Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | M&L for preparation of old decorated plastered surfaces of walls and applying one coat of white wash complete all as specified and directed. |
| 2 | M&L for preparation of old decorated plastered surfaces of ceiling/false celing and applying one coat of white wash complete all as specified and directed. |
| 3 | M&L for Preparation of old decorated plastered surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying one coat of distemper oil emulsion complete all as specified and directed. |
| 4 | Preparation of old painted wooden surface of any descriptionover10 Cm widths or girth and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 5 | Preparation of old painted steel surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified. |
| 6 | M&L forpreparation of old decorated plastered surfaces of walls by washing, rubbing down and stopping of distempered surfaces and applying two coat of distemper oil emulsion over one coat of wall care puttyincl complete removal of existing treatment complete all as specified and directed. |
| 7 | Taking down Cement plaster on concrete surfaces,brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.at any postion complete all as specifiedand directed. |
| 8 | M&L for Rendering 15 mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete surfaces complete all as specified and directed. |
| 9 | M&L for rendering 5 mm thick in cement mortar 1:3 on ceiling complete all as specified and directed. |
| 10 | M&L for Rendering 10 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces complete all as specified and directed. |
| 11 | M&L for preparing new surfaces and applying two coats of white washto external wall complete all as specified and directed. |
| 12 | M&L for preparing new surfaces and applying single coats of white washto ceiling complete all as specified and directed. |
| 13 | M&L for preparing new surfaces and applying two coats of distempering walls with distemper oil emulsion, white or tinted complete over chalk whitening, on plastered surfaces to internal walls complete all as specified and directed. |
| 14 | S&F in repair plastic water closet seat cover for EWC white closed pattern with flat bottom and cover and mild steel chromium plated hinging device complete all as specified and directed. |
| 15 | S&F in repair CP Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 16 | S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 17 | S&F for Curtain Rails, mild steel, chromium plated with fixing brackets, stops, rollers etc as in repairs complete all as specified and directed. |
| 18 | S&F in repairs of angle valve(stop valve) 15 mm dia CP fancy type, with long screwed shank and cup, cast copper alloy, screwed both ends for iron pipe or for unions complete all as specified and directed complete all as specified and directed. |
| 19 | S&F in repair of600 mm x 450 mm bevelled edge looking mirror of selected quality glass,mounted on 6mm thick AC building boards or commerical plywood and fixed to wooden plugs with chromium plated brass screws and cup washer complete all as specified and directed. |
| 20 | S&F in repairs15mmBib tap brass chromium plated, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 21 | S&F in repair grating doom 100mm dia of PTMT (Minimum weight 5gms) complete all as specified and directed. |
| 22 | S&F in repair brass CP tubular towel rail, 20mm dia, D type, 60cm long between flanges etc complete all as specified and directed. |
| 23 | S&F in repair Chromium plated shower roses 125mm size with swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed. |
| 24 | S&F in repair Vitreous China wash down water closet pan (Pedestal Pattern), white including white plastic seat cover with mild steel CP hinging device, suitable brass CP wash jet, flush pipe fixed as in repair complete jointing, connecting and making good the disturbed surfaces complete all as specified and directed. |
| 25 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premisesall as specified and directed. |
| 26 | M&L for Non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 27 | M&L for glazed coloured ceramic tiles in vertical surface 300x200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match existing surface including 10mm thick backing coat in cement mortar 1:4 complete all as specified and directed. Note : Item may be repaired to be done in patches also. |
| 28 | S&F in repair 19 mm thick prelaminated particle board, interior grade, prelaminated one side withdecorative choice lamination & other side balancing white lamination, as in cupboard/ drawers/ kitchen shelves shutters etc, including taking down existing including 5mm thick 2nd class hard wood lipping around the shutter complete all as specified and directed. |
| 29 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all as specified and directed. |
| 30 | S & F for 15mm dia GI pipe medium grade with all fittings and fixed complete to walls or laid in floors complete all as specified and directed. |
| 31 | Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all as specified and directed. |
| 32 | S & F 20 mm dia GI pipe medium grade with all fittings and fixed complete to walls or laid in floors complete all as specified and directed. |
| 33 | S&F in repair 15 mm bore pillar taps, cast copper alloy .with capstan heads.chromium plated screwed down high pressure,with or with out lettered \"Hot \" or \"Cold\" with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed. |
| 34 | S & F in repair Ball 20mm brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. |
| 35 | S&F in repair 10 Litres, PVC, valve less, syphonic action type, Flushing Cistern, high level, white inlet, ball valve, float, chain and pull, and brackets including PTMT PVC connection 600mm long complete all as specified and directed. |
| 36 | Treatment of sunken floor shall be tested for leakage / seepage / dampness by ponding with water for 72 hours. In case any defect is noticed the portion shall be grouted with cement slurry mixed with suitable chemical & tested again. The process of grouting and testing shall be repeated till leakage / seepage / dampness is eliminated and follows as per S. No. (i) to (vi) :- (a) Demolition ofconcrete of any description and in any position not otherwise specifically provided or in anytype of filling in sunken portion & cleaned the sunken potion incl vertical wall surface complete as directed.(b) S&F spouts of25mm dia GI pipe light grade projecting 450mm clear of face outer a wall with mosquito proof cap on inner face of pipe shall be provided to drain out seepage water ,including cutting holes and making good if needed as specified and directed.(c)M&L for Laying of 40mm thick (Min) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate with integral water proofing compound as per manufacturer instructions on bottom of sunken portion with proper slope towards spout. Bottom and vertical sides shall be plastered in cement mortar 1:3, 10 mm thick mixed with water proofing compound as per manufacturer instructions. Plaster shall be extended over PCC coving when the same is green i.e. PCC& plaster be carried out at the same time completeall as specified and directed. |
| 37 | (d) M & L for 5mm thick cement sand mortar (1:3) admixed with diluted DURAKRIT (1 Durakrit: 3 Water) at the junctions of the wall. Wet the surface with water to make it SSD condition. Apply one coat of DURAKRIT- Acrylic Polymer Modified Cementatious (PMC) slurry coating as per manufacturer specification 1:2 (1 DURAKRIT : 2 cement) by weight on the sunken floor surface; turned up and finished up to 100mm from FFL. Apply second coat of DURAKRIT - Acrylic Polymer Modified Cementatious slurry coating as per manufacturer specification 1:2 (1 DURAKRIT : 2 cement) by weight over the first coat at right angles. The second coat is usually applied after first layer slurry coat has touch dried usually after 4 hrs.completeall as specified and directed.(e) Test again of water tightness by ponding for 72 hours & rectify defects if any till total elimination of defects completeall as specified and directed.(f) M&L to fill the sunken floor with PCC(1:5:10) type E-2 using bk aggregate over the treated surface completeall as specified and directed. |
| 38 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/ slabs/blankets, any thickness including cover fillets complete all as specified and directed. |
| 39 | M & L for non asbestos fibre cement building board, 4mm thick, fixed to aluminium frame work with screw as in ceiling complete all as specified and directed. |
| 40 | M & L for preparation of new undecorated surface of ceiling and applying three coats of white wash complete all as specified and directed. |
| 41 | S&F in repair 32 mm dia PVC waste pipe of 850mm length for Sink/ WHB complete all as specified and directed. |
| 42 | Dismantling of existing unserviceableheating element from geyser and Supply & fixingnew heating element of 1.5 KW 230 volt suitable for 25 ltr to 35 ltrgeyser including testing and connection complete all as specified and directed. |
| 43 | Dismantling of existing unserviceableheating element from geyser and Supply & fixingnew heating element of 2.0 KW 230 volt suitable for 50 ltrs geyser including testing and connection complete all as specified and directed. |
| 44 | Dismantling of existing unserviceablethermostat of geyser for 50/25 Ltr capacity and Supply & fixing new thermostat matching to existing one including all connection, testing etc complete all as specified and directed. |
| 45 | S&F in replacement of 15 Amp,3 pin, 230volts, 50Hz plug top complete with all connection complete all as specified and directed. |
| 46 | S&F in replacementof PVC connection pipe 15 mm dia 60 cm long heavy duty with two Nos brass chromium plated union complete all as specified and directed. |
| 47 | S&F for stop valve chromium plated complete all as specified and directed. |
| 48 | S&F for indiacator lamp (red and green) complete all as specified and directed. |
| 49 | S&F for nut bolts and washers suitable for existing complete all as specified and directed. |
| 50 | Taking down geyser of any capacity, make, model, type from its position after disconnecting connection of geyser to take out to workshop for repairs and refixing back to its original position after repairs complete all as specified and directed.Note:- Spares parts shall be measured and paid seperately under appropriate items |
| 51 | M&L for Inner tank of any model/ make/ type /material for soldering at two to three places complete all as specified and directed. |
| 52 | M&L for Apparatus plate of any model/ make/ type /material complete all as specified and directed. |
| 53 | M&L for Glass wool suitable for insulation complete all as specified and directed. |
| 54 | M&L for CP brass base plate with adaptor matching to existing size complete all as specified and directed. |
| 55 | Taking down carefully aluminium / copper point wiring (light, fan, socket, power point) including batten, conduit, casing caping and fittings to match with existing surface complete removing from site, making good disturbed surfaces of wall, floor, ceiling complete all as specified and directed. |
| 56 | M&L for point wiring with 1.5 sqmm cable PVC insulated, unsheathed type, copper conductor, multistranded cable (FRLS Type), 1100 Volts grade (red colour cable for phase and black colour cable for neutral) including 1.5 sqmm copper conductor, multistranded cable (FRLS type) 1100 volts grade unsheathed PVC insulated ( green colour cable for earth wire) continuity earth wire connected to common earth dolly to be drawn in and including PVC casing capping, medium grade of suitable size including all fittings such as bend, elbow, tee, joint etc with sunk cast pressed steel terminal box made out of MS sheet with 3 mm thick hylum laminated sheet cover / plastic gang box for mounting of switch, socket,fan regulator complete all as specified and directed for following:- |
| 57 | Light / fan / bell point controlled by one number one way switch |
| 58 | 5 Amp s socket point on same board |
| 59 | 5 Amp switch socket point on independent board |
| 60 | All as per item Ser No 55.00 here in before but with 2.5 sqmm PVC insulated, unsheathed cable multistranded FRLS type, copper conductor (for phase & neutral) and 2.5 sqmm (for earth wire with same specification) for 6/16 Amp switch socket point on independent board complete all as specified and directed. |
| 61 | All as per item Ser No 55.00 here in before but with 4.0 sqmm PVC insulated, unsheathed cable multistranded FRLS type, copper conductor (for phase & neutral) and 4.0 sqmm (for earth wire with same specification) for 6/16 Amp switch socket point on independent board complete all as specified and directed. |
| 62 | M & L for point wiring with 1.5 sqmm cable PVC insulated, unsheathed type, copper conductor, multistranded cable (FRLS Type), 1100 Volts grade (red colour cable for phase and black colour cable for neutral) including 1.5 sqmm copper conductor, multistranded cable (FRLS type) 1100 volts grade unsheathed PVC insulated ( green colour cable for earth wire) continuity earth wire connected to common earth dolly to be drawn in and including PVCconduit, medium grade of suitable size including all fittings such as bend, elbow, tee, joint, junction box including cutting chases for concealed conduits/ sunken boxes and making good to disturbed walls,floors with sunk cast pressed steel terminal box made out of MS sheet for mounting of switch, socket,fan regulator with 3 mm thick hylum laminated sheet cover complete all as specified and directed for following:- |
| 63 | Light / fan / bell point controlled by one number one way switch |
| 64 | 5 Amp s socket point on same board |
| 65 | 5 Amp switch socket point on independent board |
| 66 | All as per item Ser No 58.00 here in before but with 2.5 sqmm PVC insulated, unsheathed cable multistranded FRLS type, copper conductor (for phase & neutral) and 2.5 sqmm (for earth wire with same specification) for 6/16 Amp switch socket point on independent board complete all as specified and directed. |
| 67 | S&F in repair / replacementof submain wiring with 2 X 1.5 sqmm, PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade alongwith 1 X 1.5sqmm PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade for continuous earth wire complete drawn through and including PVC casing caping, medium grade of suitable size with all fittings such as bend, elbow, tee, joint including making good the disturbed surface complete all as specified and directed. |
| 68 | S&F in repair / replacementof submain wiring with 2 X 2.5 sqmm, PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade alongwith 1 X 2.5sqmm PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade for continuous earth wire complete drawn through and including PVC casing caping, medium grade of suitable size with all fittings such as bend, elbow, tee, joint including making good the disturbed surface complete all as specified and directed. |
| 69 | S&F in repair / replacementof submain wiring with 2 X 4.0 sqmm, PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade alongwith 1 X 4.0sqmm PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade for continuous earth wire complete drawn through and including PVC casing caping, medium grade of suitable size with all fittings such as bend, elbow, tee, joint including making good the disturbed surface complete all as specified and directed. |
| 70 | S&F in repair / replacementof submain wiring with 2 X 6.0 sqmm, PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade alongwith 1 X 6.0 sqmm PVC insulated, unsheathed, copper conductor cable, multistranded, single core, FRLS type, 1100 volts grade for continuous earth wire complete drawn through and including PVC casing caping, medium grade of suitable size with all fittings such as bend, elbow, tee, joint including making good the disturbed surface complete all as specified and directed. |
| 71 | S&F in repair / replacement of switch piano flush type 5/6 amps, 230 volt, one way, single pole complete all as specified and directed. |
| 72 | S&F in repair / replacement of socket 5 pin, multipurpose type, 5 Amps, piano flush type, 230V complete all as specified and directed. |
| 73 | S&F in repair / replacement of switch socket combination 2 in 1, 5 pin, multipurpose type, 5/6 Amps, piano flush type 230 V complete all as specified and directed. |
| 74 | S&F in repair / replacement of switch socket combination 6 pin, multipurpose type, 15/16 Amps, piano flush type 230 V complete all as specified and directed. |
| 75 | S&F in repair / replacement of bell push switch, piano flush type 5 amps, 240 volts, single pole complete all as specified and directed. |
| 76 | S&F in repair / replacement of step type electronic fan regulator piano flush type, 230 Volts, 5 speed complete all as specified and directed. |
| 77 | S&F in repair / replacement of electric buzzer / ding dong bell, AC, 230 volt single phase complete all as specified. |
| 78 | S&F in repair / replacement of ceiling rose 3 terminals / PVC / Polycarbonate, isolated body, surface type with ISI marked 230 V complete all as specified and directed. |
| 79 | S&F in repair / replacement oflamp holder, PVC / polycarbonate type with back plate straight or angular, 230 volts suitable for batten fitting complete all as specified and directed. |
| 80 | S&F in repair / replacement ofmodular switch 1 way 10 Amps, 1 module, 230 volt complete all as specified and directed. |
| 81 | S&F in repair / replacement ofmodular switch 1 way 16 Amps, 1 module, 230 volt complete all as specified and directed. |
| 82 | S&F in repair / replacement ofmodular socket 1 way 6 Amps, 2/3 pin combined, 2 module, 230 volt complete all as specified and directed. |
| 83 | S&F in repair / replacement ofmodular socket 1 way 6/16 Amps, 3/3 pin combined, 2 module, 230 volt complete all as specified and directed. |
| 84 | S&F in repair / replacement ofmodular Bell Push Switch 10 Amps 1 module, 230 volt complete all as specified and directed. |
| 85 | S&F in repair / replacement ofModular type electronic fan regulator 2 module, 5 speed complete all as specified and directed. |
| 86 | S&F in repair / replacement ofswitch socket & plug combined in LM6 cable termination box in LM6, 25A, 2P+earth, 230V complete all as specified and directed. |
| 87 | M & L for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed. |
| 88 | M & L for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete all as specified and directed. |
| 89 | S&F for Rigid non-metallic PVC conduit external dia 25 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. |
| 90 | S&F for PVCcasing capping 25 mm size including fixing accessories such as couplers, lock nuts complete all as specified and directed. |
| 91 | S&F in repair of sheet metal enclosure, MCB DB, double door, single pole & neutral, 12 way, 230 volts, 50 Hz with suitable bus bar, neutral link, earth link complete all as specified and directed. |
| 92 | S&F in repair of sheet metal enclosure, MCB DB, double door, single pole & neutral, 8 way, 230 volts, 50 Hz with suitable bus bar, neutral link, earth link complete all as specified and directed. |
| 93 | S&F in repair ofsheet metal enclosure, MCB DB, double door, Triple pole & neutral, 4 way, 415 volts, 50 Hz with suitable bus bar, neutral link, earth link complete all as specified and directed. |
| 94 | S&F in repair ofSheet metal enclosure, MCCB DB, TP&N, vertical type, double door with bus bars, neutral links, blanking plates 4 way, 415 volts, 50 Hz suitable for mounting MCCB 4 pole, 100 Amps, 415 volts, 18 kA, fixed type as incomer complete all as specified and directed. |
| 95 | S&F sheet metal enclosure, MCB DB, double door, triple pole & neutral, 4 way, 415 volts, 50Hz loadline type with vertical busbar suitable for MCB as incomer and MCB SP/ TP as out going including suitable bus bar, neutral link, earth link complete all as specified and directed. |
| 96 | S&F in repairs MCB single pole, 6 to 32 Amps, 230 volts, 10 kA, C series complete all as specified and directed. |
| 97 | S&F in repairs MCB single pole and neutral, 32 Amps, 230 volts, 10 kA, C series complete all as specified and directed. |
| 98 | S&F in repairs MCB Triple pole and neutral, 40 to 63 Amps, 415 volts, 10 kA, C series complete all as specified and directed. |
| 99 | S&F in repairs MCCB Triple pole and neutral,100 Amps, 415 volts, 16 kA, fixed type complete all as specified and directed. |
| 100 | S&F in repair of ultra slim LED batten 10 Watt, 230Volts, 50 Hz, decorative ultra slim LED lighting fixture with extruded polycarbonate, environmental friendly including lamp, connection wire complete all as specified and directed.Make : Havells Cat Part No LHEXACP7INW10. |
| 101 | S&F for LED lights fitting 1 X 18/20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down old one complete all as specified and directed. Make : Havells Cat Part No LHEXAPP7PN1W020. |
| 102 | S&F in repairs of bulk head luminaire environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge -lit LED luminaire comprising of high brightness LEDs 10 watt, 230 volts, 50 Hz including lamp, connection wire complete all as specified and directed.Make : Crompton Cat Part No LBHE-10-CDL. |
| 103 | S&F in fix in replacemenetLED bulb 09 watt, B 22 inverter type, 230 volts, 50 Hzcomplete all as specified and directed.Make : Havells Cat Part No LHLDEGEDML8O009. |
| 104 | S&F in repairs of recessed mounted 36 watt (clear white) LED panel light 600 mm X 600 mm, ultra slim design, 230 volts, 50 Hz with CRCA sheet housing precoated white colour and high quality diffuser for uniform light and high efficiency with separate replaceable electronic driver including lamp complete all as specified and directed.Make : Havells Cat Part No LHEBAEP7IW1W036. |
| 105 | Taking down and refixing after repairs ceiling fans of any make/model/sweep in its original position, connecting and testing, including provision of cable from ceiling rose/connector to fan complete all as specified and directed. |
| 106 | Taking down and refixing after repairs exhaust fans of any make/model/sweep in its original position, connecting and testing, including provision of cable from ceiling rose/connector to fan complete all as specified and directed. |
| 107 | M&L for rewinding of ceiling fans 1200 /1400 mm sweep of any make/model, including removal of existing burnt windings completely and carefully from the slots, cleaning the slots thoroughly with necessary cleaning agent, applying slot insulation and rewinding with super enameled copper wire of existing guage complete including dismantling and re-assembling of starter, rotor, blades etccomplete all as specified and directed. Note:- Rate is inclusive of transportation to and fro from site to workshop in Tinsukia/ Dibrugarh.. |
| 108 | All as per item No.100 above but exhaust fans up to 300 mm sweep. |
| 109 | All as per item No. 100 above but exhaust fans 450 mm sweep. |
| 110 | M&L for cleaning / preparation of surfaces of ceiling fans up to 1400 mm sweep thoroughly and painting with one coat of spray painting (body and blades both) using synthetic enamel white paint over the existing paint and stenciling of MES No. with black paint over it complete all as specified and directed.Note:- (Rate is inclusive of filling of cavities with filler and matching to existing finishing of fans) |
| 111 | All as per item No. 103 above but exhaust fans up to 300 mm sweep |
| 112 | All as per item No.103 above but exhaust fans from 325 mm to 450 mm sweep. |
| 113 | S&F in repair of ball bearings, bearing No.6201 suitable for ceiling fans/wall mounted fans /exhaust fansof any make/model/sweep complete all as specified and directed. |
| 114 | All as per item No.106 above but bearing No.6205 |
| 115 | S&F in repair Oil type capacitor of 2.5 Mfd suitable for ceiling fans / wall mounted fans /exhaust fans /air circulator fans /table fans complete all as specified and directed. Make:- CAPCO/ TIBCOM/ HAVELLS/ UNIVERSAL/ SARDA |
| 116 | All as per item No. 108 above but 4.0 Mfd.Make:- CAPCO/ TIBCOM/ HAVELLS/ UNIVERSAL/ SARDA |
| 117 | S&F in repair gun metal bush suitable for ceiling fans/ wall mounted fans/ exhaust fans/ air circulator fans/ table fans of any make/ model/ sweep complete all as specified and directed. |
| 118 | S&F in repair rubber bush with bolt and nut suitable for ceiling fans/ wall mounted fans/ exhaust fans/ air circulator fans/ table fans of any make/ model/ sweep complete all as specified and directed. |
| 119 | S&F in repair split pin and jam nut suitable for ceiling fans / wall mounted fans/ exhaust fans/ air circulator fans/ table fans of any make/ model/ sweep complete all as specified and directed. |
| 120 | S&F in repair MS down rod 15 mm bore and 450 mm long including two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 121 | S&F in repair the canopy suitable for ceiling fan of existing type & size complete all as specified and directed. |
| 122 | S&F in repair MS clamp made of flat iron size 25 X 6 mm including nuts, bolts and \"S\" hook complete all as specified and directed. |
| 123 | M&L in repair of earthing complete with galvanised steel earth plate electrode 600 mm×600 mm× 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point/ DB including necessary earth work, common salt, char coal and earth pit as per electrical plate No. 3 of SSR Part-I complete all as specified or indicated point including testing on completion complete all as specified and directed. |
| 124 | S&F for GI Bracket for mounting of Street lights made out of 40 mm GI pipe medium grade 1.5 meters in length bend in shape as required including necessary MS flat iron clamps, nuts and bolts etc complete all as specified and directed. |
| 125 | S&F for GI Bracket for mounting of Street lights made out of 25 mm GI pipe medium grade 1.5 meters in length bend in shape as required including necessary MS flat iron clamps, nuts and bolts etc complete all as specified and directed. |
| 126 | S&F for 1100 Volts heavy duty round sheathed multistranded three core copper conductor cable of size 1.5 Sqmmfor electrical connections to the street lights fittings complete all as specified and directed. |
| 127 | S&F for 1100 Volts heavy duty round sheathed multistranded three core copper conductor cable of size 2.5 Sqmmfor electrical connections to the street lights fittings complete all as specified and directed. |
| 128 | S&F in repair of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp, surge protection device and corrosion resistant including thermal management complete with IP 65/66 protection complete all as specified and directed.Make : Crompton Cat Part No TRP-400-35-57-SL-LM-NSR. |
| 129 | S&F in repair of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp, surge protection device and corrosion resistant including thermal management complete with IP 65/66 protection complete all as specified and directed.Make : Crompton Cat Part No LST-60-CDL-M. |
| 130 | S&F in repairs ofLED flood light 100 watt 230 V ACoutdoor type with thermal management with IP66 protection and corrosion resistant complete with driver, surge protection deviceand lamp complete all as specified and directed.Make : Crompton Cat Part No CFS-504-100-57-60D-SL-GL-NSG. |
| 131 | S&F in repairs ofLED Post Top lantern 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection and corrosion resistant complete with driver, surge protection device and lamp complete all as specified and directed.Make : Crompton Cat Part No LPTO-40-CDL. |
| 132 | S&F in repairs ofpolycarbonate globe light 10 watt, 230 volts AC, unbreakable with B-22 type holder, IP-65 protection with & including 12W, B-22 type warm white LED bulb complete all as specified and directed.Make : Philips Cat Part No 582053 Globe Light. |
| 133 | S&F in replacement of LED bolard 10 W, 230 volts, 50 Hz, energy saving, environmental friendly, long life, die-cast aluminium housing, non integral, IP65 complete all as specified and directed.Make : Crompton Cat Part No LBLA1-10-CDL. |
| 134 | S&F in repair of240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single pole and capacity 10 to 32 Amp complete all as specified and directed. |
| 135 | S&F in repair of240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single pole and neutral and capacity 10 to 32 Amp complete all as specified and directed. |
| 136 | M&L for cleaning the swaged steel tubural street light pole 9 / 11 meters height including GI pipe of street light fitting and prepare surfaces cleaningincluding scrapping up of old corroded paint dirt/dust/ rust carefully and applying two coat of aluminium paint and marking of zebra crossings up to a height of 1.5m above the coping with blue andwhite strips of synthetic enamel paint including writing of pole numbers and two coats colour washing of PCC coping complete all as specified and directed. |
| 137 | Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation or for trenches for laying underground cables, poles, stay assemblies, pipes and getting out in soft/ loose Soil complete all as specified and directed. |
| 138 | Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation or for trenches for laying GI pipes, cables, pole, stay used for cable protection and getting out in hard/ hense soil complete all as specified and directed. |
| 139 | Returning/ filling including spreading, levelling and well ramming in layers not exc 25cm in thick ccomplete all as specified and directed. |
| 140 | Removal of surplus soil to a distance not exc 50 m away and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 141 | M&L for boring/ drilling (horizontally) hole manually under existing road, pavement, hard standing (maximum 10mtr in width) suitable for passing GI tubing upto 40 mm bore complete all as specified and directed. |
| 142 | Supply and spread sand in cable trenches and providing cushioning for the cable complete all as specified and directed.Note:- Only punned thickness of 18cm will be measured for the purpose of payment. |
| 143 | Supply and laying burnt brick sub class \"B\" of size 230 x115 x75mm for protection of cable, laying in trenches including taking out old complete all as specified and directed. |
| 144 | Supply and laying Pipes in repair galvanized iron Light grade for cable protection of size 25 mm bore complete all as specified and directed. |
| 145 | Supply and laying Pipes in repair galvanized iron Light grade for cable protection of size 40 mm bore complete all as specified and directed. |
| 146 | Taking out old serviceable/ unserviceable cable of size 2/4 core, up to 16 sqmm of any make/ type and keeping aside for the purpose of rerouting/ relaying in new location/ for requisite replacement/ further disposal complete including taking out bricks complete all as specified and directed.Note: Earth work shall be measured & paid separately. |
| 147 | M&L in repairs LT UG cable of size 2 core 10 Sqmm aluminium conductor XLPE insulated and sheathed armoured, heavy duty 1100 voltsin trenches/poles/surface and connecting with all accessories complete all as specified and directed. |
| 148 | M&L in repairs LT UG cable of size 4 core 16 Sqmm aluminium conductor XLPE insulated and sheathed armoured , heavy duty 1100 voltsin trenches/poles/surface and connecting with all accessories complete all as specified and directed. |
| 149 | Re-laying of serviceable (as obtained from taking out) cable of size 2/4 core up to 16 sqmm of any make/ type inclung making electrical connection complete all as specified and directed.Note: Earth work shall be measured & paid separately. |
| 150 | M&L for Straight through joint suitable for cable size 4 core 6 sqmm to 16 sqmm LT UGcable with necessary jointing materials and ferrule including cutting unserviceable portion of cable complete all as specified and directed. |
| 151 | S&F in repair of Rigid non metallic PVC conduit of dia 20 mm including of all tee, bends, elbows, reducers, and fixing such as couplers lock nuts, saddles, pipe hooks complete all as specified and directed. |
| 152 | S&F in repair of HOT moulded (FRP) SMC jucntion box for street light pole with locking arrangementt hinged door with IP -65 protection of size 205 x 255 X 112 with 32 Amp 4 way heavy duty terminal block with 10 Amps MCB SP and two steel bracket to fix with pole complete all as specified and directed. |
| 153 | M&L for sub main wiring2 runs of1.5 Sqmm PVC insulated FRLS cable multistranded copper conductor 1100 V grade flameproof conforming to IS drawn through and including suitable dia stove enamelled ERW MS conduit ISI marked and conduit accessories fixed on wall/ ceiling/floors for flameproof application connected upto DB and 1.5 sqmm copper earth wire for earth continuity conductor and connecting to common earth dolly including taking down old complete all as specified and directed.Note :- 3 runs of 1.5 sqmm cable and one length of MS conduit shall be measuredas one length. |
| 154 | M&L for earthing complete with copper plate 600mm x 600mm x 3.15mm thick electrode and 20 mm x 3 mm copper strip as earthing lead burried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to copper strip 20 x 3 mm as earth lead by means of tinned copper/ brass bolts, nuts, check nuts and washers (including brazing) connected to main switch board / panel/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 40mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I includoing taking out old complete all as specified and directed. |
| 155 | S&F in replacement of copper strip 20 mm x 3 mmwith fixing screws for conductors/ earth lead including brazing and nut bolts jointing at all joints for building/ equipment laid through pipe/ trench/ surface complete all as specified and directed. |
| 156 | S&F in replacement of gun metal black or phosphorus bronz size 75 mm x 75 mm x 25 mm drilled screwed including 3 Nos, 8mm dia and 25mm long neckhead screws including MS box 2mm thick of suitable size for protection of test point terminal complete all as specified and directed. |
| 157 | M&L for recharging of earthing pits by filling of common salt in earthing pits complete all as specified and directed.Note:- (i)Recharging materials shall be soluble in water and to be filled/ poured in earth pit after mixing in water in appropriate quantity.(ii) Recharging shall be carry out at site on requirement basis as per direction of GE. |
| 158 | M&L for PCC 1:2:4 type B-1 using 20 mm graded mechanically crushed stone aggregate as in foundation, sub base or mass concrete complete all as specified and directed. |
| 159 | Carrying out routine, preventive maint & servicing of DG set of under mentioned capacity, Make: Kirloskar/ Greaves in all respect like checking of diesel engine, multi cylinder and all safety devices, control panel by service engineer / service technician of any reputed service center/ auth service center of OEM periodicaly or on requirement basis and replacement of unserviceable spare parts/ accessories including calibration of control devices/ refitting of serviceable parts after cleaning/ servicing including minor consumables accessories like cotton, waste cloth, kerosene oil etc including draining of oil dust from foundation/ base plate complete all as specified and directed for the following under mentioned DG set:-(a)Check clearance of suction and exhaust valves including adjust, if required.(b)Changing of oil filter, fuel filters, water filter,screen filters assy, air filter etc.(c)Topping up of coolant & changing of hydraulic governer oil.(d)Tightening of all nut bolts including greasing of all points.(e)Checking of any leaking in fuel tank and oil lines.(f) Adjusting valve tappet clearance/timing, injector pressure test, cleaning and repairing,,tightining fasteners and making lubrication leak proof.(g)Repair/ rewiring of broken/ damaged control panel connection including measuring instruments, indicators, engine protection devices etc. Note . (a) Labour charges for dismantling/ taking down and replacement/ refixing parts as and when required is deemed to be included in unit item quoted rate.(b) Spare parts like oil filter, fuel filter, water filter, screen filter by pass filter, air filter etc will be measured and paid separately. |
| 160 | 50 KVA DG Set Make : Kirloskar |
| 161 | 40 KVA DG SetMake : Greaves. |
| 162 | Supply only fuel filter assembly to the DG set of various capacities complete all as specified and directed.for following DG set:-Note:-Labour charge for the same is paid under Schedule Sl item No. 1 |
| 163 | 50 KVA DG Set Make : Kirloskar |
| 164 | 40 KVA DG SetMake : Greaves. |
| 165 | Supply only air filter element to the DG set of various capacities complete all as specified and directed for following DG set:-Note:-Labour charge for the same is paid under Schedule Sl item No. 152 |
| 166 | 50 KVA DG Set Make : Kirloskar |
| 167 | 40 KVA DG SetMake : Greaves. |
| 168 | Supply only lubricating oil filter to the DG set of various capacitiesall as specified and directed for following DG set:-Note:-Labour charge for the same is paid under Schedule Sl item No. 152 |
| 169 | 50 KVA DG Set Make : Kirloskar |
| 170 | 40 KVA DG SetMake : Greaves. |
| 171 | S&F in replacement battery terminal cable, copper conductor with brass adaptor at both side of end point, multistrand, unsheathed, single core,25 Sqmm, 1100 volts grade in length of 1.5 mtr long suitable for 12 Volts & upto 180 AH battery complete all as specified and directed. |
| 172 | M&L for dismantaling the unserviceable radiator for DG set of capacity metioned in below from engine, transportation to the civil workshop or repair at site, repair the tank / storage portion including necessary welding/ brazing & making leak proof of the tank, cleaning the complete radiator with chemical agent and assembling the radiator including replacement of all old rusted MS nuts, bolts washers & gasket sets, refixing and testing complete for the following DG sets:- |
| 173 | 50/40 KVA DG Set Make : Kirloskar/ Greaves. |
| 174 | M&L for dismantling turbo-charger assembly with impeller & kit from the DG set of capacity mentioned below from engine, transportation to civil work shop for repair or repair at site, if possible, cleaning and carrying out inspection of each components/ spares segregation ofserviceable spares for reuse including decarbonising machine, cutting, grinding polishing etc. and re-assembling the turbo-charger after necessary repair/ maint complete for the following DG sets complete all as specified and directed:- |
| 175 | 50/40 KVA DG Set Make : Kirloskar/ Greaves. |
| 176 | M&L for dismantling of injector assembly ofthe DG set of under mentioned capacity from engine and repairing, cleaning and overhauling of the same with necessary calibration including replacement of defective item as required to make same fully fuctional for the following DG set:- |
| 177 | 50/40 KVA DG Set Make: Kirloskar/ Greaves. |
| 178 | M&L for spray painting (including bringing compressor of suitable size at site) old painted steel or iron surface of 40/50 KVA DG set complete with engine, alternator, radiator, exhaust hood and other standard fittings & attachments (including diesel tank & acoustic enclosure) as per existing colour scheme and pattern with atleast one coats of synthetic enameled paint after duly preparing the surface by cleaning with scrapers and emrey paper complete all as specified and directed.Note:- Contractor will apply one layer of greese over specification plate / any written letter before painting and clean the same after painting, rates for the same is deemed to be included in the item quoted rates. |
| 179 | S&F in replacement of on load changeover switch four pole, 200 Amps, 415 volts, 50 Hz in SS enclosure complete all as specified and directed.Note:- Cost of minor addition, alteration, fabrication work (if required) at site to fix properly deemed to be included in the quoted rates. |
| 180 | M&L for taking out self starter 12 volt from the DG set, transportation to civil workshop and opening/ disconnecting all internal connection, cleaning the same taking out burnt armature, segrigation of serviceable parts for re-use, rewinding of armature with copper wire of existing size, assembling all parts, testing & fixing back to the DG set complete all as specified and directed. |
| 181 | S&F in replacement of fuel pipe to the DG set of various capacities complete including clip complete all as specified and directed. |
| 182 | S&F in replacement fan V belt to the DG set of capacities 50/40 KVA complete all as specified and directed. |
| 183 | M&L forfinding out defects of fully automatic mains failure panel (AMF) of DG set of capacity 50/40 KVA and taking out burnt inter connection wiring including u/s and serviceable components for reuse and rewiring of panel using existing size of copper cable, ferrule, lugs, insulating material, nut, bolt, washer of various sizes, refixing serviceable items including replacement of contactor 240 volt suitable for 50/40KVA DG with auxiliary coil and testing complete for proper functioning complete all as specified and directed. |
| 184 | M&L for setting of valve timing chain for DG set of various capacities installed at 764 ASC BN. During the process of setting of valve timimg chain, open the air filter of the DG set and replaced the air filter and open the head of the DG set and set the the valve timing chain perfectorly and ensure the smooth functioning of the DG set without any unwanted sound complete all as specified and directed.Note:- Spare parts like fuel filter will be measured and paid separately. |
| 185 | M&L for dismantling of fuel pump assembly of DG set of under mentioned capacity from engine for repair, cleaning and overhauling of the same with necessary calibration including replacement of defective item as required to make fully functional for the follwing DG set:- |
| 186 | 50/40 KVA DG Set Make: Kirloskar/ Greaves. |
| 187 | Supply & topping up heavy duty concentrate/ anti freeze radiator coolant complete all as specified and directed. |
| 188 | Supply & topping up distilled water for batteries complete all as specified and directed. |
| 189 | S&F in replacement of rechargeable lead acid battery 12 Volt, 100 Ah heavy duty complete all as specified and directed. |
| 190 | S&F in replacement of water pump of DG set of capacity 50/40 KVA including all connected accessories complete all as specified and directed. |
| 191 | S&F switch mode power supply (SMPS) for DG set that make use to switching to regulator to transfer of electrical power supply to battery of the DG set so that the battery of DG set become charge at all the time complete all as specified and directed. |
| 192 | S&F in replacement of AVR as per exising model suitable DG set of capacity 50/40 KVA complete all as specified and directed. |
| 193 | Taking out unserviceable lubricant oil from engine chamber complete all as specified and directed. |
| 194 | Supply and filling lubricant oil 15w40 for topping up/replacement in engine chamber complete all as specified and directed. Make: Castrol/Volvoline/Servo/HP. |
| 195 | M&L for fixing of broken acoustic enclosure gate of DG set of any capacity/make by providing proper hinging and fixing in position including necessary welding/ nuts, bolts, washers as per existing size/ type complete all as specified and directed. Note: One side door will be measured & paid as one Job. |
| 196 | M&L for cleaning of fuel tank of DG Sets of 50/40 KVA capacities by taking out diesel in separate container, tank out of DG set, cleaning & removing all dirt/ sluge/ mud, dust, washing with fresh water thoroughly, drying and fixing back to its original location including making of all connection and re-filling of diesel in tank complete all as specified and directed. |
| 197 | S&F in replacement of battery charger 12 volts, 10 amps suitable for dg set AMF panel, operating range 170V to 270 Volts, Naurally air cooled, input over and under voltage protection, draws zero current from battery, wall mounting and with sheet metal enclouser complete all as specified and directed. |
| 198 | S&F in replacement ofAMF/Synchronizing controller Relay suitable for 50/40 KVA DG set of any make with following protection and features complete all as specified and directed.(a) Display 3Phase Mains parameter: Voltage& Frequency(b) Display of 3Phase Generator Parameter : Voltage, Frequency, Speed,Run Hours(c) Multi genset synchronizer & load share unit(d) Fault record with date and time stamp(e) Event record with date and time stamp(f) ATS/ATF/Remote start controller /Engine controller |
| 199 | M&L for cross arms, bracings, supports, clamps, back plates and stay clamp fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as required or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. |
| 200 | S&F in replacement of cast iron/ steel rotary barrel pump with dual direction operation with pipe and strainer complete all as specified and directed. |
| 201 | Material and labour laying well burnt old sizebricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail