Construction Of Ldc Building At Mangota- 1 Earthwork in excavation by manual means in trenches for foundations, drains, pipes, cables etc.(Not exceeding 1.5m in width) and for shafts, wells cesspits and the like notexceeding 10 sqm on plan, depth upto 1.5 mtrincluding disposal of excavated earth upto 1 mtr from cutting edge ,disposed earth is to be leveled and neatly dressed in (All kind of soil) 2 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 3 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 4 Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 5 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 6 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more 7 Centering and shuttering including strutting, propping, etc and removal of form work for 8 foundations , footings ,bases of columns, Plinth Beams etc. 9 Walls (any thickness) including attached pilasters, buttresses, plinth andstring courses etc 10 suspended floors,roofs,landings,balconies and access platforms, stairs and spiral stairs cases. 11 Edges of slabs and breaks in floors and walls Under 20 cm wide 12 Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate 13 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown 14 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 15 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Sal wood 16 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 17 Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws 18 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Second class deodar wood 19 Providing and fixing wire gauze shutters using galvanized M.S. wire gauze ofaverage width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction ofEngineer-in-charge Second class deodar wood 20 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to steel windows by welding 21 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as requiredIn gratings, frames, guard bar, ladder, railings, brackets, gates andsimilar works. 22 Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete : 300x16 mm 23 Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x10 mm 100x10 mm 24 Providing and fixing aluminum tower bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with necessary screws etc. complete : 25 250x10 mm 26 100x10 mm 27 Almunium Handle 125mm 28 Almunium Handle 100mm 29 Brick work with common burnt clay (Non-Modular) bricks of class designation 7.5 in foundation and plinth including curing complete in Cement mortar 1:6 ( 1 cement : 6 coarse sand). 30 Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level. 31 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) 32 15mm Cement plaster on the rough side of single or half brick wall of mix 1 : 6 ( 1 cement : 6 fine sand 33 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand) 34 Painting steel work with deluxe multi surface paint of required shade to give an even shade. Two or more coats applied @ 0.90litre/10sqm over an under coat of primer applied @ 0.80litre/10sqm of approved brand and manufacture 35 Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Riveted and bolted 36 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer 37 Finishing walls with acrylic smooth exterior paint of required shade onNew work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) 38 Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 39 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work 40 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.15mm nominal outer dia pipes. 41 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge 20mm nominal outer dia pipes 42 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc. 43 15mm nominal outer dia pipes 44 20mm nominal outer dia pipes. 45 External work including trenching, refilling etc 46 20mm nominal outer dia pipes 47 25mm nominal outer dia pipes 48 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid. 49 Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms 50 Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 51 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings.Flat back wash basin of size 630x450 mm. 52 Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms. 53 Providing and fixing un plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colourmm nominal bore with 45 cm length. 54 Providing and fixing mirror of Superior glass 55 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 56 Wiring for light point/Fan Point/ Exhaust Point/Call bell with 1.5 sqm FRS PVC Insulated copper conductor. 57 Wiring for light point/Fan Point/ Exhaust Point/Call bell with 1.5 sqm FRS PVC Insulated copper conductor 58 Providing and fixing G.I box with modulat plate 59 wiring for circuit /sub main 60 2x1.5xsqm+1x1.5xqm earth wire 61 2x2.5xsqm+1x2.5xqm 62 2x4xsqm+1x14xqm 63 ceiling Fan 64 Carriage of material from source to site of work by mechanical transport including loading /unloading and stacking complete. 65 Sand for an average distance of 155kms by M.T 66 Stone aggregate below 40 mm nominal size for anaverage distance 45 kms by M.T 67 Bricks for an average distance up to155 km by M.T