Tender For Ei Work, Electrical Repair And Renovation Work Of The Existing Blood Centre Under Malda Medical College And Hospital, Malda. (Electrical Work). - 1 Part - I (E.I. Work) 2 A) Distribution Boards 3 Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, concealed in wall as per GS. (Make - Legrand/ L&T/ Schneider). 4 i) 6 Way upto 160Amp MCCB incommer 5 ii) 4 Way upto 160Amp MCCB incommer 6 Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS. (Make - Legrand/ L&T/ Schneider) 7 i) 6 Way 8 Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. (Make - Legrand/ L&T/ Schneider) 9 i) 2+12Way 10 ii) 2+4 way 11 Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection as per GS(Make - Legrand/ L&T/ Schneider) 12 i) 125A FP MCCB 13 ii) 63A FP MCCB 14 Supplying and fixing 240/415 VMCB Isolator on din rail of existing DBs and necessary connection as per GS. (Make - Legrand/ L&T/ Schneider) 15 i) 40A DP 16 ii) 80A FP 17 Supplying and fixing 240/415V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connections per GS. (Make - Legrand/ L&T/ Schneider). 18 i) 6-32 A SP MCB 19 ii) 40 / 63 A TP MCB 20 iii) 63 A TPN MCB 21 B) Distribution Wiring & Plug Point 22 Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded FR PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/ fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall AND Supplying & Fixing sheet metal inspection box(16 SWG)/ blank modular plate etc.incl. mending good damages to original finish [Switch Board Make: Legrand Myrius or similar][RR Kabel/ Polycab/ Havells/ KEI] 23 i) Avg run 8Mtr 24 ii) On Board6A 25 Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI U hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles 26 i) 19 mm dia 3 mm thick. 27 Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI U hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles 28 i) 25mm dia 3mm thick Polythene Pipe 29 Supplying and Drawing 1.1 KV single core stranded FR PVC insulated & unsheathed single core stranded copper wire [RR Kabel/ Polycab/ Havells/ KEI] of the following sizes in the prelaid polythene pipe as per GS. 30 i) 2 x 1.5 sqmm. + 1 x 1.5 sqmm. 31 ii) 2 x 2.5 sqmm. + 1 x 1.5 sqmm. 32 iii) 2 x 4 sqmm. + 1 x 2.5 sqmm. 33 iv) 2 x 6 sqmm. + 1 x 4 sqmm. 34 v) 4 x 10 sqmm. + 2 x 6 sqmm. 35 vi) 4 x 16 sqmm. + 2 x 10 sqmm. 36 Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc including supplying sockets, tapes. 37 i) 2.5 sqmm. 38 ii) 4 sqmm. 39 iii)6 sqmm. 40 iv) 10 sqmm. 41 v) 16 sqmm. 42 Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm) flushed in wallas per GS. 43 i) 240 mm x 200 mm x 65 mm 44 ii) 300 mm x 200 mm x 65 mm 45 Supply & Fixing 240 V, 1 nos. 6 A, 5 pin Modular type plug socket with1 nos. 6 Amp Modular switch with indicator (Brand approved by EIC) on 3 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:- Legrand- Myrius or similar) 46 Supply & Fixing 240 V, 2 nos. 6 A, 5 pin Modular type plug socket with2 nos. 6 Amp Modular switch with indicator (Brand approved by EIC) on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:- Legrand- Myrius or similar) 47 Supply & Fixing 240 V, 1 no. 16 A, 6 pin Modular type plug socket with 1 no.16 Amp Modular switch with indicator (Brand approved by EIC) on 3/4 Module GI Modular type switch board with 3/4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(Make:- Legrand- Myrius or similar) 48 Supply & Fixing 240 V, 2 nos. 16 A, 6 pin Modular type plug socket with2 nos. 16 Amp Modular switch with indicator (Brand approved by EIC) on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:- Legrand- Myrius or similar) 49 Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(Make:- Legrand- Myrius or similar) 50 Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 20/25A Modular switch (Brand approved by EIC) type SP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(Make:- Legrand- Myrius or similar) 51 Supply & Fixing 240 V, 25 A OLP type starter (Brand approved by EIC) on 4 Module GI Modular type switch boardflushed in wall incl. S&F switch board and making necy. connections with PVC Cu wire and earth continuity wire etc. [Make: Electron OLP3+] 52 Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:- Legrand- Myrius or similar) 53 Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.(Make:- Legrand- Myrius or similar) 54 Supply and fixing of Timer DB (for Double AC machines) concealed in wall after cutting the wall & mending good the damages to original finish incl. necessary Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. The Timer DB comprises of following items -i) Double door enclosure (2+10/12way) with IP42/43 protection - 1No.ii) 240V, 32A SPN (DP) Isolator (Incomer) of - 1No.iii) Digital time Switch - 1No.iv)240V, 32A, 2 Pole power contactor - 2Nos.v) 240V, 6A DP Toggle switch - 1No.vi) 240V, 25A SP MCB (Outgoing) of Breaking capacity 10kA & C curve characteristics - 2Nos.vii) Copper bar for Ph, N, Earth - 3Nos.viii) Blank cover plate as required[Make: Legrand/ L&T/ Schneider] 55 Supply and fixing of Timer DB (for Single AC machine) concealed in wall after cutting the wall & mending good the damages to original finish incl. necessary Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. The Timer DB comprises of following items -i) Double door enclosure (2+10way) with IP42/43 protection - 1No.ii) 240V, 32A SPN (DP) Isolator (Incomer) of - 1No.iii) Digital time Switch - 1No.iv)240V, 32A, 2 Pole power contactor - 1No.v) 240V, 6A DP Toggle switch - 1No.vi) 240V, 25A SP MCB (Outgoing) of Breaking capacity 10kA & C curve characteristics - 1No.vii) Copper bar for Ph, N, Earth - 3Nos.viii) Blank cover plate as required[Make: Legrand/ L&T/ Schneider] 56 C) Fittings & Fixture 57 S & D of 240V, 50-55W 1star rated Heavy duty AC ceiling fan with safety wire. Blade Sweep size - 1200mm, RPM - 380. Minimum of Two years warranty.[Orient/ Crompton/ Usha] 58 Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. 59 Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2x1.5 sqmm flexible copper wire. 60 Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. 61 Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop. 62 Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) 63 S & F of 240V, 90W 1star rated Heavy duty full metal body Wall bracket fan. Blade Sweep size - 450mm, RPM - 1325. Minimum of Two years warranty.[Orient / Crompton / Usha] 64 Supply of 240V Exhaust fans complete with all accessories having the following Model. (Make -EPC Heavy Duty). 65 i) 40Watt, Blade sweep 9( 230mm ), Speed 1370 RPM 66 ii) 45Watt, Blade sweep 12( 300mm ), Speed 920 RPM 67 Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 68 i) 9( 230mm ) 69 ii) 12( 300mm ) 70 Supply & Fixing Aluminium louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 71 i) 9( 230mm ) 72 ii) 12( 300mm ) 73 S & D of 240V, 18/20W, 2100lm T8 LED tube lightfittings incl. LED tube (lumen efficacy > 100lm/W) (Cool daylight) with all accessories with a minimum of Two years warranty. [Make: Philips TMC -502/ with 18W Master LED tube/ Crompton IGP161LT8 wit Crysta LGT8 or similar of Wipro]. 74 i) Single tube fittings (1200mm) with one LED tube 75 ii) Double tube fittings (1200mm) with two LED tube 76 Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling with HW round block and suitable size of MS fastener 77 Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. 78 Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. 79 S & F10 Watt LEDlamp on angle holder for bracket point incl. making necessary ConnectionS &F 75mm angle batten holder (Anchor Make) incl. S&F of angular Holder. (Make-Philips/ Crompton/ Wipro) 80 S & F LED 240V, 10Wbulk head light fitting with complete set and making necessary connection as to GS.(Make-Philips - WT202W/Crompton - TIS304 / Wipro) 81 D) Compound Light 82 Supply and fixing of Timer DB for compound light concealed in wall after cutting the wall & mending good the damages to original finish incl. necessary Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. The Timer DB comprises of following items -i) Double door enclosure (2+10/12way) with IP42/43 protection - 1No.ii) 240V, 32A FP Isolator (Incomer) - 1No.iii) Digital time Switch - 1No.iv)240V, 32A, 3 Pole power contactor - 1No.v) 240V, 6A DP Toggle switch - 1No.vi) 240V, 25A TP MCB (Outgoing) of Breaking capacity 10kA & C curve characteristics - 1No.vii) Copper bar for Ph, N, Earth - 3Nos.viii) Blank cover plate as required[Make: Legrand/ L&T/ Schneider] 83 Supplying and Fixing GI water proof looping cable box (200x150x100mm) having hinged GI Top Cover having 4mm thick with rubber gasket lining railway type mechinical locking arrangment earthing terminal with lug etc. of the following sizes as indicate below Comprising of one 250 V 15 A kit kat fuse unit, One NL on Porcelian insulator etc. and Housing the same in pole muffing incl. addition and alternation to the existing CC muffing (6:3:1) after dismantiling the damaged looping cable box etc. where necy incl painting. 84 Supply & Delivery of 240V, 120W Outdoor type LED Street light with inbuilt PSU & SPD (IP66/65, IK08protection), THD < 10% with a Minimum of 3 years warranty from the date of Installation.[Make: Philips/ Crompton/ Wipro]. 85 Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. 86 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below (i) By ISI-Medium GI pipeor By TATA-Medium GI pipe. 87 Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emerypaper, cleaning etc. for receiving fresh coat of paint (1st coat of aluminium paint over 1 coat of RO priming) 88 E) L.T. PowerDistribution 89 S & D of 1.1kV grade XLPE insulated LT Al cable with . Aluminium conductor& armoured protecetion [Make: KEI/ Havells/ Gloster] 90 i) 4 core 70 sq.mm. (from Substation to VTPN) 91 ii) 4 core 6 sq.mm. (for compond light) 92 Laying of 4core 70sq.mm. 93 Laying of one No. cablein underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed 94 Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth of 100 mm and mending good the damages to original finish incl. removing the rubbish 95 Laying of cable on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting 96 Laying only Cable abovethrough existing RCC/ Hume/GI Pipe/open masonary trench forsingle, 2, 3, 3½ and 4 core 97 Laying of 4core 6sq.mm. 98 Laying of cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting 99 Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish 100 Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables of size 101 i) 4 core 70 sq.mm. 102 ii) 4 core 6 sq.mm. 103 Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials, cables of size- 3.5core 150 sq.mm. 104 i) 4 core 70 sq.mm. 105 ii) 4 core 6 sq.mm. 106 Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below (i) By ISI-Medium GI pipeor By TATA-Medium GI pipe. 107 Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required 108 Connecting the equipment to earth busbar including S & F GI (Hot-Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipment with bolts, nuts, washers, cable lugs etc. as required and mending good damages -4 SWG 109 Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. 110 Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing materials as required - 40 mm dia 111 Labour charges for dismantling of the existing electrical wiring, DBs, Fittingsetc. 112 Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage per storey of building per vertical run 113 Part - II (Dismantling & Re-Installation of AC Machines) 114 Dismantling of 1.5/2.0 Ton capacity Split/Window type A.C. machines 115 Installation of 1.5/2.0Ton capacity split type A.C. machine on the wall with nut, bolts etc. as necessary, includinginterconnection between indoor and outdoor unit using Copper pipe & cable including cutting holes on the wall,& arrangement for scaffolding as required 116 Supply & Fixing of the outdoor unit mounting bracket of high-grade carbon steel for the A.C. machines on the wall 117 S & F of5/8or 1/2 copper pipe for the (Gas line) connection between indoor and outdoor unit including supply and fixing of nitrile rubber insulation tube, taping material, etc. as required 118 S & F of 3/8 or 1/4 copper pipe for the (Liquid line) connection between indoor and outdoor unitincluding supply and fixing of nitrile rubber insulation tube, taping material, etc. as required 119 S & F of3 core 4.0 sq.mm. PVC Cu cable for connection between indoor & outdoor units (Make: Polycab/ Finolex/ KEI/ Gloster) 120 S & F of4 core 2.5sq.mm. PVC Cu cable for connection between indoor & outdoor units (Make: Polycab/ Finolex/ KEI/ Gloster) 121 S & F of PVC/ HDPE water pipe line for drainage of water from AC machines indoor unit to outside. [Make: Precision/ Universal/ Polycab/ AKG] 122 Supply & Charging of Refrigerant gas (R32/R410A/ R22) as per A.C. machines specification 123 TERMS & CONDITIONS 124 (i) Rate should be quoted inclusive of all applicable taxes and Duties etc including GST.(ii) All materials, accessories must conform to relevant IS / IEC specifications.(iii)Necessary manufacturers warranty certificate will have to be submitted during delivery of the material.