| 1 | Supply of following type of XLPE POWER CABLE of 1.1 kv grade armoured Al. cablecompulsory ISI mark confirming to IS:7098/ PART –I / 88 with amendment no.1 as required. |
| 2 | CABLE SIZE 2 X 6 SQ.MM |
| 3 | Laying of one no PVC insulated and PVC sheated power cable with the help of 7/18 GI stay wire & both side turn buckle with suitable size clamp fixing of pole/Godown wall/truss etc. as required for cable size of upto 35 sq mm |
| 4 | Upto 35 sq. mm |
| 5 | Laying and fixing of one No. PVC insulated & PVC sheathed/XLPE al conductor cable of 1.1KV gradeof following size on the wall surface as reqd. |
| 6 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 7 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required |
| 8 | 2X6 sq mm |
| 9 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 10 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 11 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 12 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required. |
| 13 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 14 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 15 | (a) Single pole and neutral |
| 16 | (b) Single Pole |
| 17 | Supplying and fixing following size/modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 18 | 12 Module (200mmX150mm) |
| 19 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (for computer boxes and power socket in switch boards) |
| 20 | 5/6 A switch |
| 21 | 3 pin 5/6 A socket outlet |
| 22 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 23 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizeof FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 24 | 2X1.5 sqmm + 1X1.5 sqmm earth wire |
| 25 | 2X2.5 sqmm + 1X2.5 sqmm earth wire |
| 26 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 27 | Supply of 20 W LEDlight Batten fitting including all accessories i.e., round block, screw etc as required.(As per NABL Certified ISO/IEC Specifications) Efficacy not less than 100 lm/W |
| 28 | Supply, Installation, Testing and commissioning of1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 29 | Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent/LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 30 | Supplying of 20 watt LED retrofit polycarbonate body with double side connection type tube suitable to mount on metallic box type batten fixture, efficacy 100 LPW with inbuilt driver (As per NABL certified ISO/1EC specification) |
| 31 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. |
| 32 | 3 x 1.5 sq. mm |
| 33 | Dismantling and Refixing of 20/25 mm steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 34 | Supply, installation, testing commissioning of35W Integrated LED Well glass luminaries comprises of die cast canopy and gear housing, IP66, efficacy 120 LWP, with M.S. CLAMPS andG.I. nut & bolts with washers as required.(As per NABL Certified ISO/IEC Specifications) |
| 35 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 36 | Supplying and fixing DP sheet steel enclosure on surface/ recessalong with 25/32 A 240 V \"C\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 37 | Supply Installation Testing and Commissioning of 400 mm sweep wall fan, PP blade, low noise operation thermal overload protection ,smooth oscilation, 1330 RPM suitable for 230/240volt, 50 cycles/sec., single phase supply conforming to ISI-374/1966 as amended from time to time etc. as reqd. |
| 38 | S/F of W.P. SMC PVC LILO box on pole of size:(270X225X135 mm) including fixing with M.S. clamp 40X3 mm thick on pole along with 3 no. MCB 10 amp and one nos. nutral link and 1.50 sq. mm pvc insulated copper conductor single core cable from box to individual fitting through or along pole. |
| 39 | Supplying, installation, testing and commissioning of 50 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 Protection complete with all accessories etc.(As per NABL Certified ISO/IEC Specifications) System efficacy>110 LPW. |
| 40 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/isolator) |
| 41 | 6 way, Double door |
| 42 | Supplying, installation, testing and commissioning of 120 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 Protection complete with all accessories etc.(As per NABL Certified ISO/IEC Specifications) System efficacy>110 LPW. |
| 43 | I/T/C of prewired street light fittings complete with all accessories on the existing G.I. pipe bracket on pole /wall including wiring & connections as required. |
| 44 | Supply of LED street light fitting of 20 watts, Pressure die cast Al. housing complete with all accessories and inbuilt surge protection.IP 66, Efficacy ≥ 110 LPW (As per NABL certified ISO/1EC specification) |
| 45 | Providing and fixing 2mtr long 50 mm X 50 mm X 6 mm angle ironon wall/poleincluding painting the angle and flat iron with primer and finish paint etc. for installation of street light fitting as required. |
| 46 | Supply Installation Testing and Commissioningof 380 mm sweep, 1400 rpm heavy duty Exhaust Fan , turbo force, IP 55, single phase ISI marked,complete in all respect. |