone cable drawn in the existing cable tray |
| 149 | Supply,laying and termination of 20 pair telephone terminal block housed in engineering plastic box with transparent hinged door |
| 150 | Supply,laying and termination of 10 pair telephone cable, 0.5mm copper PVC insulated,unarmoured telephone cable drawn in the existing cable tray |
| 151 | Supply,laying and termination of 10 pair telephone terminal block housed in engineering plastic box with transparent hinged door |
| 152 | Supply of the following sizes of Ladder Type FRP cable trays with vertical sides on both ends as per approved design and FRP supports with coupler plates spaced 300mm apart throughout the length as specified, including the cost of support hooks, fasteners, painting if required etc.( Contractor shall ensure to use corrossion free materials as support or fastening fittings) |
| 153 | 150mm(150x100x25) |
| 154 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixerMake:Jaquar, Kohler, Grohe, |
| 155 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:17.7.7White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap |
| 156 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 157 | Providingandfixingstainlesssteeltoiletpaperholder. Make:Jaquar,Kohler, Grohe, |
| 158 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore.Make:Jaquar, Kohler, Grohe, Cera high end series. |
| 159 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms |
| 160 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 161 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board510x1040 mm bowl depth 250 mmMake: Jayana, Nirali, Carysil high end series. |
| 162 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore Make: Jaquar, Kohler, Grohe, Cera high end series. |
| 163 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC SDR 11) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall (Above ceiling and Ducts)Make: Astral, Supreme, Finolex, |
| 164 | 20 mm nominal outer dia Pipes |
| 165 | 25 mm nominal outer dia Pipes |
| 166 | 32 mm nominal outer dia Pipes |
| 167 | 40 mm nominal outer dia Pipes |
| 168 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.Make: Astral, Supreme, Finolex, |
| 169 | 20 mm nominal outer dia Pipes |
| 170 | 25 mm nominal outer dia Pipes |
| 171 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin counter top type 550x420mm with a 15 mm CP Brass single hole basin mixerMake:Jaquar, Kohler, Grohe, Cera high end series. |
| 172 | Fixing, Testing and Commissioning at site Wall Mounting type water closet with P trap & its all fittings like rag bolts, solid plastic Seat cover etccomplete including cutting and making good the walls and floors wherever required,Concealed flushing cisternwith brass screws,nuts , and washers complete including cutting and making good the walls and floors wherever requiredEtc complete.Queo - (Zelos Neo+CC Sisma)/ KOHLER ESCALE K16817IN-SS-0, OR Equ. |
| 173 | Providing and fixing of grab bars Vertical Swing 18-8 S, type-304, 18-gauge (1mm) stainless steel tubing with satin-finish. 1–1/4 (25mm) outside diameterwallmountedinphysicallydisabledtoiletincludingallnecessary fitting, SS Screws & Accessories etc.Complted in all manners and satisfied to of EIC.complete. Make: Jaquar, Kohler, Grohe, Hindware, Cera high end series. |
| 174 | Providing, Fixing, Testing and Commissioning at site ablution Health Spray Faucet with wall hook and 1.2 mtr. Chrome plated PVC hose pipe, etc. complete in all respects. Queo - Addons/Kohler/Grohe/jaquar |
| 175 | Providing, Fixing, testing and commissioning of Single Lever Diverter with provision for spout and over head shower with shower arm, shower rose, wall flange and spout, all accessories etc, complete.Queo - / KOHLER /Grohe Metropole, jaquar OR Equ. |
| 176 | Providing, Fixing CP Robe hook: Queo - / KOHLER/Grohe ,jaquar OR Equ. |
| 177 | Supplying,Fixing, Testing, and commissioningSink tapwall mounted/floor mounted with swivel casted spout and wall flange, trending cutting and making good the walls whatever required etc. complete Queo - Allamoda/jaquar/Kohler/Grohe |
| 178 | Supplying, Fixing, testing and commissioning at site in positionuPVC pipe -6kg/cm2) (IS:4985)Solvent Welded fittings with bosses where required e.g. tees, bends, coupling, door bends, junctions, cowls, door TEE , Door Elboe where ever required etc.,complete. (Soil & Waste in Shaft) Make: Astral/Supreme/Ajay |
| 179 | 110 mm O.D. (6Kgf/cm2 IS:4985) |
| 180 | 75 mm O.D.(6Kgf/cm2 IS:4985) |
| 181 | 63 mm O.D( 4Kgf/cm2) Vent pipe in shaft |
| 182 | Providing, Fixing, testing and commissioning at site in position uPVC pipe( IS : 4985 ) With Rubber Ring or Solvent Welded fittings with bosses where required e.g. tees, bends, coupling, etc. complete. (For Rain water pipes in shaft & Ceiling) Make: Astral/Supreme/Ajay |
| 183 | 110 mm O.D( 4Kgf/cm2)) Rain water pipe in shaft |
| 184 | Supplying, Fixing, testing and commissioning at site in position u PVC pipe of 6Kgf/cm2including PVC fittings with bosses where required e.g. tees, bends,door TEE , Door Elboe where ever requiredcoupling and adapters and jointing with adhesive approved by fitting manufactures including cutting and making good the walls and floors or surface mounted with clamps as required at site universal clamps & anchor fasteners(8mm) , threaded rod(8mm),nuts ,washers, wherever required etc. complete.Make: Astral/Supreme/Ajay |
| 185 | 50 mm O.D. (6Kgf/cm2 (IS:4985) |
| 186 | 75 mm O.D. (6Kgf/cm2 (IS:4985) |
| 187 | 110mm O.D (6Kgf/cm2 (IS:4985) |
| 188 | 32 mm O.D. (8Kgf/cm2 (IS:4985) for sunken spout |
| 189 | Supplying, Fixing, testing and commissioning at site in position Deep Seal UPvc fabricated Multi floor trap (4”), with suitable supporting on GI slotted rails (1.6mmthick) full threaded rod, anchor fasteners etc. complete in all respects.50/75 mm dia outlet (In Ceiling)Astral/Supreme/Ajay |
| 190 | Supplying,Fixing, testing and commissioning at site in position UPvc fabricated Multi floor trap (7”),with 50/75 mm dia outlet (In Sunken slab & floor raising areas)Astral/Supreme/Ajay |
| 191 | Supplying,Fixing, Testing and commissioning at site in position 150x150mm square C.P cast brass or stainless steel anti cockroach grating cover ss (304) of matching size of UPvc fabricated floor trap / multi inlet trap complete in all respects. Chilly/Eligna/ |
| 192 | Supplying,Fixing, Testing and commissioning at site in position 150x150mm square C.P cast brass or stainless steel sealed grating cover ss (304) of matching size of UPvc fabricated floor trap / multi inlet trap complete in all respects. Chilly/Eligna/ in common toilets |
| 193 | Supplying,Fixing, testing at site in position 160mm dia square /circular grating Terrace rain water outlet(Cast Iron)(for 110mm dia pipe) |
| 194 | Supplying, Fixing, testing at site in position PVC Roding Eye (6kg/cm2) Complete in all respects. |
| 195 | 110 mm dia |
| 196 | 75 mm dia |
| 197 | Providing and fixing in position cowel went to pipes.(C) 100mm dia |
| 198 | Providing, Fixing at sitein position uPVC Pipes (as per ASTMD – 1785 sch-40 ) of approved make For Cold Water Supply, complete with all necessary (ASTM D – 2466/2467) fittings (elbows, unions, tees, reducers, couplings, nipples etc) (External/ Inshaft) |
| 199 | 1 ¼ “ (32mm) dia. |
| 200 | 1 1/2 “ (40mm) dia. |
| 201 | Supplying,Fixing at site in position full way lever operated forged brass gate valve of brass body with forged brass hard crome plate (PN 10) of approved make with necessary MTA fittings in position as per drawings |
| 202 | ¾ \"\"(20mm) dia. |
| 203 | 1” (25mm)dia |
| 204 | 1 ¼ “ (32mm) dia. |
| 205 | 1 1/2 “ (40mm) dia. |
| 206 | Supply, Installation, Testing & Commissioning of 3,000 LpH Water Treatment Plant withwith all mechanical work like piping,mechanical components as follows but excluding the electrical works and civil work. a) PAC offChlorine Dosing system -1nos,Pressure sand filter FRP-1 no ,Activated carbon filter FRP-1no, |
| 207 | TERRACE DWS BOOSTER PUMP Duty Conditions of 6 lps @ 35 mtr - head(Each pump 3LPS 20 mtr Head - 2 Pump system-1 Working+1standby) Compact skid mounted Booster pumps with SS 304 casing, SS316 impeller , SS316 shaft , C I base and TEFC motorwith mechanicalseal. Pumpto be havesingle VFD logic controller. - Electriccontrol panel withlogic controller, relays, brass non return valve ,brass ball valve, calibrated pressure switch, pressuretransmitter including cabling within panel, incorporating dry run protection, potential contacts forBMS integrating , sucton and discharge headers, pressure vessal 20 ltr capacity. |
| 208 | Supply, installation, testing and commissioning of 1200 LPD Solar Water Heater with Heatingcoile Control panel with necessary controls, and other standard accessories as instructed by S-I-C. |
| 209 | Supply, installation, testing and commissioning of Recirculation pump, Inline pump with SS body with 2lps @18 meter head with standard solinoid valves, necessary piping and other standard accessories as instructed by S-I-C. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy