}

Tender For Misc Repairs To Electrical Supply System, Capacitor Panel, High Mast, Amf Panel And Allied Works At Aoc Centre Mudfort, Hanuman Temple Havelock Line, Ncc, Dou, Safilguda, Sappers Line, Abc Line Solar Plant And Adjoining Area Under Age Em I, secunderabad-Telangana

Military Engineer Services has published Tender For Misc Repairs To Electrical Supply System, Capacitor Panel, High Mast, Amf Panel And Allied Works At Aoc Centre Mudfort, Hanuman Temple Havelock Line, Ncc, Dou, Safilguda, Sappers Line, Abc Line Solar Plant And Adjoining Area Under Age Em I. Submission Date for this Tender is 02-07-2025. Electrical Products Tenders in secunderabad Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

49611690
Tender For Misc Repairs To Electrical Supply System, Capacitor Panel, High Mast, Amf Panel And Allied Works At Aoc Centre Mudfort, Hanuman Temple Havelock Line, Ncc, Dou, Safilguda, Sappers Line, Abc Line Solar Plant And Adjoining Area Under Age Em I
Tender
Indian
Telangana
Secunderabad
02-07-2025

Tender Documents

Tender Details

MISC REPAIRS TO ELECTRICAL SUPPLY SYSTEM, CAPACITOR PANEL, HIGH MAST, AMF PANEL AND ALLIED WORKS AT AOC CENTRE MUDFORT, HANUMAN TEMPLE HAVELOCK LINE, NCC, DOU, SAFILGUDA, SAPPERS LINE, ABC LINE SOLAR PLANT AND ADJOINING AREA UNDER AGE EM II OF GE (U) SECUNDERABAD; 1 Supply & Replace in replacement MCCB along with both side spreader link and nut bolts of appropriate size (Conforms to IEC:60947-II/IS:13947-II) in exisitng LT Panel box/Feeder Pillar boxes (KIOSK), in MCCB DBs of capacity 630 Amps, 4 Pole, 35 KA, 415 Volt including disconnecting/ taking out existing old unsv/burned MCCB complete all as specified and directed. 2 All as per item No 1.00 here in before but of capacity 315-400 Amps, 4 pole, 36 KA 3 All as per item No 1.00 here in before but of capacity 250 Amps, 4 pole, 36 KA 4 All as per item No 1.00 here in before but of capacity 200 Amps, 4 pole, 36 KA 5 All as per item No 1.00 here in before but of capacity 160 Amps, 4 pole, 36KA 6 All as per item No 1.00 here in before but of capacity 125 Amps, 4 pole, 16 KA 7 All as per item No 1.00 here in before but of capacity 100 Amps, 4 pole, 16 KA 8 All as per item No 1.00 here in before but of capacity 63 Amps, 4 pole, 16 KA 9 S&F in replacement MCCB, 63 Amps, 3 pole, 415 Volts with breaking capacity 16KA, including disconnecting/ taking out existing old unsv/ burned MCCB complete all as specified and directed. 10 All as per item No 9.00 here in before but of capacity 100 Amps, 3 pole, 415 Volts with breaking capacity 16KA 11 All as per item No 9.00 here in before but of capacity 160 Amps, 3 pole, 415 Volts with breaking capacity 16KA 12 S&F in replacement MCB, SP 6-32 Amps, C Curve with breaking capacity 10KA, including disconnecting/ taking out existing old unsv/ burned Isolator complete all as specified and directed. 13 Supply and fixing in replacement of automatic street light switch using infrared sensor based nature switch for automatic switching of street lights.Nature switch operation should bebased on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off > 10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs.The sensor along with suitable power contactors incoming outgoing MCBS SP and and automanual (sensor bypass selection option should be enclosed in a pole /wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade SMC Box conforming to IP54 single phase load of 8 KW with circuit wiring min 10 sq mm copper wire 63 Amps contactor ans suitable MCBs at both positions at incoming and out goings of breaking capacity 10 KA complete including necessary clamp (2 sets) / anchor bolt(4 nos) for fixing on pole / walll complete all as directed including taking down old one . Model no Swadeep-02 EC 8KW 1P or equivalent from Havells/Legrand . 14 Supply and fixing in replacement of automatic street light switch using infrared sensor based nature switch for automatic switching of street lights.Nature switch operation should bebased on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off > 10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs.The sensor along with suitable power contactors incoming outgoing MCBS SP and and automanual (sensor bypass selection option should be enclosed in a pole /wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade SMC Box conforming to IP54 three phase load of 12 KW with circuit wiring min 10 sq mm, 3 nos contactor each of 40 - 50 amps, incoming outgoing MCB (3 nos) rating 40 amps of breaking capacity 10 KA complete including necessary clamp (2 sets) / anchor bolt(4 nos) for fixing on pole / walll complete all as directed including taking down old one Model no Swadeep-02 EC 12KW 3P or equivalent from Havells/Legrand . 15 Supply, lay, commissioning and testing of cable jointing Kit Heat shrinkable type for 1100V grade cable for straight through joint with jointing material and accessories suitable for LT UG cable of size 16 to 50 Sqmm, 3.5 Core complete all as specified and directed. 16 All as per item No 15.00 above but suitable for aluminium conductor cable of size from 70 sqmm, 3.5 Core to 95 Sqmm, 3.5 Core 17 All as per item No 15.00 above but suitable for aluminium conductor cable of size from 120 sqmm, 3.5 Core to 185 Sqmm, 3.5 Core 18 All as per item No 15.00 above but suitable for aluminium conductor cable of size from 240 sqmm, 3.5 Core to 240 Sqmm, 3.5 Core 19 M&L for repairing of automatic operation of highmast lantren including all arrangements required including crane and replacement of all unserviceable spares of highmast lighting system of height 12 m to 16 meter . Quoted rates deemed to be inclusive of the following:-(i) crane as required for taking down of high mast pole including light without any damage to the mast, lantern and lights etc and refixing the same after repairing of the all problem on the same position(ii) Necessary disconnection and reconnection of electrical connection. (iii) Replacement of all unserviceable spare like High mast head, high mast ring , stainless steel wire, clamp, winch, transition plate, service door , Hook ring, nose plate, cabinet, gear, reel, transmission belt etc including servicing of gear box , filling of gear oil, greasing etc complete (quoted rates deemed to be inclusive of all spares required for proper functioning of lantern system except stainless steel wire, High mast head, high mast ring etc. 20 Supply only steel wire rope 6mm dia (7/19 construction) suitable for highmast system including u bolt complete all as directed 21 Taking down, transport to workshop , Re-winding of electric motor 3 phase installed at highmast pole of capacity upto 2.2/3 HP and refixing of the same including necessary arrangement complete all as directed 22 Supply and lay in replacement of cable lay in trenches/fixed to walls/poles etc connecting buy using lugs, testing and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with stranded aluminium conductor 4 Core 25 Sqmm complete all, as specified and directed.Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately. 23 All as per item No 22.00 above but 3.5 Core 35 Sqmm 24 All as per item No 22.00 above but 3.5 Core 50 Sqmm 25 All as per item No 22.00 above but 3.5 Core 70 Sqmm 26 All as per item No 22.00 above but 3.5 Core 95 Sqmm 27 All as per item No 22.00 above but 3.5 Core 120 Sqmm 28 All as per item No 22.00 above but 3.5 Core 150 Sqmm 29 All as per item No 22.00 above but 3.5 Core 185 Sqmm 30 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/ dense soil for foundation of poles, structures, stay rods, laying of underground cable etc complete all as directed by Engr-in-Charge. 31 Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed. 32 Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 33 Spreading riddled earth (after preparation of excavated earth) in Cable duct with sand cushioning of cable laid in trenches complete all as directed by Engineer-in-Charge.Note:- Punned thickness 18 CM( 6.25 Cm below cale and 11.75 cm above cable) will be measured for payment purpose. Quoted rate inclusive of all arrangement as mentioned. 34 Supply and Laying bricks, common burnt clay building bricks, sub class B of size 230 x 115 x 75 mm laid across in trenches for cable protection complete all as specified and directed. 35 Cutting the existing road/ PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed. 36 M&L for road crossing/ drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by hydarulic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, HDPE pipe medium duty duty of size 100 mm dia in any length including jointing materials to carry LT UG cables of size upto 240 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed. 37 M&L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm thick and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia MS deformed bars @ 100 mm centre to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed. 38 M&L in replacement of earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron earth strip 32 mm x 6 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40mm bore light grade and connected pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, (in any type of strata ) charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete.Note:-(i) GI strip 32 x 6 mm upto 7.5 mtr length shall be deemed to include in this items rate.(ii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost by the contractor. 39 S&F in replacement of Galvanised Iron Strip 32x6mm with Saddles and fixing Screws for Roof/ Earth Conductors and Down Conductors above Ground including taking down unserviceable Strip, complete all as specified and as directed.NOTE : All Joints should be joined by Brazing or by using of nuts and bolts& washers. 40 S&F in replacement of Galvanised Iron Tubing/ Pipe 40mm bore (dia), light grade for Strip Protection, fixed in Walls/ Floors with suitable type of Clamps, etc. including taking down unserviceable GI Tubing/ Pipe, complete all as specified and as directed. 41 Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen ded by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat of Size 4 Sqmm complete all as specified and directed. 42 All as per item No 44.00 above but of size 6 Sqmm complete all as specified and directed. 43 All as per item No 44.00 above but of size 10 Sqmm complete all as specified and directed. 44 S&F in replacement of hot press moulded SMC junction/terminal box of size with internal diamensions of 200 x 140 x 95 mm with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/glands, fixed on pole by means of clamps made out of MS flat iron of size 25mm x 3 mm 2 Set including dismantling of old unserviceable all as specified and as directed. Make : Syntex/C&S/Havells. 45 Supply and laying in replacement of GI tubing light grade of size 40 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm with ISI marked. 46 Supply and laying in replacement of GI tubing light grade of size 50 mm for cable protection on road/drain/floor/pole including necessary clamps with ISI marked. 47 Supply and laying in replacement of GI tubing light grade of size 80 mm for cable protection on road/drain/floor/pole including necessary clamps with ISI marked. 48 S&F in replacement of On-Load changeover switch with sheet steel enclosure, (Side Handle), 4 pole of capacity 400 Amps, 415 Volts, 50 Hz, complete all as specified and directed. 49 S&F in replacement of off-Load changeover switch with sheet steel enclosure, (Side Handle), 4 pole of capacity 200 Amps, 415 Volts, 50 Hz, complete all as specified and directed. 50 S&F off-Load changeover switch with sheet steel enclosure, (Side Handle), 4 pole of capacity 100 Amps, 415 Volts, 50 Hz, complete all as specified and directed. 51 Supply only of aluminium cable lugs of following sizes :-Make : Dowell/Jaison. 52 16 to 25 Sqmm Size 53 35 to 50 Sqmm Size 54 70 to 95 Sqmm Size 55 120 to 150 Sqmm Size 56 185 to 240 Sqmm Size. 57 S&F in replacement of MCCB factory made enclosure box with neutral link for TPN System made of sheet metal Powder coated Suitable for fixing at Pole including two set of clamps comprising with the following i) S&F of MCCB 63 Amps 16 KA TP 58 S&F in replacement of MCCB factory made enclosure box with neutral link for TPN System made of sheet metal Powder coated Suitable for fixing at Pole including two set of clamps comprising with the following i) S&F of MCCB 100 Amps 16 KA TP 59 Supply and fixing in replacement of lantren of dia 60 CM for fixing of flood light, cap type to be fixed on the top of 9 m SP-31 Steel pole , made of MS pipe medium grade dia greater than the top dia of the pole of length 0.35 M supported by MS flat iron of size 50X6 mm 8 nos including two coat of aliminium painting over a coat of redoxide primer complete all as directed 60 M&L for Servicing of ACB Breaker indoor/ outdoor type of any make/ model/ capacity, checking of switching ON/OFF & tripping system, Spring charge Motor working system,checking of all electrical mechanical components of AMF panel and Setting the same for proper working of Breaker, testing of operation manually and auto mode complete all as directed by Engr-in-charge.Note:-All the mechanical parts are thoroughly cleaned by suitable cleaning agent & moving parts are properly lubricated 61 Supply and fixing in replacement only power factor correction capacitor, 5 KVAR, heavy duty 440 volts 50 Hz complete including taking down old unserviceable capacitor complete all as specified and directed. 62 All as per item No 59.00 above but 10 KVAR Capacitor Bank 63 All as per item No 59.00 here-in-before but 20 KVAR Capacitor Bank 64 Supply and fixing in replacement only capacitor duty contactor suitable for rating 5 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. 65 All as per item No 62.00 above but 10 KVAR capacitor duty contactor 66 All as per item No 62.00 here-in-before but 20 KVAR capacitor duty contactor 67 S&F in replacement APFC relay with auto-set functiont 7/8 stage APFC relay 68 Supply & Fixing in replacement of Auto/ Manual selector swtich in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. 69 M&L for preparation of old painted surfaces for outdoor/indoor Amf panel/LT Panel of any size with applying two coat of synthetic enamelled grey paint after removing all dust & rust and paint shall confirm to IS 2032 complete all as specified . 70 Supply, Installation, test and Commissioning in replacement of factory fabricated, out door type, Bus bar panel made out of 3.15 mm thick CRCA Sheet of size 1MX.75mX.35M with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level complete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :– 71 (a) Aluminium bas bar 200amps - 04 Nos in 3 Phase and Half neutral fashion, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. 72 b) MCCB 100 amps ,415 volt ,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As INCOMING - 01 Nos 73 Supply and install, testing and commissioning in replacement of Out door LT feeder panel of 400 Amps, factory made cubicle type of suitable size and 3.15 mm thick CRCA sheet outdoor type vermin proof with Aluminium bus bar of size 40 mm x 10 mm, Al strip 3 phase and neutral connections with neutral colour coded with heat and shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painted with one coat of red oxide primer and two coats of powder coated paint with suitable size of panel control copper wiring, accessories are fitted on suitable insulator all housed in suitable bus bar chamber and provision and fixing of digital Voltmeter,Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands incl PCC foundation etc complete testing and commissioning complete and consisting the following :- 74 (a) MCCB 4 Pole 400 Amps 36KA -01 No. Thermal Magnetic release (incommer)(b) MCCB 4 Pole 200 Amps 25KA -01 Nos. (Outgoing)(c) MCCB 4 Pole 160 Amps 25KA -02 Nos. (Outgoing)(d) MCCB 4 Pole 100 Amps 16KA -03 Nos. (Outgoing)(e) Digital multimeter operated on 400/5A LT-CT operated complete - 01 No(e) Indicating type lamp for Red, Yellow and Blue phases - 01 SetNote : (a)All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item..(b) The cost shall also be include the breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces 75 Supply and install, testing and commissioning in replacement of Out door LT feeder panel factory made cubicle type of suitable size and 3.15 mm thick CRCA sheet outdoor type vermin proof with suitable size Aluminium bus bar with neutral colour coded with heat and shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painted with one coat of red oxide primer and two coats of powder coated paint with suitable size of panel control copper wiring, accessories are fitted on suitable insulator all housed in suitable bus bar chamber and provision and fixing of digital multimeter, CTs of suitable ratio, and pilot indication lamps complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands incl PCC foundation etc complete testing and commissioning complete and consisting the following :- 76 (a) MCCB 4 Pole 160 Amps 36KA -01 No. Thermal Magnetic release (incommer)(b) MCCB 4 Pole 100 Amps 16KA -02 Nos. (Outgoing)(d) MCB SP Pole 32 Amps 10KA -01 Nos. (Outgoing)`(e) Digital multimeter with CT 400/5A LT-CT operated complete - 01 Set(e) Indicating type lamp for Red, Yellow and Blue phases - 01 SetNote : (a)All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item..(b) The cost shall also be include the breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces 77 Supply , fixing , connecting and commissioning and testing in replacement of Outdoor type (automatic and manual operation) power factor improvement panel of capacity 20 Kvar including interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor/Indoor) type panel factory made, weather proof , dust and vermin proof suitable for 1100 V/440 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 3.15mm thick CRCA Sheet and having four Nos angle iron legs made out of 50 x 50 x 6mm 75 cm long angle iron below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with siemens grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size upto 30 cms including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles with on line monitring of Power Factor on web based application as specified and directed by Engr-in-Charge.Note :- Amount of PCC is deemed in the item rate and no other amount will be paid to contractor on this account 78 Incoming feeder:- 79 A. Incommer MCCB 63- Amp , Three Pole, Thermal based release with adjustable O/L ,Adj S/C Setting Front Face, 16KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.- 1 No 80 B. Metering Section- Digital Ammeter (0-150)Amps, digital Volt Meter (0-500)Volts , RYB Indicating Lamps ,1 Set Control fuses, CTs. 3 81 C. Insulated Busbar of Aluminium of 100A Capacity for 3 phase,, fixed on Insulators, Busbar Should be PVC Sleeved with red. Yellow. Blue Colour, Busbar Support should be of smc/dmc - 1 set. 82 D. Multi 6 Step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display. 83 Outgoing feeder :- 84 E. Accessories for 1 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 1 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor, on indicators and selector switch. 85 F. Accessories for 2 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 2 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. 86 G. Accessories for 3 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 4 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. 87 H. Accessories for 4 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 4 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. 88 J. Accessories for 10 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 10 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 20 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. 89 K. Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/off of fans depending upon the temperature of the pane; 230vac 1500rpm, 160cu.m/h flying leads 90 L. 6 Steps Automatic Power Factor controller steps Relay Micro proccessor based for switchting ON and OFF of capacitors to Display of voltage ,current,Active power ,apparent Power display of COS Ø ,THD voltage ,THD current,alarm indication for defective step,low power factor and axcess temperature.The relay having volt free c/o contact,automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement.Switching programm :LIFO combi Filter ,manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 440 volt ,45 to 65 HZ,current measuring 10MA-5A suitable for CT x/1A andx/5A commissing without additional setting and programming.Three decimal power reading .Phasing out of fault capacitor bank Automatically . 91 M. All accessories prewired with suitable size copper Wire withstand high temperature, housed in cubical panel made out of 3.15mm thick CRCA Sheet factory made duly powder coated front and rear door openable with locking arrangement complete with foundation as required or recommended by manufacturer. 92 Supply, fixing, connecting and commissioning and testing in replacement of outdoor type (automatic and manual operation) power factor improvement panel of capacity 30 Kvar including interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor/Indoor) type panel factory made, weather proof , dust and vermin proof suitable for 1100 V/440 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 3.15mm thick CRCA sheet and having four Nos angle iron legs made out of 50 x 50 x 6mm 75 cm long angle iron below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with siemens grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground upto 30 cms in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles with on line monitring of Power Factor on web based application as specified and directed by Engr-in-Charge. 93 Incoming feeder:- 94 A. Incommer MCCB 63- Amp , Three Pole, Thermal based release with adjustable O/L ,Adj S/C Setting Front Face, 16KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.- 1 No 95 B. Metering Section- Digital Ammeter (0-150)Amps, digital Volt Meter (0-500)Volts , RYB Indicating Lamps ,1 Set Control fuses, CTs. 3 96 C. Insulated Busbar of Aluminium of 100A Capacity for 3 phase,, fixed on Insulators, Busbar Should be PVC Sleeved with red. Yellow. Blue Colour, Busbar Support should be of smc/dmc - 1 set. 97 D. Multi 6 Step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display. 98 Outgoing feeder :- 99 E. Accessories for 1 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 1 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor, on indicators and selector switch. 100 F. Accessories for 2 KVAR Capacitor Bank - 2 Nos :- Capacitor Duty Contactor 2 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. 101 G. Accessories for 3 KVAR Capacitor Bank - 2 Nos :- Capacitor Duty Contactor 4 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. 102 H. Accessories for 4 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 4 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. 103 J. Accessories for 5 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 5 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. 104 K. Accessories for 10 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 10 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 20 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. 105 L. Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/off of fans depending upon the temperature of the pane; 230vac 1500rpm, 160cu.m/h flying leads 106 M. 10 Steps Automatic Power Factor controller steps Relay Micro proccessor based for switchting ON and OFF of capacitors to Display of voltage ,current,Active power ,apparent Power display of COS Ø ,THD voltage ,THD current,alarm indication for defective step,low power factor and axcess temperature.The relay having volt free c/o contact,automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement.Switching programm :LIFO combi Filter ,manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 440 volt ,45 to 65 HZ,current measuring 10MA-5A suitable for CT x/1A andx/5A commissing without additional setting and programming.Three decimal power reading .Phasing out of fault capacitor bank Automatically . 107 N. All accessories prewired with suitable size copper Wire withstand high temperature, housed in cubical panel made out of 3.15mm thick CRCA Sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer. 108 Supply, fixing, connecting and commissioning and testing of outdoor type (automatic and manual operation) power factor improvement panel of capacity 70 Kvar including interconnection with LT panel with appropriate size of electric cable for transformer (Outdoor/Indoor) type panel factory made, weather proof , dust and vermin proof suitable for 1100 V/440 V grade 3 phase 50 HZ AC supply floor mounted , fabricated out of 3.15mm thick CRCA sheet and having four Nos angle iron legs made out of 50 x 50 x 6mm 90 cm long angle iron below frame with front door and Side/Back opening having locking arrangement prewired with copper conductor PVC insulated flexible wire size 1.5 sq mm / extension strips and connected with suitable size thimbles , lugs duly painted with siemens grey epoxy powder coating after suitable chemical treatment , legs duly embedded in ground upto 45 Cms in PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) of suitable size including locking arrangement suitable for mounting , with required sheet metal enclosures, thimbles with on line monitring of Power Factor on web based application as specified and directed by Engr-in-Charge. 109 Incoming feeder:- 110 A. Incommer MCCB 125- Amp , Three Pole, Termal based release with adjustable O/L ,Adj S/C Setting Front Face, 16 KA rupturing capacity, Ics=100%Icu, Isolation with Positive Break Indication with Double Break Contacts, Standard Extended Rotary Handle, Spreaders, Phase Barrier.- 1 No 111 B.Metering Section- Digital Ammeter (0-150)Amps, digital Volt Meter (0-500)Volts , RYB Indicating Lamps ,1 Set Control fuses, CTs. 3 112 C. Insulated Busbar of Aluminium of 150A Capacity for 3 phase,, fixed on Insulators, Busbar Should be PVC Sleeved with red. Yellow. Blue Colour, Busbar Support should be of smc/dmc - 1 set. 113 D. Multi 7 Step 440V, 5A (144 x 144) microprocessor based power factor controller provided in the command module for target power factor setting, automatic adjustment of dead bank ratio, digital power factor display. 114 Outgoing feeder :- 115 E. Accessories for 1 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 1 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor, on indicators and selector switch. 116 F. Accessories for 2 KVAR Capacitor Bank - 2 Nos :- Capacitor Duty Contactor 2 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. 117 G. Accessories for 5 KVAR Capacitor Bank - 3 Nos :- Capacitor Duty Contactor 8 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 10 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. 118 H. Accessories for 10 KVAR Capacitor Bank - 1 Nos :- Capacitor Duty Contactor 10 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 20 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. 119 J. Accessories for 20 KVAR Capacitor Bank - 2 Nos :- Capacitor Duty Contactor 20 kvar with Damping Resistors which limits inrush current 440 volt, 3phase , 50 hz , coil-220vac ,MCB TP 63 A having breaking capacity 10 KA with std. duty capacitor on indicators and selector switch. 120 K. Ventilating fans of required size to dissipate the heat liberated by capacitor unites complete with automatic switching on/off of fans depending upon the temperature of the pane; 230vac 1500rpm, 160cu.m/h flying leads 121 L. 10 Steps Automatic Power Factor controller steps Relay Micro proccessor based for switchting ON and OFF of capacitors to Display of voltage ,current,Active power ,apparent Power display of COS Ø ,THD voltage ,THD current,alarm indication for defective step,low power factor and axcess temperature.The relay having volt free c/o contact,automatic detection and uses of optimum capacitor capable of 4 Quadrant operation and any phase offset requirement.Switching programm :LIFO combi Filter ,manual mode built in under and over voltage release with auto reset large voltage input band of 90V to 440 volt ,45 to 65 HZ,current measuring 10MA-5A suitable for CT x/1A andx/5A commissing without additional setting and programming.Three decimal power reading .Phasing out of fault capacitor bank Automatically . 122 M. All accessories prewired with suitable size copper Wire withstand high temperature, housed in cubical panel made out of 3.15mm thick CRCA Sheet factory made duly powder coated front and rear door openable with locking arrangement complete with foundation as required or recommended by manufacturer. 123 S&F in replacement MCB, SPN 32 Amps, C Curve with breaking capacity 10KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed. 124 S&F in replacement MCB, TP 25-63 Amps, C Curve with breaking capacity 10KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed. 125 Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail