| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | All kinds of soil. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level |
| 4 | 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | 1:5:10 (1 cement : 5 coarse sand(zone-III) : 10 graded stone aggregate 40 mm nominal size) |
| 6 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 7 | 1:5:10 (1 cement : 5 coarse sand(zone-III) including manufactured sand derived from Recycled concrete aggregate (RCA) up to 25% : 10 graded stone aggregate 40 mm nominal size including Recycled aggregate (RA)). |
| 8 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. |
| 9 | Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but, excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 11 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 13 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 14 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level up to floor V level. |
| 15 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 16 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.ird course of half brick masonry. |
| 17 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 18 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. |
| 19 | Using M.S. angels 40x40x6 mm for diagonal braces |
| 20 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete. |
| 21 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing the joints with white cement mixed with pigment of matching shade complete. |
| 22 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 23 | Single socketed pipes. |
| 24 | 110 mm diameter |
| 25 | 12 mm cement plaster of mix : |
| 26 | 1:6 (1 cement: 6 fine sand) |
| 27 | 15 mm cement plaster on the rough side of single or half brick wall of mix : |
| 28 | 1:6 (1 cement: 6 fine sand) |
| 29 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 30 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 31 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 33 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 34 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade. |
| 35 | Old work (one or more coats) |
| 36 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 37 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 38 | One or more coats on old work. |
| 39 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. |
| 40 | With cement mortar 1:4 (1 cement : 4 fine sand). |
| 41 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 42 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 43 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in- Charge. |
| 44 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer in-charge |
| 45 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 46 | Of area 3 sq. metres and below |
| 47 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
| 48 | For thickness of tiles 10 mm to 25 mm |
| 49 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 50 | 75 to 80 mm dia pipe. |
| 51 | 100 mm dia pipe |
| 52 | Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 53 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 54 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 55 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 56 | W.C. pan with ISI marked white solid plastic seat and lid |
| 57 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 58 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap |
| 59 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. |
| 60 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 61 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 62 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 63 | Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2\" BSP thread and shapes, weighing not less than 60 gms. |
| 64 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 65 | 20 mm nominal outer dia. Pipes. |
| 66 | 25 mm nominal outer dia .Pipes. |
| 67 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 68 | 25 to 40 mm nominal bore |
| 69 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 70 | 30 cm length |
| 71 | 15 mm nominal bore |
| 72 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 73 | 15 mm nominal bore. |
| 74 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 75 | 15 mm nominal bore. |
| 76 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: |
| 77 | (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. |
| 78 | (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. |
| 79 | (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. |
| 80 | (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 81 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). |
| 82 | Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 83 | Frame size 65 x 100 mm |
| 84 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. |
| 85 | 30 mm thick |
| 86 | Dismantling 20 to 25mm dia GI pipeline including stacking of dismantled pipes within 50m lead as per direction of Engineer in charge. |
| 87 | Rebate for taking away the unserviceable water supply lines/fittings including removing from the existing position . etc., complete. |
| 88 | GI pipes 15mm/20mm/ 25mm/ 32mm /40mm |
| 89 | Providing and fixing unplasticised Rigid PVC floor trap conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, including cost of cutting and making good the walls and floors : (a) 100 mm inlet and 75 mm outlet |
| 90 | Providing & fixing Type BSWR PVC pipes by cutting, removing, replacingincluding jointing with \"T\" shaped seal/rubber ring conforming to IS : 5382 and with solvent cement or rubber lubricant as the case may be with pipes of outer dia (concealed pipe joints to be jointed with rubber ring and solvent cement and exposed joints to be jointed with rubber ring and rubber lubricant. |
| 91 | 110mm diameter |
| 92 | 75mm diameter |
| 93 | Providing & fixing sanitary fittings/ accessories with new PVC SWR fittings /accessories including cutting, replacing, jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 94 | Plain Bend |
| 95 | 110mm diameter |
| 96 | 75mm diameter |
| 97 | Tee with door |
| 98 | 110X110X110 |
| 99 | 75X75X75 |
| 100 | Y- with door |
| 101 | 110mm diameter |
| 102 | 75mm diameter |
| 103 | Providing and fixing CPVC ball valve in CPVC pipe line including cutting and jointing with CPVC solvent cement etc complete as per directions of Engineer in charge. |
| 104 | 25 mm nominal bore |
| 105 | Providing and fixing 32 mm dia PVC rigid pipe forwash basin as waste pipe. The pipe shall be of length upto 600mm including P.V.C. waste fittings, P.V.C bend, union etc and fixing the pipewith clamps on wall surface, all as per site requirement, . All complete as directed by the Engineer in charge. |
| 106 | Providing and fixing 32 mm dia PVC rigid pipe forUrinal basin as waste pipe. The pipe shall be of length upto 450mm basin including all P.V.C. fittings, like P.V.C bend etc and fixing the pipewith clamps on wall surface, all as per site requirement, . All complete as directed by the Engineer in charge. |
| 107 | Providing and fixing 50 mm dia rigid PVC pipe as drain pipe near urinal basins. The pipe shall be fitted on the wall surface with necessary clamps at suitable intervals. Necessary diameter PVC \"TEE\" (REDUCER TEE) shall be fixed in this pipe line and arrangements shall be made such that the 32 mm dia waste pipe from the urinal basins shall be fixed properly in this 50 mm dia pipe ensuring proper draining. All complete and as per directions of the Engineer - in - charge. The 50 mm dia pipe shall be measured for payment and nothing extra shall be paid on any account. |
| 108 | Providing and fixing rectangular shaped urinal framelesspartition with 8mm thickfrosted toughened glassof required sizeincluding patch fittings of CP Brass or SSfor supporting wall and/or flooras per manufacturerspecifications complete as per direction of Engineer-in-charge . |
| 109 | a) 450X900mm |
| 110 | Dismantling anodized aluminium partitions and other frames including proper numbering, loading and unloading and stacking by placing at the required place in the building premises etc. all operations complete as directed by the Engineer-in-charge . (Area of partition is measured for payment) |
| 111 | Making and fixinganodized aluminium partitions for ventilators at all levels & heights using available materialspowder coated aluminum sections , particle board, glass panels and snap on beading including fixing with raw plug,screws or with fixing clips, or with expansion hold fasteners etc wherever required including necessary filling up of gaps at junctions at top, bottom and sides wherever required etc,all operations completeas perthe directions of the Engineer-in-charge. (Aluminiu partitions, particle board, glass, gaskets and snap beading will be supplied by BSNL at no cost). Area of aluminium partition making glass/boards is measured for payment. |