| Sl. No. | Item Description |
| 1 | Sub-Head : Earth Work |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. |
| 3 | a) All kinds of soil |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50 m and lift up to 1.5m, as directed by Engineer-in-Charge. |
| 5 | a) Ordinary rock |
| 6 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 7 | a) All kinds of soil. |
| 8 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50m. |
| 9 | a) Ordinary rock |
| 10 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : |
| 11 | a)All kinds of soil |
| 12 | (i) Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 13 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 14 | Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. |
| 15 | a) All kinds of soil. |
| 16 | Sub-Head : Concrete Work |
| 17 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 18 | a) 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 19 | b) 1:5:10 (1 cement : 5 coarse sand(zone-III) : 10 graded stone aggregate 40 mm nominal size) |
| 20 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing : |
| 21 | a) 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 22 | Providing and laying in position plum concrete with hard stone boulders in retaining walls etc up to all height and level, in required size and shape etc. with cement concrete of mix 1:4:8 (1 Cement : 4 Coarse sand : 8 Graded stone aggregate 40 mm nominal size) using 30 % hard stone boulders of size 150 mm to 300 mm, excluding cost centring and shuttering all complete as per the direction of Engineer-in-charge. |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 24 | a) Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.. |
| 25 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling and dressing and finishing the top smooth. |
| 26 | Sub-Head : Reinforced Cement Concrete |
| 27 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 28 | a) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 29 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 30 | a) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 31 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 32 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 33 | a) Foundations, footings, bases of columns, etc. for mass concrete |
| 34 | b) Suspended floors, roofs, landings, balconies and access platform |
| 35 | c) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 36 | d) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 37 | c) Stairs, (excluding landings) except spiral-staircases |
| 38 | d) Weather shade, Chajjas, corbels etc., including edges |
| 39 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete below and above plinth level. |
| 40 | a) Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 41 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). |
| 42 | Sub-Head : Masonry Work |
| 43 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 44 | a) Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 45 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 46 | a) Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 47 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 48 | a) Cement mortar 1:4 (1 cement :4 coarse sand) |
| 49 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.ird course of half brick masonry. |
| 50 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 51 | Providing and laying broken autoclaved aerated cement (AAC) blocks and/or bats (light weight, having density 550-650 kg/m3) of nominal size 25mm to 65mm in the sunken portion of toilets upto floor five level all complete as per the direction of Engineer-in-charge. |
| 52 | Sub-Head - Stone Work : |
| 53 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level with : |
| 54 | a) Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 55 | Supplying & Filling with stone boulders of size 150 to 300 mm in plum concrete of retaining wall complete as per the direction of the Engineer-in-charge. ( Note :- 30% deduction shall be made for voids in boulder filling) |
| 56 | Providing and fixing 75 mm dia Rigid PVC pipe (working pressure 4kg./sqcm.) conforming to IS : 13592 type A in retaining walls for use as weep holes, laid to required slope complete as per the directions of the Engineer-in-charge. |
| 57 | Sub-Head : Cladding Work |
| 58 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 59 | a) Granite stone slab colour black, Cherry/Ruby red |
| 60 | (i) Area of slab over 0.50 sqm |
| 61 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 62 | Sub-Head : Woodand P.V.C. Work |
| 63 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia. & length (hold fast lugs or dash fastener shall be paid for separately). |
| 64 | a) Second class teak wood |
| 65 | Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick (weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 66 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 67 | a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 68 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : |
| 69 | a) 35 mm thick shutters. |
| 70 | (i) with ISI marked M.S. pressed butt hinges bright finished of required size - Second class Deodar wood |
| 71 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : |
| 72 | a) 2nd class Deodar wood |
| 73 | (i)50 x 20 mm |
| 74 | Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete : |
| 75 | a) 25 mm dia. |
| 76 | Providing M.S. Piano hinges ISI marked IS : 3818 finished with nickel plating and fixing with necessary screws etc., complete. |
| 77 | a) Overall width 35 mm. |
| 78 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete. |
| 79 | Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : |
| 80 | a) 150 mm |
| 81 | Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. |
| 82 | a) Size 50 mm |
| 83 | Providing and fixing Stainless steel sliding door boltstransparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 84 | a) 300x16 mm |
| 85 | b) 250x16 mm |
| 86 | Providing and fixing SStower bolts transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 87 | a) 250x10 mm |
| 88 | b) 200x10mm |
| 89 | Providing and fixing stainless steel handlestransparent or dyed to required colour or shade with necessary screws etc. complete : |
| 90 | a) 125 mm |
| 91 | b) 100 mm |
| 92 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 93 | a) Twin rubber stopper |
| 94 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 95 | a) 1.0 mm thick. |
| 96 | Providing & Fixinglaminated sheet of in white / ivory shade of Century/Greenply/Merino make, inside of cupboard etc. with adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 97 | a)0.8 mm thick. |
| 98 | Providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineer-in-charge. |
| 99 | Providing and fixing MS powder coated set of five pegs (Hooks) of approved quality with MS screws all complete as per direction of the Engineer-in-charge . |
| 100 | P/F PVC rubber Silencer on the rear side of door shutter to avoid collision between wall and door shutter as per directions of Engineer in Charge. |
| 101 | Providing and fixing BWP Ply board conforming to IS: 710 of of Merriono/ Greenply/ Century/Archid/Kitply , bonded with phenolformaldehyde synthetic resin in cupboards, shelves, shutters with necessary screws, nails and adhesive etc. all complete as per the direction of Engineer-in-charge |
| 102 | a) 18 mm thick |
| 103 | Providing and fixing 6mm thick BWP grade commercial ply of Merriono/ Greenply/Century/ Archid/ Kitply , bonded with phenolformaldehyde synthetic resin in backing ofcupboards, shelves, shutters with necessary screws, nails and adhesive etc. all complete as per the direction of Engineer-in-charge |
| 104 | a) 6 mm thick |
| 105 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. |
| 106 | a) Second class teak wood |
| 107 | (i) 30 mm thick |
| 108 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 109 | a) Fixed to openings /wooden frames with rawl plugs screws etc. |
| 110 | Sub-Head : Steel Work |
| 111 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 112 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 113 | a) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 114 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 115 | Sub-Head : Flooring |
| 116 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 117 | Providing and laying full body vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc. complete. |
| 118 | a) Size of Tile 600x600 mm |
| 119 | Providing and laying full body Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments |
| 120 | a) Size of Tile 600x600 mm |
| 121 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardener and 0.20 kg of resin per kg), including filling/grouting and finishing complete as per direction of Engineer-in-charge. |
| 122 | a) Size of Tile 600x600 mm |
| 123 | Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles |
| 124 | Providing and layingGVTvitrified floor tiles of approvedin smooth finish Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, in all colours & shade in wall liningover 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including using PVC spacer 2 to 3 mm thick and after removing the spacers,the joints shall be filled using epoxy grout mix of 0.7 kg of organic coated filler of desired shade , 0.1 Kg of hardner and 0.2 kg of resin per kg of grout and finishing all complete as per direction of E-In-Charge. |
| 125 | a) Size of Tile1200x600 mm |
| 126 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 127 | a) Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red |
| 128 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 129 | a) Glazed Vitrified tiles Matt/Antiskid finish of size |
| 130 | i) Size of Tile 600 x 600 mm |
| 131 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. |
| 132 | a) Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent |
| 133 | Sub-Head : Roofing |
| 134 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 135 | (i) Single socketed pipes. |
| 136 | a) 110 mm diameter |
| 137 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 138 | a) Coupler |
| 139 | (i) 110mm |
| 140 | b) Bend 87.5° |
| 141 | (i) 110 mm bend |
| 142 | C) Shoe (Plain) |
| 143 | (i) 110 mm Shoe |
| 144 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 145 | a) 110 mm |
| 146 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 147 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 148 | a) Ridges plain (500 - 600mm) |
| 149 | b) Flashings/ Aprons.( Upto 600 mm) |
| 150 | C) Barge board (Upto 300 mm) |
| 151 | d) Gutter (600 mm over all girth) |
| 152 | Sub-Head : Finishing |
| 153 | 12 mm cement plaster of mix : |
| 154 | a) 1:6 (1 cement: 6 coarse sand) |
| 155 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 156 | a) 1:6 (1 cement: 6 coarse sand) |
| 157 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade. |
| 158 | a) New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 159 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 160 | a) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm). |
| 161 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 162 | a) Two or more coats on new work. |
| 163 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 164 | a) Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 165 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 166 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 167 | Providing & fixing G.I. chicken wire mesh of nominal size upto 20mm having 24 gauge thick with G.I. nails etc. to wall surface of dissmilar material viz RCC and brick work etc.all complete. |
| 168 | Sub-Head : Sanitary Installations |
| 169 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : |
| 170 | a) W.C. pan with ISI marked white solid plastic seat and lid |
| 171 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 172 | a) White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 173 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 174 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 175 | a) Kitchen sink with drain board |
| 176 | (i) 510x1040 mm bowl depth 250 mm. |
| 177 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 178 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 179 | a) Flexible pipe |
| 180 | (i) 32 mm dia |
| 181 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 182 | Providing and fixing high pressure upvc spigot and socket Integrated Rubber Ring (IRR) waste and ventilating pipes conforming to IS 13592 Type B including jointing with seal ring (IRR) leaving 10mm gap for thermal expansion |
| 183 | a) 110mm Dia Single Socketed Pipes |
| 184 | Providing and fixingupvc moulded IRR fittings forwaste and ventilating pipesincluding jointing with seal ring(IRR) leaving 10mm gap for thermal expansion:- |
| 185 | a) Bend 87.5 degree: 110 mm bend. |
| 186 | b) Door Bend 87.5 degree: 110 mm door bend. |
| 187 | C)Single tee without door: 110 x 110 x 110 mm. |
| 188 | d) Single tee with door: 110 x 110 x 110 mm. |
| 189 | e) Coupler : 110mm |
| 190 | f) Vent Cowl : 110mm |
| 191 | g) P-Trap 125x110mm |
| 192 | h) Nahani Trap 110x110mm |
| 193 | Providing and fixing hinged stainless steel jali (grating) with or without hole for waste pipe for floor/Nahni trap. |
| 194 | a)100 mm dia |
| 195 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 196 | a) 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 197 | Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour. Weighing not less than 300 gms. |
| 198 | Sub-Head : Water Supply |
| 199 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall. |
| 200 | 15 mm dia. nominal bore |
| 201 | 20 mm dia. nominal bore |
| 202 | 25 mm dia. nominal bore |
| 203 | 32 mm dia. nominal bore |
| 204 | 40 mm dia. nominal bore |
| 205 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anticorrosive bitumastic paint, cutting chases and making good the wall: |
| 206 | a) 15 mm dia. nominal bore |
| 207 | b) 20 mm dia. nominal bore |
| 208 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. : External work |
| 209 | a) 25 mm dia. nominal bore |
| 210 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 211 | a) 25 to 40 mm nominal bore |
| 212 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 213 | a) 25 mm nominal bore |
| 214 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 215 | a) 15 mm nominal bore |
| 216 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 217 | a) 45 cm length |
| 218 | (i) 15 mm nominal bore |
| 219 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) |
| 220 | a) 15 mm nominal bore |
| 221 | b) 20 mm nominal bore |
| 222 | c) 25 mm nominal bore |
| 223 | d) 32 mm nominal |
| 224 | e) 40 mm nominal bore |
| 225 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 226 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931: |
| 227 | a) 15 mm nominal bore. |
| 228 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 229 | a) 15 mm nominal bore. |
| 230 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 231 | a) 15 mm nominal bore. |
| 232 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 : |
| 233 | a) 15 mm nominal bore |
| 234 | Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 235 | Sub-Head : Drainage |
| 236 | Providing and layinghigh pressure upvc spigot and socket Integrated Rubber Ring (IRR)pipes conforming to IS 13592 Type B including jointing with seal ring (IRR) leaving 10mm gap for thermal expansion |
| 237 | a) 110 mm Dia Single Socketed Pipes |
| 238 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round upvc pipes including bed concrete as per standard design: |
| 239 | a) 110 mm diameter upvc pipe |
| 240 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : |
| 241 | a) 100x100 mm size P type |
| 242 | (i) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 243 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement |
| 244 | and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 245 | a) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 246 | (i) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 247 | Extra for depth for manholes |
| 248 | a) Size 90x80 cm |
| 249 | (i) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 250 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : |
| 251 | a) With 20x20 mm square bar |
| 252 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality |
| 253 | a) L D - 2.5 |
| 254 | (i) Rectangular shape 600x450 mm internal dimensions |
| 255 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 256 | a)With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 257 | Sub-Head : Water Proofing |
| 258 | Providing and laying water proofing treatment to vertical and horizontalsurfaces of depressed portions of W.C., kitchen and the like consistingof: |
| 259 | (i)Ist course of applying cement slurry @ 4.4 kg/sqm mixed withwater proofing compound conforming to IS 2645 in recommendedproportions including rounding off junction of vertical andhorizontal surface. |
| 260 | (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarsesand) mixed with water proofing compound in recommendedproportion including rounding off junction of vertical and horizontalsurface. |
| 261 | (iii) IIIrd course of applying blown or residual bitumen applied hot at1.7 kg. per sqm of area. |
| 262 | (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at jointsof PVC sheet should be 100 mm wide and pasted to each otherwith bitumen @ 1.7 kg/sqm). |
| 263 | Electrical Work |
| 264 | SUB HEAD-I (Wiring) |
| 265 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 266 | a) Group A |
| 267 | b) Group C |
| 268 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 269 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 270 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 271 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 272 | a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 273 | b) 4 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire |
| 274 | C)2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 275 | d) 4 X 10 sq. mm + 2 X 6sq. mm earth wire |
| 276 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 277 | a) 20mm |
| 278 | b) 25mm |
| 279 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. |
| 280 | a) 3x1.5 sq. mm |
| 281 | b) 4x1.5 sq. mm |
| 282 | C) 5x1.5 sq. mm |
| 283 | d) 6x1.5 sq. mm |
| 284 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 285 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 286 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. of 3 pin 5/6 A modular socket outlet and2 nos. of5/6 A modular switch, connections etc. as required. |
| 287 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 288 | a) 5/6 amps switch |
| 289 | b) 15/16 amps switch |
| 290 | C)3 pin 5/6 amp socket outlet |
| 291 | d) 6 pin 15/16 amp socket outlet |
| 292 | e) TV antenna socket outlet |
| 293 | f) RJ-45 Jack with Cat 6 One Module |
| 294 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 295 | a) 1 or 2 Module (75mmX75mm) |
| 296 | b) 4 Module (125mmX75mm) |
| 297 | C) 8 Module (125mmX125mm) |
| 298 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 299 | a) 1 run of cable |
| 300 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 301 | a) 1 run of cable |
| 302 | SUB HEAD-II (Distribution System) |
| 303 | Supplying and fixing following way, vertical type TPN, sheet steel, MCB distribution board, 415 volts having provision for MCCB as incomer, on surface/ recess, complete with metal door, tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCCB/ RCCB/ Isolator) |
| 304 | b) 4 WAY (4+4+4) Double Door ( Make L&T, Model:PHV304DYM ) |
| 305 | Three pole, 100A MCCB with variable Thermal-Magnetic Release, (Release range upto 80-100 Amp), breaking capacity 18KA at 415V with Neutral Link. (M/s L&T DU100D or equivalent similar superior make)(Ics = 100% Icu) |
| 306 | Supplying and fixing following way, horizontal type SPN / TPN, sheet steel, MCB distribution board, 240/ 415 volts, on surface/ recess, complete with metal door, tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator) |
| 307 | a) 12 Way SPNDouble Door ( Make-Havells Metalica Model-DHDNSHODAW12) |
| 308 | b) 4 Way TPN (8+12) Double Door ( Make- Havells Model-DHDNTHCDRW48 ) |
| 309 | Supplying and fixing following rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 310 | a) 5 amps to 32 amps, 240 volts Single pole. |
| 311 | b) Double Pole 40A |
| 312 | C) 63 A Four Pole |
| 313 | d) 63 A TP MCB |
| 314 | S/F Following rating MCB power protected unit suitable for operation on 230V single phase AC supply complete with all accessories i/c making interconnection etc as required. |
| 315 | a) 20 A |
| 316 | Supplying and fixing 25 Amps., double pole, (single phase and neutral), 230 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 317 | Supplying and fixing 63 Amps., four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 318 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 319 | Supplying and fixing Adaptor Box(s) fabricated out of 16 SWG M.S. sheet complete with cutting, welding, painting, sign writing etc. all as required. |
| 320 | SH-III ( Earthing ) |
| 321 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories,and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 322 | Supplying and laying 25 mm X 5 mm G.I strip on surface or in recess etc as required. |
| 323 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc.as reqd |