}

Tender For Rate Contract For Civil Work Under Dtc-Jica Scheme At Dcs, jaipur-Rajasthan

Jaipur Zila Dugdh Utpadak Sahakari Sangh Limited has published Tender For Rate Contract For Civil Work Under Dtc-Jica Scheme At Dcs. Submission Date for this Tender is 02-07-2025. Earth Work Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

49644003
Tender For Rate Contract For Civil Work Under Dtc-Jica Scheme At Dcs
Tender
Indian
Rajasthan
Jaipur
02-07-2025

Tender Documents

Tender Details

Tender For Rate Contract For Civil Work Under Dtc-Jica Scheme At Dcs- 1 ROOM CIVIL (G-SCHEDULE) 2 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter All kinds of soils 3 Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth , consolidatingeach deposited layer by ramming and watering including lead upto 50Mtr. and lift upto 1.5Mtr. 4 Soil Filling From Outside Soil 5 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost ofcentering and shuttering - All work up to plinth level. 6 M10 grade Nominal Mix1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). 7 REINFORCEMENT CEMENT CONCRETE 8 Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost ofplastizers( if required) excluding the cost of centering, shuttering and reinforcement.M20 grade Nominal Mix / Design Mix 9 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M20 grade Nominal Mix / Design Mix 10 ADD EXTRA FOR PROVIDING RICHER MIXES RESPECTIVELY AT ALL FLOOR LEVELS 11 Providing M-25 grade concrete by using cement as per codal provision instead of M-20 grade design mix. 12 Providing and fixing up to floor five level pre cast cement concrete string or lacing courses, copings, bed plates, anchor blocks, windows sills, shelves, louvers steps, staircases, etc. including carriage, hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surface, including all T & P, curing etc. complete: M15 grade Nominal Mix1: 2: 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size). 13 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. 14 Columns, pillars, posts and struts etc. 15 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.(Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) 16 Thermo-mechanically Treated bars (Conforming of relevent IS code) 17 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : 18 Cement mortar 1 : 6 (1 cement : 6 coarse sand) 19 Half brick masonry in foundation & plinth using bricks of designation 75 20 Cement mortar 1 : 3 (1 cement : 3 coarse sand) 21 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: 22 Cement Mortar 1:6 ( 1-Cement : 6-Sand). 23 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : : 24 25 MM THICK 25 12 MM THICK 26 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 27 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: 28 Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. 29 Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provisionNEW WORK 30 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 31 40mmthickwith20mmthicknominalsizeaggregate. 32 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 33 For area of each slab from 901 to 2000 Sq.Cm : 34 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete 35 For area of each slab upto 2001Sqcm 36 Extra for providing edge moulding to 15-18mm thick marble/Granite /Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 37 GRANITE/KOTA STONE WORK 38 FULL EDGE MOULDING 39 Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : 40 WINDOWS FIXED 41 Supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design & IS 6248- 1979. (Clear openable area to be measured for payment). 42 Structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. 43 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 44 0.63 mm thick with zinc coating not less than 275 gm/m2 45 P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor : 46 Fire clay glazed kitchen sink (I.S 771-1985Marked) size 600 x 450 x 250mm. 47 PLUMBING WORK :SANITARY FIXTURES 48 Supply and Fixing CP Bottle Trap40mm / 32mm dia complete including cuttingandmaking goodthe walls wherever required. 49 32 MM DIA 50 Supply and Fixing 15mm C.P brass bib tap with C.P brass threaded flange complete, including cutting and making good the walls wherever required. 51 SHORT BODY 52 LONG BODY 53 Providing and fixing white vitreousKITCHEN sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P brass waste and 40mm C.P. brass trap with necessary fittings complete including painting of fittings and brackets, cutting and making good the wall Size 600x450x200mm (Shera model no.-S6010102 OR Equalent) 54 Supply and Fixing 15mm C.P.brass angle valve with C.P copper connecting pipe 375mm long and nuts, washer with C.P. brass flange complete, including cutting and making good the walls, wherever required. 55 SOIL, WASTE AND VENT PIPES & FITTINGS 56 Providing, fixing & testing uPVC SWR pipes confirming to IS 13592 (Type B) alongwith all required fittings like tees, bends, crosses with or without access doors jointed with approved solvent cement as per manufacturers recommendations, fixed to walls and ceilings with clamps complete including cutting and making good the floors and walls where required complete of outer diameter. 57 75 MM OUTER DIA 58 110 MM OUTER DIA 59 Providing, fixing & testing uPVC pipes, conforming to IS 4985 class 3 (6 kg/cm2) including injection moulded fittings, jointing with solvent cement, cutting and making good the floors and walls and jointingto trap/waste pipe, complete of outer dia. 60 40 MM DIA OD 61 Providing, fixing and testing of uPVC SWR P or S trap including jointing with solvent cement and making good the walls, floors etc., complete of nominal size.(110mmx110mm) 62 Providing and fixing 125 mm dia, 3 mm thick stainless steel grating with frame for floor traps or drains of required pattern including cutting and making good the floors complete. 63 RAIN WATER PIPES & FITTINGS 64 Providing and fixing uPVC rain water pipes of6kg/cm2 conforming to IS: 4985 including all fittings withor without access i.e bends, junctions, cowls,offsets,etc., and jointing with solvent cementincluding cutting holes inwalls and floors ,wherever required and making good the same, complete as directed by the Engineer-in-Charge. 65 90 MM OUTER DIA 66 WATER SUPPLY (INTERNAL) 67 Providing, fixing, jointing and testing in position flow guard CTS-SDR 11, CPVC(chlorinated poly vinyl chloride) conforming to IS 15778-2007, ASTM D2846, UV resistant, suitable for hot & cold water supply in concealed works complete with all plugs, clamps including transition fittings between CPVC pipe including jointing the pipe and fittings by flow guard solvent cement as per ASTM F 493 and by Teflon tape on threaded ends including cutting chases and making good the walls and properly clamped . All termination points for installation of faucets shall have brass terminal fittings complete as required by engineer in charge and manufactures specification for proper completion of work. 68 15 MM DIA 69 20 MM DIA 70 Providing and fixing brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 and spindle AISI 410) with setting and gland of superior quality having minimum working pressure of 10 kg/cm2. 71 20 MM DIA 72 ELECTRICAL WORKPOINT WIRING AND SUBMAIN WIRING 73 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 74 SHORT POINT (UP TO 3 MTR) 75 MEDIUM POINT (UP TO 6 MTR) 76 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. 77 3x 1.5 sq.mm (For Extra Point Wiring) 78 2 x 2.5 sq. mm. + 1x1.5sqmm (For Lightcircuit) 79 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. (For Power & AC Circuit) 80 2 x 6.0 sq.mm (For Sub Mains) 81 1 x 4.0 sq.mm (For Earthing) 82 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 83 16 A ONE WAY SWITCH WITH LED INDICATOR 84 25 AMP 2 MODULE SWITCH WITH LED INDICATOR 85 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 86 6/16 A SHUTTERED SOCKET 87 25 AMP 2 MODULE SOCKET 88 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. 89 5 STEP FAN REGULATOR 2 MODULE 360 DEGREE ROTATING 90 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. 91 BLANKING PLATE 92 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. 93 25 MM 94 MCBS & DISTRIBUTION BOARDS 95 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. 96 SINGLE POLE MCB (WITH B/C CURVE TRIPPING CHARACTERSTICS) 97 6 A TO 32 A RATING 98 Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protectionwith ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA,provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. 99 TWO POLE 100/300M A SENSITIVITY 100 40 A RATING 101 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. 102 METAL DOOR (SINGLE PHASE) IK-09 AND IP-43 WITH METAL END BOX 103 6 WAY (6+2) 104 FANS & LIGHTINGS 105 Providing & Fixing of1200 mm sweepBLDC technologypower savingceilingfanwhich can withstand on votage fluctuationsfrom 140 volts to 240 volts ,power factor not less then 0.9 , service value (CMM/W) minimun 6.85 , air delivery minimun 220 CMM, speed minimum 330 RPM ( tolerance as per IS:374 2019 ) THD less then 10%and complete with down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steelpipe up to 80 cm, cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 WITHOUT REMOTE 107 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 108 300 MM SWEEP (900/1400 RPM) 109 P & F of Wall cowl with Bird Screen Suitable for Outside Wall of Exhaust Fan Openingof following size and made out from 24 SWG GI sheet as per instructions of Engineer in chargeincluding fixing with suitable fasteners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 110 SUITABLE FOR 300 MM SWEEP EXHAUST FAN 111 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 112 600mm , Min. Lumens output 1800 lmLED Tube rod with Polycarbonate Housing 113 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing

Key Value

Document Fees
INR 2500 /-
EMD
INR 2000000.0 /-
Tender Value
INR 10 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail