}

Tender For Repair / Maintenance Of External Electrification And Allied Works At Icgs Malkapuram, Icgs Jetty Visakhapatnam Under Ge(I) Cg Visakhapatnam., visakhapatnam-Andhra Pradesh

Military Engineer Services has published Tender For Repair / Maintenance Of External Electrification And Allied Works At Icgs Malkapuram, Icgs Jetty Visakhapatnam Under Ge(I) Cg Visakhapatnam.. Submission Date for this Tender is 12-07-2025. Building Work Tenders in visakhapatnam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

49807148
Tender For Repair / Maintenance Of External Electrification And Allied Works At Icgs Malkapuram, Icgs Jetty Visakhapatnam Under Ge(I) Cg Visakhapatnam.
Tender
Indian
Andhra Pradesh
Visakhapatnam
12-07-2025

Tender Documents

Tender Details

Tender For Repair / Maintenance Of External Electrification And Allied Works At Icgs Malkapuram, Icgs Jetty Visakhapatnam Under Ge(I) Cg Visakhapatnam.; 1 Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, in cable tench etc. n exc 10 sqm on plan and getting out soft / loose soil complete all as directed. 2 Returning, filling in incl spreading, leveling, watering and well ramming in layers n exc 25 cm complete all as specified & directed. 3 Removing excavated material to a distance n exc 50 mtr and depositing where directed at a level n exc 1.50 mtr above the starting point complete all as specified & directed. 4 M & L for sand cushioning under trenches as in cable protection complete all as specified and directe.(Note: Punned thickness shall measured for payment purpose) 5 Supplying and laying reinforced precastconcrete cable cover, class HV, Type 1,flat,size300mmx l80mm x 40mm complete all as specified & directed. 6 Supplying and laying reinforced precastconcrete cable cover, Class LV, Type I,flat,size 250mm x 150mm x 40mm complete all as specified & directed. 7 S&F steel tubular swaged poles completewith cast iron base plate, finial taperplug, bolts, nuts & screws asspecified type 410 SP-31 (overall 9.00metres long) conforming to IS IS 2713 (Parts 1 to 3) 1980 duly painted with two coats of aluminium paint externally above planting depth and two coats of bituminous paint internally and externally upto planting depthincluding taking down old unserviceable pole complete all as specified and directed.(Note: Necessary earthwork, PCC work etc necessary for fixing of pole shall be measured and paid separately in relevant item.) 8 M&L for PCC 1:3:6 type C2 (Using 40 mm graded stone aggregate) as in foundation of pole or mass concrete complete all as specified and directed. 9 M&L for PCC 1:2:4 type B2 (Using 40 mm graded stone aggregate) as in foundation of pole or mass concrete complete all as specified and directed. 10 M&L for PCC 1:2:4 type B1 (Using 20 mm graded stone aggregate) as in coping of polecomplete all as specified and directed. 11 Supply, laying and testing of XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.00 sq mm 4 core shall be laid under trench or pipe or loop or shall be fixed on wall / pole including taking out old unserviceable cable complete all as specified and directed.(Note: Earthwork , excavation, sand coushioning, GI pipe etc. shall be measured and paid separately uinder relevant item) 12 All as per item No. 11 here-in-before but 16 Sqmm , 4 core. 13 All as per item No. 11 here-in-before but 35 Sqmm , 3.5 core. 14 All as per item No. 11 here-in-before but 50 Sqmm , 3.5 core. 15 All as per item No. 11 here-in-before but 95 Sqmm , 3.5 core. 16 All as per item No. 11 here-in-before but 120 Sqmm , 3.5 core. 17 All as per item No. 11 here-in-before but 150 Sqmm , 3.5 core. 18 All as per item No. 11 here-in-before but 185 Sqmm , 3.5 core. 19 Supply, laying and testing of XLPE insulated, screened, PVC bedded,galvanisedsteel striporwire armoured,electric power cables (heavyduty) withaluminium conductor, 11000 volts Earthed,grade cross sectional area 95 sq. mm, 3 core shall be laid under trench or pipe or loop or shall be fixed on wall / pole including taking out old unserviceable cable complete all as specified and directed. (Note: Earthwork , excavation, sand coushioning, GI pipe etc. shall be measured and paid separately uinder relevant item) 20 All as per item No. 19 here-in-before but 120 Sqmm , 3 core. 21 M&L for detection of fault through fault locating high voltage mobile machine to locate the fault in 11 KV HT cable by giving high voltage saurge and to find out exact location of fault complete all as specified and directed. 22 S&F in repair lightning arrestersexpulsion type 11 KV with all fittings, transmission class, discharge capacity 65 Kilo Amp including necessary fixing arrangementscomplete all as specified and directed. 23 S&F in repair switch air break, gang operated, triple pole, mechanically operated, mountedoninsulatorandsteelframe, with operating mechanismworked from ground level, forcurrent rating upto 200 amps, 11000 Volts all as per Clause No. 19.69 of SSR Part-I (2009) with fixed contacts of phosphorus bronze and a set of drop out HT fuse assembly, fuse carrier fittings, insulator type mounted on MS channel operating rod with pad lock arrangement including dropout fuse assembly complete all as specified and directed. 24 S&F in repair 11 KV DO fuse unit, channel type with all types of fixing arrangement complete all as specified and directed. 25 S & F in repairsdisc type insulator, porcelain, vitreous, 100mm high and 65mm dia balland socket type, 11000 volts grade, white, brown or green, single disc assembly including galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut complete all as specified and directed. 26 Filtration and dehydration of transformer oil at substation to achive di-electric strength not less than 60 KV at 4 mm gap as per relevant IS with portable filtration plant, testing of the oil for the di-electric strength before and after filtration complete all as specified.. 27 Supply only transformer oil conforming to IS 395-1983 having di-electric strength minimum 60 KV / 4mm gap complete all as specified and directed. 28 Disconnecting LT/HT connection and earthing strip connection of the transformer 100KVA to 400 KVA capacity and transportation up to workshop for repair and disconnecting , dismantling & complete overhauling of 11 KV distribution Transformer any capacity afterdrain out of transformer oil and kept in close containers for re use, lifting/removing of top cover of transformer & cores with chain pully blocks/crane, cleaning of sludge and washed down with the help of spray of clean oil and re-assembling of transformer with S&F of new gasket set assembly, repairs of nuts, bolts and washers, as required at site, re filling of Transformer oil after centrifuging at satifactory dielectric strength complete after electric connections and testing all as specified and directed by Engr-in-Charge.Note :- (i) If retrieved transformer oils di-electric strength is very less than it will be replaced with new one in relevent items.(ii) If any minor items is required for smooth functioning of transformer including general cleaning of surrounding area and equipment also, the cost of the same will be deemed to be included in the unit rates.(iii) Cost of transportation up to workshop & back and insttalation after repair including electric/earth connection is deemed to be included under quoted rate by the contractor. 29 M&L for rewinding of distribution transformers of any capacity / size / type by strip opening & rewinding the HV coils (i.e. primary coils) from core assembly safely, removing old defective insulation paper, re-winding the coils with new copper wire as per I.S. of same gauge and existing size together with new insulated materials / bracings before placing in to the transformer and assembling the coil with new insulation and fitting the coils in the chamber, testing and commissioning the transformer and recording the test results complete all as directed. 30 All as per Sl item No. 29.00 here-in-before butfor LV Coils. 31 S & F in repair HT bushing out door/In door type 11/12 KVHV brass metal part as per IS 3347/1967 complete with porcelain bushing, brass stem, nut, bolt, washers, brass studs and gasket etc complete.all as specified and as directed. 32 S & F in repair LT bushing out door/In door type 1.1 KV LV 200/250 KVA transformerbrass metal part as per IS 3347/1967 complete with bushing brass stem nut, bolt, washers, brass studs and gasket etc complete.all as specified and as directed. 33 S & F in repair LT bushing out door/In door type 1.1 KV L.V 315/400 KVA transformer brass matel part as per IS 3347/1967 complete with bushing brass stem nut, bolt, washers, brass studs and gasket etc complete.all as specified and as directed. 34 S & F in repair LT bushing out door/ In door type 1.1 KV L.V 500/ 630KVA transformer brass matel part as per IS 3347/1967 complete with bushing brass stem nut, bolt, washers, brass studs and gasket etc complete.all as specified and as directed. 35 S & F in repairOil level indicator of suitable capacity complete.all as specified and as directed. 36 S & F in repair temprature Gauge of suitable sizes complete.all as specified and as directed. 37 S & F in repair Silica gel of good quality complete all as specified and directed. 38 S & F in repair Drain out Brass stop valve 25 mm dia heavy duty all as per sample complete all as specified and directed. 39 M & L for painting of 11 KV distribution transformer of capacity 100 KVA to 400 KVAwith synthetic enemel paint two coats by spray painting approved colour after scraping of old paint, cleaning of all rusted portion, surface including sign writing i.eMES No,Make , Capacity etc. complete all as specified anddirected. 40 M & L for painting of 11 KV distribution transformer of capacity up to 630 KVAwith synthetic enemel paint two coats by spray painting approved colour after scraping of old paint, cleaning of all rusted portion, surface including sign writing i.e MES No, Make, Capacity etc. complete all as specified and directed . 41 M & L for maintenance and overhauling of ACB up to 1600 Amps capacity including de-assembly all operating mechanism parts, well cleaning with petrol CRC 226, replacing unserviceable parts and accessories, oiling/ greasing of moving parts, cleaning of all pole partition hylem sheet, isolating contacts, re-assembly, fine setting of mechanism and pole assembly and making ACB perfect operational including well cleaning the complete panel bus bars chamber, insulator, partition etc. and checking of insulation resistance of ACB and main bus bar, SR18G relay testing & calibration complete all as specified and as directed by the Engineer-in-Charge.Note:- Spare parts for ACB to be measured and paid separately in supply only items. 42 Supply only male contacts of existing size & Capacity for LT ACB complete all as specified and directed . 43 Supply only female contacts of existing size & Capacity for LT ACB complete all as specified and directed . 44 Supply only locakable Trip Push Button (LTPB) for LT ACB complete all as specified and directed . 45 Supply only lock in Isolation Position (LIP) assembly for LT ACB complete all as specified and directed . 46 Supply only lock in any position (LAP) assembly) for LT ACB complete all as specified and directed . 47 Supply only door interlock assembly for LT ACB complete all as specified and directed . 48 Supply only shunt Release (SR) of existing capacity for LT ACB complete all as specified and directed . 49 Supply only under Voltage release (UVR) for LT ACB complete all as specified and directed . 50 Supply only earth Fault Release (for DN1) for LT ACB complete all as specified and directed . 51 Supply only vertical terminal adaptor for LT ACB complete all as specified and directed . 52 Supply only ACB Relay SR18G complete all as specified and directed . 53 Supply only cradle terminals for LT ACB complete all as specified and directed . 54 Supply only ACB Supportscomplete all as specified and directed . 55 Supply only ACB to Busbar lincks complete all as specified and directed . 56 Supply only ACB safety shutters complete all as specified and directed . 57 Supply only ACB Jaw contacts complete all as specified and directed . 58 Repair/Maintenance of LT Panel board by taking shut down, removing of carbon particles, rubbing of heated portion of bus bar and cleaning complete by means of CRC-226/Petrol tightening of all joints in bus bar, checking of earthand neutral voltage and make a record, repairs of u/s nuts/ bolts/ washers including repairs of corroded glands, lugs/ thimbles and tightening them properly including Painting of external surface after rubbing scrapping waste diposited material, appliying primer , with two coat of enamel paint of approved shade complete all as specified and directed.(Note: Spares required will be measured and paid separately) 59 S&F in repairs MCCB 400 Amp capacity, 4 Pole, 415Volt grade, rupturing capacity 36kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified and directed.Make : Legrand / L&T / Siemens / ABB 60 S&F in repairs MCCB 250 Amp capacity, 4 Pole, 415Volt grade, rupturing capacity 36kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified and directed. Make : Legrand / L&T / Siemens / ABB 61 S&F in repairs contractor, 325 Amps, 2NO + 2NC,MCX41, 4 Pole, 415 Volt grade, including making incoming and outgoing connections using thimbles / lugs / cables of appropriate size, complete all as specified and directed. Make : Legrand / L&T / Siemens / ABB 62 S&F in repairs contractor 160 Amps, 2NO + 2NC,MCX32, 4 Pole, 415 Volt grade, including making incoming and outgoing connections using thimbles / lugs / cables of appropriate size, complete all as specified and directed. Make : Legrand / L&T / Siemens / ABB 63 S&F in repairs MCCB 160 Amp capacity, 4 Pole, 415Volt grade, rupturing capacity 25kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified and directed. Make : Legrand / L&T / Siemens / ABB 64 S&F in repairs MCCB 100 Amp capacity, 4 Pole, 415 Volt grade, rupturing capacity 16kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections using thimbles / lugs of appropriate size, complete all as specified and directed. Make : Legrand / L&T / Siemens / ABB 65 S&F in repairs MCCB 63 Amp capacity, 4 Pole, 415Volt grade, rupturing capacity 16kA, with fixed thermal and magnetic setting, including making incoming and outgoing connections usingthimbles / lugs of appropriate size, complete all as specified and directed. Make : Legrand / L&T / Siemens / ABB 66 S&F in repair digital type voltmeter of size 96 x 96 mm complete all as specified and directed. 67 S&F in repair digital type Ammeter of size 96 x 96 mm complete all as specified and directed. 68 S&F in repair panel Multi Funtion Meter with Suitable CTs complete all as specified and directed. 69 S & F in repair Termination Heat Shrinkable type Cable Jointing Kit 11 KV (Earthed) grade cable for straight through joint Kit Outdoor/ Indoor type with Jointing Materials and accessories suitable for alumenium conductor cable of size 3 Core 185 - 240 sqmm fixed in repair, including testing after jointing complete all as specified and directed.Make : Birla 3M/ MSeal/Denson/Raychem 70 S & F in repair Termination Heat Shrinkable type Cable Jointing Kit 11 KV (Earthed) grade cable for straight through joint Kit Outdoor/ Indoor type with Jointing Materials and accessories suitable for alumenium conductor cable of size 3 Core 95- 120 sqmm fixed in repair, including testing after jointing complete all as specified and directed.Make : Birla 3M/ MSeal/Denson/Raychem 71 S & F in repair Termination Heat Shrinkable type Cable Jointing Kit 11 KV (Earthed) grade cable for end termination Outdoor/ Indoor type with Jointing Materials and accessories suitable for alumenium conductor cable of size 3 Core 95 -120 sqmm fixed in repair, including testing after jointing complete all as specified and directed.Make : Birla 3M/ MSeal/Denson/Raychem 72 S & F in repairTermination Heat Shrinkable type Cable Jointing Kit 11 KV (Earthed) grade cable for end termination outdoor/ Indoor type with Jointing Materials and accessories suitable for alumenium conductor cable of size 3 Core 185-240 sqmm fixed in repair, including testing after jointing complete all as specified and directed. Make : Birla 3M/ MSeal/Denson/Raychem 73 M&L for earthing complete with galvanized steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised earth strip of 25 x 4 mm size upto 7.50 m bymeans of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No-3 SSR Part -1 2009 connected to earthing test point including earth wire protection pipe of dia 40 mm (light grage), excavation and earth work, disposal of surplus spoil, provn of RCC cover 50 mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab and PCC (1:3:6) type C-1 concrete pit, funnel with watering pipe 20 mm bore (medium grade) testing on completion complete all as specified and directed. [Note : (a)Proper earthing pit should be provided with pit cover. (b) Excavation/earthwork is deemed to be included in the quoted rate.] 74 Suppling and laying Synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 Kv for electrical purpose as per IS 15652-2006, (Superseding IS 5424) suitable for electrical shock safety of sizes 2 m x 1m including taking down old unserviceable one complete all as specified and directed. 75 S&F phase indicator lamps (Red, Yellow and blue) suitable for fitting in existing panel including taking down old unserviceable lamp complete all as specified and directed. 76 S&F Start(Green)/ Stop(Red) push button for fitting in existing panel including taking down old unserviceable one complete all as specified and directed. 77 S&F in repairSelector Switch for fitting in existing panelcomplete all as specified and directed. 78 S&F i-Protector Auto Switch With Dry Run for 3 Phase Motors (i-ADSM) for fitting in existing panel including taking down old unserviceable complete all as specified and directed. 79 S&F Panel Lock Socket including each Key for 03 locks for fitting in existing panel including taking down old unserviceable complete all as specified and directed. 80 S&F in repairs Digital programable timer Switch suitable for On off Street light mounted of Din rail including making incoming and outgoing connections using thimbles / lugs / cables of appropriate size, complete all as specified and directed. Make : Cat No. - 67DDTO of GIC or equivelant 81 S&F in repairs Power contractor, 50 Amps, MNX-50/ MO-50, 3 Pole, 415 Volt grade, including making incoming and outgoing connections using thimbles / lugs / cables of appropriate size, complete all as specified and directed.Make : Legrand / L&T / Siemens / ABB 82 S&F in repairs Power contractor, 2NO + 2NC, 400 Amps, MCX-43, 4 Pole, 415 Volt grade, including making incoming and outgoing connections using thimbles / lugs / cables of appropriate size, complete all as specified and directed.Make : Legrand / L&T / Siemens / ABB 83 All as per item Sl No. 82.00 above but of 200 Amps, MCX-33 84 All as per item Sl No. 82.00 above but of 100 Amps, MCX-22 85 All as per item Sl No. 82.00 above but of 32 Amps, MNX-A1, 86 M & L for Dismantling of 16-meter high mast light from base using suitable capacity crane, including safe lowering, complete servicing and repairs such as cleaning and lubrication of winch and pulley system, inspection and replacement of wire rope and electrical components as required, testing of luminaires and wiring, and refixing the mast in its original position using crane, proper alignment for proper access to winch/ motor, electrical reconnection, and commissioning for full functionality complete all as specified and directed.Note: (a) Items like nuts, bolts, wiring cable etc deemed incl in quoted rate. (b) major items will measured and paid separately in respective item. 87 Supply & fix in repair LT panel of suitable size, CPRI approved, cubical floor mounted outdoor canopy type, factory made, totally enclosed, dust and vermin proof made out of 3.15mm thick MS sheet duly powder coated both side in and out, having suitable locking arrangments, 3 phase, 4 wire, 500V, 50Hz AC supply, suitable angle iron framed support, grouted in foundation in PCC 1:2:4 type B1 using 20mm graded stone aggregates. The panel shall have motor starter for a 1.5 HP, 3-phase motor with thermal overload protection and short-circuit protection & heavy-duty push buttons (green for UP, red for DOWN, and a STOP button) for manual operation, MCBs/ MCCBs of appropriate rating for 16mtrs high mast, LED indicators and 24-hour timer or photoelectric sensor for automated lighting control, contarctors, programable logic relay and cable terminals suitable for incoming and outgoing connections complete all as specified and as directed.Note: General layout of drawing of LT panel shall be approved by GE before incorpotaion in the work. 88 M&Lof high mast lighting system gearbox including dismantling of existing gearbox from the mast winch assembly, thorough inspection, cleaning, and overhauling; replacement of worn-out components such as worm gear set, bearings, oil seals, gaskets, and brake mechanism as required; refilling with suitable lubricant (SAE 90/140); reassembly and testing of the gearbox for smooth and safe operation, ensuring compatibility with the existing motor and winch system including taking down old unserviceable one complete all as sopecified and directed. 89 Supply and fixing in repair 6mm dia GI wire/ cable suitable for high mast light complete all as specified and directed 90 Supply and fixing in repair motor 1.5 HP, 3ph suitable for high mast light complete all as specified and directed. Make : Bharat Bijilee/ CG or equivalent. 91 M & L for PVC insulated, PVC sheathed, heavy duty electric cable with copper conductor, 1100volts grade, cross-sectional area 06 sqmm complete all as specified and directed. 92 S&F in repair solid state electronic type aviation obstruction light fitting 300 Nos LED with cast aluminium poly carbonate red colour, with control switch and connecting& testing complete on top of high mast light complete all as specified and directed. Make :-BAJAJ Model-BGAV 302 LED or equivalant 93 Supply & fixing in repair of Nature Switch Smart Timer based Automatic Street Light Control Panel suitable for 3-Phase load of 8kW (Navdeep-66-8kW3P) with 3 nos Incoming-Outgoing MCBs of 16-20 Amps & 3 nos Contactors (SP/2-pole/3-pole) of 20Amps & Circuit wiring (Copper) of 6 sq.mm. Maintenance-free Nature Switch Smart Timer settings accessible via a Mobile App with Bluetooth connectivity allow to customize the ON & OFF timings based on Natural Light (sensor), Local Sunset/Sunrise (Astro) and Time. The Smart Timer along with suitable Power Contactor(s) and Incoming-Outgoing MCBs fixed in a pole/wall mountable Rust Proof, Electric Shock Proof, Termite proof and FR grade thermoplastic polycarbonate enclosure conforming to IP66 protection class 2. The circuit have provision for Manual Operation (i.e. Sensor By-Pass option) & In 3-phase model, Controlling current phase selection option (at least from 2 phases) complete all as specified and directed. Make- Swadeep or equivalent 94 M & L for servicing and repair of solar street light systems, including inspection, cleaning of solar panels, checking and realigning of the mounting structure, and testing of battery performance and charging, MPPT charge controllers, and LED light fixtures. The work shall include preventive maintenance, identification of faults, replacement of defective components such as lights, controllers, and batteries with approved quality parts, repair or replacement of damaged wiring and connectors, ensuring proper dusk-to-dawn operation, tightening of pole fittings, and restoring the system to full functionality, complete all as specified and directed.Note:(a) The cost of battery charging, wiring, MPPT driver, nuts and bolts, minor sheet work, dismantling and reassembling of solar light components shall be deemed included in the quoted rate.(b) Spare parts, if required, shall be measured and paid for separately. 95 Supply only Solar panel 125 Wp with rugged polycrystalline solar cells for street light complete all as specified and directed. 96 Supply onlySolar battery 12V 105Ah for street light complete all as specified and directed. 97 Supply only Solar light 30watt for street light complete all as specified and directed. 98 Supply only 06m HDG tubular Pole, nuts, bolts & angle supports complete for street light complete all as specified and directed. 99 Labour onlyfor identifying, diagnosing, tracing, checking & rectifying LT faults, tracing location by meggering the lines, faults in panels, LT switch gears at any location, any time round the clock and rectifying it to restore the supply within time limit at various locations complete all as specified and directed.Note:- 1. All the activities to trace the fault and rectifying & restoring the supply shall be carried out within specific reasonable time as directed by the Engineer-in-charge. 2. The cost of required tools (T&P), minor items such as lugs, nuts, bolts, insulation tape and safety equipments required for the job are deemed to be included in the unit rate quoted against this item & nothing extra shall be paid by the department.3. Safety of manpower deployed for the job is contractor’s responsibility. In case of any accident / fatal injury, contractor shall be held responsible to settle all claims and nothing extra shall be paid to the contractor on this account.4. The cost of all manpower (any number) for the job is deemed to be included in the unit price.5. The cost of Fault identification by use of fault locator (if needed) is catered in separate Items. 100 M&L for detecting LT UG cable faults located in any stretch / depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave receiver, cable identification instrument , cable tracer for exact location of under ground cable routes complete all as directed.Note:- The rate quoted deemed to be inclusive ofarrangement of necessary fault locator equipment, transportation of equipment&charges for service engineer. 101 Repairs of Boom Barrier/boom gate (it is a bar, or pole pivoted to allow the boom to block vehicular or pedestrian access through a controlled point) including replacement of PCB, Control card, motor, power supply unit, suspension with mechanism, barrier cover, remote sensor i.e electromechanical complete all as specified abd as directed. Note: The contractor may visit the site and exmine the existing boom barrier at site before quoting their rates and no extra cost will be entertained by the department for this account. 102 M & L for servicing and maintenance of the existing tyre killer system to ensure reliable, safe, and efficient operation. To carry out thorough cleaning of the entire assembly, lubrication of mechanical moving parts such as spikes, hinges, and actuators, and inspection for wear, damage, or corrosion. All hydraulic or electromechanical components shall be tested for smooth and synchronized operation. Electrical wiring, sensors, and control units shall be checked for faults, and any loose or damaged connections shall be repaired. The work shall be carried out by qualified technicians. Minor spare requred deemed incl in quoted rate. 103 M & L for servicing and maintenance of the existing boom barrier system to ensure its smooth, safe, and uninterrupted operation. To carry out routine inspection, cleaning, lubrication of mechanical components, testing of the motor and control panel, checking and adjustment of limit switches, and calibration of sensors and safety devices. All electrical connections shall be inspected for faults, and the access control mechanisms. The work must be executed by trained personnel using appropriate tools and safety standards. Minor spare requred deemed incl in quoted rate. 104 Supply and fixing chain link MS galvanisd fencing made of 3.2mm dia wire with and including PVC coating of 1.3mm thickness and mesh size 50mm x 50mm complete all as specified and directed. 105 M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed 106 S&F danger notice plate of size 25 x 20 cm & 1.6mm thick mild steel sheet, fixed with M.S. clamps, bolts and nuts of approved size for HT including dismantling compete all as specified and as directed. 107 Surface dressing n exc 15 cm deep over area in soft/loose soil removing of old stone aggregates complete all as specified and directed 108 M&L for hard core of gauge n exc 63mm deposited spread and leveled in layers n exc 15cm thick watered and rammed to a true surfaces of broken stone or boulder complete all as specified and directed. 109 M&L for supply, fabrication, installation, connection, commissioning and testing of outdoor type LT panel box made out of 3.15 mm thick sheet metal cubical feeder pillar box canopy type Fondation mounted 3 ph 4 wire, 415V properly insulatedaluminium bus bar 04 Nos dust and vermin proof front open with locking arrangement comprising of Digital voltmeter, ammeter suitable ratio CT’s phase indicator selectorswitch danger board plate completely power coated, fixing in position by provision of plate form suitable size with brick work including fixing of glazed tiles over exposed surface and addition / alternation required for fixing and connections of coming/outgoing cables & including glands, lugs & thimblessuitable for fixing incoming and outgoing all as specified and directed by Engineer-in-Charge. (Main gate)Note: General layout of drawing of LT panel shall be approved by GE before incorpotaion in the work. Incomming:- (a) MCCB400 Amps, FP 415 Volts breaking capacity 36KA- 01Nos.(b)Onload type changeover switfh 400 Amps 50kA, 415 Volt, 50 Hz-01 Nos Out Going:-(a)MCCB200 Amps, FP 415 Volts breaking capacity 25 KA - 02Nos. (b)MCCB250 Amps, FP 415 Volts breaking capacity 25 KA - 02Nos.(c)Digital Volt and Ammeter - 01 Sets(d)Phase Indicator-01 Sets 110 All as per item No. 109.00 above but with followingincoming and outgoing (near futsal ground) Incomming:- (a) MCCB 400 Amps, FP 415 Volts breaking capacity 36KA- 01Nos. Out Going:-(a)MCCB125 Amps, FP 415 Volts breaking capacity 16 KA - 02Nos. (b)MCCB63 Amps, FP 415 Volts breaking capacity 16 KA - 03Nos(b)MCB 40 Amps, TP 415 Volts breaking capacity 10 KA - 02Nos.(c) Digital timer with contactor 3ph for street light - 01 set(d)Digital Volt and Ammeter - 01 Sets(e)Phase Indicator-01 Sets 111 All as per item No. 109.00 above but with followingincoming and outgoing (near Kalinga Bldg) Incomming:- (a) MCCB125 Amps, FP 415 Volts breaking capacity 16KA- 01Nos. Out Going:-(a)MCCB63 Amps, FP 415 Volts breaking capacity 16 KA - 03Nos. (b)MCB 40 Amps, TP 415 Volts breaking capacity 10 KA - 02Nos.(c)Digital timer with contactor 3ph for street light - 01 set(d)Digital Volt and Ammeter - 01 Sets(e)Phase Indicator-01 Sets 112 All as per item No. 109.00 above but with followingincoming and outgoing (near Kalinga Bldg) Incomming:- (a) MCCB400 Amps, FP 415 Volts breaking capacity 36KA- 01Nos. Out Going:-(a)MCCB125 Amps, FP 415 Volts breaking capacity 16 KA - 031Nos.(b)MCCB63 Amps, FP 415 Volts breaking capacity 16 KA - 02Nos.(c)MCB 40 Amps, TP 415 Volts breaking capacity 10 KA - 02Nos.(d)Digital Volt and Ammeter - 01 Sets(e)Phase Indicator-01 Sets 113 S&F in repair Dry chemical powder (ABC) type fire extinguisher 6 KG complete all as specified and directed. 114 S&F in repair CO2type (light weight squeeze grip type) fire extinguisher 4.5 KG complete all as specified and directed. 115 S&F in repair CO2 type (light weight squeeze grip type) fire extinguisher 2 KG complete all as specified and directed. 116 S&F in repair Mechanical Foam (AFFF) type fire extinguisher 9 Ltr complete all as specified and directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 97000.0 /-
Tender Value
INR 48.50 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail