| Sl. No. | Item Description |
| 1 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5sqm each and making good to disturbed surfaces and removing from site of work complete all as specified and as directed by the Engineer-in-Charge. |
| 2 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5sqm but not exceeding 4.00Sqm each and making good to disturbed surfaces and removing from site of work complete all as specified and as directed by the Engineer-in-Charge. |
| 3 | S & F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ S & F Ceosetory windows and other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/ borer proof,water/ moisture proof and fire retardant and fixed in position with and including MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. |
| 4 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plainflushdoor shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisturproof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with and including stainless steel concealed hinges of required size with necessary S.S screws, all as per direction of Engineer- In- Charge. |
| 5 | S & F for aluminum powder coated (powder coated of required colour) three track (2 Nos Glazed shutter & 1 Nos Gauzed shutter) sliding windows frame top & sides of size 92 x 31.75 x 1.50mm (section No 20831) bottom of size 92 x 31.75 x 1.50mm (Section of 20832) and shutter top & bottom of size 40 x 18 x 1.55 (section 20738) and lock side shutter frame of size 40 x 15 x 1.45mm (Section 20737) with rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including stainless steel wire mesh 0.36mm nominal dia with 1.40mm average aperture and fixed with stainless steel wire staples and fixing 5mm thick glass with necessary rubber beading gasket etc complete all as specified and directed. |
| 6 | S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws,Aluminium Louvers all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 7 | S & F for powder coatedaluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified . |
| 8 | S&F 100 mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised type B-21 complete all as specified & as directed. |
| 9 | S&F 150 mm size aluminium handles, cast type, anodized and fixed complete all as specified & as directed. |
| 10 | S&F 200 mm size aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified & as directed. |
| 11 | S&F 150 mm size aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified & as directed. |
| 12 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones. |
| 13 | S&F 3mm thick sheet glass , ordinary qualityand glazing with oil putty in squares area not exceeding 0.5 Sqm in each pane, complete all as specified and directed. |
| 14 | S&F 3mm thick frosted, on one side sheet glassand glazing with oil putty in squares area not exceeding 0.5 Sqm in each pane, complete all as specified and directed. |
| 15 | S&F 250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudedsections or cast-aluminium alloy and fixed complete all as directed. |
| 16 | S&F in repair MS Chroumium plated curtain rod 25 mm diawith and incl MS Chromium plated decorative round funnals on either end and provide a visually balanced appearance incl MS Chromium plated brackets fixed to wall with 30mm wooden steel screws and PVC rawal plug anchors and installation complete all as specified and directed. |
| 17 | S&F in repair stainless steel wire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed withfixed withsteel wire staples complete all as specified & directed. |
| 18 | Taking down cement plaster on brick or concrete wall and ceiling including raking out joint, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 19 | M&L rendering 10mm thick on fair faces of brick work or concrete surfaces of walls in CM (1:6) and finished even and smooth without using extra cement complete all as specified. |
| 20 | M&L rendering 15mm thick on fair faces of brick work or concrete surfaces of walls in CM (1:4) and finished even and smooth without using extra cement complete all as specified with using WPC as per manufacturer instruction complete all as specified and directed. |
| 21 | M&L for rendering 5 mm thick on fair faces of brick work or concrete surfaces in CM (1:3) as in ceiling finished even and smooth without using extra cement complete all as specified and directed. |
| 22 | M&L for preparation of new plastered surfaces of wall andapplying three coats of white washcomplete all as specified directed. |
| 23 | M&L for preparation of new plastered surfaces of ceiling andapplying three coat of white wash complete all as specified and directed. |
| 24 | M&L for preparation of oldplastered or unplasteredsurfaces of wall andapplying two coats of white washcomplete all as specified directed. |
| 25 | M&L for preparation of old plastered or unplastered surfaces of ceiling andapplying two coat of white wash complete all as specified and directed. |
| 26 | M & L for applying two coats of oil bound distemper using Airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface scomplete all as specified and directed.Note : (a) Sanding of surface to be done by mechanical sander with 1500-2700 rpm, with internal dust extraction system for clean environment certified by paint manufacturer. Proper mashking to carried before primer and paint application.(b) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the materials i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by GE. |
| 27 | M& L for preparation of wood and wood based old painted surface of any description , not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. |
| 28 | M& L for preparation of steel and iron old painted surface of any description , not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. |
| 29 | M & L for Complete removal of existing treatment on wall/ roof projections incl facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust loose paint etc by skilled labour complete all as specified and as directed |
| 30 | M & L for waterproof cement based putty @ 1 Kg (undiluted) per sq mtr of average thickness 1mm over the plastered / old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanicsm) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust etc by skilled labour as per following steps : -Step 1 : Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5Kg putty per minute.Step 2 : Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a max pressure 3300 PSIStep 3 : Allow 6-8 hrs time to dry the putty surfaceNote : (a) The work pertaining to periodical services and water proofing primer shall be executed from authorized applicator through manufacturer of which the materials i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by GE.(b) Cost of Scafolding upto 10 mtr height of building is included in this item.(c) The contractor shall upload along with the documents under cover I , Memorandum of understanding (MoU) with only one manufacturer mentioned in the contract, failing which the bid shall be liable to be rejected.(d) Masking of waindow/doors during spray painting using polythine film will be included (e) Cleaning and clearing site of paint, mats etc included.(f) 05 years guarantee of painting work will be admissible after date of completion and 15% amount will be reserve against painting work after date of completion for the 05 years and same will be realised to contractor after satisfactory completion of 05 years. |
| 31 | M & L for one coat of acrylic water based exterior grade primer @ 0.9 ltr (undiluted/10 sqmtrs diluted with water 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface for painting of subsequent coats complete all as specified and directed.Note :(a) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the materials i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by GE.(b) Cost of Scafolding upto 10 mtr height of building is included in this item. |
| 32 | M & L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive and color stay Techonology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/litre as per the LEEDS specifieecations, Anti Algal properties in two coats @ 1.79 ltr (Undiluted)/10 Sqm with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow spreed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface in both coatsof paint complete all as specified and directed.Note :(a) The work pertaining to periodical services and water proofing shall be executed from authorized applicator through manufacturer of which the materials i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by GE.(b) Cost of Scafolding upto 10 mtr height of building is included in this item. |
| 33 | M&L for preparation of new plastered surfaces of walls andapplying two coats of cement base paint complete all as specified and directed. |
| 34 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises as directed. |
| 35 | Demolition of lime concrete/ lean concrete/ brick bats from sunken portion exc. 15 cm thickness (above ground level), including removal of rubbish outside MoD land, complete all as specified. |
| 36 | Roughening surfaces of sunken floor by sweeping clean and washing down with water to remove dust etc incl brushing neat cement slurry with 3.0 Kg of cement per sq metre and renderning 5mm thick in cement mortar 1:3 mised with water proofing compound as per manufacturers instruction and Applying evenly a coat of blown type bitumen at the rate of 1.5 Kg per sqm and blinding with clean dry sand @ 0.05cum per sqm and laying of black polythene film 150 micron thick laid over a coat of bitumen primer @ 0.30 to 0.5 Kg per Sqm in sunken surface complete all as specified and as directed. (Note : WPC Shall be measured and paid seperately) |
| 37 | M & L for PCC (1:2:4), type B-1, using 20 mm graded mechanically crushed stone aggregates,as in padding concrete to sunken floor, covering to junction of floor and vertical walls includingchamfering on edges complete all as specified and directed. |
| 38 | S & F of Steel water tubes, 40 mm bore, light grade, galvanized, as in spoutfor sunken floor, fixed in wall, inside end fixed with wire netting and external beveled edge at 45 degree, complete all as specified and directed. |
| 39 | M & L for Lean concrete (1:5:10), type E-2, using40 mm brick coarse aggregate, as in fundation and sunken portion complete all as specified and directed. |
| 40 | M&L for 25mm thick cement concrete type B-0, 1:2:4 (using 12.50mm graded stone aggregates), in sub base of floors, finished even & fair to receive bedding layer of cement mortar completeall as specified and directed. |
| 41 | M&Lglazed ceramic coloured tiles in vertical surface 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:4) as in screed bed of wall tiles complete all as specified and directed. |
| 42 | M&L non-skid colour joint free ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc over and over and including screed bed or bedding layer of mortar 20 mm thick in CM 1:6 for laying floor finishes set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 43 | Taking up or down steel water tubing and connections, including cleaning for refixing or removal to store bore of pipes 15mm dia. |
| 44 | Taking up or down steel water tubing and connections, including cleaning for refixing or removal to store bore of pipes 20mm dia. |
| 45 | Taking up or down steel water tubing and connections, including cleaning for refixing or removal to store bore of pipes 25mm dia. |
| 46 | M&L for cutting chases for inserting GI tubing in walls, floor etc and making good complete all as specified & directed. |
| 47 | S&F 15mm dia bore of pipes medium grade galvanised with all fitting and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 48 | S&F 20mm dia bore of pipes medium grade galvanised with all fitting and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 49 | S&F 25mm dia bore of pipes medium grade galvanised with all fitting and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 50 | S&F in repairs 15mm bore dia stop cock/angle cock, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed. |
| 51 | S&F 15mm dia fancy type chromium plated Bib taps cast copper alloy with crutch or butterfly handle screwed down fixed to iron pipe in repairs complete all as specified and directed. |
| 52 | S&F in repairs shower rose, chromium plated brass, fancy type, 125 mm with or without swivel joint, any size, including fixing to steel pipe or union, complete all as directed. |
| 53 | S&F in repairs vitreous china squating pan, \"Orissa\"pattern, size 580x440mm white, with integral foot rests, including 100mm cast iron \"P\" or \"S\" trap and 100mm cast iron sanitary connection socket to fit WC outlet including connection to trap, to flushing pipe, anti-syphonage pipe etc. complete including making good to floor complete all as specified and directed. |
| 54 | S & F in repairs Vitreous China wash down water closet pan including P or S trap, bolts, connection to plushing pipe anti-syphonage pipe etc complete all as specified and directed . |
| 55 | S & F in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. |
| 56 | S & F in repairs Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 57 | S&F inrepairs10 Litres capacity, PVC valveless, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets and connection to pipes and fixing of level. |
| 58 | S&F PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed. |
| 59 | Supply only flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed. |
| 60 | S&F for 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers fixed in repair complete all as specified and directed. |
| 61 | S& F corner shelf of PTMT fixed with and including Chromium plated brass screws and wooden / plastic cleats (Minimum weight 300gms) complete all as specified and directed. |
| 62 | S&F Brass CP tubular towel rail 20mm dia , 600mm longincluding brackets complete all as specified and directed. |
| 63 | S&F in repairs white Vitreous China Urinal, full stall type, (excluding flushing cistern,) with 32 mm size brass chromium plated waste coupling & discharge pipe, providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, including cast copper alloy chromium plated urinal spreader complete all as specified and directed. |
| 64 | S&Fvitreous china urinal partition white of size 310x700mmcomplete all as specified and directed. |
| 65 | S&F 1500 Ltrs capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. |
| 66 | S&F 25mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed. |
| 67 | S&F 20mm dia nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm- 45gms /25mm- 65gms) complete all as specified and directed. |
| 68 | S&F 20mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 69 | S&F 25mm dia gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 70 | Demolition of reinforced cement contrete of any description in any position not otherwise specifically provided for complete all as specified & directed. |
| 71 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified |
| 72 | S&F PVC (SWR) bends 110mm dia any radius provided with access doorcomplete all as specified and directed. |
| 73 | S&F PVC (SWR) bends 110mm dia any radiuswith out access doorcomplete all as specified and directed. |
| 74 | S&F PVC (SWR) bends 75mm dia any radius provided with access door all complete all as specified and directed. |
| 75 | S&F PVC (SWR) junction single, (single T)110mm dia any radius provided with access doorcomplete all as specified and directed. |
| 76 | S&F PVC (SWR) junction single (single T) 75mm dia any radius provided with access door complete all as specified and directed. |
| 77 | S&F 110mm dia PVC (SWR) vent cowl complete all as specified and directed. |
| 78 | S&F 110mm PVC (SWR) WC connector bent typecomplete all as specified and directed. |
| 79 | S&F 110mm diaPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 80 | S&F in repairs 75mm diaPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 81 | S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cementcomplete all as specified and directed. |
| 82 | M&L110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 83 | M&L 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 84 | M&L for PCC 1:3:6 type C1 as in concrete bed to drain pipes including packing under and completelysurrounding pipes with concrete after they are laid and tested 110mm dia pipe complete all as specified and directed. |
| 85 | S&F 150x150mm Salt-glazed stoneware gully traps, square or round mouthed, type `P\" complete all as specified and directed. |
| 86 | Taking down existing treatment of any description and any layer from roof including scraping and roughening old by picking, sweeping clan and washing down complete all as specified and as directed |
| 87 | M&L forCutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight |
| 88 | M&L 10mm thick rendering in CM 1:3 with water proofingcompound @ 3% by weight of cement or as per manufacturer instruction over RCC roof slabfinished even and smooth with out using extra cement complete all as specified and directed. |
| 89 | Supply only liquid water proofing compound complete all as specified and directed. |
| 90 | M & L for applying APP modified bituminous water proofing membrane with polyester reinforcement and plain finish of 3 mm thick (not less than 3.8 kg/ sqm ± 5 % per sqm) consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25° C, 0.87-0.89 kg/ litre and viscosity 70-160 cps over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc. and including applying bituminous aluminium paint @ 0.125 Kg / sqm on finished APP surface complete all as specified and as directed. |
| 91 | M&L for 50 mm thick Cement concrete type C-1, 1:3:6 (using 20 mm graded stone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with hot bitumastic mix in proportion of bitumen and sand 1:2 complete as specified & directed. |
| 92 | M&L PCC 1:2:4 type B1 (using 20mm graded aggregate) as in concrete fillets at junction of roof and parapet wall,copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 93 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles complete all as specified & directed. |
| 94 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and directed. |
| 95 | M&L PCC 1:3:6type C2 (using 40mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 96 | M&L brick work with sub class \"B\" bricks, straight or curved on plan exceeding 6m radius built in cement mortar 1:4 complete all as specified and directed. |
| 97 | M&L 15mm thick rendering in CM 1:3 with water proofingcompound @ 3% by weight of cement or as per manufacturer instruction on walls and applying a setting coat 3mm thick, trowelled to even and smooth finish complete all as specified and directed. |
| 98 | M&L for PCC 1:2:4 type B1 (using 20mm graded aggregate as surface channel and drain complete all as specified and directed. |
| 99 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed. |
| 100 | M&L Providing precast cement concrete 1:2:4 Type B1 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete all as specified and directed. |
| 101 | TMTbars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clipscomplete all as specified and directed. |
| 102 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0kg of cement per sqm metre complete all as specified and directed. |
| 103 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick (squire / rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in cement mortar 1:6 for laying floor finishes complete all as specified & directed. |
| 104 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick as in skirting and dado, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over andincluding 10mm thick renderingin cement mortar 1:4 for vertical surfaces such as skirting etc complete all as specified & directed. |
| 105 | M & L for Machine cut Pre polished Kota stone slab flooring 18-20mm thick over and including 15mm thick cement screed of cement mortar 1:3 base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete.(Note : Kota stone to be fixed in staircase thread shall be of single piece) |
| 106 | M &L Machine cut Pre polished Kota stone slab flooring 18-20mm thick over and including 10mm thick cement screed of cement mortar 1:3 base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing as in risers of steps, skirting, dado etc complete all as specified and directed.(Note : Kota stone to be fixed instair case thread shall be of single piece with both side 100 mm wide marble border any colour has directed by Engr in-Charge) |
| 107 | Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as directed. |
| 108 | M&L for Point wiring complete as specified with 1100 volt grade 1.5 sq.mm. (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through and including concealed type rigid non -mettalic PVC conduitof suitable size but not less than 20mm, with all fittings, fixed on wall/ceiling /floor including modular box suitable for housing modular pattern switches/ sockets/ regulators etc.and duly earthed with same cable as for wiring above but green in colour as continuous earthing wire complete all as specified & directed for :-(a) One light /Fan /Ex Fan point controlled by one, one way switch(b) One socket outlet 3 or 5 Pin, 6 Amp on independent boardNote :- (i) Modular Plates & Covers and Modular Metal Boxes/PVC Boxes will measured and paid separately under relavant items.(ii) Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate.(iii) The wiring shall be done strietly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. |
| 109 | All as per Ser item No 82.00 above but with 1.5 sqmm copper cable in and including concealed type rigid non -mettalic PVC conduitcomplete all as specified and as directed for One socket outlet 3 or 5 Pin, 6 Amp on same board. |
| 110 | All as per Ser item No 82.00 above but with 2.5 sqmm copper cable in and including concealed type rigid non mettalic PVCconduit complete all as specified and as directed for socket outlet 3 or 6 pin 15 Amps. |
| 111 | S&F modular switch 6 Amp one way 1 module 230 V AC complete all as specified and directed. |
| 112 | S&F modular switch 16 Amp one way 1 module230 V AC complete all as specified and directed. |
| 113 | S&F modular socket outlet 6Amp 2 module intel multi socket for all pins 230 V AC complete all as specified and directed. |
| 114 | S&F modular socket outlet 16 Amp 2 module and 6/16 Amp heavy duty 230 V AC complete all as specified and directed. |
| 115 | S&F 3 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge. |
| 116 | S&F 4 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge. |
| 117 | S&F 8 module Metal Flush Box including white cover plate with frame for fixing of modular switeches/sockets etc. complete all as specified and directed by Engineer-in-charge. |
| 118 | S&F ceiling rose, three terminal, PVC/polycarbonate, isolated body, ISI markedcomplete all as specified and as directed. |
| 119 | S&F LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC decorative box type with driver, holder including fitting fixed on wall/ceiling and connecting up complete with 3 core flexible cable white of suitable size and making necessary connection complete all as specified and directed. |
| 120 | Fixing only serviceable LED Tube lights fitting 1 x 18/20 Watt, 4 feet ,220V AC obtained from taking down. |
| 121 | S&F LED Tube lights fitting 1 x 9/10 Watt, 2 feet , 220V AC decorative box type with driver, holder including fitting fixed on wall/ceiling and connecting up complete with 3core flexible cable white of suitable size including taking down old unsv tube light fitting and making necessary connection complete all as specified and directed. |
| 122 | Fixing only serviceable LED Tube lights fitting 1 x 9/10 Watt, 4 feet ,220V AC obtained from taking down. |
| 123 | S&F LED building security light fitting 1 x 35 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protectionincl mounting bracket of suitable size and connection complete all as specified and directed. |
| 124 | Taking down carefully old unserviceable ceiling fans / Exhaust fans complete, removing its blade and deposit to the MES Store yard by the contractor. |
| 125 | S&F Exhaust fans made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm and connecting up including louvers including making necessary opening on stone /brick masonry wall of suitable size, finishing it properly and making good with matching colour with the surroundings provision of cable 3 core ofof suitable size from ceiling rose to fan complete all as specified and as directed. |
| 126 | S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one number single pole MCB 20 Amps , 240 Voltscomplete all as specified and as directed. |
| 127 | M&L for providing concealed sub main wiring with two single core 6.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through PVC Conduit as per direction complete including 6.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wire including taking down/removing old one & cutting chases in walls by cutterand making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note :- (i) Three runs of single core 6.00 Sqmm multi stranded copper cable and one run of PVC conduit shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the conduit. |
| 128 | M&L for providing concealed sub main wiring with two single core 4.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through PVC Conduit as per direction complete including 4.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wire including taking down/removing old one & cutting chases in walls by cutterand making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note :- (i) Three runs of single core 4.00 Sqmm multi stranded copper cable and one run of PVC conduit shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the conduit. |
| 129 | S&F single pole and neutral DB wall mounting type, 240 Volts,8 Way with 200 Amps rated bus bar, double door suitable for fixing MCB\"s including connecting etc and taking down U/S DB ,main switch complete. |
| 130 | S&F MCB single pole and neutral (SP&N) 40 Amp 240 volts 10 KA \"C\" series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable, complete all as specified and directed. |
| 131 | S&F MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA \"C\" series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable complete all as specified and directed. |