}

Tender For Covering Of Wrestling Akhara At Domana, Jammu-Jammu And Kashmir

Jammu And Kashmir State Sports Council has published Tender For Covering Of Wrestling Akhara At Domana. Submission Date for this Tender is 21-07-2025. Earth Work Tenders in Jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

49905258
Tender For Covering Of Wrestling Akhara At Domana
Tender
Indian
Jammu And Kashmir
Jammu
21-07-2025

Tender Documents

Tender Details

Tender For Covering Of Wrestling Akhara At Domana- 1 Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:. All kinds of soil 2 Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge.All kinds of soil : 3 Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix) 4 Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar 5 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 6 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 7 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement withl 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 8 Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 9 Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 10 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more 11 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases for columns 12 Centering and shuttering including strutting, propping etc. and removal of form for Lintel, beams, plinth beams, girders, bressumers and cantilevers. 13 Centering and shuttering including strutting, propping etc. and removal of form forColumns, pillars, piers, abutments, posts and struts. 14 Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) 15 Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level 16 12mm Cement plaster of mix 1 : 6 ( 1 cement : 6 fine sand) 17 Finishing wall with premium acrylic smooth exterior paint with siliconeadditives of required shade on New work (two or more coats applied @ 1.43 liter/10sqm over and including priming coat of water exterior paint applied @ 2.20kg/10sqm) 18 Providing and laying FULL BODY vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm ANIT SKID 19 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.In colour such as White, Ivory, Grey, Fume Red Brown 20 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 21 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 22 Painting with synthetic enamel paint of approved brand and manufacture to give an even shadeTwo or more coats on new work 23 Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as perIS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of he sheet and polyester top coat 15-18 microns. Sheet should haveprotective guard film of 25 microns minimum to avoid scratches duringtransportation and should be supplied in single length upto 12 metre or asdesired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost ofpurlins, rafters and trusses and including cutting to size and shape wherever required. (TATA / JSW or Equivalent) 24 Providing and fixing precoated galvanised steel sheet roofingaccessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxyprimer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter .(600 mm over all girth 25 Providing and fixing precoated galvanised steel sheet roofingaccessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxyprimer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm 26 Providing and fixing tiled False Ceiling of specified materials of size595x595mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms/sqm both side inclusive ) consisting of main “T” runner with suitably spaced jointsto get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200 mm center to center and cross “T” of size24x25 mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200 x600mm and secondary cross “T” of length 600mm and size 24x25 mmmade of 0.30mm thick (minimum) sheet to be interlocked at middle of the1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.30mm and laying false ceiling tiles of approved texture in thegrid including, wherever, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T”runners to be suspended from ceiling using GI slotted cleats of size27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dashfasteners, 4mm GI adjustable rods with galvanized butterfly level clips ofsize 85x30x0.8 mm spaced at 1200mm center to center along size85x30x0.8 mm spaced at 1200mm center to center along main T, bottomexposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawingsand as directed by Engineer-in-charge. 8mm mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard manufactured from naturalgypsum as per IS 2095 part-I and laminated with white 0.16mm thick fireretardant PVC film on the face side and 12micron metalized polyester onthe back side with all edges sealed with the face side PVC film which goesaround and wraps the edges and is bonded to the edges and the back sidemetalized polyester film so as to make the tile a completely sealed unit. 27 Providing and fixing aluminium work for doors, windows, ventilatior and partion with extruded built up standard tubular section,Z section and other sections of approved make and ISI 1285, fixed with dash fasteners of required dia and size including necessary filling up the gaps at the junction i.e.0top, bottom and sides with required EPDM rubber I neoprene gasket felt etc. Aluminium section shall be smooth,rust free, straight,mitred and jointed mechanical wherever required including cleat angle, aluminium snap beading for l panelling,C.P.brass stainless steel screws,all complete,For fixed portion . Powder coated aluminium. 28 For shutters of doors, windows & ventilators including providing and fixing hinges l pivot and making provision and fixing of fittings wherever required including the cost of EPDM rubber gasket required. 29 Providing and fixing 4 mm thick ACP Sheet in panelling fixed in aluminum doors, windows shutters and partition frames (aluminum/ woodedn) with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge. 30 Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.)With float glass panes of 5 mm thickness (weight not less than 12.5 kg / sqm) 31 Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all complete. With Galvanized M.S. Wire gauge with wire of dia 0.63 mm 9.9.1.2 With 12 mm mild steel U beading 32 Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300x16 mm 33 Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 300x10 mm 34 Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 200x10 mm 35 Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x10 mm 36 Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 150 mm 37 Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 100 mm 38 Providing & fixing 100 mm aluminium Hook with eye 100mm long 39 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete 40 52mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 liter per 50kg of cement or as per manufacturer’s specifications, including cost of cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 41 Providing and installation of Vertical blinds complete in all aspects.The vertical blinds shall suit all environments, Using a sleek, shallow wide body system, operation should be smooth and simple allowing the blinds to tilt, turn or stack to either side of the window for complete light control with Novara fabric having compostion of 3ply Vinyl / 1ply Fiberglass ( 72% Vinyl + 28 % Fiberglass)Fabric width (Vanes/Strip wdth 089MM) overall fabric thicness should be 0.33mm (+/- 5%) with light fastness should be of Grade >6 as per SGS certification to BS EN ISO 105-B07 standards. Dying Process of the fabric should be Yarn Dyed / Acrylic Coated wth Fire Retardant Standard BS5867-1980 Part 2 having Special Property of Easy wipe ( in case of stain) with wet cloth. Control Unit should be Injection moulded with high quality plastic used with Head Rail of Shallow wide body system in white aluminium head rail. Width: 44.5mm & Height: 25mm. Fabric Bonding should be Depending upon fabric composition, fabric should be bonded by Fusing or Sewing both top and bottom fold Brackets for Head Rail Steel Powder coated ceiling or wall brackets in White or Black finish.Operating Chain White plastic chain enhancing the look of blinds and ease of operation with chain connector and polycarbonate stopper of O/D:6mm & I/D:4mm. Average number of balls on chain are 50 per foot length. Bottom Weight with Link ChainTo keep straight finish moulded bottom weight for the fabric having Bottom link chain to keep all strips together.Cord Weight Colour co-ordinated plastic cord weight to stabalise the operating chain in White or Black based on accessories colour. Blinds should be installed by professional installers in accordance with the instructions of Engineer in charge with original and recommended support brackets & fasteners. Blinds should be installed leaving adequate clearance from obstructing objects like handles and using a spirit level to ensure smooth operation of blinds.Blinds should be measured from Left to Right across the EVO system or bracket to bracket if EVO systems are not used. The drop of the blind should be measured from bracket to the bottom of the bottom bar. D Decor, Johnson and Hunter Dogulas or eq make 42 Supply and fixing of 70 mm thick complete set of wrestling mat of 12 mtr x 12 mtr size made of EVA with non woven carpet on both sides and PVC coated Synthetic mat cover of700 gm weight, and design and colour as approved by WFI of make USI /KOXTANS/ ESS KAY and laid on water resistant plastic cover as per direction of Engineer Incharge. The mat shall procure after the approval of sample from Engineer incharge and Reputed Wrestling Court. 43 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 44 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 45 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. 46 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single Hole basin mixer of approved quality and make, including painting of fittingsand brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 47 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings 48 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour:Waste coupling 38mm of 83 mm length and 77 mm breadth weighing not less than 60gms 49 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Flexible pipe32 mm dia 50 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour: 600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms. 51 Providing and fixing 600x120x5mm glass shelf with edges round off supported on anodized aluminum angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs, etc. complete 52 Providing and Fixing in position storage type hot water electrical heaters with copper container, insulation, and stove-enamelled M.S jacket, thermostatically controlled immersion heater, with pilot lamp, 15/20mm dia inlet with non-return valve and 15/20mm dia outlet including making connections complete in all respect. (wall mounted with suitable M.S bolts and nuts) (Make -Venus/ havells/crompton) Capacity 25 litres 53 Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms 54 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms. 55 Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 56 Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms 57 Providing, Fixing,testing and commissioning of CP brass angle valve with 450 mm flexible coupling pipe for connection with sanitary fixture with CP wall flange, Nut and Washer etc. complete as required. 58 Providing and fixing un plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colour 59 Providing and fixing PTMT grating of approved quality and colour. Rectangular type with open able circular lid. 150 mm nominal size square 100 mm diameter of the inner hinged round grating. 60 Providing and fixingbeveled edge 8 mm mirror of superior glass (of approved quality) complete with Spacer & C.P. brass screws and washers complete. 61 Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre 62 Providing and fixing on wall face un-plasticized - PVC mouldedfittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion 110 mm Bend 87.5° 63 Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 75 mm diametre 64 Providing and fixing on wall face un-plasticized - PVC mouldedfittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion 75 mm Bend 87.5° 65 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.15mm nominal outer dia pipes. 66 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. External work including trenching, refilling etc. 15mm nominal outer dia pipes. 67 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. External work including trenching, refilling etc 25mm nominal outer dia pipes. 68 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc 25mm nominal outer dia pipes. 69 Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour 40 mm nominal bore, weighing not less than 62gms 70 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete25 mm nominal bore 71 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 72 Manufacturing supplying and fixing retro reflective overhead signage boards made up of 2mm thick aluminum sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type-III of ASTM-D-4956-01 as approved by Engineer-in-charge; letters, borders etc. as per IRC : 67-2001 in silver white with blue colour background and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class -II of ASTM-D-4956- 01 and fixing the same to the plate of structural frame work by means ofsuitable sized aluminum alloys, rivets 73 carriage of sand by mt 74 carriage of stone aggregate by mt 75 carriage of Brick by mt 76 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 77 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch Socket 78 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet 79 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. 80 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 81 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4.0 sq. mm + 1 X 4.0 sq. mm earth wire 82 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 83 Supplying and fixing 32 amp SPN rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 84 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way , Double door 85 Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured. 16 Sq. mm 86 Installation, testing and commissioning of 400 mm sweep Wall mounting fan (oscillating type) on wall with necessary fittings and connection from ceiling rose to fan using 2 coreflexible copper wire. 87 Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire. 380mm/15 Heavy duty 88 Supply, Installation, testing and commissioning of angle holder including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 89 Supply, Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. light Bulb9 watt 90 Supply, Installation, testing and commissioning of 20/22 watt 4-0 Tube light fixture aluminium housing with 2000 lumens and minimum efficasy of 100 lumens / wattpower factor More than 90 and 5000 burning hours 91 Installation testing and comissioning of2X2 Recessed luminaire with LED (Light Emitting Diode) maximum system power: 36 W, minimum Luminous flux of luminaire 100 Lm/w, Colour temperature of 5700K, Neutral white, CRI > 80, P.F >0.9 THD<15%,50,000 operating hours; Energy efficient LEDs, aluminium profile with Polyester powder white coloured coat Protruded Prismatic diffuser for glare-free uniform illumination, , IP 20. 92 Supply Installation, testing and commisioning of 1.5 tonn window type ACcopper 3 star cold type. each unit must provide colling and dishumidificationoperated by remote. Warrantee.:-a). Warrantee shall be provided for 12 month from the date of installations. b). The compressor shall be warranted for 5 years from the date of installation. 93 Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary.Warrantee.:-2 Years from the date of installation. 4 KVA 94 Supplying and fixing of following sizes exhaust fan with PVC blade & Louvers complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire. 200 mm 95 Add provision for Design and vetting of Structural Drawings from IIT/NIT/ design Directorate for truss work. 96 Provision for supply and Installation ofPedestal for Inaguration made of MS Frame 40 x 40 x 2.6 mm with 4 mm thick ACP Sheet as base of size 4 x 6 and Acrylic Inaguration Plate Acrylic sheet cover as per direction of Engineer Incharge

Key Value

Document Fees
INR 1100 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail