}

Tender For Civil Work Ranikhet Vikash Khand Dwarahat Gram Ena Ra U Ni Syetra Kuwali, almora-Uttarakhand

Panchayat Raj Department has published Tender For Civil Work Ranikhet Vikash Khand Dwarahat Gram Ena Ra U Ni Syetra Kuwali. Submission Date for this Tender is 04-07-2025. Earth Work Tenders in almora Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

49795050
Tender For Civil Work Ranikhet Vikash Khand Dwarahat Gram Ena Ra U Ni Syetra Kuwali
Tender
Indian
Uttarakhand
Almora
04-07-2025

Tender Documents

Tender Details

tender for civil work Ranikhet Vikash Khand Dwarahat Gram Ena Ra U Ni Syetra Kuwali-= 1 Earth work in excavation by mechanical means(Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2 Providing and laying in position cement concrete 1:4:8 (1cement :4fine sand:08graded stone aggregated 40mm .nominal size.) excluding the cost of centering and shuttering - All work upto plinth level 3 Providing and laying in position specified gradeof reinforced cement concrete, excluding the cost of centering,shuttering, finishing andreinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone 4 Reinforced cement concrete 1:1.5:3 work in beams,suspended floors,roofs etc. 5 Centering and shuttering for suspended floors, roofs etc including removal of form.Foundations, footings, bases of columns, etc. for mass concrete 6 Lintels, beams, plinth beams, girders,bressumers andcantilevers 7 Columns, Pillars, Piers, Abutments, Posts andStruts.. 8 Reinforcement for R.C.C. work includingstraightening, cutting, bending,placing inposition.using mild steel and medium / tensile steel bar. Thermo-Mechanically Treated bars of grade Fe-500D or more. 9 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth Cement mortar 1:6 (1 cement : 6 coarse sand) 10 Honey-comb brick work 10 / 11.4 cm thick with common burnt claybricks of class designation 7.5 in super structure above plinth levelupto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand). 11 Providing and fixing 25 mm thick shutters for cup 0 board etc. : Second class teak wood including 151 markedanodized aluminium butt hinges with necessary screws 12 Providing and fixing 1SI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneerson both faces of shutters: 30 mm thick including ISI marked Stainless Steel butt hinges 13 Structural steel work in single section fixed withor without connecting plate including cutting,IP hoisting, fixing in position and applying a priming• coat of approved steel primer all complete. 14 Cement concrete flooring 1:2:4 (1 cement : 2coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 15 12 mm thick cement sand plaster in 1:6 cis mortar 16 12 mm cement plaster finished with a floatingcoat of neat cement ofmix : 1:4 (1 cement: 4 fine sand) 17 Neat cement punning 18 Distempering with oil bound washable distemper of approved brandand manufacture to give an even shade :New work (two or more coats) over andincluding waternnable priming coat with cement primer 19 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 Itr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) 20 Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications :Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 21 Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint togive an even shade. Two or more coat applied @ 0.90 kr/10 sqm over an under coat of primer applied @ 0.80 kr/10 sqm of approved brand and manufacture 22 Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support 23 Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c cutting and making good the walls etc. 15 mm dia nominal bore 24 Providing and fixing G.I. Union in existing G.I. pipe line, cutting andthreading the pipe and making long screws, including excavation,refilling the earth or cutting of wall and making good the same completewherever required 15 mm nominal bore 25 Providing and fixing C.P. brass bib cock of approved quality conformingto IS:8931 : 15 mm nominal bore 26 Providing and fixing C.P. brass stop cock (concealed) of standarddesign and of approved make conforming to -8931. 15 mm nominal bore 27 Steel work welded in built up section/framed work including cutting, hoisting, fixing in position In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works. 28 Providing corrugated G.S. sheet roofing Including vertical/curved surface fixed 1.00mm thick with zinc coating not less than 275gm/m 29 Earth work in excavation by mechanical means(Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 30 Providing and laying in position cement concrete 1:4:8 (1cement :4fine sand:08graded stone aggregated 40mm .nominal size.) excluding the cost of centering and shuttering - All work upto plinth level 31 Providing and laying in position specified gradeof reinforced cement concrete, excluding the cost of centering,shuttering, finishing andreinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone 32 Reinforced cement concrete 1:13:3 work in beams,suspended floors,roofs etc. 33 Centering and shuttering for suspended floors, roofs etc including removal of form.Foundations, footings, bases of columns, etc. for mass concrete 34 Lintels, beams, plinth beams, girders,bressumers andcantilevers 35 Columns, Pillars, Piers, Abutments, Posts andStruts.. 36 Reinforcement for R.C.C. work includingstraightening, cutting, bending,placing inposition.using mild steel and medium / tensile steel bar. Thermo-Mechanically Treated bars of grade Fe-500D or more. 37 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth Cement mortar 1:6 (1 cement : 6 coarse sand) 38 Honey-comb brick work 10 / 11.4 cm thick with common burnt claybricks of class designation 7.5 in super structure above plinth levelupto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand). 39 Providing and fixing 25 mm thick shutters for cup 0 board etc. : Second class teak wood including 151 markedanodized aluminium butt hinges with necessary screws 40 Providing and fixing 1SI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneerson both faces of shutters: 30 mm thick including ISI marked Stainless Steel butt hinges 41 Structural steel work in single section fixed withor without connecting plate including cutting,IP hoisting, fixing in position and applying a priming• coat of approved steel primer all complete. 42 Cement concrete flooring 1:2:4 (1 cement : 2coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 43 12 mm thick cement sand plaster in 1:6 cis mortar 44 12 mm cement plaster finished with a floatingcoat of neat cement ofmix : 1:4 (1 cement: 4 fine sand) 45 Neat cement punning 46 Distempering with oil bound washable distemper of approved brandand manufacture to give an even shade :New work (two or more coats) over andincluding waternnable priming coat with cement primer 47 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 Itr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) 48 Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications :Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 49 Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint togive an even shade. Two or more coat applied @ 0.90 kr/10 sqm over an under coat of primer applied @ 0.80 kr/10 sqm of approved brand and manufacture 50 Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support 51 Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c cutting and making good the walls etc. 15 mm dia nominal bore 52 Providing and fixing G.I. Union in existing G.I. pipe line, cutting andthreading the pipe and making long screws, including excavation,refilling the earth or cutting of wall and making good the same completewherever required 15 mm nominal bore 53 Providing and fixing C.P. brass bib cock of approved quality conformingto IS:8931 : 15 mm nominal bore 54 Providing and fixing C.P. brass stop cock (concealed) of standarddesign and of approved make conforming to -8931. 15 mm nominal bore 55 Steel work welded in built up section/framed work including cutting, hoisting, fixing in position In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works. 56 Providing corrugated G.S. sheet roofing Including vertical/curved surface fixed 1.00mm thick with zinc coating not less than 275gm/m 57 Earth work in excavation by mechanical means(Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 58 Providing and laying in position cement concrete 1:4:8 (1cement :4fine sand:08graded stone aggregated 40mm .nominal size.) excluding the cost of centering and shuttering - All work upto plinth level 59 Providing and laying in position specified gradeof reinforced cement concrete, excluding the cost of centering,shuttering, finishing andreinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone 60 Reinforced cement concrete 1:1.5:3 work in beams,suspended floors,roofs etc. 61 Centering and shuttering for suspended floors, roofs etc including removal of form.Foundations, footings, bases of columns, etc. for mass concrete 62 Lintels, beams, plinth beams, girders,bressumers andcantilevers 63 Columns, Pillars, Piers, Abutments, Posts andStruts.. 64 Reinforcement for R.C.C. work includingstraightening, cutting, bending,placing inposition.using mild steel and medium / tensile steel bar. Thermo-Mechanically Treated bars of grade Fe-500D or more. 65 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth Cement mortar 1:6 (1 cement : 6 coarse sand) 66 Providing and fixing 25 mm thick shutters for cup 0 board etc. : Second class teak wood including 151 markedanodized aluminium butt hinges with necessary screws 67 Providing and fixing 1SI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneerson both faces of shutters: 30 mm thick including ISI marked Stainless Steel butt hinges with neccessary screws 68 Structural steel work in single section fixed withor without connecting plate including cutting,IP hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 69 Cement concrete flooring 1:2:4 (1 cement : 2coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate 70 12 mm thick cement sand plaster in 1:6 cis mortar 71 Neat cement punning 72 Distempering with oil bound washable distemper of approved brandand manufacture to give an even shade :New work (two or more coats) over andincluding waternnable priming coat with cement primer 73 Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications :Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 74 Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint togive an even shade. Two or more coat applied @ 0.90 kr/10 sqm over an under coat of primer applied @ 0.80 kr/10 sqm of approved brand and manufacture 75 Steel work welded in built up section/framed work including cutting, hoisting, fixing in position In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works. 76 Providing corrugated G.S. sheet roofing Including vertical/curved surface fixed 1.00mm thick with zinc coating not less than 275gm/m 77 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming ofbottoms, for all lift, including getting out the excavated soil and disposalof surplus excavated soil as directed, within a lead of 50 m. 78 Providing and laying in position cement concrete1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived fromnatural sources : 8 graded stone aggregate 40 mm nominalsize derived from natural sources) 79 Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing and1:2:4 (1 cement : 2 coarse sand (zone-lll) derived fromnatural sources : 4 graded stone aggregatereinforcement - All work up to plinth level : 80 Reinforced cement concrete1:1.5:3 work in beams suspended floor roof etc. 81 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete 82 Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers 83 Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts 84 reinforcement for R.C.C. work including straightening, cutting,bending, placing in position Mild steel and Medium Tensile steel bars Thermo-Mechanically Treated bars of grade Fe-500D or more. 85 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) 86 Brick work with F.P.S brick of class designation 75 in super structure above plinth cement mortar Cement mortar 1:6 (1 cement : 6 coarse sand) 87 Half brick masonry with common burnt clay F.P.S. (non modular) bricksof class designation 7.5 in superstructure above plinth level up to floorV level.Cement mortar 1:4 (1 cement :4 coarse sand) 88 Providing and fixing 25 mm thick shutters for cup board etc. :Second class teak wood including ISImarked anodized aluminium butt hinges with necessary screws 89 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part 1) non-decorative type, core of block board construction30 mm thick including ISI marked Stainless Steel butt hinges with necessary screwswith frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 90 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 91 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete.11.3.1 40 mm thick with 20 mm nominal size stone aggregate 92 Providing and fixing Ist quality ceramic glazed wall tiles conforming to1S: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of anysize as approved by Engineer-in-Charge, in skirting, risers of steps anddados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarsesand) and jointing with grey cement slurry @ 3.3kg per sqm, includingpointing in white cement mixed with pigment of matching shade complete. 93 Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% andconforming to IS: 15622, of approved make, in all colours and shades,laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joints withwhite cement and matching pigments etc., complete.Size of Tile 500x500 mm 94 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) 95 12 mm cement plaster of mix : 1:4 (1 cement:4 fine sand)finished with floating coat of neat cement 96 Neat cement punng 97 Distempering with 1st quality acrylic distemper (ready mixed) having VOCcontent less than 50 gram/litre, of approved manufacturer and of requiredshade and colour all complete to achieve even shade and colour : 98 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 Itr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) 99 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :painting wood work with Deluxe Multi Surface paint 100 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 101 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps 102 Providing and fixing white vitreous china water closet squatting pan (Indiantype)Orissa pattern W.C. pan of size 580x440 mm 103 Providing and fixing controlled flush, low level cistern made of vitreouschina with all fittings complete.10 litre (full flush) capacity-white 104 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 105 Providing and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and making good the walls etc.15 mm dia nominal bore 106 Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc.20mm dia nominal bore 107 Providing and fixingG.I. Union in existing G.I. pipe line, cutting andthreading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required 15 mm nominal bore wherever required : 108 Providing and fixing 15 C.P. brass bib cock of approved quality conformingto IS:8931 :15mm nominal bore 109 Providing and fixingC.P. brass stop cock (concealed) of standarddesign and of approved make conforming to IS:8931.15mm nominal bore. 110 Providing and fixing soil, waste and vent pipes :Sand cast iron S&S pipe as per 1S: 1729 111 Providing and filling the joints with spun yarn, cement slurry and cementmortar 1:2 (1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :100 mm dia pipe 112 Providing and fixing M.S. holder-bat clamps of approved design to Sand Castiron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes andmaking good the walls etc.For 100 mm dia pipe 113 Providing and fixing soil, waste and vent pipes Centrifugally cast (spun) iron socket & spigot(S&S) pipe as per IS: 3989 114 Providing and filling the joints with spun yarn, cement slurry and cementmortar 1:2 (1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 75 mm dia pipe 115 Providing and fixing M.S. holder-bat clamps of approved design to SandCastiron/cast iron (spun) pipe embedded in and including cement concreteblocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 gradedstone aggregate 20 mm nominal size), including cost of cutting holes andmaking good the walls etc. :For 75 mm dia pipe 116 Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I.surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation,foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coatof neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of classdesignation 7.5 117 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 118 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed 1.00 mm thick with zinc coating not less than 275 gm/m² 119 A Excavation in soil in Hilly Area by mechanical means Without useinng Dozerincluding cutting and trimming of side slopes and disposing of excavated earth witha lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1 120 B Excavation in Hilly Areas in Ordinary Rock by mechanical means not requiring blasting (With out Dozer) Excavation in hilly area in ordinary rock not requiring blasting by mechanical means without using Dozer including cutting and trimming of slopes and disposal of cut material with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2. 121 Excavation in foundation for retaining, breast walls etc, in all types of soils and rocksincluding all lead, lift and disposal of surplus material as per direction of engineer -in - charge, as per drawing and technical specifications Clause 305.1 122 concrete with cement coarse sand and 40mm gauge stone ballast in proportion 1:4:8 in foundation and floor including supply of all material. 123 Random Rubble Stone Masonry laid in 1:6 cement and sand mortar, in breast walls,retaining walls, parapets, scuppers, etc. including supply of all material, labour, T&Pand royaltiies etc. complete as per drawing and technical specifications 124 Providing concrete for plain/ reinforced concrete in open foundations completenominal mix 1:2:4( hand mixing) 125 Providing and fixing G.I. chain link fabric fencing of required width in meshsize 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts Made of G.I. wire of dia. 4 mm, PVC coated to achieve outerdia not less than 5 mm in required colour and shadeand washers as required complete as per the direction of Engineer-incharge 126 Structural steel work in single section, fixed with or without connectingplate, including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer all complete. 127 Providing and fixing G.I. pipes complete with G.I. fittings and clamps 25 mm dia nominal boreExternal work 128 Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc.20mm nominal bore 129 Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc.15 mm dia nominal bore 130 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. asrequired. 131 Supplying and fixing of following sizes of steel conduit alongwith accessories in surface/recess including painting in case ofsurface conduit, or cutting the wall and making good the samein case of recessed conduit as required.3 pin 5/6 A socket outlet 132 Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.5/6 amps switch 133 Supplying and fixing metal box of 150mm X 75mm X 60mmdeep (nominal size) on surface or in recess with suitable size ofphenolic laminated sheet cover in front including providing andfixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch,connections, painting etc. as required 134 Supplying and fixing following piano type switch/ socket on theexisting switch box/ cover including connections etc. as 2 way 5/6 A switch 135 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 136 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired.2 X 4 sq. mm + 1 X 4 sq. mm earth wire 137 Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired.2 X 6 sq. mm + 1 X 6 sq. mm earth wire 138 Supplying and fixing metal box of 180mm X 100mm X 60mmdeep (nominal size) on surface or in recess with suitable size ofphenolic laminated sheet cover in front including providing andfixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano typeswitch, connections, painting etc. as required 139 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thickincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe of2.7 metre long etc. with charcoal/ coke and salt as required. 140 Supplying and laying 6 SWG G.I. wire at 0.50 metre belowground level for conductor earth electrode, includingconnection/ termination with GI thimble etc. as required. 141 Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door 142 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, Ccurve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. Single pole. 143 Supplying and fixing following rating, double pole, 240 V,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required.63 A 144 Supplying and fixing brass batten/ angle holder includingconnection etc. as required. 145 Supplying and fixing 3 pin, 5 A ceiling rose on the existingjunction box/ wooden block including connections etc. asrequired. 146 Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required.

Key Value

Document Fees
INR 4720 /-
EMD
INR 294960.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail