}

Tender For Bhairabkundabathouthansaliudalguri, Btr International Place, udalguri-Assam

Public Works Department has published Tender For Bhairabkundabathouthansaliudalguri, Btr International Place. Submission Date for this Tender is 10-07-2025. Earth Work Tenders in udalguri Assam. Bidders can get complete Tender details and download the document.




Tender Notice

49926286
Tender For Bhairabkundabathouthansaliudalguri, Btr International Place
Tender
Indian
Assam
Udalguri
10-07-2025

Tender Documents

Tender Details

Tender For BhairabkundaBathouThansaliUdalguri, BTR International Place-- 1 2.8 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding IS m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. 2 11.2 : Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. 3 4.20 A : Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregatederivedfromnaturalsourcesandusing recycledconcrete aggregate (RCA) as coarse aggregate and fine aggregate within the permissible utilization, PortlandPozzolana/OrdinaryPortland/PortlandSlagcement,admixturesin recommended proportions as per IS: 9103 to accelerate / retard setting of concrete to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. 4.20A.1 All works upto plinth level 4.20A.1.1 Concrete of M10 grade with minimum cement content of 220 kg /cum 4 5.22.1.:SteelreinforcementforR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. 5.22.1 Mild steel and Medium Tensile steel bars 5 5.1 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 6 5.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters,buttresses,plinthandstringcourses,fillets,columns,pillars,piers, abutments,postsandstrutsetc.aboveplinthleveluptofloorfivelevel, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) 7 6.1.1:BrickworkwithcommonburntclayF.P.S.(nonmodular)bricksof classdesignation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) 8 2.25(a):Excavating,supplyingandfillingoflocalearth(includingroyalty)by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 9 6.13.2 :Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) 10 13.2 : 15 mm cement plaster on rough side of single or half brick wall of mix: 13.5.1 1:4 (1 cement: 4 coarse sand) 11 9.3.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). 9.1.3 Kiln seasoned and chemically treated hollock wood 12 9.5:Providingandfixingpanelledorpanelledandglazedshuttersfordoors, windowsandclerestorywindows,fixingwithbutthingesofrequiredsizewith necessaryscrews,excludingpanellingwhichwillbepaidforseparately,all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) 9.5.1 Second class teak wood 9.5.1.2 30 mm thick shutters 13 11.3 : Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate 14 5.9 : Centering and shuttering including strutting, propping etc. and removal of form for 5.9.6Columns, Pillars, Piers, Abutments, Posts and Struts 15 5.9.21 : Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick 16 5.9.3 Suspended floors, roofs, landings, balconies and access platform 17 13.26:Providingandapplyingplasterofparisputtyof2mmthicknessover plastered surface to prepare the surface even and smooth complete. 18 13.48A : Finishing walls with 100% Premium acrylic emulsion paint having VOC lessthan 50 gm/litre and UVresistance asper IS15489:2004, Alkali& fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. 13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. 19 1.3 : Wiring for light-point/ fan point/exhaust fan point/call bell point with 2x1.5 sq. mm.FRLSP.V.C.insulatedcopperconductorsinglecorecableinsurface /recessed steel conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required. 1.3.3 Group C 20 1.24 : Supplying and fixing following modular switch/socket on the existing modular plate&switchboxincludingconnectionsbutexcludingmodularplateetc.as required 1.24.1 : 5/6 A switch 21 1.24.4 : 3 pin 5/6A Socket outlet 22 1.24.3 : 15/16A Switch 23 1.24.5 : 15/16A Socket Outlet 24 1.14 : Wiiring for circuit/submain wiring alongwith earth wire with following sizes of FRLSPVCinsulatedcopperconductor,singlecorecableinsurface/recessed medium class PVC conduit as required. 1.14.2 :2x2.5 sq.mm + 1x2.5 sq.mm earth wire 25 1.14.3 : 2x4 sq.mm + 1x4 sq.mm earth wire 26 1.14.4 : 2x6 sq.mm + 1x6 sq.mm earth wire 27 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min 350 RPM (tolerance as per IS: 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remainingaccessoriesincludingsafetypin,nutbolts,washers,temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required 28 1.27 : Supplying and fixing of following size /modules, Gl box along with modular base & cover plate for modular switches in recess etc.as required 1.28.5 : 8 Module (125mmx125mm) 29 1.27.6 : 12 Module (200mmx150mm) 30 1.28:Supplyingandfixingfollowingmodularbase&coverplateonexisting modular metal boxes etc. as required 1.28.5 : 8 module 31 1.28.6 : 12 module 32 5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required. 33 5.7 : Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, includingconnection/ termination with Gl thimble etc. as required. 34 2.3 : Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240V on surface/recess complete with thinned copper bus-bar, neutralbus-bar,eartybar,din-bar,interconnections,powderpaintedincluding earthing etc as required (But without MCB/RCCB/Isolator) 2.3.2 : 8-way, double door 35 2.12 : Supplying and fixing following rating double pole, 240V, MCB in the existing MCB DB complete with connections, testing and commissioning etc.as required 2.1 : 40A 36 2.1 : Supplying & fixing 5 Amps to 32 Amps rating 240/415 V C Curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB Complete with connections testing & commissioning etc as required. 2.10.1 : Single Pole 37 A-1 :Supplying testing of 4 ft LED Tube light batten including all accessories as directed by he department (Philips make) 38 A-2 : Supply, Testing, Commissining of 200mm sweep Ventilating fan, Exhaust fan complete as requird. Prduct ID 5116877-8122534914 39 A-3 : Supplying of following size of PVC/XLPE insulated and PVC sheathed1.1KV grade Solid aluminum conductor up to 10.sq.mm balance strnded conductor, XLPE insulated, cores laid up, PVC tap innersheathed Armour (Aluminium wire for single core up to 70 sq.mm balance luminium strip, Galvanised wire for cables up to 2x10 sq.mm,3x10 sq.mm 4x6 sq.mm and balance all galvanised steel strip) extruded PVC type ST2 sheathed 650/1100V grade as per IS 7908 (part-1) 1988 armoured U.G Cable as specified and direced by the department(Plaza or equivalent make as approved by this department) 10 sq.mm 2 core 40 A-4 : Supplying testing and commissioning of IP66 LED Street Light 60W including all accessories as direced by the Department (Wipro or equivalent make)

Key Value

Document Fees
INR 600 /-
EMD
INR 59400.0 /-
Tender Value
INR 29.70 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail