| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-06-2025 | Tender documents | Other | 04-07-2025 |
| Sl. No. | Item Description |
| 1 | Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal ofdebris and rubbish complete all as directed by the Engr-in-Charge |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal ofdebris and rubbish complete all as specified and directed. |
| 3 | M & L for 25 mm thick, plain cement concrete 1:2:4,type B-0 (using 12.5 mm graded stone aggregate)as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed. |
| 4 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6complete all as specified and directed. |
| 5 | M & L for 75 mm thick,plain cement concrete1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed. |
| 6 | M & L for 75 mm thick, Plain cement concrete 1:2:4,type B-2 (using 40 mm graded stone aggregate)as in base footpath, etc and finished the surface even and rough to receive the screed bed complete all as specified and directed. |
| 7 | M & L for Chequered cement concrete coloured tiles of size 20cm x 20cm x 25mm thick, as in floors etc,including 20 mm thick screed bed in cement mortar 1:6 and set & jointedin neat cement slurry and pointed with grey cement and pigments to match with the shade of tiles complete all as specified and directed. |
| 8 | Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 9 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges and keeping serviceable sheets in safe custody for reuse in the work complete as directed. |
| 10 | M & L for Rolled mild steel fo grade Fe 410-W (Gde-E- 250) quality-A as in roof trusses (framed),trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pices, cleat etc complete all as specified and directed. |
| 11 | S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer\"s instruction complete all as specified and directed. |
| 12 | S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer\"s instruction complete all as specified and directed. |
| 13 | M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed. |
| 14 | Demolition of brick work or stone / boulder masonry/ precast concrete block masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal ofdebris and rubbish complete all as directed by the Engr-in-Charge. |
| 15 | M & L for Pre-cast cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate),block masonry with solid blocks of size 300x200x200mm or 300x200x100mm, having compressive strength of not less than 100 Kg/Sq Cm (As per IS-2185) exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed. |
| 16 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish complete all as specified and directed |
| 17 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 18 | M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4,mixed with integral water proofing compoundwith weight of cement in top layer as per manufacturer\"s instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 19 | Supply only integral water proofing compound (ISI marked) complete all as specified and directed. |
| 20 | M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer complete all as specified and directed. |
| 21 | M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 22 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets/snap grid/frame work etc complete all as specified and directed. |
| 23 | S & F powder coated aluminium Anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestor E-board, HSPC, designer, pre-primed, self exposed, textured, water resistant, termite resistant, fire resistant for insulation board fixed to framecomplete all as specified and directed by the Engr-in-Charge. |
| 24 | Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed. |
| 25 | Taking down shutters of any description exc 2 Sqm each complete all as specified and directed. |
| 26 | S & F 35 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 27 | S & F Powder coated aluminium sections (minimum 50 micron) of approved colour as in door, window, ventilator frames, partitions with one or more rebates and door, windows shutters sliding/openable type/ventilator shutter including provision of necessary jointing cleats, glazing clips, neoprene rubber packing, powder coated aluminium snap beading, screws inclding provision of suitable size of powder coated aluminium fittings such as locking arangements, handles, stainless steel fiction hinges and tower bolts etc including fixing only glass panels/particle board panels/wire gauge/aluminium grill etc complete all as specified and directed. (Note : (i)The size of aluminium sections shall be all as specified in relevant IS Code and MES Schedule Part-I (ii) Glass panels/ Partricle Board panels/ Wire gauge etc shall be measured paid seperately as supply only rates under respective items here-in-below). |
| 28 | S & F 100 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed. |
| 29 | S & F 150 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 30 | S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 31 | S & F 300 mm Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sectionsor cast aluminium alloy, length of bolt complete all as specified and directed. |
| 32 | Supply only 5.5 mm thick, sheet glass,ordinary quality and glazing withbeading for door/window etc in square exceeding 0.5 Sqmin each pane complete all as specified and directed.(Note: The cost of fixing and glazing beads included with the unti quoted rate of respective shutter) |
| 33 | Supply onlyStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed.(Note: The cost of fixing included with the unti quoted rate of respective shutter) |
| 34 | S & F in repairStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed. |
| 35 | M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 36 | M & L for Preparation of oldpainted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed. |
| 37 | M & L for Preparation of old treated asbestos cement building board surfaces of walls etc of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 38 | S & F in repairs 24 mm outer dia, stainless steel, curtain rail/rod, heavy duty, minimum 1mm wall thick including brackets, side holder and rings etc fixed to /wall etc complete all as specified and directed.(Note: (i) Stainless steel decorative finials and stainless steel brackets shall be provided for each leangth of curtain rail/rod and cost of the same shall deemed to be included in the unit quoated rate. (ii) Length of of curtain rail/rod shall only be measured for payments) |
| 39 | Surface dressing n.exc 15 cm deep as in soft/loose soil complete all as specified and directed. |
| 40 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depthfor foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 41 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. |
| 42 | Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting pointcomplete all as specified and directed. |
| 43 | Excavating in post holes (or similar holes) each n. exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface in soft/loose soil complete all as specified anddirected. |
| 44 | M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed. |
| 45 | M & L for use & waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter complete all asspecified and directed. |
| 46 | M & L for use & waste Formwork to sides of pillars, posts, struts, piers, columns and stanchionsfor flat rough finished surfaces of concrete complete all as specified anddirected. |
| 47 | M & L for use & waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etcetc complete all as specified anddirected. |
| 48 | M & L for use & waste Form work to chajjas, troughs and similar items including edges flat for rough finished surfaces of concretecomplete all as specified and directed. |
| 49 | M & Lfor Reinforced Cement Concrete 1:1.5:3, type A-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in foundations including rafts, footings and mass concrete, etc complete all as specified and directed. (Note: Reinforcement will be measured and paid seperately) |
| 50 | M & L for Reinforced Cement Concrete1:1.5:3, Type A-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in columns, pillars, posts and struts complete all as specified and directed. (Note :Reinforcement will be measured & paid seperately) |
| 51 | M & L Reinforced Cement Concrete1:1.5:3, Type A-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed.(Note :Reinforcement will be measured & paid seperately) |
| 52 | M & L Reinforced Cement Concrete1:1.5:3, Type A-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in chajjas etc complete all as specified and directed.(Note :Reinforcement will be measured & paid seperately) |
| 53 | S & F high strength TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 54 | S & F high strength Mild steel TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed. |
| 55 | M & L for plain Cement Concrete1:3:6, type C-2 (using 40 mm graded stone aggregate) as in post, walls, retaining walls, ballast walls and the likes any thickness, above top of footings including attached pilasters and buttreses complete all as specified and directed. |
| 56 | S & F MS steel work in tubular trusses including special shapedwasher etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as speicfied and directed. |
| 57 | S & F Rolled mild steel in Plates (plain or chequered) channels fo grade Fe 410-W (Gde-E- 250) quality-A, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as speicfied and directed. |
| 58 | S & F Mild steel screw bolts of 16 to 20 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5cm and n.exc 30cm long complete all as specified and directed. |
| 59 | M & L for Sand filling under floors or in foundations including spreading, levelling, watering and consolidation complete all as specified and directed. |
| 60 | M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 61 | M & L for 100 mm thick, plain cement concrete 1:4:8,type D-2 (using 40 mm graded stone aggregate)as in sub-base of flooring, etc complete all as specified and directed. |
| 62 | M & L for Machine cut kota stone slab flooring 18 to 20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing over and including 15 mm thick, screed bed in cement mortar 1:6 complete all as specified and directed. |
| 63 | M & L for Machine cut kota stone slab, 18 to 20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing over and including 10 mm thick, screed bed in cement mortar 1:4 as in vertical surfaces as skirting/dado etc complete all as specified and directed. |
| 64 | M & L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed. |
| 65 | M & L for Reinforced Cement Concrete1:1.5:3, Type A-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, shelves etc complete all as specified anddirected.(Note :Reinforcement will be measured & paid seperately) |
| 66 | M & L for 18 to 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 67 | M & L for 40 mm thick, plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in floors laid in alternate bays and finishing the surfaces even & smooth with using extra cementcomplete all as specified and directed. |
| 68 | S & F 3 mm thick, 38mm wide glass dividing strips and inserted in position to conform to design complete all as specified and directed. |
| 69 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed. |
| 70 | M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer and over one or more coats of wall care putty to a smooth surface complete all as specified and directed. |
| 71 | M & L for Mild steelFramed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-290 (Gde E-165) complete all as specified and directed. |
| 72 | M & L for Mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 73 | S & F Well seasoned 2nd class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed. |
| 74 | M & L for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etcincluding necessary form work complete all as specified and directed. |
| 75 | S & F 30 mm thick, Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 76 | S & F Floor door stopper of aluminium alloy body and tongue, anodised, 150 mm overall length of cover plate with hard drawn steel spring, fixed in floorcomplete all as specified and directed. |
| 77 | S & F Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sectionsor cast aluminium alloy, length of bolt of 250 mm complete all as specified and directed. |
| 78 | S & F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified anddirected. |
| 79 | S & F 3 mm thick, sheet glass,ordinary quality and glazing with oil puttyin square not exceeding 0.5 Sqm in each pane complete all as specified and as directed. |
| 80 | S & FStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed. |
| 81 | M & L for 40 mm thick, Cement Concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) Damp proof course to horizontal or vertical surfaces including necessary form workmixed with water proofing compound as per manufacturer\"s instructions complete all as specified and directed. (Note: Water proofing compound shall be measured and paid seperately) |
| 82 | M & L for Antitermite treatment by treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 83 | M & L for Antitermite treatment by treatingthe backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed. |
| 84 | M & L for Antitermite treatment by treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed. |
| 85 | M & L for Antitermite treatment by treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 86 | M & L for Antitermite treatment by treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed. |
| 87 | M & L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment complete all as specified and directed. |
| 88 | M & L for Plain cement concrete 1:3:6, type C-1, (using 20 mm graded stone aggregate) as inroof kerb or mud stop, benching etc rounded or chamfered on edges incuding necessary form works etc complete all as specified and directed. |
| 89 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 90 | Taking down unserviceable main switches, DBs, bus bars chambers, VTPN etc any capacity including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified anddirected. |
| 91 | M & L for Point wiring for one light/exhaust fan/fan point/call bellcontrolled by one way switch with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC casing capping (ISI marked) (aprox size 20/25/40mm width) surface type with all fittings/fixtures such as Tee, Bend, elbow, socketr, shaddle etc including 1.5mm thick MS sunken/terminal box including 3mm thick backelite sheet cover for fixing flush type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductorcable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) |
| 92 | All as per item No. 91 above but for One 3/5 pin socket outlet 6 amps pointon same boardcomplete ditto |
| 93 | All as per item No. 91 above but forOne 3/5 pin socket outlet 6 amps on independent board complete ditto |
| 94 | All as per item No. 91 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistrandedFRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cableFRLS (ISI marked) as earth lead complete ditto |
| 95 | S & F switch piano Flush type, single pole one way 6 Amp 240 volts, complete all as specified and as directed. |
| 96 | S & F Socket outlet 2 in 1, 3 pin, 6 Amps, flush type complete all as specified and as directed. |
| 97 | S & F Switch socket combination 2 in 1, 6 Amp, flush type complete all as specified and as directed. |
| 98 | S & F Switch socket combination 2 in1, 3 pin, 6 and 16Amp, flush type, universal complete all as specified and as directed. |
| 99 | S & F Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed. |
| 100 | S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed. |
| 101 | S & F LED tube light fittings, retro bar professional WH 5700K to 6000K, 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specifiedand directed. (Make: Havell\"s Cat No. LUMILINENEOBS20WLED840SPCSSIND or equivelant of make as per list of manufacturer) |
| 102 | S & F 2ftx2ft recessed mounting, LED panel light fittings, 36 Watt with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specifiedand directed. (Make: Havell\"s Cat No. VENUSNEOHE2X2R36WLED840PIRSENSOR or equivelant of make as per list of manufacturer) |
| 103 | S & F LED Bulk Head, 10 Watt, IP 65 rated, compact design, PC Co extruded with high energy saving with all accessories and connecting up including lamp complete all as specifiedand directed. (Make: Crompton Cat No. TIS-304-10-57-SL-DP-NWH or equivelant of make as per list of manufacturer) |
| 104 | S & F Lamp Holder, PVC/ Polycarbonate type with backplate suitable for batten fitting complete all as specified and as directed. |
| 105 | S & F LED Bulb, 15 Watts, B-22 Lumen ≥ 1200, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specifiedand directed. |
| 106 | Taking down and dismantling the ceiling fan 1200 / 1400 mm sweep of any capacity from existing position and removing its allied spare parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable minor parts and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, spilt pins, screws, nuts and spring washers etc and applying one coat of spray painting complete including provn flexible copper conductor cable of 24 / 0.20mm of required length with necessary connector (for blade / body) as required complete all as specified and directed. (Note : (i) Cost of minor spare parts shall deemed to be included in quoted rate. (ii) The cleaning, servicing, oiling and lubricating of fans has to be carried at site itself and to be completed withing one hour unless re-winding is required. ). |
| 107 | S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Havell\"s cat part No. DHDPSHODRW08 or equivalent make as per List of Manufacturer\"s) |
| 108 | S & F MCB SPN 6-32A Amps, 240 Volts,10KA, C Curve complete all as specified and as directed Havell\"s cat part No. DHMGCSNF006-032 or equivalent make as per List of Manufacturer\"s) |
| 109 | S & F MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve,complete all as specified and as directed (Make: Havell\"s cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer\"s) |
| 110 | M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia TMT bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. |
| 111 | S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete all as specified and directed. |
| 112 | S & F in repairs PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 150 mm and 50 mm deep complete all as specified and directed. |
| 113 | S & F 1100 volts grade, heavy duty cablePVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathedin service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, 16 Sqmm 2 core solid conductor including taking down existing one complete all as specified and directed. |
| 114 | S & F in repair House service bracket (hook type) complete with 3.0m long GI pipe 40mm dia, Medium Grade, two nos. 90 degree bends, M.S. hook and stay or guy complete all as specified and directed. |
| 115 | M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type includingmetal GI boxes of suitable module including modular white cover plate with frame of suitable module for fixing modular type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductorcable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed,for one light/exhaust fan/fan point/call bellcontrolled by one way switch.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 116 | All as per item No. 115 above but for One 3/5 pin socket outlet 6 amps pointon same boardcomplete ditto |
| 117 | All as per item No. 115 above but forOne 3/5 pin socket outlet 6 amps on independent board complete ditto |
| 118 | All as per item No. 115 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistrandedFRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cableFRLS (ISI marked) as earth lead complete ditto |
| 119 | S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed. |
| 120 | S & F Modular socket outlet6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed. |
| 121 | S & F madular Switch socket Combination 16A, 6 pin, 3 module complete all as specified and directed |
| 122 | S & F stepped type modular fan regulator ,100/120 W 1/ 2 module complete all as specified and as directed. |
| 123 | M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface PVC casing capping of suitable size with all accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cableas earth continuity conductorcomplete all as specified and as directed.(Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of casin cappingshall be measured as one length) |
| 124 | S & F LED Bulb, 9 Watts, B-22 Lumen ≥ 900, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 80 Ra,IP 20 rated, overmoulded plastic housing, polycarbonate diffuser, 4KV surge Protection with over voltage protection withstand upto 440 V (for 10 Minute) with open and short circuit protections as per IS: 16102 complete all as specifiedand directed. |
| 125 | Supply, fix, installation and commissioning BLDC ceiling fan of less noise, silent operation, speed controlable by regulator, light colour, conforming to IS-374-2019, 1200 mm sweep, 230 Volts, BEE 5 Star rating, any Govt recognised Lab tested, power factor >0.94 Wattage and not more than 35 Watt, air delivery not less than 215cfm alongwith electronic type regulator and all accessories such as down rod etc and connecting up with 1.5 Sqmm, PVC insulated, multistranded copper conductor cables from ceiling rose to fan complete all as specified and directed. (Note: Ceiling fan should have minimum 3 years manufacturer\"s warranty)(Make : USHA/Havell\"s/Bajaj/CG) |
| 126 | S & F Exhaust fan, 300 mm sweep, heavy duty, metal body 1400 RPM, AC, single phase, complete with all accessories and louver and electric connection including making necessary holes in walls complete all as specified and directed (Make : Havells, Model : Ventil Air DS or equivelant of make as per List of Manufacturer\"s as approved) |
| 127 | S & F Distribution Board, SPN 4 Way, 240V, Double door with IP 43 protection complete all as specified and as directed. (Make: Havell\"s cat part No. DHDNSHODAW04 or equivalent make as per List of Manufacturer\"s) |
| 128 | S & F MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell\"s cat part No. DHMGCSNF040-63 or equivalent make as per List of Manufacturer\"s) |
| 129 | M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion complete all as specified and as directed by the Engineer-in-Charge. |