Tender For Regarding Construction Of Shed For Cows And Other Development Work In Kapila Gowshala As Per Dpr Attached -- 1 EXCAVATION FOR ROADWAY IN SOIL BY MANUAL MEANS INCLUDING LOADING IN TIPPERS AND DISPOSAL WITH ALL LIFTS AND LEAD UPTO 10 2 CONSTRUCTION OF GRANULAR SUB-BASE BY PROVIDING COARSE GRADED MATERIAL (CBR>30), SPREADING IN UNIFORM LAYERS WITH MOTOR 3 CONSTRUCTION OF DRY LEAN CEMENT CONCRETE SUB-BASE OVER A PREPARED SUB GRADE WITH COARSE AND FINE AGGREGATE CONFORMING T 4 CONSTRUCTION OF DOWEL JOINTED, PLAIN CEMENT CONCRETE PAVEMENT IN M-40 GRADE CONCRETE OVER A PREPARED SUB BASE WITH 43 O 5 MILD STEEL DOWEL BARS CONFIRMING TO IS 432, GRADE I 6 PROVIDING AND LAYING CEMENT CONCRETE WEARING COAT M-30 GRADE EXCLUDING COST OF REINFORCEMENT COMPLETE AS PER DRAWING AN 7 PROVIDING & FIXING 20 MM THICK & 25CM DEEP COMPRESSIBLE FIBRE BOARD IN EXPANSION JOINT COMPLETE AS PER DRAWING & TECHNIC 8 ALL KINDS OF SOIL 9 CEMENT CONCRETE GRADE M-10 (NOMINAL MIX) WITH 40 MM MAXIMUM SIZE OF STONE AGGREGATE 10 CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE. 11 CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE. 12 REINFORCED CEMENT CONCRETE WORK IN BEAMS, SUSPENDED FLOORS, ROOFS HAVING SLOPE UP TO 15° LANDINGS, BALCONIES, SHELVES, 13 MILD STEEL AND MEDIUM TENSILE STEEL BARS. 14 FOUNDATIONS, FOOTINGS, BASES OF COLUMNS, ETC. FOR MASS CONCRETE. 15 LINTELS, BEAMS, PLINTH BEAMS, GIRDERS, BRESSUMERS AND CANTILEVERS. 16 SUSPENDED FLOORS, ROOFS, LANDINGS, BALCONIES AND ACCESS PLATFORM. 17 BRICK WORK WILL WELL BURNT OPEN BHATTA BRICKS CRUSHING STRENGTH NOT LESS THAN 25KG/CM² AND WATER ABSOPTION NOT MORE THAN 18 1:4 (1 CEMENT: 4 SAND) 19 MOORUM/HARD COPRA 20 SAL WOOD 21 35 MM THICK SHUTTERS 22 POWDER COATED ALUMINIUM (MINIMUM THICKNESS OF POWDER COATING 50 MICRON) 23 WITH FLOAT GLASS PANES OF 4.0 MM THICKNESS 24 IN GRATINGS, FRAMES, GUARD BAR, LADDER, RAILINGS, BRACKETS, GATESAND SIMILAR WORKS. 25 12 MM THICK PRE-LAMINATED PARTICLE BOARD (DECORATIVE LAMINATION ON BOTH SIDES) GRADE 26 PAINTING WOOD WORK WITH DELUXE MULTI SURFACE PAINT OF REQUIRED SHADE. TWO OR MORE COAT APPLIED @0.90 LTR/10 SQM 27 PROVIDING AND APPLYING PLASTER OF PARIS PUTTY OF 2 MM THICKNESS OVER PLASTERED SURFACE TO PREPARE THE SURFACE EVEN AND S 28 TWO OR MORE COATS ON WALLS APPLIED @ 1.25 LTR/10 SQM. OVER AND INCLUDING ONE COAT OF SPECIAL PRIMER APPLIED 29 PROVIDING AND FIXING IST QUALITY CERAMIC GLAZED WALL TILES CONFORMING TO IS: 15622 (6 TO 7MM THICK) OF APPROVED MAKE I 30 KOTA STONE SLABS 25MM THICK IN RISERS OF STEPS, SKIRTING,DADO AND PILLARS LAID ON 12MM (AVERAGE) THICK CEMENT MORTAR 1: 31 460X915 MM BOWL DEPTH 178MM. 32 40MM DIA 33 110 MM DIAMETER (MINIMUM WALL THICKNESS 3.2MM) 34 40 MM NOMINAL OUTER DIA .PIPES. 35 15 MM NOMINAL OUTER DIA .PIPES. 36 40 MM NOMINAL BORE 37 15 MM NOMINAL BORE 0.40KG 38 WHITE VITREOUS CHINA DUAL PURPOSE WC PAN WITH WHITE SOLID PLASTIC SEAT AND LID WITH WHITE VITREOUS CHINA FLUSHING CISTE 39 100MM DIA 40 BOTTLE TRAP 31MM SINGLE PIECE MOULDED WITH HEIGHT OF 270MM, EFFECTIVE LENGTH OF TAIL PIPE 260MM FROM THE 41 PROVIDING AND FIXING 100 MM SAND CAST IRON GRATING FOR GULLY TRAP. 42 WITH MODULAR BRICKS 43 IN GRATINGS, FRAMES, GUARD BAR, LADDER, RAILINGS, BRACKETS, GATESAND SIMILAR WORKS. 44 SAND CAST IRON S&S PIPE AS PER IS : 1729 45 SAND CAST IRON S&S AS PER IS - 1729 46 PROVIDING AND PLACING ON TERRACE AT ALL FLOOR POLYETHYLENE WATER STORAGE TANK ISI : 12701 MARKED WITH COVER AND SUITABL 47 MAIN SWITCH ICTP 16 AMP RENOWNED MAKE 48 WOODEN BOARD 12 X 18 49 30X20X15 CMS. 50 16 SQ.MM.(XLPE) ARMOURED 3 CORE 51 4X2.5 SQ.MM. 52 ALL KINDS OF SOIL 53 FILLING BY AVAILABLE EXCAVATED EARTH (EXCLUDING ROCK) IN TRENCHES, PLINTH, SIDES OF FOUNDATIONS ETC. IN LAYERS NOT EXCE 54 MOORUM/HARD COPRA 55 CEMENT CONCRETE GRADE M-10 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE 56 UPTO PLINTH LEVEL 57 ABOVE PLINTH UPTO FLOOR 2 LEVEL 58 MILD STEEL AND MEDIUM TENSILE STEEL BARS. 59 FOUNDATIONS, FOOTINGS, BASES OF COLUMNS, ETC. FOR MASS CONCRETE. 60 COLUMNS, PILLARS, PIERS, ABUTMENTS, POSTS AND STRUTS. 61 WALLS (ANY THICKNESS) INCLUDING ATTACHED PILASTERS, BUTTERESSES, PLINTH AND STRING COURSES ETC 62 PROVIDING & FIXING NON-ASBESTOS HIGH IMPACT POLYPROPYLENE REINFORCED CEMENT 6 MM THICK CORRUGATED SHEETS (AS PER IS: 14 63 SUPPLY & INSTALLATION OF PRECOATED GALVANISED IRON PROFILE SHEETS (SIZE, SHAPE AND PITCH OF CORRUGATION AS APPROVED BY 64 HOT FINISHED WELDED TYPE TUBES. 65 STRUCTURAL STEEL WORK RIVETED, BOLTED OR WELDED IN BUILT UP SECTIONS, TRUSSES AND FRAMED WORK, INCLUDING CUTTING, HOIST 66 ON STEEL WORK 67 400 MM DIA PILES 68 UPTO PLINTH LEVEL 69 ABOVE PLINTH UPTO FLOOR 2 LEVEL 70 MILD STEEL AND MEDIUM TENSILE STEEL BARS. 71 COLUMNS, PILLARS, PIERS, ABUTMENTS, POSTS AND STRUTS. 72 CEMENT MORTAR 1:4(1 CEMENT : 4 COARSE SAND) 73 1:3 (1 CEMENT: 3 SAND) 74 IN STRINGERS, TREADS, LANDINGS ETC. OF STAIR CASES INCLUDING USE OF CHEQUERED PLATE WHEREVER REQUIRED, ALL CO 75 STRUCTURAL STEEL WORK RIVETED, BOLTED OR WELDED IN BUILT UP SECTIONS, TRUSSES AND FRAMED WORK, INCLUDING CUTTING, HOIST 76 TWO OR MORE COATS ON WALLS APPLIED @ 1.25 LTR/10 SQM. OVER AND INCLUDING ONE COAT OF SPECIAL PRIMER APPLIED 77 PAINTING STEEL WORK WITH DELUXE MULTI SURFACE PAINT TO GIVE AN EVEN SHADE. TWO OR MORE COAT APPLIED @0.90 LTR/ 78 ALL KINDS OF SOIL 79 FILLING BY AVAILABLE EXCAVATED EARTH (EXCLUDING ROCK) IN TRENCHES, PLINTH, SIDES OF FOUNDATIONS ETC. IN LAYERS NOT EXCE 80 CEMENT CONCRETE GRADE M-10 (NOMINAL MIX) WITH 40 MM MAXIMUM SIZE OF STONE AGGREGATE 81 WALLS (ANY THICKNESS) INCLUDING ATTACHED PILASTERS, BUTTERESSES, PLINTH AND STRING COURSES ETC 82 SUSPENDED FLOORS, ROOFS, LANDINGS, BALCONIES AND ACCESS PLATFORM. 83 LINTELS, BEAMS, PLINTH BEAMS, GIRDERS, BRESSUMERS AND CANTILEVERS. 84 COLUMNS, PILLARS, PIERS, ABUTMENTS, POSTS AND STRUTS. 85 MOORUM/HARD COPRA 86 CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE. 87 HOT ROLLED DEFORMED BARS 88 50 MM NOMINAL BORE 89 50 MM NOMINAL OUTER DIA .PIPES. 90 ALL KINDS OF SOIL 91 FILLING BY AVAILABLE EXCAVATED EARTH (EXCLUDING ROCK) IN TRENCHES, PLINTH, SIDES OF FOUNDATIONS ETC. IN LAYERS NOT EXCE 92 MOORUM/HARD COPRA 93 300 MM DIA PILES 94 CEMENT CONCRETE GRADE M-10 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE 95 CEMENT CONCRETE GRADE M-25 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE 96 CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE. 97 CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE. 98 MILD STEEL AND MEDIUM TENSILE STEEL BARS. 99 FOUNDATIONS, FOOTINGS, BASES OF COLUMNS, ETC. FOR MASS CONCRETE. 100 WALLS (ANY THICKNESS) INCLUDING ATTACHED PILASTERS, BUTTERESSES, PLINTH AND STRING COURSES ETC 101 HOT FINISHED SEAMLESS TYPE TUBES. 102 WITH READY MIXED RED OXIDE ZINC CHROMATE PRIMER OF APPROVED BRAND AND MANUFACTURE 103 ON STEEL WORK 104 LIGHT POINT/FAN POINTS. SHORT POINT 105 LIGHT POINT/FAN POINTS. MEDIUM POINT 106 LIGHT POINT/FAN POINTS. LONG POINT 107 400 WATT 108 25 WATT 109 305MM SWEEP(FRESH AIR FAN) 110 CEILING FAN (ENERGY SAVER 50 W)-1200 MM SWEEP 111 6 AMP 250 VOLT 3 PIN PB 112 SUPPLYING AND FIXING AS PER SPECIFICATION BAKELITE PENDENT HOLDER OFAPPROVED MAKE INCLUDING FLEXIBLE CORD UP TO 3 METE 113 ALL KINDS OF SOIL 114 CEMENT CONCRETE GRADE M-10 (NOMINAL MIX) WITH 40 MM MAXIMUM SIZE OF STONE AGGREGATE 115 CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE. 116 CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE. 117 REINFORCED CEMENT CONCRETE WORK IN BEAMS, SUSPENDED FLOORS, ROOFS HAVING SLOPE UP TO 15° LANDINGS, BALCONIES, SHELVES, 118 MILD STEEL AND MEDIUM TENSILE STEEL BARS. 119 FOUNDATIONS, FOOTINGS, BASES OF COLUMNS, ETC. FOR MASS CONCRETE. 120 LINTELS, BEAMS, PLINTH BEAMS, GIRDERS, BRESSUMERS AND CANTILEVERS. 121 SUSPENDED FLOORS, ROOFS, LANDINGS, BALCONIES AND ACCESS PLATFORM. 122 SUSPENDED FLOORS, ROOFS, LANDINGS, BALCONIES AND ACCESS PLATFORM. 123 BRICK WORK WILL WELL BURNT OPEN BHATTA BRICKS CRUSHING STRENGTH NOT LESS THAN 25KG/CM² AND WATER ABSOPTION NOT MORE THAN 124 1:4 (1 CEMENT: 4 SAND) 125 MOORUM/HARD COPRA 126 SAL WOOD 127 35 MM THICK SHUTTERS 128 POWDER COATED ALUMINIUM (MINIMUM THICKNESS OF POWDER COATING 50 MICRON) 129 WITH FLOAT GLASS PANES OF 4.0 MM THICKNESS 130 IN STRINGERS, TREADS, LANDINGS ETC. OF STAIR CASES INCLUDING USE OF CHEQUERED PLATE WHEREVER REQUIRED, ALL CO 131 12 MM THICK PRE-LAMINATED PARTICLE BOARD (DECORATIVE LAMINATION ON BOTH SIDES) GRADE 132 PAINTING WOOD WORK WITH DELUXE MULTI SURFACE PAINT OF REQUIRED SHADE. TWO OR MORE COAT APPLIED @0.90 LTR/10 SQM 133 PROVIDING AND APPLYING PLASTER OF PARIS PUTTY OF 2 MM THICKNESS OVER PLASTERED SURFACE TO PREPARE THE SURFACE EVEN AND S 134 FINISING WITH DELUXE MULTI SURFACE PAINT SYSTEM @1.25LTR/10 SQM 135 PROVIDING AND FIXING IST QUALITY CERAMIC GLAZED WALL TILES CONFORMING TO IS: 15622 (6 TO 7MM THICK) OF APPROVED MAKE I 136 KOTA STONE SLABS 25MM THICK IN RISERS OF STEPS, SKIRTING,DADO AND PILLARS LAID ON 12MM (AVERAGE) THICK CEMENT MORTAR 1: 137 460X915 MM BOWL DEPTH 178MM. 138 40MM DIA 139 110 MM DIAMETER (MINIMUM WALL THICKNESS 3.2MM) 140 40 MM NOMINAL OUTER DIA .PIPES. 141 15 MM NOMINAL OUTER DIA .PIPES. 142 40 MM NOMINAL BORE 143 15 MM NOMINAL BORE 0.40KG 144 WHITE VITREOUS CHINA DUAL PURPOSE WC PAN WITH WHITE SOLID PLASTIC SEAT AND LID WITH WHITE VITREOUS 145 100MM DIA 146 BOTTLE TRAP 31MM SINGLE PIECE MOULDED WITH HEIGHT OF 270MM, EFFECTIVE LENGTH OF TAIL PIPE 260MM FROM THE 147 PROVIDING AND FIXING 100 MM SAND CAST IRON GRATING FOR GULLY TRAP. 148 WITH MODULAR BRICKS 149 IN GRATINGS, FRAMES, GUARD BAR, LADDER, RAILINGS, BRACKETS, GATESAND SIMILAR WORKS. 150 SAND CAST IRON S&S PIPE AS PER IS : 1729 151 SAND CAST IRON S&S AS PER IS - 1729 152 PROVIDING AND PLACING ON TERRACE AT ALL FLOOR POLYETHYLENE WATER STORAGE TANK ISI : 12701 MARKED WITH COVER AND SUITABL 153 MAIN SWITCH ICTP 16 AMP RENOWNED MAKE 154 SINGLE PHASE METER 155 30X20X15 CMS. 156 16 SQ.MM.(XLPE) ARMOURED 3 CORE 157 4X2.5 SQ.MM. 158 LIGHT POINT/FAN POINTS. SHORT POINT 159 LIGHT POINT/FAN POINTS. MEDIUM POINT 160 LIGHT POINT/FAN POINTS. LONG POINT 161 400 WATT 162 25 WATT 163 300MM SWEEP 164 CEILING FAN (ENERGY SAVER 50 W)-1200 MM SWEEP 165 6 AMP 250 VOLT 3 PIN PB 166 SUPPLYING AND FIXING AS PER SPECIFICATION BAKELITE PENDENT HOLDER OFAPPROVED MAKE INCLUDING FLEXIBLE CORD UP TO 3 METE 167 ALL KINDS OF SOIL 168 CEMENT CONCRETE GRADE M-10 (NOMINAL MIX) WITH 40 MM MAXIMUM SIZE OF STONE AGGREGATE 169 CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE. 170 MILD STEEL AND MEDIUM TENSILE STEEL BARS. 171 FOUNDATIONS, FOOTINGS, BASES OF COLUMNS, ETC. FOR MASS CONCRETE. 172 MOORUM/HARD COPRA 173 HOT FINISHED WELDED TYPE TUBES. 174 STRUCTURAL STEEL WORK RIVETED, BOLTED OR WELDED IN BUILT UP SECTIONS, TRUSSES AND FRAMED WORK, INCLUDING CUTTING, HOIST 175 PROVIDING AND FIXING BOLTS INCLUDING NUTS AND WASHERS COMPLETE. 176 EXTRA FOR PROVIDING AND FIXING WIND TIES OF 40X 6MM FLAT IRON SECTION. 177 0.80MM THICK WITH ZINC COATING NOT LESS THAN 275GM/M² 178 PROVIDING AND FIXING TO THE INLET MOUTH OF RAIN WATER PIPE CAST IRON GRATING 15 CM DIAMETER AND WEIGHING NOT LESS THAN 4 179 SUPPLY & INSTALLATION OF PRECOATED GALVANISED IRON PROFILE SHEETS (SIZE, SHAPE AND PITCH OF CORRUGATION AS APPROVED BY 180 75MM DIAMETER 181 ALL KINDS OF SOIL 182 CEMENT CONCRETE GRADE M-10 (NOMINAL MIX) WITH 40 MM MAXIMUM SIZE OF STONE AGGREGATE 183 CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE. 184 MILD STEEL AND MEDIUM TENSILE STEEL BARS. 185 FOUNDATIONS, FOOTINGS, BASES OF COLUMNS, ETC. FOR MASS CONCRETE. 186 BRICK WORK WILL WELL BURNT OPEN BHATTA BRICKS CRUSHING STRENGTH NOT LESS THAN 25KG/CM² AND WATER ABSOPTION NOT MORE THAN 187 1:4 (1 CEMENT: 4 SAND) 188 TWO OR MORE COATS ON WALLS APPLIED @ 1.25 LTR/10 SQM. OVER AND INCLUDING ONE COAT OF SPECIAL PRIMER APPLIED 189 MOORUM/HARD COPRA 190 HOT FINISHED WELDED TYPE TUBES. 191 STRUCTURAL STEEL WORK RIVETED, BOLTED OR WELDED IN BUILT UP SECTIONS, TRUSSES AND FRAMED WORK, INCLUDING CUTTING, HOIST 192 PROVIDING AND FIXING BOLTS INCLUDING NUTS AND WASHERS COMPLETE. 193 EXTRA FOR PROVIDING AND FIXING WIND TIES OF 40X 6MM FLAT IRON SECTION. 194 0.80MM THICK WITH ZINC COATING NOT LESS THAN 275GM/M² 195 PROVIDING AND FIXING TO THE INLET MOUTH OF RAIN WATER PIPE CAST IRON GRATING 15 CM DIAMETER AND WEIGHING NOT LESS THAN 4 196 SUPPLY & INSTALLATION OF PRECOATED GALVANISED IRON PROFILE SHEETS (SIZE, SHAPE AND PITCH OF CORRUGATION AS APPROVED BY 197 75MM DIAMETER 198 PORVIDING,ERECTING, TESTING AND COMMISSIONING SOLAR STREET LIGHT SYSTEM ON 80 MM HEAVY DUTY GALVANISED IRON PIPE 6 METE 199 PROVIDING AND ERECTION OF 12.5 METER HIGH MAST LIGHTING SYSTEM SUITABLE TO INSTALL 8 NO. 150 W LED FLOOD LIGHT FITTING 200 DESIGNING & CASTING OF OPEN RAFT SHALLOW FOOTING FOUNDATION WITH M-20 CEMENT CONCRETE SUITABLE FOR 12.5MTRS. HIGH MAST 201 150W, 202 10 SQ.MM.(XLPE) ARMOURED 4 CORE 203 ALL KINDS OF SOIL 204 CEMENT CONCRETE GRADE M-10 (NOMINAL MIX) WITH 40 MM MAXIMUM SIZE OF STONE AGGREGATE 205 CEMENT CONCRETE GRADE M-20 (NOMINAL MIX) WITH 20 MM MAXIMUM SIZE OF STONE AGGREGATE. 206 MILD STEEL AND MEDIUM TENSILE STEEL BARS. 207 WALLS (ANY THICKNESS) INCLUDING ATTACHED PILASTERS, BUTTERESSES, PLINTH AND STRING COURSES ETC 208 LIGHT POINT/FAN POINTS.SHORT POINT 209 LIGHT POINT/FAN POINTS.MEDIUM POINT 210 LIGHT POINT/FAN POINTS.LONG POINT 211 3 METER HEIGHT 212 5 METER HEIGHT 213 40 WATT. 214 3 X 1.5 SQ MM 215 SUPPLYING, FIXING,TESTING & COMMISSIONING WALL / FLOOR MOUNTED LT PANEL PRIMER COATED WITH TWO COAT OF ENAMEL PAINT & P 216 DIGITAL AMPERE METER WITH CTS WITH SELECTOR SWITCH 217 DIGITAL VOLT METER WITH SELECTOR SWITCH & HRC FUSE 218 FREQUENCY METER 219 ALUMINIUM BUS BAR STRIPS WITH PVC SLEEVES 220 LED LAMPS 221 CURRENT RATING -25 TO100 AMPS & 70% -100% ADJUSTABLE 222 CURRENT RATING -160 AMPS & 70% -100% ADJUSTABLE 223 CURRENT RATING -160 AMPS & ADJUSTABLE: 70% -100% THERMAL & 5-10 TIMES MAGNETIC SETTING 224 CURRENT RATING -250 AMPS & ADJUSTABLE: 70% -100% THERMAL & 5-10 TIMES MAGNETIC SETTING 225 6 AMP TO 32 AMP RATING 226 6 AMP TO 32 AMP RATING DOUBLE POLE (DP) 227 6 AMP TO 32 AMP RATING FOR TRIPLE POLE & NEUTRAL(TPN) 228 50 AMP TO 63 AMP RATING FOUR POLE(FP) 229 50.00MM OUTSIDE DIA. 230 110.00MM OUTSIDE DIA. 231 6 SQ.MM.(XLPE) UNARMOURED 4 CORE 232 6 SQ.MM.(XLPE) ARMOURED 4 CORE 233 10 SQ.MM.(XLPE) ARMOURED 4 CORE 234 25 SQ.MM(XLPE) ARMOURED 4 CORE 235 35 SQ.MM(XLPE) ARMOURED 4 CORE 236 150 SQ.MM.(XLPE) ARMOURED 3½ CORE 237 LAYING OF ONE NUMBER PVC INSLUATED AND PVC SHEATED POWER CABLE OF 1.1KV GRADE OF SIZE NOT EXCEEDING 25 SQ.MM DIRECT IN 238 LAYING OF ONE NUMBER PVC INSLUATED AND PVC SHEATED POWER CABLE OF 1.1KV GRADE OF SIZE NOT EXCEEDING 25 SQ.MM DIRECT IN 239 LAYING OF ONE NUMBER PVC INSLUATED POWER CABLE OF 1.1.KV GRADE OF SIZE EXCEEDING 25SQ.MM BUT NOT EXCEEDING 120 SQ.MM DI 240 PROVIDING AND FIXING EARTHING ARRANGEMENT WITH 16MM DIA 2.5 METER LONG GALVANIZED IRON OR STEEL ROD ELECTRODE INCLUDING 241 PROVIDING & FIXING 25MM X 5MM G.I.STRIP IN40MM DIA G.I. PIPE(BCLASS) FROM EARTH ELECTRODE AS REQUIRED. 242 SUPPLYING AND LAYING 6 SWG G.I. WIRE AT 0.5METER BELOW GROUNDLEVEL AS CONDUCTOR EARTH ELECTRODE INCLUDING SOLDERING ET 243 GLAND SIZE 22MM SUITABLE FOR CABLE 2,3,3½ & 4 X UPTO 6SQ.MM 244 GLAND SIZE 22MM SUITABLE FOR CABLE 2,3, 3½, 4 X 10 SQ.MMOR 2X 16 SQ.MM 245 GLAND SIZE 32MM SUITABLE FOR CABLE 2,3, 3½, 4 X 25 SQ.MMOR 2,3, 3½ X 35 SQ.MM OR 2,3 X 50 SQ.MM. 246 GLAND SIZE 50 MM SUITABLE FOR CABLE 3½ X 150 SQ.MM OR3 X 185 SQ.MM 247 2.5 TO 6.00 SQ.MM 248 10.00 SQ.MM 249 6MM TO 16 SQ.MM 250 25 SQ.MM 251 35 SQ.MM 252 LUGS:- 150 SQ.MM. 253 ALUMINUM LUGS PIN TYPE UPTO 16 SQ.MM CONDUCTOR SIZE 254 ASTRO TIME SWITCH-FOR LIGHTS ON – OFF BASED ON SUNRISE & SUNSET TIMING SUPPLY, INSTALLATION, TESTING AND COMMISSIONING 255 SUPPLY AND FIXING OF IP 65 SURFACE GROUND MOUNTED LUMINARY FITTED WITH 700MA 11W LED BOLLARD WITH 8D 256 SUPPLY AND FIXING OF IP66 PROTECTED ALUMINIUM INSTANT OUTLINE DIRECT VIEW DIFFUSE 3000K-5000K WITH BACK PROFILE WITH INT 257 BACK FILLING BEHIND THE FACING ELEMENT IN REINFORCED EARTH WALLS WITH APPROVED MATERIAL/SELECTED SOIL HAVING CBR >12 (UN 258 FILLING BY AVAILABLE EXCAVATED EARTH (EXCLUDING ROCK) IN TRENCHES, PLINTH, SIDES OF FOUNDATIONS ETC. IN LAYERS NOT EXCE 259 SURFACE DRASSING OF GROUND I/C REMOVING VEGETATION SORI-2.6.1 260 MOORUM/HARD COPRA 261 1:3:6 OR RICHER MIX 262 DEMOLISHING R.C.C. WORK MANUALLY/ BY MECHANICAL MEANS INCLUDING STACKING OF STEEL BARS AND DISPOSAL OF UNSERVICEABLE MAT 263 EXTRA FOR CUTTING REINFORCEMENT BARS MANUALLY/BY MECHANICAL MEANS IN R.C.C. (PAYMENT SHALL BE MADE ON THE CROSS SECTION 264 IN CEMENT MORTAR 265 G.S. SHEET 266 DISMANTLING STONE SLAB FLOORING LAID IN CEMENT MORTAR INCLUDING STACKING OF SERVICEABLE MATERIAL AND DISPOSAL OF UNSERVI 267 EXTRA FOR MARKING OF STRUCTURAL STEEL WORK REQUIRED TO BE RE-ERECTED. 268 PROVIDING AND FIXING BOLTS INCLUDING NUTS AND WASHERS COMPLETE. 269 PROVIDING AND FIXING M.S. ROUND HOLDING DOWN BOLTS WITH NUTS AND WASHER PLATES COMPLETE. 270 PROVIDING AND FIXING M.S. RIVETS OF SIZES IN POSITION. 271 WELDING BY GAS OR ELECTRIC PLANT INCLUDING TRANSPORTATION OF PLANT AT SITEETC. COMPLETE. 272 BIOGAS PLANT (1000 CUB) 273 COW CREMATION FURNACE ( MORE THEN 1000 KG) 274 SOLAR PANAL 25 KW 275 16 CCTV IP CAMERA FULL SET WITH 16 CHANNEL 4K NVR, 16 X 2MP BULLET IP CAMERA, 16 PORT POE SWITCH, 2TB HDD, RJ45, COBOX, 276 ADD EXTRA FOR USING SALT AND CHARCOAL / COKE FOR G.I. PLATE OR COPPER PLATE EARTH ELECTRODE AS REQUIRED INCLUDING EXCAV