}

Tender For Provision Of Auditorium For 600 Capacity At Ats Belgavi, Belagavi-Karnataka

Military Engineer Services has published Tender For Provision Of Auditorium For 600 Capacity At Ats Belgavi. Submission Date for this Tender is 14-08-2025. Auditorium Construction Tenders in Belagavi Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

49708803
Corrigendum : Tender For Provision Of Auditorium For 600 Capacity At Ats Belgavi
Tender
Indian
Karnataka
Belagavi
14-08-2025

Tender Documents

Tender Details

Tender For Provision Of Auditorium For 600 Capacity At Ats Belgavi; 2 GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XIII are prepriced by MES under Ser No. 1 to 13. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. 3 Lumpsum price worked out by the contractor for “Building or Works” as listed in Schedule ‘A’Part–I 4 Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’Part–II 5 Lumpsum price worked out by the contractor for “Internal Electric Supply as listed in Schedule ‘A’Part–III 6 Lumpsum price worked out by the contractor for “Road / Path as listed in Schedule ‘A’ Part - IV . 7 Lumpsum price worked out by the contractor for Area Drainage as listed in Schedule ‘A’ Part - V . 8 Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part – VI. 9 Lumpsum price worked out by the contractor for “Rain water Harvesting” as listed in Schedule ‘A’ Part – VII. 10 Lumpsum price worked out by the contractor for “Arboriculture” as listed in Schedule ‘A’ Part – VIII. 11 Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part – IX 12 Lumpsum price worked out by the contractor for “External Electric Supply” as listed in Schedule ‘A’ Part – X 13 Lumpsum price worked out by the contractor for “Water Cooler / Air Conditioning” as listed in Schedule ‘A’ Part – XI 14 Lumpsum price worked out by the contractor for Lightning Protection” as listed in Schedule ‘A’ Part – XII 15 Lumpsum price worked out by the contractor for Fire Alarm & Fire Fighting System” as listed in Schedule ‘A’ Part – XIII 16 Sch A Part - XIV : BUILDINGS OR WORKSDesign and Construction of 600 capacity auditorium inframed construction with permanent specifications in RCC of grade as per structural drawings, PCC solid block masonry walls, Wall panel, false ceiling, sound insulation, ATT, PU based WPT, 3 Nos 2000 litre PVC water tank for fire fighting, earthquake resistance as per latest IS and Green building norms with GRIHA 3 star ratingsetc complete all as specified and as shown on drawings. 17 Design and Construction ofPump house in single storey framed construction with permanent specifications in RCC grade of concrete as per structural drawings, PCC block masonry walls,ATT,PU based Water proofing roof treatment, Flooring work, internal/external finishes, earthquake resistance as per latest IS etc, complete all as specified and as shown on drawings. 18 Sch A Part - XV : Fittings / Fixtures & Misc items. INTERNAL WATER SUPPLYS&F 15mm bore angle cock cast copper alloy fancy type chromium plated for PPR pipe complete all as specified and as directed. 19 S&F 15mm bore, CP Two way Bib tap, cast copper alloy, chromium plated, fancy type, screwed down for iron pipe complete all as specified by the Engineer-in-Charge. 20 INTERNAL ELECTRIC SUPPLY Supply and fix LED luminaire 600 mm x 600 mm, 36/42 watt, 220 V AC recessed type/Ceiling Mounted with high efficiency PMMA diffuser IP 65 from top soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete in all respects all as specified and as directed Engineer in charge. 21 Supply and fix Step light suitable for auditorium/theatre in indoor application with low glare light LED 3watt,IP65 Protection, system efficacy at luminary level is ≥ 20 Lumens/watt, 3000K color temperature, total Lumens output 55, CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driverwithvoltage variation range - 150 to 270 Volts AC, Surge protection of 3 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmmcopper conductor flexible wire fixed complete in all respects all as specified and as directed Engineer in charge. 22 Supply and fix LED 2.2 watt Signage light fittings (EXIT)single sided for auditorium/theatre in indoor application ,2/3 hrs Battery Backup all as complete in all respects all as specified and as directed Engineer in charge. 23 Supply and fixhigh efficient Recessed mounted round LED down lighter 20/22 Watt, with housing made up of pressure die cast aluminium, Luminaire lumen Output- 1200 lm, CRI>80, color temperature-6500K, IP20, system efficacy at luminarie level ≥ 110 Lumens/watt , 50000 burning hours as per L70 criteria,Driver efficiency>80%, THD<10%, Power factor>0.95, Surge protection in CM-2.5 KV, Multistage Isolate CC-CV Operated driver with range 150-270V AC, Safety Extra Low Voltage Safe level<60V DC as per IEC standard including necessary fixing arrangement from truss complete in all respects all as specified and as directed Engineer in charge. 24 Supply and fixing mirror light of LED Aluminium extruded batten luminaire surface mounted, 2 feet system wattage of 10 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K,Minimum lumens output 1000,surge protection 3KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficacy at luminarie level ≥ 100 Lumens/watt andincluding connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete in all respects all as specified and as directed Engineer in charge. 25 Supply and fix high efficient Recessed/Surface mounted round LED down lighter 11/12/15 Watt, with housing made up of polycarbonate housing, Luminaire lumen Output- 1200 lm, CRI>80, color temperature-6500K, IP20, system efficacy at luminarie level ≥ 110 Lumens/watt , 50000 burning hours as per L70 criteria,Driver efficiency>80%, THD<10%, Power factor>0.95, Surge protection in CM-2.5 KV, Multistage Isolate CC-CV Operated driver with range 150-270V AC, Safety Extra Low Voltage Safe level<60V DC as per IEC standard including necessary fixing arrangement from trussall as complete in all respects all as specified and as directed Engineer in charge. 26 Supply and Fix 70/72 W High efficient LED Building Security light fitting around the building, Aluminium pressure Die cast housingwith pure polyester powder coated for long life, High purity lenses for superior performance, IP66 protection, Suitable for external pipe dia Up to 54 mm, with Luminiare efficacy >95 lm/W, driver Voltage range 150-270V AC, temperature range- 0 to 50 DegC, Driver efficiency > 85%, Power factor > 0.95, THD<10%, CRI >70, Colour Temperature- 5700K, ,Surge protection from overvoltage- 3.5KV in CM, Safety Extra Low Voltage Safe level<60V DC as per IEC standard, 50000 burning hours as per L70 Criteria, including provision of 40mm dia GI light grade pipe 1.2 mtr length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed all as complete in all respects all as specified and as directed Engineer in charge. 27 Supply and fix Extruded aluminium LED batten suitable for indoor application 20 watt , 4 feet complete including fixing arrangement to fix on Surface , Wall or steel truss mounted all as complete in all respects all as specified and as directed Engineer in charge. 28 Supply and fixhigh efficient Recessed mounted round LED 80 Watt dimmer light, with housing made up of pressure diecast aluminium, Luminaire lumen Output- 1200 lm, CRI>80, color temperature-6500K, IP20, system efficacy at luminarie level ≥ 110 Lumens/watt , 50000 burning hours as per L70 criteria,Driver efficiency>80%, THD<10%, Power factor>0.95, Surge protection in CM-2.5 KV, Multistage Isolate CC-CV Operated driver with range 150-270V AC, Safety Extra Low Voltage Safe level<60V DC as per IEC standard including necessary fixing arrangement from truss complete all as directed. 29 Supply and fixhigh efficient Floor mounted LED 150 Watt Focus light, with housing made up of pressure diecast aluminium, IP44, system efficacy at luminarie level ≥ 110 Lumens/watt , 50000 burning hours as per L70 criteria,Driver efficiency>80%, THD<10%, Power factor>0.95, Surge protection in CM-2.5 KV, Multistage Isolate CC-CV Operated driver with range 150-270V AC, Safety Extra Low Voltage Safe level<60V DC as per IEC standard including necessary fixing arrangement all as complete in all respects all as specified and as directed Engineer in charge. 30 Supply and fixhigh efficient LED 9/10Watt Bollard high level of durability with high impact resistance , with housing made up of pressure diecast aluminium, IP65, system efficacy Operated driver with range 150-270V AC, Safety Extra Low Voltage Safe level<60V DC as per IEC standard including necessary fixing arrangement all as complete in all respects all as specified and as directed Engineer in charge. 31 Supply and fix and connecting up Wall mounted Air Circulator swivel fan of size 600 mm sweep ,Minimum air delivery 250CMM,metal blades with pull cord mechanism for speed control complete with necessary fixing arrangement on acoustic panelled wall with suitable nut, bolts etc including writing MES No 2 cm height with synthetic enamel black paint all as complete in all respects all as specified and as directed Engineer in charge. 32 Supply and fix MCCB DB VTPN 4 way double door 415 V AC 50Hz including MCCBFP as incomer and TP,SP MCBs as out going with integrated door earthing system, tinned copper bus bar ,neutral link, earth link all as complete in all respects all as specified and as directed Engineer in charge. 33 Supply and fix MCB DB TPN 4 way double door,IP43, 415 V AC 50Hz for MCBFP as incomer and SP MCBs as out going with integrated door earthing system, tinned copper bus bar ,neutral link, earth link all as complete in all respects all as specified and as directed Engineer in charge. 34 Supply and fix MCCB DB VTPN 8 way double door 415 V AC 50Hz including MCCBFP as incomer and TP,SP MCBs as out going with integrated door earthing system, tinned copper bus bar ,neutral link, earth link all as complete in all respects all as specified and as directed Engineer in charge. 35 Supply and fix MCB DB SPN 4 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and SP MCBs as out going with integrated door earthing system, with tinned copper bus bar ,neutral link earth link all as complete in all respects all as specified and as directed Engineer in charge. 36 Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCBSPN as incomer and SP MCBs as out going with integrated door earthing system, with tinned copper bus bar ,neutral link earth link all as complete in all respects all as specified and as directed Engineer in charge. 37 Supply and fixMCB SP 6 to 32 Amps 240 volts 10 KA 50 HZ, C curve, Integrated level holder, colour coded on/off indication all as complete in all respects all as specified and as directed Engineer in charge. 38 Supply and fixMCB SPN 6 to 32 Amps 240 volts 10 KA 50 HZ, C curve, Integrated level holder, colour coded on/off indication all as complete in all respects all as specified and as directed Engineer in charge. 39 Supply and fixMCB TP 6 to 32 Amps 415 volts 10 KA 50 HZ, C curve, Integrated level holder, colour coded on/off indication all as complete in all respects all as specified and as directed Engineer in charge. 40 Supply and fixMCB TP32 Amps 415 volts 10 KA 50 HZ, C curve, Integrated level holder, colour coded on/off indication all as complete in all respects all as specified and as directed Engineer in charge. 41 Supply and fixMCCB FP 63 Amps, 415 volts, 10 KA 50 HZ with adjustable thermal and magnetic setting all as complete in all respects all as specified and as directed Engineer in charge. 42 ARBORICULTUREORNAMENTAL TREES :- Developing trees by excavating in post holes getting out , filling with red earth and manure in the proportion (3:1) and planting trees ofdifferent varieties 1.0 m to 1.5 m ht and 01 year old with proportionate girth in the filled up pits at a given distance etc; complete incl tree guards.(a) Mimusops Elengi (b) Peltaphorum pterocarpum(c)Jacaranda (d) CORDIA SEBESTENA (e) SPATHODEA 43 LAWN :- Developing lawn which includes necessary earth work excavation to a depth of 30 cm in any type of soil and removing the roots and vegetations from the soil to a distance not exc 50 mt and levelling and applying of soil pesticides,filling with sweet earth mixed with manure 30mm incl watering etc , dibbling of grass stellers of Mexicangrass, planting, rooting etc complete. 44 HEDGE :- Developing & Planting hedges by ht of 30 cm and above, 30 cm apart saplings including excavation in trenches to a width of 45 cm and depth of 45 cm and filling the trenches with mixture of vermin compost / farm yard manure and red soil in proportion of 2:3 with necessary pesticides treatment all as specified and as directed including watering, manuring, necessary pesticides etc; complete for perenial plants. (a) IXORA, (b) HIBISCUS, (c) GOUDI - CHOUDI, (e) GULPHINIA, (f) PLUMBAGO, (g) NERIUM OLIANDE,(h) TECOMA CAPSENSIS, (j) ERANTHEMUM 45 Supply and fix water sprinklers covering area 40 dia complete all as specified and as directed. 46 Maintenance of newly developed plants/ grass/ trees provided vide BOQ Sl. Item No. 40 to 42 by engaging well experienced Gardener all as specified and as directed.The maintenance shall includes the following:-(a) Periodical de-weeding of unwanted vegetation growth around the plants/ lawn area,(b) Watering all the plants/ lawn areas as required for proper growth,(c) Periodical Lawn mowing,(d) Periodical prunning the Hedges/ Shrubs and(e) Treating the plants and soil with required manure, pesticides and fertilizers including necessary topping of red earth. 47 EXTERNAL WATER SUPPLYSupply and lay 100 mm nominal dia ductile iron pipe , spigot and socket includingRubber joints , class K-9 complete all as specified and as directed.Note :- Specials and fittings will be measured and paid separately. 48 M&L forConstruction of brick masonry valve pit chamber of inner dimension 100x100x100cm suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in cement mortar 1:6, rendering in cement mortar 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, incl necessary earth work, including MS sheet cover of thickness 3.15mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement complete all as specified and directed. 49 EXTERNAL ELECTRIC SUPPLYSupply, Installation, testing and commissioning of 11 KV, 630 Amp Load break switch with 200 Amp DO set and earth switch unit Outdoor type Double Door (Sheet Thickness 3.15mm, 5mm Base) with necessary MS angle iron frame made of 40x40x4mm, totally enclosed, Manually operated, Metal clad contacts with ON-OFF Earth positions and with Automatic Trip from ON position to OFF position designed for Load-braking & Fault rupturing capacityService voltage - 11 KV, 3 phase, 50 HzNo of poles - Tripple poleOutgoing side- Trifurcating cable box suitable to connect XLPE cableIncoming side - Three Nos terminal suitable to connect XLPE cable 50 Supply and fix PVC insulated FR round PVC sheathed flexible industrial cable 2.5 Sqmm, 3 core 1100 volts grade, for connecting street light and loop in loop out box complete all as specified and as directed. 51 Returning and filling of trenches in two parts(i) using riddled soil obtained fromexcavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and(ii)refilling the trench of remaining depthwith normal excavated soil all as specified and directed.Note :- (i) Excavatedsoil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning. 52 Supply and fix DWC Pipe IS-16205, size inner dia 143 mm, outer dia 160 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at sitecomplete all as specified and as directed by Engr-in-Charge. 53 Supply and fix DWC Pipe IS-16205, size inner dia 103 mm, outer dia 120 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at sitecomplete all as specified and as directed by Engr-in-Charge. 54 Supply and fix DWC Pipe IS-16205, size inner dia 63 mm, outer dia 75 mm for cable protection in wall/under gorund laying of UG cables including SNAP-FIT Coupler and all fittings as required at sitecomplete all as specified and as directed by Engr-in-Charge. 55 Supply , install, testing and commissioning of LT feeder pillar box AC 415 V , 50 HZ 3 Phase 4 wire of suitable size for accomodating the following accessoriestotally enclosed self supporting structure / cubicle , fully compartmentalized type , suitable for outdoor use , with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm , with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs, hinged doors at front with suitable locking arrangement, Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated , complete all as specified and directed:- (Main Panel) 56 BUSBAR :-(i)Aluminium bus bar 600 Amps , supported on non hygroscopic fibres and brass screws for mounting -4 NosINCOMER(a) Supply and fixing MCCB of 4 poleof capacity 630 ampswith breaking capacity of 50 KA fixed thermal and fixed magnetic setting - 01 NosOUTGOING FEEDERS(a) Supply and fixing MCCB of four poleof capacity 250 ampswith breaking capacity of 25 KA fixed thermal and fixed magnetic setting - 02 Nos(01 No - APFC Panel , 01 No - Standby)(b) Supply and fixing MCCB of four poleof capacity 125 ampswith breaking capacity of 25 KA fixed thermal and fixed magnetic setting - 03 Nos(02 No - Tower AC panel + Spare)(c) Supply and fixing MCCB of four poleof capacity 100 ampswith breaking capacity of 25 KA fixed thermal and fixed magnetic setting - 03 Nos and 01 No Spare(01 No - Auditorium Panel + 01 No - Stage Accessories Panel + 01 No Fire Pump House Panel)(d) Supply and fixing MCB of fourpole , 415volts of capacity 16ampswith breaking capacity of 10 KAfixed thermal and fixed magnetic setting - 02 Nos (01 - Terrace Pump, 01 - Street Light Feeders)(e) time switches 415 V three Phase of 20 Amp rating with contactor - 01 No(f) Digital Metering Unit with ammeter, Voltmeter and Phase Indicator with Selector Switch 57 Supply and fix loop in loop out box with transparent lid IP 65 weather proof of suitable sizefixed to pole /wall with suitable FI clamp 20X3 mm nuts , bolts and washers incl provision of 01 No miniature circuit breaker (MCBs) single pole , 240 volts 10 KA 16 Amps and incl suitable capacity aluminium bus bar , complete all as specified and as directed 58 Supply and fix LT cable path indicators of oval shaped size 200mmX150mmX6mm thick made of or moulded cast iron and emborsing LT UG cable and fixed on MS angle iron 25x25x5mm thick 40 cm in length with two nos nut, bolts and washers, including two coats of synthetic enamelled paint over a coat of zinc coat primer on exposed surface, angle iron to be fixed in to the ground including suitable PCC work, while returning and filling the excavated soil complete all as specified and as directed. 59 Supply and fix HT cable path indicators of oval shaped size 200mmX150mmX6mm thick made of or moulded cast iron and emborsing HT UG cable and fixed on MS angle iron 25x25x5mm thick 40 cm in length with two nos nut, bolts and washers, including two coats of synthetic enamelled paint over a coat of zinc coat primer on exposed surface, angle iron to be fixed in to the ground including suitable PCC work, while returning and filling the excavated soil complete all as specified and as directed. 60 Supply , install, testing and commissioning of LT panel Box AC 415 V , 50 HZ 3 Phase 4 wire of suitable size to accomodating the following accessoriestotally enclosed self supporting structure / cubicle , fully compartmentalized type , weather proof , vermin proof indoor type made out of 2.0 mm thick MS sheet protection IP 54 , suitable for outdoor use , with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated with 400A electricalgrade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs ,CPRI approved type tested, internal wiring all includingthe following incoming complete all as specified and directed ( Auditorium Panel):- 61 (a) MCCB FP 100 Amps rating, 25 KA breaking capacity - 01 No. (Incoming)(b)MCCB Four pole 40 Amps rating, 25 KA breaking capacity - 04 Nos (Outgoing- 01 NoProjector / Rewinding RoomRoom, 01 No MCCB for Seating Area & other Spaces, 01 No for terrace pump panel & 01-Extra)(c) MCB SPN 6-32 Amps - 02 No (Bldg Security Light - 01 No & Garage Lighting - 01 No)(d) Digital Metering Unit with ammeter, Voltmeter and Phase Indicator with Selector Switch - 01 No(e) Indicator lamp LED type - 3Nos 62 Supply , install, testing and commissioning of LT panel Box AC 415 V , 50 HZ 3 Phase 4 wire of suitable size to accomodating the following accessoriestotally enclosed self supporting structure / cubicle , fully compartmentalized type , weather proof , vermin proof indoor type made out of 2.0 mm thick MS sheet protection IP 54 , suitable for outdoor use , with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated with 400A electricalgrade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs ,CPRI approved type tested, internal wiring all includingthe following incoming complete all as specified and directed (Stage Accessories Panel):- 63 (a) MCCB FP 100 Amps rating, 25 KA breaking capacity - 01 No. (Incoming)(b)MCCB Four pole 63 Amps rating, 25 KA breaking capacity - 02 No (Outgoing- 01 No MCCB for Stage and 01 NO Spare)(c) MCB SPN 6-32 Amps - 03 No ( 02 Nos out going and 01 Spare)(d) Digital Metering Unit with ammeter, Voltmeter and Phase Indicator with Selector Switch - 01 No(e) Indicator lamp LED type -01 No (Set of Three) 64 Supply , install, testing and commissioning of LT panel Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size to accomodating the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type , weather proof , vermin proof indoor type made out of 2.0 mm thick MS sheet protection IP 54, suitable for outdoor use, with bottom cable entry with suitable cable glands structure with angle iron frame work with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter and MCCBs, double hinged doors at front with suitable locking arrangement, Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated with 400A electricalgrade aluminium bus bar for phases and neutral complete with suitable digital type meters resin cast CTs, CPRI approved type tested, internal wiring all includingthe following incoming complete all as specified and directed (Tower AC Panel):- 65 (a) MCCB FP 125 Amps rating, 25 KA breaking capacity - 01 No. (Incoming)(b)MCCB Four Pole 63 Amps rating, 25 KA breaking capacity - 05 Nos (Outgoing- 04 No MCCB for TWO VTPN 08 Way and 01 No Spare)(c) MCB SPN 6-32 Amps - 02 No ( 01 No - 01 Spare)(d) Digital Metering Unit with ammeter, Voltmeter and Phase Indicator with Selector Switch - 01 No(e) Indicator lamp LED type -01 No (Set of Three) 66 WATER COOLERSupply andfix1 KVA Automatic voltage stablizer for AC of range 190V to 270V Output voltage stablizer at 230 voltage (+-)2.5% complete all as directed 67 AIR CONDITIONINGSupply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVAcomplete in all respects all as specified and as directed Engineer in charge. 68 SPECIAL ITEM (TOWER AC)Supply, installation, fixing and commissioning of tower AC type air conditionerof capacity 3TR,BEE & minimum 3 star rated, LCD display on unit ,with cordless remote control unit and inbuilt air ioniser, plasma filter for better indoor air quality, Noise level indoor 61db, antibactrial function, suitable for floor mounted three phase 415 volt 50 Hz all as required including suitable fixing arrange ment of outdoor and necessary connection etc all as specified and as directed by Engineer in charge.(Note : As per OEM recommended MS stand and all fixing arrangement for outdoor unit including gas charging is deemed to included in the item.) 69 Supply and fixing copper tube 1/4 inch wall thickness 23 SWG standards ASTM B68 Copper >99% temper soft anneled bright finish and inside carbon free including insulation as per OEM recommendation all as specified and as directed Engineer in charge. 70 MOTORISED CURTAINSupply, installation, testing & Commissioning of Three Layer Curtain System for Auditorium stage of height 8/10 mtr and width 23 mtr consisting of following itemsA. Stage Curtain Motor with track -Providing and facing horizontal main curtain, the complete automatically motorized stage curtain system with additional modified gear box fitted with sealed bearing, self lubricating centre split overlapped curtains both sides opening. fully automatic stage curtains fixing steel rails track made out of 450 GSM out of double gathering Amoshi or Hitech fabric curtain cloth drapery horizontal sliding arrangement complete with fixing rails, brackets and motorized operation complete with runners master runners, bullies 3mm steel wire rope 1 HP motor (Crompton or Godrej) 3 Nos Air Breaker contactors (L&T/ Siemens) 03 Nos Micro switches for auto stop, 06 Nos push buttons for forward/backward all rollers are sliding with roller clamps, the curtains should be half of full width operated from control panels switches, Provision is for fully automatic operation only.B. Curtain Control Module- Make : Creston Model : DIN-85W8-I or equivalent makes DN Rail Relay, 1 feed 8 Channels for 230 V on/ Off for curtain controlC. HVAC Control Module- Make : Cool Automation Model : Coolnel or equivalent makes2way HVAC control module which supports VRV & VPF HVAC Outdoor SystemsD. Control Processor for Complete Curtain Control Systems-Make : Creston Model : MC3 or equivalent makesCreston 3Series control system with 2-RS232, 5 IR, 4 Relay, 21/0 Ethernet, Cresnet for complete curtain control from user interface including Cables, mounting kits connectors and all required accessories complete all as specified and directed. 71 DG SETSupply, install, testing and commissioning of acoustic proof CPCB -IV Norms diesel engine driven generating set, fully wired, 415 Volts, AC, 3 phase 4 wire, 50Hz having capacity 320KW/400 KVA continuous rating at power factor 0.8 (lagging) as per IS-4722 and connections as per IE rules complete with Water cooled 4 stroke Diesel engine with electric start with 12Volts DC battery, developing minimum 604.1 BHP at 1500 RPM under NTP prevailing at Sambra area, Belagavi considering derating factor and shall conform to IS:10000/150 3026/BS-5514 with provisions of 10% over loading for 1 hour for every 12 hours running with A1 class governing and all standard safety type, screen protected, revolving field, self excited, self regulated alternator conforming to BSEN-60034 with IP 23 protection complete with integrated AMF control panel with microprocessor based relays/MCCB/MCBs/Contactors, multifunction meter showing KWH, KVA, PF, Amps, Volts, frequency, indicating lamps, 12 Volt battery charging unit including 12 Volts battery etcrequired as per latest standard engineering practices including sound proof canopy designed to meet MoEF/CPCB Norms of 75 dBA at 1mtr at 75% load, fabricated from CRCA sheet and a structural/sheet metal base frame, with high quality noise absorbent and fire retardant grade acoustic insulation material conformity to IS : 8183 and integrated fuel tank of capacity not less than minimum 8 hrs running fuel filling arrangement from inside duly painted after necessary pre treatment process 72 required as per latest standard engineering practices including sound proof canopy designed to meet MoEF/CPCB Norms of 75 dBA at 1mtr at 75% load, fabricated from CRCA sheet and a structural/sheet metal base frame, with high quality noise absorbent and fire retardant grade acoustic insulation material conformity to IS : 8183 and integrated fuel tank of capacity not less than minimum 8 hrs running fuel filling arrangement from inside duly painted after necessary pre treatment process complete all as specified and as directed.Make : Cummins / Kirloskar / Greaves Cotton / Ashok LeylandMake of Alternator: Stamford / Kirloskar / Crompton GreavesNote: (i) Quoted rate is deemed to be included the cost of PCC foundationas per the recommendation of OEM.Note: (i) Quoted rate is deemed to be included the cost of PCC foundationas per the recommendation of OEM. (ii) Quoted rate is deemed to be included the cost of fuel and other expenses for carrying out acceptance test of the DG set all as specified and directed. 73 FIRE ALARM & FIRE FIGHTING SYSTEMSupply, Installation, Testing & Commissioning of remote controlled terminal fault tolerant (Repeater Panel) complete all as specified and as directed by Engr-in-Charge. Make : IBL/Halma/Noveltech. (Stn Fire Sec) 74 Supply install testing and commissioning of analogue addressable type control relay module for AHU with UL based integration all as directed. Make : Honeywell/System sensor/Spencers 75 Supply and laying 2 Core 1.5 Sqmm copper cable shield sheathed twisted pair FRLS, HFC wires each core insulated with FRLS sheathed completethrough and including stove enamelled metal conduit 20mm diafixed/concealed in walls, ceilings etc all asdirected. 76 Supply install testing and commissioning of sprinkler annunciation control panel with audio visual indications, relay logic type complete with water release module and Auto / Manual release mode,auto with built in timer (settable) & emergency manual over ride switchMake : Honeywell/System sensor/Spencers. 77 Supply and laying 2 Core 1.5 Sqmm copper FRLSH cable armouredcompletefixed in walls, ceilings etc all asdirected. 78 Supply and erect MS pedestal stand duly painted for suspending fire bucketscomplete all as specified and as directed. 79 Supply only MS fire bucket of 13 ltrs capacity of fire approved quality(IS:2546), painted Red filled with sandcomplete all as specified and as directed. 80 Supply onlyFoam Type Extinguisher Hand 5 kg (IS:15683) complete all as specified and directed by Engr-in - charge. 81 Supply only DCP type (ABC) 9 Kg designed/tested IS 15683 with safety release valve, NRV and CE approved valve. Dry powder IS 14609 with standard accessories complete all as specified and directed by Engineer- in-Charge 82 Supply only CO2 type Hand 5 Kg with wheel as per IS 15683 complete with hose, screw valve, CO2 gas IS 1522, cylinder IS 7285, valve IS 3224. Tested at 250 Kgf/cm2 all as specified and directed by Engineer- in-Charge 83 Supply and fixing in position the following type of sign boards made out of 3.00 mm thick Opaque PVC foam board with computer cut, PVC non reflective self adhesive vinyl painted foam board complete with mirror fasteners all as directed. [a]Floor identification signage of size 15 CM x 60 CM (GROUND FLOOR… etc)at each stair case enclosure on every floor, indicating the floor number in words, with lettering size 7.5 CM with contrasting colour from back ground. 84 Supply and fixing in position assembly point signage of size 600 x 400 mm made out of 3.00 mm thick Opaque PVC foam board with computer cut, PVC non reflective self adhesive vinyl painted foam board complete with mirror fasteners all as directed 85 Supply and fixing in position the signages FIRE ORDER boards 3 x 4 size made out of 3.00 mm thick Opaque PVC foam board with computer cut, PVC non reflective self adhesive vinyl painted foam board complete with the following text all as directed. [A]ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINTLOCATED AT STRATEGIC LOCATIONS.[B] EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE ATVARIOUS ASSEMBLY POINTS.[C] IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTBLE EXTINGUISHER OR WATER FROM NEAREST WET RISER.[D] BE CALM AND DO NOT GIVE ANY ROOM FOR PANIC, WALK, DO NOT RUN.[E] IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, LIE DOWN FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM. 86 Supply and fixing in position the signages FIRE ORDER boards 3 x 4 size made out of 3.00 mm thick Opaque PVC foam board with computer cut, PVC non reflective self adhesive vinyl painted foam board complete with the following text all as directed. ACTION BY SECURITY / RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM.[A] ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM[B]INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS:---------------- (Current phone numbers to be provided in this location by the contractor).[C] REFER EVACUATION PLAN FROM EVACUATING STANDARD PEOPLE. [D] GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE. [E]IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER ------------------(Current phone numbers to be provided in this location by the contractor)[F]FIRE FIGHTING AGENCY: PHONE : --------------------(Current phone numbers to be provided in this location by the contractor). FAX: ---------------------(Current Fax numbers to be provided in this location by the contractor) 87 Supply , install, testing and commissioning of LT panel box AC 415 V , 50 HZ 3 Phase 4 wire of suitable size for accommodating the following accessoriestotally enclosed self supporting structure / cubicle , fully compartmentalized type , suitable for indoor use , with bottom cable entry with suitable cable glands structure made out of 2.0 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm , with four legs grouted to PCC (1:2:4) type B1 , foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter , changeover switch and MCCBs , hinged doors at front with suitable locking arrangement , Provision of louvers at sides , structure treated under 8 - tank metal treatment process and duly powder coated , complete all as specified and directed:- (Fire Pump House Panel) 88 BUSBAR :-(i)Aluminium bus bar 400 Amps , supported on non hygroscopic fibres and brass screws for mounting -4 NosINCOMER(a) Supply and fixing MCCB of 4 poleof capacity 125 ampswith breaking capacity of 25 KA fixed thermal and fixed magnetic setting - 01 NosOUTGOING FEEDERS(a) Supply and fixing MCCB of 3 poleof capacity 100 ampswith breaking capacity of 25 KA fixed thermal and fixed magnetic setting - 01 Nos(a) Supply and fixing MCCB of 3 poleof capacity 32 ampswith breaking capacity of 10 KA fixed thermal and fixed magnetic setting - 02 Nos(b) FASD Starter with SPP for 80 HP pump set with illuminated LED type flush mounted Push Buttons for Start / Stop-01 Nos(c) FASD Starter with SPP for 10 HP pump set with illuminated LED type flush mounted Push Buttons for Start / Stop-01 Nos(c) Digital Metering Unit with ammeter, Voltmeter and Phase Indicator with Selector Switch - 03 Nos(d) Indicator lamp LED type -03 Nos (Set of Three) 89 Supply , install, testing and commissioning of LT feeder pillar box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size for accommodating the following accessoriestotally enclosed self supporting structure / cubicle, fully compartmentalized type, suitable for indoor use, with bottom cable entry with suitable cable glands structure made out of 2.0 mm thick CRCA steel sheet with angle iron frame work and legs of ISA 50X50X5 mm , with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars voltmeter, ammeter, changeover switch and MCCBs, hinged doors at front with suitable locking arrangement, Provision of louvers at sides, structure treated under 8 - tank metal treatment process and duly powder coated , complete all as specified and directed:- (Jockey Pump Panel) 90 BUSBAR :-(i)Aluminium bus bar 200 Amps , supported on non hygroscopic fibres and brass screws for mounting -4 NosINCOMER(a) Supply and fixing MCCB of 4 poleof capacity 40 ampswith breaking capacity of 10 KA fixed thermal and fixed magnetic setting - 01 NosOUTGOING FEEDERS(a) Supply and fixing MCCB of 3 poleof capacity 32 ampswith breaking capacity of 25 KA fixed thermal and fixed magnetic setting - 02 Nos(b) FASD Starter with SPP for 10 HP pump set with illuminated LED type flush mounted Push Buttons for Start / Stop-02 Nos(c) Digital Metering Unit with ammeter, Voltmeter and Phase Indicator with Selector Switch - 03 Nos(d) Indicator lamp LED type -03 Nos (Set of Three)

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 14-07-2025 AMENDMENT 01 Date 05-08-2025
2 28-07-2025 Corrigendum No. 2 Date 14-08-2025

Key Value

Document Fees
INR 3000 /-
EMD
INR 1203600.0 /-
Tender Value
INR 17.57 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail