| 1 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete.(Lift upto 0.00 to 1.50m.) By Manual Means (Item No. 21.01) |
| 2 | Providing dry/trap/granite/quartzite/gneiss rubble stone soling 15cm to 20cm thick including hand packing and compacting etc. complete. (Item No. 21.38) |
| 3 | Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/in plinth external walls including bailing out water manually, striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. (Item No. 27.01) |
| 4 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 24.01) |
| 5 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/granite/quartzite/gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.35) |
| 6 | Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/welded connections and painting complete. (Item No. 23.12) |
| 7 | Providing sacrificial shuttering for deck slab made up with galvanised Cold Rolled Cold Annealed(CRCA) steel of 310 MPA Grade with all Contractor\"s material, labour, erection fixing, welding etc.(Decking Sheet) (Item No. 17.70) |
| 8 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/granite/quartzite/gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.15) |
| 9 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/granite/quartzite/gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including,cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.35 (RA)) |
| 10 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/granite/quartzite/gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.54) |
| 11 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/granite/quartzite/gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant(Pan mixer) etc. complete. With fine aggregate(Crushed sand VSI Grade) (Item No. 25.74 (RA)) |
| 12 | Providing and fixing in position TMT-FE-500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (Item No. 26.33) |
| 13 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15cm to 20cm including watering and compaction etc. complete. (Item No. 21.37) |
| 14 | Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185(Part 3)-1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete.(The test shall be carried out conforming to IS:6441(Part I)-1972) (Item No. 27.15) |
| 15 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (Item No. 32.04) |
| 16 | Providing and applying laying Aggregate plaster in granite/marble stones, as decorative finish to give granite/marble like appearance to concrete, brick or block surfaces in all position including preparation of surface smoothly, evenly by racking of joints in case of Brick or block work including backing layer of 12mm thick with cement mortar 1:3 with 2% integral cement water proofing compound, roughening for wall keying hardening and drying the surface for a minimum five days gaps including second coat of cement lime mortar into a proportion 1:4 preparing the surface for three coat of marble finish plaster giving a thin coat of white cement and two parts of course calcite powder, applying the mortar with steel float on the surface in proper evenness applying at coat of white cement and lime to set a smooth finish then applying a thin coat of slurry made of white cement and black oxide colour in required proportion by the steel float to get black streaks on the surface and curing the surface for two days including all materials and labour etc. complete. (Item No. 32.29) |
| 17 | Providing and laying Polished Kota stone flooring With Hand-Cut Polished Kota Stones 25mm to 30mm thick and required width in plain/diamond pattern on bed of 1:6 Cement mortar including cement float, filling joints with neat cement slurry, curing, cleaning and Mirror Polishing etc. complete Note-Water absorption for kota stone should not exceed 0.05%.(Item to be used with prior permission of Superintending Engineer) (Item No. 33.75) |
| 18 | Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25mm to 30mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. (Item No. 33.81) |
| 19 | Providing and laying telephone black/Amba White/Cadburybrown/Ruby red/Ocean Brown granite stone of 18 to 20mm thick for door frame/dado/window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. (Item No. 33.68) |
| 20 | Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applyingwall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity.(With prior approval of S.E.) (Item No. 36.20) |
| 21 | Providing and fixing of factory made uPVC Sliding window & door(White Colour) complete, comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm(+-0.2mm), duly reinforced with G.I. section 1.5mm, wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256-more than 700Kj/m2 2 Vicat Softening Temperature EN ISO306 Shall not be < 750C 3 Charpy Impact Strength EN ISO179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner(a) For the tensile bending test EN514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame BS : 476-Part 7 Classification 1 8 Ignitability Evaluation BS : 476-Part 5 \"P\" Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa All corners of frame and sash will be fusion welded. After placing 5mm Float Annealed glass in the sash, uPVC glazing bead, interlock, EPDM/TPE gasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided. Window/Door will be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten(10) years against non-uniform discoloration, wrapping and rotting under general use. :: 3 Track 3/6 Sash(Big Series) window frame of size 122 x 54mm & Sash of size 64 x 47mm (Item No. 54.08b) |
| 22 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. (Item No. 40.01) |
| 23 | Solid Core Flush door Single leaf Providing and fixing factory made solid core flush door in single leaf 35mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202-1962(Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings, finishing with french-polish/waxing complete.(without door frame).(Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter (Item No. 51.60) |
| 24 | Providing and fixing on walls/ceiling/floor 25mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (Item No. 42.91) |
| 25 | Providing and fixing on walls/ceiling/floor 50mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. (Item No. 42.94) |
| 26 | Providing and laying in trenches 25mm dai. uPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (Item No. 42.97) |
| 27 | Providing and laying in trenches 50mm dai. uPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (Item No. 42.100) |
| 28 | Providing and fixing 75mm dia stabiliser pipe/P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete (Item No. 42.51) |
| 29 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete (Item No. 46.19) |
| 30 | Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. (Item No. 46.13) |
| 31 | Providing and laying damp proof course 50mm thick in M20 cement concrete layer and bitumen/using cement with waterproofing compound curing, formwork etc. complete. (Item No. 31.01) |
| 32 | Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid(2:1) by weight covering 9 to 10 Square Metre/Kilogram with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. (Item No. 31.09) |
| 33 | Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. (Item No. 42.07) |
| 34 | Providing and fixing 100mm dia stabiliser pipe/P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. (Item No. 42.52) |
| 35 | Removing earthen, stonewate pipe and stacking them as directed with all leads, lifts etc. complete. (Item No. 46.27) |
| 36 | Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer\"s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500-10mm dia 200mm depth (Item No. 53.02) |
| 37 | Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer\"s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500-16mm dia 320mm depth (Item No. 53.04) |
| 38 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. (Item No. 46.09) |
| 39 | Providing and fixing valley gutter of 22 B.W.G.(0.8mm) plain galvanised iron sheets 90cm wide with teak wood planking 20mm thick including two coats of coal-tarring the upper surface of plank etc. complete.(excluding painting to underside of plank). (Item No. 38.09) |
| 40 | Providing fly ash brick masonry with conventional/I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. (Item No. 27.12) |
| 41 | Providing and fixing on walls/ceiling/floor 40mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (Item No. 42.93) |
| 42 | Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. (Item No. 46.29) |
| 43 | Providing and fixing in position Gypsum board false ceiling with 12.5mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. (Item No. 38.51) |
| 44 | Providing and Fixing False Celling of PVC Laminated Sheet |
| 45 | Providing and fixing chicken mesh of 22 gauge, with about 30cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/B.B.masonry and or tying by binding wire etc. complete. (Item No. 32.26) |
| 46 | Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. (Item No. 42.12) |
| 47 | Removing plumbing from existing table, shifting table to the ground floor lab from 3rd floor Chemistry Lab, providing new pumbing to the table including material, labour, etc. complete. (Table Description: Size - 2.17m x 0.82m, Material - Granite counter top, metal bottom body, ceramic sink with J-shape sink cock) |
| 48 | Labour for shifting table to the ground floor lab from 3rd floor Physics Lab, etc. complete. (Table Description: Size - 1.53 m x 1 m, Material - Plywood counter top, metal body) |
| 49 | Providing and fixing in position extruded aluminium partitions having frame made out of extruded tubular section of size 65mm x 40mm with 12mm thick three layered flat pressed teak wood particle board bonded with BWP type exterior grade phenol formaldehyde synthetic resin conforming to IS 129231990, laminated on both sides, Novateak or equivalent with aluminium glazing clips of size 12mm x 12mm(conical) as per drawing etc. complete. (Item No. 39.73) |
| 50 | Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90m x 2.40m with aluminium door frame of powder coated section 101.60 x 44.75mm, 3.18mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150mm x 44.5mm x 3.00mm thick top rails 47.62 x 44.45mm x 3.00mm thick, vertical style 47.62 x 44.45mm, 3.00mm thick and for shutter plain glass panes 5mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc., I.S.I. mark, heavy duty, Hydraulic floor spring of 150Kilogramcapacity, having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials, labours, and equipment etc.Complete (Item No. 39.64) |
| 51 | Transportation of material obtained from excavatin including soil,rubble,bricks,RCC Concrete,kerb stone,steel railing,iron pipes channels etc. |
| 52 | Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5mm thickness in Global white color tile to be laid on grid systems with 15mm wide T-section flanges color white having rotary stitching on the Main Runner, 1200mm and 600mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5mm thickness in Global white color tile to be laid on grid systems with 15mm wide T-section flanges color white having rotary stitching on the Main Runner, 1200mm and 600mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete. (Item No. 38.48) |
| 53 | Providing and fixing M.S. grill door 24 Kilogram/square metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc (Item No. 39.31) |