| 1 | Providingandlayinginpositioncementconcreteof specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 2 | 1:3:6 (1Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | 1:4:8 (1Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 6 | Lintels,beams,plinthbeams,girders,bressumersand cantilevers |
| 7 | Foundations,footings,basesof columns,etc.formass concrete |
| 8 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 9 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level. |
| 10 | Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 11 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 12 | 300x16 mm |
| 13 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 14 | 150x10 mm |
| 15 | 100x10 mm |
| 16 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 17 | 125 mm |
| 18 | 100 mm |
| 19 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 20 | Twin rubber stopper |
| 21 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. |
| 22 | G.I. pipes |
| 23 | 12 mm cement plaster of mix: |
| 24 | 1:4(1 cement: 4 fine sand) |
| 25 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture,including applying additional coats wherever required, to achieve even shade and colour. |
| 26 | Two coats |
| 27 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 28 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 30 | Two or more coats on new work |
| 31 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 32 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 33 | Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface |
| 34 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : |
| 35 | Of area 3 sq. metres and below |
| 36 | Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead : |
| 37 | Thickness above 10 mm up to 25 mm |
| 38 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in- charge. |
| 39 | Made of G.I. wire of dia 4 mm |
| 40 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 41 | All kinds of soil. |
| 42 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lif. |
| 43 | Providing and laying in position specified grade of reinforced cement concrete,excludingthecostofcentering,shuttering,finishingand reinforcement - All work up to plinth level : |
| 44 | 1:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 45 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 46 | Electric resistance or induction butt welded tubes |
| 47 | Providing and fixing mild steel round holding down bolts with nuts and washer plates complete. |
| 48 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 49 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 50 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: |
| 51 | Two or more coats on new work |
| 52 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 53 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : |
| 54 | 15 mm to 40 mm nominal bore |
| 55 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 56 | Flexible pipea) 40 mm dia |
| 57 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 58 | 20 mm nominal dia Pipes |
| 59 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work |
| 60 | 25 mm nominal dia Pipes |
| 61 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 62 | 30 cm lengtha) 15 mm nominal bore |
| 63 | Providing and placing on terrace (at all floor levels) polyethylene water storagetank,IS : 12701marked,withcoverandsuitablelocking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 64 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 65 | 15 mm nominal bore |
| 66 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 67 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 68 | Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-in-charge complete. |
| 69 | 205 X 19 mm |
| 70 | Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. |
| 71 | Anodized (AC 15) aluminium |
| 72 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 73 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). |
| 74 | Second class hard wood Cat.-II A |
| 75 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
| 76 | 4 mm thick Frosted glass pane (weight not less than 10kg/sqm). |
| 77 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. |
| 78 | Superior Hard wood Cat-II (A)a)35 mm thick Shutters |
| 79 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
| 80 | 12 mm thick plywood confirming to IS 710 |
| 81 | Providing and laying hollow cement concrete block walling upto floor five level 100mm thick consisting of hollow block of size 400x100x200mm of mix 1:3:6(1 :cement 3 :coarse sand 6 :graded stone aggregate 10mm nominal and down size) having a crushing strength of 3.5N/sqmm at 28 days as per IS:2185 (part-I) 1979 laid in cement mortar 1:6(1 :cement 6 :coarse sand) upto floor five level. |
| 82 | Providing and fixing ball valve (CPVC) of approved quality: |
| 83 | 25mm nominal bore |