}

Tender For Provn Of Klp Accn Ph-Ii At Ambala Cantt, ambala-Haryana

Military Engineer Services has published Tender For Provn Of Klp Accn Ph-Ii At Ambala Cantt. Submission Date for this Tender is 03-07-2025. Building Work Tenders in ambala Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

49614374
Tender For Provn Of Klp Accn Ph-Ii At Ambala Cantt
Tender
Indian
Haryana
Ambala
03-07-2025

Tender Documents

Tender Details

Tender For Provn Of Klp Accn Ph-Ii At Ambala Cantt; 1 Total amount of Sch A Sec-I ( BUILDING WORKS ) Lump sum price worked out by the contractor for BUILDING WORKS as listed in schedule A Part-I 2 Total amount of Sch A Sec- II (SITE CLEARANCE, SITE DEVELOPEMENT & MISC. EARTH WORKS) Lump sum price worked out by the contractor for SITE CLEARANCE &Earth Works as listed in schedule A Part-II 3 Total amount of Sch A Sec- III ( INTERNAL WATER SUPPLY WORKS ) Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in schedule A Part-III 4 Total amount of Sch A Sec- IV (INTERNAL ELECTRIFICATION, TV, TELEPHONE, INTERCOME AND LAN WORKS) Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION AND ANCILARY WORKS OF COMMUNICATION NETWORKS as listed in schedule A Part-IV 5 Total amount of Sch A Sec- V (SEWAGE DISPOSAL WORKS) Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in schedule A Part-V 6 Total amount of Sch A Sec- VI(ROAD, PATH, CULVERTS AND HARDSTANDING WORKS) Lump sum price worked out by the contractor for ROAD, PATH, CULVERTS AND HARDSTANDING WORKS as listed in schedule A Part-VI 7 Total amount of Sch A Sec- VII(AREA DRAINAGE WORKS) Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in schedule A Part-VII 8 Total amount of Sch A Sec- VIII( FENCING& GATE WORKS) Lump sum price worked out by the contractor for SECURITY WALL, GATE &FENCING WORKS as listed in schedule A Part-VIII 9 Total amount of Sch A Sec- IX(EXTERNAL WATER SUPPLYWORKS) Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in schedule A Part-IX 10 Total amount of Sch A Sec- X(HOT WATER SUPPLYWORKS) Lump sum price worked out by the contractor for HOT WATER SUPPLY WORKS as listed in schedule A Part-X 11 Total amount of Sch A Sec - XIEXT ELECTRIC SUPPLY & LIGHTENING PROTECTION WORKS) Lump sum price worked out by the contractor for EXT ELECTRIC SUPPLY & LIGHTENING PROTECTION WORKS as listed in schedule A Part-XI. 12 Total amount of Sch A Sec- XII(SUMMER APPLIANCES WORKS) Lump sum price worked out by the contractor for SUMMER APPLIANCES WORKS as listed in schedule A Part-XII. 13 Total amount of Sch A Sec- XIII(RAIN WATER HARVESTING WORKS) Lump sum price worked out by the contractor for RAIN WATER HARVESTING WORKS as listed in schedule A Part-XIII 14 Schedule ASection-XIV (Misc Items of Works) Note :This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. 5 siginifies this fact only. 15 LIST OF WORKS FOR INTERNAL ELECTRIFICATION, TV, TELEPHONE, INTERCOM AND LANConcealed point wiring using approved colour coding as per IS, with 1.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H, drawn through and including heavy duty PVC conduit of appropriate dia(2mm wall thickness) and conduit accessories ISI marked, PVC junction boxes etc, concealed in walls/ceiling/floors including 1.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H as earth continuity conductor to common earth & connecting to earth dolly for the following :- 16 One light/bell/fan point (Ceiling/ Wall/ Exhaust) controlled by one number one way switch or one number one way switch and regulator 17 One light point conrolled by two numbers two way switches 18 One 5/6 Amps socket outlet on independent board 19 One 5/6 Amps socket outlet on the same board with other switches 20 Concealed point wiring using approved colour coding as per IS, for 15 Amps socket outlet on independent board with 2.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H, drawn through and including heavy duty PVC conduit of appropriate dia (2mm wall thickness)and conduit accessories ISI marked, PVC junction boxes etc, concealed in walls/ceiling/floors including 2.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H as earth continuity conductor to common earth & connecting to earth dolly.Notes for item Nos. 15 to 16 : (a) Modular metal flush boxes, modular cover plates with frame and switches/sockets etc shall be measured and paid separately under respective items of Sch A/BOQ here-in-after.(b) Cost of cutting/chases for concealing of conduit shall be deemed to be included in quoted lump sum of Sch A Section-I. 21 Lamp holder PVC/Polycarbonate type with back plate modular type complete all as specified and directed. 22 LED bulb, 12 W, inverter type, 230 V AC 50 Hz, retrofit, B-22 base complete, all as specified & directed. 23 Sheet metal enclosure vertical type double door DB TPN 4 way suitable to accomodate MCCB FP, 415 volts upto 100 Amps rating, protection class IP-54 IK-09 made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted as per IEC 61439-3, with copper bus bar of 200 Amps capacity for each phase, with two neutralbars, two Earth bars and cable ties for cable management including one No. MCCB four pole 63 Amps conforming to IEC 60947-2 & IS – 13947-3thermal magnetic releaseand adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 16 KA at 415 V AC , 50 Hz complete all as specified and directed. 24 Sheet metal enclosure vertical type double door DB TPN 8 way suitable to accomodate MCCB FP, 415 volts upto 100 Amps rating, protection class IP-54 IK-09 made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted as per IEC 61439-3, with copper bus bar of 200 Amps capacity for each phase, with two neutralbars, two Earth bars and cable ties for cable management including one No. MCCB four pole 160 Amps conforming to IEC 60947-2 & IS – 13947-3thermal magnetic releaseand adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 16 KA at 415 V AC , 50 Hz complete all as specified and directed. 25 MCB SP, 240 Volt , 50 Hz, 6 to 32 A, 10 KA , B curve, complete all as specified anddirected. 26 MCB SPN, 32 Amps, B Curve , 240 volt , 50 Hzs,10 KA,complete all as specified anddirected. 27 MCB TP 40 Amps, 415 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed. 28 MCB TP 63 Amps, 415 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed. 29 MCB TPN/FP 63 Amps, 415 volts, B-curve, rupturing capacity 10KA conforming to IEC-60898, Part-I complete, all as specified & directed. 30 Single pole and neutral enclosure with a two pin and earth plug with socket complete with one single pole MCB 20 Amps, complete all as specified and directed. 31 BLDC Ceiling fan energy efficient, minimum service value (m3/minute/Watt)>= 6.0, including modular electronic step type fan regulator, 2 module 120 watts fixed on cover sheet, 230 V, 50 Hz, 1200 mm sweep conforming to IS 374-2019, with all standard accessories as per manufacturers recommendations ,with provision of PVC insulated flexible cable FRLSH grade 3 core 0.5mm copper conductor 1100 volts grade from porcelain connector /ceiling rose to ceiling fan,complete all as specified and directed. 32 Energy saving LED light fitting , 1 x 20 watt, 230 volts, Decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with electronic driver and with best quality diffuser high lumen output, 2.5 KV voltage surge protection, PF 0.98, THD < 10 % suitable for surface/ pendant mounting complete with all accessories including and connecting of with twin core of PVC insulated 0.75 Sqmm copper conductor cable complete all asspecified and directed. 33 LED mirror light fitting with linear & compact 9 W mirror light with decorative grey end caps, polycarbonate body and ribbedopal diffuser of capacity 9 watt complete all asspecified and directed. 34 Recess mounted LED luminaire 600mm x 600mm size, 35/36 watt, 230 V, 50 Hz with highefficiency PMMA diffuser for soft glare free light colour temperature white with all standard fittings pre-wired and connecting the fitting from ceiling rose/connector using copper flexible cord of size 1.5sqmm, 3 core of suitable length complete all as specified and directed. 35 Energy generation energy saving and environmental friendly long life LED building security light 1 x 35 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having top opening separate driver compartment IP 65 protection and impact resistance of IK 07, with all accessories including suitable bracket with 32 mm bore light grade GI pipe bent to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed. 36 Flameproof exhaust fan of 300mm sweep, aluminium body,heavy duty, single phase AC 230/240V, with energy efficient motor, copper winding complete with louversincluding fixing/ grouting of frame & louvers in wall using bolts of suitable size & connecting with and including PVC flexible copper cable of size 23/00.0076 three core complete all as specified and directed.Note : Cost for making opening in wall and grouting of mild steel work shall be deemed include in the lump sum cost of the building. 37 Flame proof/weather proof direct entry typerotary switch singlepole,totally enclosed, on & OFF rotary motion switch in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 230Volts 16 Amps, AC ON/OFF switch operated externally by Knob having 02 Nos of M-20 cable entries, earthing terminals suitable for mounting on Wall/Steel structure etc duly tested & certified by CMRI-Dhanbad complete all as specified anddirected. 38 LED bulk head light fitting 1 x 30 watt flame proof & water proof, CMRI-Dhanbad certified recommended for gas/vapour group of II A & III B , Zone 1 & 2 and IP 66 protection with die cast aluminium housing with heat & impact resistant toughened A clear glass with LED tube light fixture driver, holders, connector etc,having anti-corrosive epoxi powder coated finish complete with all accessories prewired and incl connectingup with three core flexible copper conductor cable of suitable size complete all as directed. 39 LED light fitting 16/18 watt flame proof, CMRI-Dhanbad certified recommended for gas/vapour group of II A & III B , Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat & impact resistant toughened A clear glass with LED tube light fixture driver, holders, connector etc,having anti-corrosive epoxi powder coated finish complete with all accessories prewired and incl connectingup with three core flexible copper conductor cable of suitable size complete all as directed. 40 Modular socket outlet for Tele one Module ISI marked complete all as specified and directed. 41 Modular socket outlet for TV one Module ISI market complete all as specified and directed. 42 Coaxial cable consising of two conductors laid concentricallyalong the same axis. One conducting wire surrounded by a dielectricinsulator, which is in turn surrounded by the other, outer conductor , producing an electrically shieled transmission circuit for TV complete all as specified and directed. 43 RCBO A Type (SPN-2M) 32 Amp 30 mA (In accordance with IS 12640-2 & IEC 61009-1) 240 V/415 V 50 Hz, with 10 KA short circuit capacity, RCBO is designed for use in domestic , commercial and industrial distribution systems at the most downstream circuit for ensuring protection from leakage current, short circuit & over load to the user for a particularcircuit. In normal use, it is safe tio use and free of threatto user as well as toenvironment complete all as specfiedand directed . Make Havells Cat no DHCEACSN2030032 or equivalent in other specified makes. 44 Arc Fault Detection Device (AFDD) 32 A, rated voltage 415V AC , 50 Hz frequency, residual operatingcurrent 30 mA, three module, short circuit capacity 10 kA, type A, residual makingand breaking capacity 500 A, Electrical /Mechnical Endurance 10000 operations (made in India), terminal capacity 25 Sqmm protection class IP-20, protection class with enclosure IP-40 DIN Rail mounting method, Vibration Resistance 3g , Shock Resistance40mm free fall complete all as specfied and as directed. 45 Electric water heater (Vertical Type Geyser) storage type of capacity 25 Itr BEE 5 star rated , 2KW, ABS body, metal tank with glass lined coating, multiple heating option, shock safe plug, PUF insulation, incoly glass coated anode rod/ copper heating element ISI marked, adjustable knob for temp setting with minimum & high working pressure, multifunctional safety value, & whirl/swirl flow technology, thermostat electronic type including factory fitted inbuilt PRCD complete including superior quality copper connection pipe heavy duty 15 mm dia 450 mm long, brass adopter for water connection with nickel coated ISI marked with fastener, nut bolt, washers duly grouted, giving shape to hole as suitable and plastering including testing complete all as specified and directed. 46 Exhaust fan 300 mm sweep made of sturdy Engineering metal body, heavy duty, Single phase AC 230/240V, with energy efficient motor, pre lubricated double ball bearing, speed 900 rpm complete with louvers for wall mounting incl grouting,making hole in the wall andholding down bolts, nuts, washers and provision of flexible copper conductor cable 3 core from ceiling rose to exhaust fan incl cutting of hole of required size for fixing of the exhaust fan , complete all as specified and directed. 47 Concealed point wiring using approved colour coding as per IS, for 15 Amps socket outlet on independent board with 2.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H, drawn through and including stove enamelled steel conduit medium grade of 20mm dia with all fitting and assessories, ISI marked, PVC junction boxes etc, concealed in walls/ceiling/floors including 2.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H as earth continuity conductor to common earth & connecting to earth dolly.Notes: Cost of cutting/chases for concealing of conduit shall be deemed to be included in quoted lump sum of Sch A Section-I. 48 ROAD, PATH, CULVERTS AND HARDSTANDING WORKSPrecast (factory casted) cement concrete kerb stone casted in PCC (1:2:4) type B-1 using20mm graded stone aggregate with plain or interlocking joints (as directed), placing in erect position in edging and set and jointed in cement mortar 1:4, making good distrubed surface of ground complete all as specified and directed. 49 M & L for laying and compacting 150mm thick (compacted thickness) Granular Sub Base (GSB) grading as per Grading II of Table 400-1 of MoRTH specifications for Road and Bridge works, 2013 in a single layer over compacted sub grade consisting of natural sand, crushed gravel, crushed stone, crushed slag, or combination thereof as per the grading required. The materials are mechanically mixed, spread and leveling on the sub grade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 80-100 KN static weight for achieving required compaction density of at least 98 % of the Maximum Dry Density. Consolidating to required gradient and camber complete all as specified and directed with finished surface tolerances as per Table 900-1 of MoRTH specifications for Road and Bridge works, 2013 complete all as specified and directed. 50 Providing, Laying,compaction of Wet Mix Macadamconforming to Clause 406 of MORT&H Specifications for Road and Bridge Works (Fifth Revision) , 250 mm thick (compacted thickness,125 mm thick in two separate layers) with mechanically crushed graded stone aggregates and granular material (size range 53 mm to 0.075 mm ), grading of aggregatesas per Table 400-13 of MORT&H Specifications for Road and Bridge Works (Fifth Revision) ,including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 12 tonne capacity to achieve the desired density , required gradient and camber etc., complete all as specified and directed by Engineer-in-Charge.NOTES:1. The WMM shall be laid in two layers i.e each layer of 125 mm thick (compacted thickness).2. For payment purpose,both layers shall be considered as one unit. 51 Preparation ofun-surfaced Wet Mix macadam (WMM) surfaces by brushing with wire brushes for removing caked mud ,dust,loose material, foreign material etc., sweeping with power brooms and finally fanning the cleaned surface with air compressors to remove all loose dirt etc. and applying evenly a priming coaton un-surfaced wet mix macadam surfaces conforming to Clause 502 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), with cationic bituminous emulsion SS1 grade,confirming to IS 8887(latest edition) @ 7.5 kg per 10 sq metres using primer distributor which shall be self-propelled or towed bitumen pressure sprayer complete all as specified and directed. 52 Providing, laying & compaction of Bituminous Macadam (BM) 50 mm compacted thickness, conforming to clause 504 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), using mechanically crushed stone aggregates and granual material etc. ofgrading II as per Table 500-7 of MORT&H Specifications for Road and Bridge Works (Fifth Revision),premixed with bituminous binder, Bitumen grade VG-30 @ 3.50% (percentage by weight oftotal mix) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity transported to site by tippers, laid over a previously prepared surface with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density complete all as specified and directed.Notes : (i) The contractor shall quote the rate against Item considering 3.5% VG-30 bitumen content. Job mix formula as perMoRT&H specifications for road and bridge work (Fifth Revision) for bituminous concrete shall be got designed from NIT/ CTL/ Govt Engg College and shall be got approved from GE in writing well before commencement of work without any financial effect to the department. Also the bitumen content shall not be less 3.4% by weight of total mix as per clause 504.2.4 of MoRT&H specifications (Fifth Revision).(ii) If quantity of binder contents is less than the quantity as specified in respective items of BOQ, it shall be adjusted at supply only rates of paving bitumen @ Rs 45.00 Per Kg and if quantity of binder contents is more than the quantity as specified in respective items of BOQ, no adjustment shall be made. 53 Preparation ofbituminous black top surfacesand applying evenly a Tack coat conforming to Clause 503 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), with cationic bituminous emulsion RS1 grade,confirming to IS 8887(latest edition) @ 2.5 kg per 10 sq metres using using primer distributor which shall be self-propelled or towed bitumen pressure sprayer complete all as specified and directed. 54 Providing and laying 30 mm thick (consolidated thickness) Bituminous Concrete (BC) layer conforming to clause 507 of MoRT&H specifications for road and bridge work (Fifth Revision) including cost of coarse aggregates, fine aggregates, filler, 5.5% binder (paving Bitumen grade VG-30) content by weight of total mix and crushed aggregates of grading 2, Anti Stripping Agent, Warm Mix Additives (quantity, quality and grade as per the approved Job Mix Formula) etc,cleaning and pre-heating of the mineral aggregate, filler & bitumen to the specific temperature, thoroughly mixing with binder of specified bitumen content, Anti Stripping Agent, Warm Mix Additives as per mix design in Hot Mix Plant of 100-120 TPH capacity, carrying the hot mixed materials by means of tipper, trucks, or any other approved and suitable arrangements, laying the hot premixed materials over the prepared surface by means of paver finisher including manual operation as and when required for proper grade, level and camber thorough rolling with power roller 8 to 12 tonnes smooth wheeled, vibratory and tandem roller with necessary hand packing and pinning to give an even surface, including running expense of all plants and machineries, inclusive of proper traffic control during laying to the satisfaction of Engineer-in-Charge, required quality control tests at required interval etc complete in all respects complete all as specified and directed. 55 NOTES : (i) The contractor shall quote the rate against Item considering 5.5% VG-30 bitumen content. Job mix formula as per clause No 505.3.3 of MoRT&H specifications for road and bridge work (Fifth Revision) for bituminous concrete shall be got designed from NIT/ CTL/ Govt Engg College and shall be got approved from GE in writing well before commencement of work without any financial effect to the department. Also the bitumen content shall not be less 5.4% by weight of total mix as per clause 507.2.5 of MoRT&H specifications (Fifth Revision).(ii)The cost of materials, transportation, Job mix formula from lab and testing charges for various tests as required are included in the unit rate quoted by the contractor. (iii) Cost of filler i.e rock dust, hydrated lime or cement is deemed to be included in unit rate.(iv) If quantity of binder contents is less than the quantity as specified in respective items of BOQ, it shall be adjusted at supply only rates of paving bitumen @ Rs 45.00 Per Kg and if quantity of binder contents is more than the quantity as specified in respective items of BOQ no adjustment shall be made.(v) After spreading of mix as per clause 507.4.7 of MoRT&H specifications entire surface during the operation shall be rolled with road roller 8-10 tonnes (smooth wheeled) followed with vibratory road roller of 8 -10 tonnes static weight, followed by finish rolling with 6 to 8 tonnes smoooth wheeled tandem roller as per clause No 507.4.8 of MoRT&H specifications (Fifth Revision) and the cost of the same shall be deemed to be included in the quoted rate. 56 Preparing bituminious surfaces of road and marking 2.5 mm thick centre line, stop lines, dashes, arrows and the like, n.exc 10cm wide on roads pavements hot applied thermo plastic road marking paint of approved colour conforming to BS 3262-1989 with special applicator machine all as per manufacturers instruction completed all as specified and directed. 57 ABS body road studs (Cat eye) two way reflective of size 100 x 100 x 19mm with with reflective panels Amber/Red/White as directed fitted with epoxy resin and 12mm dia size 125mm long pointed nails completeall as specified and directed. 58 SolarLight Road studs LED based of size ( 108 x 108 x 25 mm) with Aluminium alloy body and Solar powered by nano crystal solar panel with one high capacity NI- CD Recahrgeable battery and three LED on each side (total six LEDs) fixed with epoxy resin and 12mm dia size 125mm long pointed nails completeall as specified and directed. model: DA-110-DHRUV of Make SINOR or equivalent. 59 Road safety convex mirror 80cm dia made out of PC material provided with suitaboe MS pipe post powder coated as per site requirement completed all as specified and directed 60 EXTERNAL WATER SUPPLYWORKSCuttingof existing DI/CI pipe line for tapping andinsertion of 80 mm GI tubing, fixing of 150 mm and 80 mm CI sluice valve as required on site .The accessories like Tail piece, Bend, collar, reducer of suitable size will be measured and paid separately in respecive item of schedule.Note:- (i) Excavation ,Returning filling and all earth work is included in these item. (ii)Titan joint /and lead joint required on site will be included in this item and nothing will be paid extra on these account. 61 Ductile iron fittings such as bends (any type, radius and angle) Tapers any type (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, Y junction, double branch, cross (all sockets or socket and spigot) collars, tail pieces with one end flanged (integrally cast) and one end socket/spigot caps and plugs suitable upto 200 mm bore ductile iron pressure pipes of K-9 classification including nuts, bolts, washer and push on flexible rubber gasket joints, complete all as specified and directed. 62 Construction of brick masonry valve pit of size 900 mm x 900mm x 900 mm (Internal size) thickness of walls shall be 23cm in brick work in cement mortar 1:6 internally plastered in cement mortar (1:6) and externally plastered in cement mortar (1:4) over 15cm thick PCC 1:4:8 type D-2 having 15cm offset around, including 4 cm thick coping in PCC 1:2:4 type B-1 on the top of the brick wall and 3mm thick mild steel sheet cover and angle iron frame of size 40 mm x 40mm x 6mm including provn of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed. 63 HOT WATER SUPPLY WORKSSupply instalation testing and commissiong of solar water heating system with ETC (Evacuated tube collector) TECHNOLOGY with electrical back up 3 KW suitable for single phase 220 V AC supply complete with ETC type collector, hot water tank,tank stands etc as per the following specifications:-(a) Collector - Collector 500 LPD ETC type with vertical evacuated tubes dully installed on angle iron frame transmittance of cover glass tube 85%,reflectance of glass tubes more than 85%,aborbance of glass tubes 92%, type of coating (Cu/AI/SS) and reflectance of coating as recommended by manufacture having wind resistance up to 100Km with freezing resistance uo to deg C and heating up coefficent 240 deg C having average thermal efficency 58.76% and maximum rise in temp 53.04 deg C (in 24 hours) without night losses fixed at angle of inclination from horizontal directed as Engr-in-charge. (b) Hot Water Tank - Hot water tank of 500 ltr capacity with suitable electrical back up for sufficent heating for all different capacity made out of stainless steel sheet not less than 0.5mm thick duly insulated with puff insulation 50mm thick having thermal conducitivity 0.29 m/k dully covered with PPIG cladding fixed with temperature gauge,inlet and outlet valves of suitable size duly installed on staging fabricated out of MS angle of approprite size as recommended by manufacturer duly fixed properly and painted with two coat of anti corrosive paint over a coat of red oxide primer. 64 All as per Srl item No 58.00above but 200 LPD. 65 Electric water heater (Geyser) storage type of capacity 25 Itr BEE 5 star rated , ABS body, metal tank with glass lined coating, multiple heating option, shock safe plug, PUF insulation, incoly glass coated anode rod/ copper heating element ISI marked, adjustable knob for temp setting with minimum & high working pressure, multifunctional safety value, & whirl/swirl flow technology, thermostat electronic type including factory fitted inbuilt PRCD complete including superior quality copper connection pipe heavy duty 15 mm dia 450 mm long, brass adopter for water connection with nickel coated ISI marked with fastener, nut bolt, washers duly grouted, giving shape to hole as suitable and plastering including testin complete all as specified and directed. 66 EXTERNAL ELECTRIC SUPPLY & LIGHTENING PROTECTION WORKS upplying, laying, jointing, testing and commisioning HT 11 KV (E) XLPE cable, insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2) extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part II with amendment, size 3 core & cross section area 95 Sqmm, laid in trenches/pipes/ducts/along poles/walls/ equipment etc complete all specified and directed. Note:- (i) All the cable shall be embossed with year of manufacturing, meterage at every metre in addition to its own standard makings as per IS i.e. Size, voltage etc. Cable shall also be tested in the presence of Engr-in-Charge after laying in the trench before returning filling in the trench.(ii) Excavation & earth work, GI pipe for laying of cable, sand cushioning & cable protection cover shall be measured and paid for seprately under respective items of the schedule. 67 Supply/Laying / fixing, jointing, testing and commissioning, LT under ground cable 1100 volts grade XLPE insulated & PVC sheathed cable heavy duty armoured, with multistranded aluminium conductor laid in trenches/ ducts/ pipes/fixed on walls/poles complete all as specified and directed of following sizes:-.Note:- 1. Excavation & earth work, GI pipe for laying of cable, sand cushioning & cable protection cover shall be measured and paid for seprately under respective items of the schedule.2. Cable length exceeding one drum length (i.e. exceeding 500 metre length ) shall beFACTORY PREMISES tested before dispatch in the presence of Rep of Accepting Officer. 3. Cable shall be tested in the presence of Engr-in Charge after laying in the trench before returning filling in the trench.(iii) Name of formation shall be printed on the cable after each size of exceeding (500 RM) length. 68 2 Core 16 Sqmm 69 3.5 Core 25 Sqmm 70 3.5 Core 35 Sqmm 71 3.5 Core 50 Sqmm 72 3.5 Core 70 Sqmm 73 3.5 Core 120 Sqmm 74 3.5 Core 150 Sqmm 75 3.5 Core 185 Sqmm 76 3.5 Core 240 Sqmm 77 3.5 Core 400 Sqmm 78 4 Core 10 Sqmm 79 4 Core 16 Sqmm 80 Dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed.Note :- Thickness after punning shall be considered for payment. 81 Supply and fix cable jointing kit, for 11 KV (earthed) grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumminum conductor cable of size 95 sqmm complete all as specified anddirected. 82 Unreinforced precast concrete cable cover,ISI Marked IS-5820 (Latest Edition) class HV, Type 1, flat, size 300mm x 180mm x 40mm for protection of HT cable complete all as specified and as directed. 83 Supply andlaying Sub class ‘B’ old size bricks laid adjacent to each other perpendicular to the direction of cable in trenches for protection of cable all as specified and directed. 84 M & L Cable rout indicater shown “ HT U/G cable HT/LT Cables” and root of cable with aero made of CI in suitable elliptical shape and fixed in MS rod 12 mm dia 70 cm long (all word embossed) and embaded in PCC block of size 30 x 30 x 60 cm in ground complete all as specified and directed. 85 Supply, transporting to site, erecting and fixing in truly verticle position, steel tubular swaged poles, type 410-SP-55 (11 metre long) for two pool structure complete consting of anty cling device, PCC foundation and cross arms etc,finial taper plug, bolts, nuts, scerws as specified, CI base plate including drilling holes and painting with two coats of aluminium paint externally, providing 30cm wide alternate strips with white and black synthetic enamal paint upto 1.2m height from ground level and numbering the pole (with black and white paint), undergruound part of the pole shall be painted with black bituminous paint complete all as specified and directed.Note: Excavation, earthwork & PCC foundation shall be measured and paid separately. 86 Supply, transporting to site, erecting and fixing in truly verticle position, steel tubular swaged pole, type 410-SP-22 (8.5 metre long) complete finial taper plug, bolts, nuts, scerws as specified, CI base plate including drilling holes and painting with two coats of aluminium paint externally, providing 30cm wide alternate strips with white and black synthetic enamal paint upto 1.2m height from ground level and numbering the pole (with black and white paint), undergruound part of the pole shall be painted with black bituminous paint complete all as specified and directed.Note: Excavation, earthwork & PCC foundation shall be measured and paid separately. 87 Junction Box of size 300 x 250 x 150 mm with locking arrangement suitable for aluminium bus bar (04 Nos) fixed on porcelain base insulator & 01 No MCB SP, 06A. Junctionbox made out of 2 mm thick MS sheet, painted with 2 coats of synthetic enamel paint over a coat of redoxide primer complete with suitable size of cable glands & MS clamps nuts, bolts & washes etc complete all as specified and directed. 88 LED street light fitting 60 watt 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant toughened glass cover complete with driver, lamp multiple optics, GI pipe bracket & MS clamp complete with IP 65/66 protection and impect resistance of IK08. 4kv inbuild and 10kv external surge protection and with top opening driver cover for easy maintenance complete all as specified and directed. Note:- Make of driver shall be same as that of luminaries. 89 Supply, fixing, testing and commissioning of air break gang operated switch triple pole mechanically operated outdoor type with all fittings/accessories mounted on and incl 11 KV HT porecain insulator and steel channel frame, GI operated rod 25 mm dia of suitable length with operating mechanism worked from ground level with dropout fuse consisting of 12 Nos insulators ISI marked, horizontal or vertically operated incl locking arrangement for operating handle with and including 7 lever lock with three Keys complete suitable for current rating of upto 200Amps HT 11 KV working pressure complete all as specified and as directed. 90 HT lightening arrestors ,non resistance type for out door use complete with all fittings and fixing arrangement such as brackets, clamps, nuts, washers and connecting to earth wire 4 mm dia GI wire, transmission class discharge capacity 10 KA, suitable for 11000 Volts, 3-phase, complete all as specied and directed.The design, manufacture and performance of Surge Arrestors shall comply with IS: 3070 Part-3, the equipment, material & processes shall conform to the latest amendments complete all as specified and directed. 91 Supply,install,commissioning & testingoftransformerstepdown11KV/433V,outdoortype, copper wound, capacity 500 KVA or nexthigher capacity, conforming to IS-1180 Part 2014, energy efficient BEE certified Level-2, necessary standard fittings of3 Phase, 4 wire, 50 cycles oil cooling with fins vector group Dyn-11 including initial oil filling, dehydrating breather with first fill of dehydrating agenthaving primary (HT) voltage of 11 KV and secondary (LT) voltage of433Voffloadtapchanginggeartoprovidevoltswithtappingonprimarysidehaving steps of + 2.5% from (+) 5% to (-) 7.5% in equal steps of 2.5% each so as to vary voltage on secondary side including first fill of transformer oil, the transformer shall be delta connected on 11KV side & star connected on secondary side with neutral brought out including provn of HT busing on HV (delta connection) side & LT cable box on LV (star connection) side complete all as specified and directed .Note:- (a) The temparature rise of the winding when measured by resistance mentioned shall not exceed 50 degree C and the temparature when measured by keeping the temparature on the top shall not exceed 45 degree C. 92 (b) Suitable plain rollers shall be fitted to the base of the Transformers to facilates transporting. The rollers shall be of cast steel and shall be detachable.(d) The Transformer shall be provided with the following accessories:- (i) Oil conservator with filling hole and oil level indicator. (ii) Silica gel breather complete with first fill of dehydrating agent. (iii) Tap filter Valve. (iv) Drain Valve. (v) Thermometer pocket with 100 mm dail type thermometer scaled 0 to 100 degree C. (vi) Explosion vent. (vii) 4 Nos earthing terminals. (viii) Plain rollers 04 Nos. (ix) Lifting hooks. (x) Rating and terminal making plates. (xi) Air relief plug. (xii) Buckles relay. (xiii) The Transformer should have HT cable insulator for outdoor type and HT bushing for outdoor type suitable for XLPE cable 95 SQmm 3 core and LT cable box suitable for upto 400 sqmm PVC cable.(xiv) Off load tap changing switch with handle and locking arrangement. (e) Transformer shall be mounted on PCC platform. PCC Platform & Chain link fencing on all sides of platform including provision of suitable size gate with locking arrangementshall be measured & paid separately. (f) Drg of platform must got approved from GE before execution.(g) Transformer shall be dispatched directly from the factory.(h) After installation of the transformer the same shall also be tested by IEM/SEI and all the equipment/instrument required for testing shall be provided by the contractor. 93 M & L for platform for transformer of size 3000 x 2500 x 1200 mm with brick masonry construction in cement mortar 1:4, PCC (1:4:8) type D-2 150 mm thick in foundation, PCC (1:2:4) type B-1, 40 mm thick in floor over sub base PCC (1:4:8) type D-2, 75 mm thick, brick masonry step on one side, 15mm thick plastering to brick masonry in cement mortar 1:4 and two coats of white wash on plastered surface including excavation and earth work in any type of soil complete all as specified and directed. 94 Supply, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), LT Panel (KIOSK) of appropriate dimensions (as per Indian Electricity rules) to accommodate following components, outdoor type, floor mounted front and back openable, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having 01 No bus bar chambers with insulated Copper bus bars 1200 Amps rating installed on porcelain insulators and cable alley for cables. The panel shall be dust and vermin proof, IP 67 class protection and outer enclosure made out of 3.15mm thick CRCA sheet and angle iron 40x40x6mm thick frame work includinginner compartments made out of 2.0mm thick CRCA sheet, complete panel powder coated finish over one coat of red oxide primer(after 9 tank treatment process), front & rear opening type, with aprons for cable entry, with removable door shutter and locking arrangement {including provn of 65mm Godrej (Freedom)/Harrison lock with 3 keys}, internal wiring with PVC insulated, multistranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. The scope of work includes the following:-(a) Copper bus bar of rating 1200 Amps for four pole including PVC heat shrink sleeves (RYB & N ) : 01 Set. (b)ACB four pole 800 Amp 50 KA (Incoming): 01 No.(c) MCCB four pole 400Amp conforming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 36 KA at 415 V AC , 50 Hz complete: - 01 No.(d) MCCB four pole 200 Amp conforming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 36 KA at 415 V AC , 50 Hz complete: 02 Nos. (e) MCCB four pole 160 Amp conforming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete: 01 No. 95 (f) MCCB four pole 40 Amp confirming to IEC 65647-2 & IS –13947-3thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete - 01 No.(g) 24 hour programmable astronomical time switch, Auto/Manual selector switch-01 No, pre-wired ready to use, intalled in enclosure with liberal termination space, louvers provided on both sides for proper heat dissipation, with three phase 63 Amps power contactor - 01 No. and MCB TPN - 63 Amps - 01 No. as incoming including setting of the astronomical time switch, testing and commissioning complete - 01 Job.(h) CONTROL/METERING COMPONENTS(i)Digital type multi function meter to display voltage, current, frequency, PF etc- 01 No.(ii) Indication lamps R,Y,B ( LED type) - 01 Set of 03 Nos.(The consolidated rate for Srl No. 84.00 & 84.10 shall be quoted against Srl No.84.00 of BOQ.) 96 Supply, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), electric control panel of appropriate dimensions (as per Indian Electricity rules) to accommodate following components, outdoor type, floor mounted front and back openable, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having 01 No bus bar chambers with insulated Copper bus bars 1200 Amps rating installed on porcelain insulators and cable alley for cables. The panel shall be dust and vermin proof, IP 67 class protection and outer enclosure made out of 3.15mm thick CRCA sheet and angle iron 40x40x6mm thick frame work includinginner compartments made out of 2.0mm thick CRCA sheet, complete panel powder coated finish over one coat of red oxide primer(after 9 tank treatment process), front & rear opening type, with aprons for cable entry, with removable door shutter and locking arrangement {including provn of 65mm Godrej (Freedom)/Harrison lock with 3 keys}, internal wiring with PVC insulated, multistranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. The scope of work includes the following:-(a) Copper bus bar of rating 600 Amps for four pole including PVC heat shrink sleeves (RYB & N ) : 01 Set. (b) MCCB four pole 400Amp conforming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 36 KA at 415 V AC , 50 Hz complete: - 01 No. (Incoming) (c) MCCB four pole 320 Amp conforming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete: 01 No.(d) MCCB four pole 100 Amp conforming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete: 01 No. 97 (e) MCCB four pole 32 Amp conforming to IEC 65647-2 & IS –13947-3thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete - 01 No. (f) MCB TPN 40-63 Amp and rupturing capacity 25 KA at 415 V AC , 50 Hz C Curve complete - 01 No.(h) MCB SPN 6-32 Amp and rupturing capacity 10 KA at 415 V AC , 50 Hz B Curve complete - 03 No. (g) 24 hour programmable astronomical time switch, Auto/Manual selector switch-01 No, pre-wired ready to use, intalled in enclosure with liberal termination space, louvers provided on both sides for proper heat dissipation, with three phase 63 Amps power contactor - 01 No. and MCB TPN - 63 Amps - 01 No. as incoming including setting of the astronomical time switch, testing and commissioning complete - 01 Job. (h) Space for spare MCCB - 01 No.(l) CONTROL/METERING COMPONENTS(i)Digital type multi function meter to display voltage, current, frequency, PF etc- 01 No.(ii) Indication lamps R,Y,B ( LED type) - 01 Set of 03 Nos.(The consolidated rate for Srl No. 84.00 & 84.10 shall be quoted against Srl No.84.00 of BOQ.) 98 Supply, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), electric control panel of appropriate dimensions (as per Indian Electricity rules) to accommodate following components, outdoor type, floor mounted front and back openable, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having 01 No bus bar chambers with insulated Copper bus bars 1200 Amps rating installed on porcelain insulators and cable alley for cables. The panel shall be dust and vermin proof, IP 67 class protection and outer enclosure made out of 3.15mm thick CRCA sheet and angle iron 40x40x6mm thick frame work includinginner compartments made out of 2.0mm thick CRCA sheet, complete panel powder coated finish over one coat of red oxide primer(after 9 tank treatment process), front & rear opening type, with aprons for cable entry, with removable door shutter and locking arrangement {including provn of 65mm Godrej (Freedom)/Harrison lock with 3 keys}, internal wiring with PVC insulated, multistranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. The scope of work includes the following:-(a) Copper bus bar of rating 300 Amps for four pole including PVC heat shrink sleeves (RYB & N ) : 01 Set. (b) MCCB four pole 160Amp conforming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 36 KA at 415 V AC , 50 Hz complete: - 01 No. (Incoming) (c) MCCB four pole 125Amp conforming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete: - 01 No.(d) MCCB four pole 63 Amp conforming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete: 01 No. 99 (e) MCB 2 pole 6-16 Amp and rupturing capacity 10 KA at 415 V AC , 50 Hz B Curve complete - 02 No. (f) 24 hour programmable astronomical time switch, Auto/Manual selector switch-01 No, pre-wired ready to use, intalled in enclosure with liberal termination space, louvers provided on both sides for proper heat dissipation, with three phase 63 Amps power contactor - 01 No. and MCB TPN - 63 Amps - 01 No. as incoming including setting of the astronomical time switch, testing and commissioning complete - 01 Job. (g) CONTROL/METERING COMPONENTS(i)Digital type multi function meter to display voltage, current, frequency, PF etc- 01 No.(ii) Indication lamps R,Y,B ( LED type) - 01 Set of 03 Nos.(The consolidated rate for Srl No. 84.00 & 84.10 shall be quoted against Srl No.84.00 of BOQ.) 100 Supply, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), electric control panel of appropriate dimensions (as per Indian Electricity rules) to accommodate following components, outdoor type, floor mounted front and back openable, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having 01 No bus bar chambers with insulated Copper bus bars 1200 Amps rating installed on porcelain insulators and cable alley for cables. The panel shall be dust and vermin proof, IP 67 class protection and outer enclosure made out of 3.15mm thick CRCA sheet and angle iron 40x40x6mm thick frame work includinginner compartments made out of 2.0mm thick CRCA sheet, complete panel powder coated finish over one coat of red oxide primer(after 9 tank treatment process), front & rear opening type, with aprons for cable entry, with removable door shutter and locking arrangement {including provn of 65mm Godrej (Freedom)/Harrison lock with 3 keys}, internal wiring with PVC insulated, multistranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. The scope of work includes the following:-(a) Copper bus bar of rating 300 Amps for four pole including PVC heat shrink sleeves (RYB & N ) : 01 Set.(b) MCCB four pole 160Amp conforming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 36 KA at 415 V AC , 50 Hz complete: - 01 No. (Incoming)(c) MCCB four pole 100 Amp conforming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete: 01 No. 101 (d) MCB TPN 40 Amp and rupturing capacity 10 KA at 415 V AC , 50 Hz B Curve complete - 02 No. (e) 24 hour programmable astronomical time switch, Auto/Manual selector switch-01 No, pre-wired ready to use, intalled in enclosure with liberal termination space, louvers provided on both sides for proper heat dissipation, with three phase 63 Amps power contactor - 01 No. and MCB TPN - 63 Amps - 01 No. as incoming including setting of the astronomical time switch, testing and commissioning complete - 01 Job. (f) Space for spare MCCB - 01 No.(g) CONTROL/METERING COMPONENTS(i)Digital type multi function meter to display voltage, current, frequency, PF etc- 01 No.(ii) Indication lamps R,Y,B ( LED type) - 01 Set of 03 Nos.(The consolidated rate for Srl No. 84.00 & 84.10 shall be quoted against Srl No.84.00 of BOQ.) 102 Supply, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), electric control panel of appropriate dimensions (as per Indian Electricity rules) to accommodate following components, outdoor type, floor mounted front and back openable, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having 01 No bus bar chambers with insulated Copper bus bars 1200 Amps rating installed on porcelain insulators and cable alley for cables. The panel shall be dust and vermin proof, IP 67 class protection and outer enclosure made out of 3.15mm thick CRCA sheet and angle iron 40x40x6mm thick frame work includinginner compartments made out of 2.0mm thick CRCA sheet, complete panel powder coated finish over one coat of red oxide primer(after 9 tank treatment process), front & rear opening type, with aprons for cable entry, with removable door shutter and locking arrangement {including provn of 65mm Godrej (Freedom)/Harrison lock with 3 keys}, internal wiring with PVC insulated, multistranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. The scope of work includes the following:-(a) Copper bus bar of rating 300 Amps for four pole including PVC heat shrink sleeves (RYB & N ) : 01 Set.(b) MCCB four pole 200Amp conforming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 36 KA at 415 V AC , 50 Hz complete: - 01 No. (Incoming)(c) MCCB four pole 160 Amp conforming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete: 01 No. 103 (d) MCB TPN 40 Amp and rupturing capacity 10 KA at 415 V AC , 50 Hz C Curve complete - 01 No.(e) MCB 2 pole 6-32 Amp and rupturing capacity 10 KA at 415 V AC , 50 Hz B Curve complete - 01 No. (f) 24 hour programmable astronomical time switch, Auto/Manual selector switch-01 No, pre-wired ready to use, intalled in enclosure with liberal termination space, louvers provided on both sides for proper heat dissipation, with three phase 63 Amps power contactor - 01 No. and MCB TPN - 63 Amps - 01 No. as incoming including setting of the astronomical time switch, testing and commissioning complete - 01 Job. (g) Space for spare MCCB - 01 No.(h) CONTROL/METERING COMPONENTS(i)Digital type multi function meter to display voltage, current, frequency, PF etc- 01 No.(ii) Indication lamps R,Y,B ( LED type) - 01 Set of 03 Nos.(The consolidated rate for Srl No. 84.00 & 84.10 shall be quoted against Srl No.84.00 of BOQ.) 104 Supply, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), electric control panel of appropriate dimensions (as per Indian Electricity rules) to accommodate following components, outdoor type, floor mounted front and back openable, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having 01 No bus bar chambers with insulated Copper bus bars 1200 Amps rating installed on porcelain insulators and cable alley for cables. The panel shall be dust and vermin proof, IP 67 class protection and outer enclosure made out of 3.15mm thick CRCA sheet and angle iron 40x40x6mm thick frame work includinginner compartments made out of 2.0mm thick CRCA sheet, complete panel powder coated finish over one coat of red oxide primer(after 9 tank treatment process), front & rear opening type, with aprons for cable entry, with removable door shutter and locking arrangement {including provn of 65mm Godrej (Freedom)/Harrison lock with 3 keys}, internal wiring with PVC insulated, multistranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. The scope of work includes the following:-(a) Copper bus bar of rating 100 Amps for four pole including PVC heat shrink sleeves (RYB & N ) : 01 Set. (b) MCCB four pole 63Amp conforming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete: - 01 No. (Incoming)(c) MCCB four pole 25 Amp conforming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 16 KA at 415 V AC , 50 Hz complete: 01 No. 105 (d) MCB 2 pole 32 Amp and rupturing capacity 10 KA at 415 V AC , 50 Hz B Curve complete - 03 No. (f) 24 hour programmable astronomical time switch, Auto/Manual selector switch-01 No, pre-wired ready to use, intalled in enclosure with liberal termination space, louvers provided on both sides for proper heat dissipation, with three phase 63 Amps power contactor - 01 No. and MCB TPN - 63 Amps - 01 No. as incoming including setting of the astronomical time switch, testing and commissioning complete - 01 Job. (g) Space for spare MCCB - 01 No.(h) CONTROL/METERING COMPONENTS(i)Digital type multi function meter to display voltage, current, frequency, PF etc- 01 No.(ii) Indication lamps R,Y,B ( LED type) - 01 Set of 03 Nos.(The consolidated rate for Srl No. 84.00 & 84.10 shall be quoted against Srl No.84.00 of BOQ.) 106 Supply, installing, testing and commissioning, factory made and tested (incl CPRI type test certified), electric control panel of appropriate dimensions (as per Indian Electricity rules) to accommodate following components, outdoor type, floor mounted front and back openable, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having 01 No bus bar chambers with insulated Copper bus bars 1200 Amps rating installed on porcelain insulators and cable alley for cables. The panel shall be dust and vermin proof, IP 67 class protection and outer enclosure made out of 3.15mm thick CRCA sheet and angle iron 40x40x6mm thick frame work includinginner compartments made out of 2.0mm thick CRCA sheet, complete panel powder coated finish over one coat of red oxide primer(after 9 tank treatment process), front & rear opening type, with aprons for cable entry, with removable door shutter and locking arrangement {including provn of 65mm Godrej (Freedom)/Harrison lock with 3 keys}, internal wiring with PVC insulated, multistranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 4 sqmm. The scope of work includes the following:-(a) Copper bus bar of rating 100 Amps for four pole including PVC heat shrink sleeves (RYB & N ) : 01 Set.(b) MCCB four pole 40Amp conforming to IEC 65647-2 & IS – 13947-3 thermal magnetic release and adjustable over load setting 0.8 – 1.0 x In and adjustable short circuit setting 6 – 10 x In and rupturing capacity 25 KA at 415 V AC , 50 Hz complete: - 01 No. (Incoming) 107 (c) MCB 2 pole 6-32 Amp and rupturing capacity 10 KA at 415 V AC , 50 Hz B Curve complete - 07 No. (c) 24 hour programmable astronomical time switch, Auto/Manual selector switch-01 No, pre-wired ready to use, intalled in enclosure with liberal termination space, louvers provided on both sides for proper heat dissipation, with three phase 63 Amps power contactor - 01 No. and MCB TPN - 63 Amps - 01 No. as incoming including setting of the astronomical time switch, testing and commissioning complete - 01 Job. (d) Space for spare MCCB - 01 No.(e) CONTROL/METERING COMPONENTS(i)Digital type multi function meter to display voltage, current, frequency, PF etc- 01 No.(ii) Indication lamps R,Y,B ( LED type) - 01 Set of 03 Nos.(The consolidated rate for Srl No. 84.00 & 84.10 shall be quoted against Srl No.84.00 of BOQ.)Notes for ser item No 76to 82 :-(a) All armoured cables shall enter through bottom of the feeder pillar duly glanded and socketed and connected to MCCB/cable terminal. Cost of glanding socketing etc are deemed to be included in the unit rate of feeder pillar.(b) All the out going cable shall be terminated in bakellite cable connector and shall be duly glanded and socketed.(c) All the cables (power and control wiring ) should be terminated duly socketed with heavy duty tinned copper lugs, GI bolts/screws nuts, flat washers and spring washers as required.(d) White acrylic marker plate (for feeder / switch marking ) to be provided with black lettering by heat press machine as indicated in drawing and to be pasted over the panel door/near the cable connector with high quality adhesive.(e) The cost of platform/foundation with PCC shall deemed to be included in the quoted rates.(f) All MCCBs/instruments/MCBs/Bus Bar shall be housed in a separate housing with on- off latches in the housing.(g) The consolidated rate for Srl No. 84.00 & 84.10 shall be quoted against Srl No.84.00 of BOQ. 108 Earthing complete with and including galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected with and including galvanised iron or steel earth wire, 4mm dia (No. 8 SWG) by means bolts, nuts, check nuts and washers made out of galvanised iron, 15 mm bore (medium grade) GI pipe for protection of earthing lead, 20 mm bore (medium grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC 1:1.5:3 type A-1 reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SSR PartI (2009) complete all as specified and directed.NOTE : The unit rate includes for protecton pipe 15mm and GI earth wire 4mm from top of earth plate upto 7.50 metre above ground level. 109 Earthing with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron 32x6mm earth strip by means of bolts, nuts check nuts and washers of galvanized iron or steel with protection pipe of GI, medium grade 40mm bore, watering pipe 20mm bore of GI medium grade, earth plate surrounded by alternate layer of coal dust and common salt 15 cm thick each layer all as per electrical plate No 3 of SSR Part-I and connected to earthing test point all as specified or indicated and testing on completion including funnel with wire mesh, earthing chamber with PCC (1:2:4) type B-1 using 20mm graded stone aggregate, 80 mm thick precast RCC 1:1.5:3 type A-1 cover duly reinforced with XPM (weight not less than 3 kg/sqm) and frame including all excavation and earth work etc. complete all as specified and directed.NOTE : 1. Earth chamber shall be constructed at least 1.50 metre away from the top of earth electrode, the earth pit and pipe for watering shall be provided in slanting manner.2.Cost of 7.5m length of GI strip & GI protection pipe shall be deemed to be included in the rate of this item. Extra length shall be measured and paid for separately.(For external & internal elect ) 110 Test point terminal block made of gun metal or phosphorous bronze 75x75x25mm drilled and screwed including 04 Nos 8mm dia 25mm long hexagonal head brassscrews including box of size 90x90x90mm made out of 1.6mm CRCA sheet painted with two coats of synthetic enamel paint over a coat of red oxide primer, and screwed to wall for protection of test point complete complete all as specified and as directed. 111 Aluminium conductor, steel reinfored of any size for making of bus bar at four pole structure & other connectioncomplete all as specified and directed. 112 Pin type insulator, HT porcelain vitreous white, brown or green of size 150 mm high and 150 mm dia, ISI marked including one galvanised steel spindle, two galvanised iron washers and one galvanised iron nut suitable for 11000 volts complete all as specified and directed. 113 250 KVAR APFC PANEL WITH MPP-H CAPACITOR AND MCCB AS INCOMER with 6 steps(2x25 + 4x50) suitable for 500 Kva transformer, fabricated from 16 SWG CRCA sheet, floor mounting suitable for INDOOR installation with IP42 protection.The Panel shall be made dust and vermin proof by providing good quality gaskets and doors, removal covers gland plate etc. all the live parts inside the panel shall be covered with perforated sheet from the rear with fibre glass acrylic from the front as per the degree of protection specified The Panel enclosure shall be powder coated by minimum 11 tank process with shades Siemens grey RAL 7032 of IS -5 or Orange .Cabinet doors shall be equipped with concealed of detachable type hinges and with flush cylinders locks. All joint and connection shall be made by galvanized or cadmium plated high tensile strength bolts, nuts and washer. Suitable bottom to top forced cross ventilation system shall be provided especially in capacitor bank Busbar / Jumper shall be fully insulatedand shall be sleeved. Busbar shall be of copper and completely covered. Capacitors, switchgears and panel shall be manufactured completely Inhouse and from the same make. 6 Step Microprocessor based APFC relay consist of function: 114 IOT Enabled 3CT Sensing, 11mA current sensitivity, Automatic kVAr value sensing, wide band Aux supply 90-550V with multifunction electrical parameter display like Voltage, Current, Frequency, KW, KVA, KVAr, KWH, KVAH, kVAr and THD 1% and THD V% upto 33rd level, Automatic CT polarity error detection, selectable Step time and discharge time, selectable Target Power factor from lag 0.800 to lead 0.800 in steps of 0.XXX with Alarm facility. Capacitor Super Heavy Duty MPP SH with Penta safety, Capacitor with ISI mark and BIS certification, and having overcurrent with stand capacity of 3.0lr, peak inrush current withstand capacity of 500times In and switching per year 65000 times.The manufacturer shall be by ISO 9001:2015, ISO 18001:2007, ISO 14001:2010 & ISO 50001:2011 certified. Incomer MCCB 630A 50KA, Selector switch AUTO/ Manual. suitable capacitor duty contactor, and MCCB for separate bank of 16kA, illuminating Auto/manual switch control mcb for protection, fan and louver for ventilation.The Steps required for 300KVAR panel will be as (100x1,50x3,25x1,10x2,5x1) step complete all as specified and directed 115 SUMMER APPLIANCESSupply installation commissioning and testing air cooled split type Air Conditioner electric driven single phase of 1.5 TR capacity inverter type having EER star rating not less than 4.5(WW), type of refrigerant 410-A complete all as specified and directed.Note :- Contractors quoted rates shall be deemed to include for cost of pair of mounting bracket heavy duty for outdoor unit, additional copper pipe as required beyond standard supply with AC, additional insulation material for copper pipe as required beyond standard supply with AC, drainout pipe from indoor unit to outside building as directed. 116 Supply installation commissioning and testing air cooled split type Air Conditioner electric driven single phase of 2.0 TR capacity inverter type having EER star rating not less than 4.5(WW), type of refrigerant 410-A complete all as specified and directed.Note :- Contractors quoted rates shall be deemed to include for cost of pair of mounting bracket heavy duty for outdoor unit, additional copper pipe as required beyond standard supply with AC, additional insulation material for copper pipe as required beyond standard supply with AC, drainout pipe from indoor unit to outside building as directed. 117 Supply installation commissioning and testing of Refrigerators frost free 5 star rating, eco-friendley R-134-A & 438-A refrigernt,electric driven (single phase) of capacity 180 to 200 litre complete all as specified and directed. 118 Supply installation commissioning and testing of Refrigerators frost free 5 star rating, eco-friendley R-134-A & 438-A refrigernt,electric driven (single phase) of capacity not less than 310 litre complete all as specified and directed. 119 Supply installation commissioning and testing of hard top Deep freezer single phase 240 Volts 50 HZs of capacity not less than 120 litre complete all as specified and directed. 120 Supply, installation,testing and commissioning of self standing Water cooler fully stainless steel, puff insulated body, electric driven single phase 230 Volts, 50 Hz having storage capacity of 80 Ltr and nominal cooling capacity of 40 Ltr per hour with reciprocating compressor, eco-friendley R-134-A & 438-A refrigernt, externally mounted thermostat for easy regulating temperature with extra large stainless steel water tray for fast drainage of water complete all as specified and as directed. 121 Supply and installed desert cooler electric driven (single phase)with outer body made of pgi sheet not less than 1.2 mm thickness for fixed part ,thickness of PGI sheet for shutter not less than 0.80 mm thickness of front gril made of PGI sheet with minimum weight 2.8 kgs ,overall outer size not less than 695mmx 540mm x1010 mm hight copper woond fan motor having nominal air flow fan type capacity of 4000cum per hour and submersible pump for required flow of water complete all as specified and directed. Note: MS frame work for mounting/ fixing of Desert cooler shall be measured and paid separately. 122 Supply, installation, testing and commissioning voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for input varriation between 170 V to 290 V with output voltage stablized at 230 V with accuracy of +/- 2.5% and of capacity 2.0 KVA complete all as specified and as directed. 123 Supply, installation,testing and commissioning voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for input varriation between 170 V to 290 V with output voltage stablized at 230 V with accuracy of +/- 2.5% and of capacity 3.0 KVA complete all as specified and as directed. 124 Supply, installation,testing and commissioning voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for input varriation between 170 V to 290 V with output voltage stablized at 230 V with accuracy of +/- 2.5% and of capacity 4.0 KVA complete all as specified and as directed. 125 RAIN WATER HARVESTING WORKSDrilling pilot bore hole of 150mm dia by rotary drilling method (Direct/ reverse) through rig machine for injection well in any kind of soil strata or rock including disposal of surplus soil/rock to a distace not exceeding 50 metre complete all as specified including deploying required rig machinery, T&P, equipment etc complete inclduing transporting of all materials like rig machine, tool and plants, collection of log samples (drilling/ cutting) and to maintain drill time log bookcomplete all as specified and directed. 126 Reaming of 150mm pilot bore hole to 300mm bore with direct circulation rig machine/ reverse rotary circulation method in any kind of strata of soil/rock from ground level to 100 Metre depth below ground level complete all as specified and directed.Notes for item No 100 to 110.(a) The follwoing activities are to be carried out and reports, as mentioned, to be submitted by the contractor which is deemed included in the rates quoted:-(i) Taking the sample of strata at every 3.0metre interval and every change in strata and preparation of litho logs based on these samples (Cost of provision of sample straae box size 1200 x 750X100mm of specification as directed by GE shall be deemed included in the quoted rates). (ii)Preparation of drill time log and sumbitting to deptt.(b) The change in upper or lower limit of depth of boring from ground level with a particular dia of drill will not amount to any deviation and rates quoted against these items are only applicable even if drilling depth varies from Sch `A and nothing extra shall be admissible on this account. 127 Supply, assembling, jointing, lowering and fixing in postion PVC plain casing pipe, heavy duty of size 150mm bore & thickness 7.5 to 8.5mm conforming to IS- 4985 having male threads at spigot end and female threads at socket end screwed and socket type including all jointing accessories complete all as specified and directed. 128 Supply assemnling, jointing, lowering and fixing in position PVC screen casing pipe, heavy duty of size 150mm having slot of size 1.50 mm, wall thickness 7.5 to 8.5 mm conforming to IS-4985 having male threads at spigot and female threads at socket end, screwed and socket type including all jointing accessories complete all as specified and directed. 129 PVC bail plug assembly suitable for 150 mm nominal bore PVC casing pipe internally threaded and jointed with casing pipe complete all as specied and directed. 130 Mild steel hosing clamps, made out of 12mm thick MS flat bend to shape for 150mm bore casing pipe with necessary bolts, nuts and washers at ground level complete all as specified and directed. 131 PVC borewell cap 8 mm thick, suitable for 150mm bore having internal threads complete all as specifed and directed. 132 Development of injection bore well by using air compressor of suitable capacity for removing the drilling mud and finer sediments in the surrounding of borewell screens complete all as specifed and directed (5 hours for each well). 133 Supply and packing pea gravel of size 2 mm to 5 mm all around casing pipe and slotted pipe complete all as specified and directed 134 PVC cross of size 150 mm dia with 100 mm dia branches heavy duty having internal threads complete all as specified and directed. 135 PVC screened collector pipe having slot of 1.5 mm size heavy duty of size 100 mm dia complete all as specified and directed 136 150 mm dia UPVC pipe, laid in trenches at any depth including fittings, jointing completeall as specified and directed.

Key Value

Document Fees
INR 3000 /-
EMD
INR 1500000.0 /-
Tender Value
INR 35.81 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail