Work Of Supply And Erection Of Additional Equipments/Items For New 200Kva Transformers (02Nos) Alongwith Rmu Including Civil Works Under Revamped Distribution Sector Scheme (Rdss), Under The Jurisdiction Of Elect. Sd-I, Division-Vii, Curchorem-Material Cost (Materials which are shown under erection & which are not shown under material will be supplied departmentally. 2 Supply of 11KV, 3 core, 300 sq.mm. aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable 3 Supply of 11KV, 3 core 95sq.mm aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable 4 Supplyof straight through joint complete for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets/lugs/connectors etc. . 5 Supplyof 3 WAY RMU ,11KV, 630 Amps,21 kA, 3 sec, SF6 Outdoor RMU- 2 LBS+ 1 CB Extension/Non-Extendable Two(2) Motor operated load break switches (LBS) with Manual operated earthing switches in SF6 and One (1) vaccum circuir breaker with electrical closing and tripping along with disonnector and earthing switches SCADA Compatible and basic channel. Battery charger along woth batetried required for electrical opearations of RMU is in the scope of bidder .Each module shall consisit of VPIS,FPIin LBS Module(N-1) but not less than 1 nos per RMU. Suitable arranegment for mounting FRTU, modem or Ethernet Switch/LIU along with baterry, battery charger shall be provided in RMU 6 Supply of 11KV, 3 ½ Core,240 sq.mmXLPE Armoured cable, 1.1KV Grade 7 Supply & fixing of Modem for Automatic meter reading 8 Supply of Enamelled Danger boards for 11 KV Enamelled danger board 440Volts/ 11000 Volts /3300 Volts:The plate should be made from mild steel at least 1.6mm thick and vitreous enamelled whitewith letters,figures, and convectional skull and bones in singnal red colour on the front sidfe. The rear side of the plate shall be enamelled .All lettering should be centrally spaced the corners of the plate should be rounded offSizw 250mm x 200mm. 9 Supply of RCC Cable route Markers (400 x 900 x 100 mm) 10 Supply ofRCC protective covers of size 480mm longx 250mm width and 50 mm thick capable of bearing loadof 135 Kg. And covered with earth/sand upto depth of 0.15 mts. Conforming to IS 1255-1967 at non-road crossing 11 Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing , completea) Sand 12 Supplyof HDGI flat of size 25mm x 5mm for earthing ofRMUs 13 Supply and providing Cement concrete 1:2:4Supply & Providing ofOrdinary Portland Cement of grade 43 in HDPE bags of 50 KGs conforming to IS 8112.Cement should be filled in bags as per IS Specification. All bags should have ISI mark. The cement supplied shall be fresh and shall not be more than one month old from the date of manufacture. Cement concrete in the ratio 1:2:4(1 cement: 2 Sand, 4 graded granite/basaltic, aggregate 20mm nominal size) including cost of centering, shuttering & muffing 0.4mts above the ground & properly curved. 14 Supply & providing of Centering and shuttering including struttings, propping etc. and removal of formwork for a) Foundations, footings, bases of columns and mass concrete forRMUs 15 Supply ofGI pipe,150mm dia, Class B for bridge crossing. 16 Supply & providing of 12 mm cement plaster 1:4 ( 1 cement: 4 fine sand) for foundations ofRMUs 17 Supplyof 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x95 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side. 18 Supplyof 11KV 3 phase indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side . 19 Erection Cost 20 Laying of 11KV, 3 core, 300 sq.mm. aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable 21 Laying of 11KV, 3 core 95sq.mm aluminium, XLPE insulated, flat wire armoured, 11 KV (Earthed) Cable 22 Erection of straight through joint complete for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets/lugs/connectors etc. . 23 Erection, testing & comissioning of 3 WAY RMU ,11KV, 630 Amps,21 kA, 3 sec, SF6 Outdoor RMU- 2 LBS+ 1 CB Extension/Non-Extendable Two(2) Motor operated load break switches (LBS) with Manual operated earthing switches in SF6 and One (1) vaccum circuir breaker with electrical closing and tripping along with disonnector and earthing switches SCADA Compatible and basic channel. Battery charger along woth batetried required for electrical opearations of RMU is in the scope of bidder .Each module shall consisit of VPIS,FPIin LBS Module(N-1) but not less than 1 nos per RMU. Suitable arranegment for mounting FRTU, modem or Ethernet Switch/LIU along with baterry, battery charger shall be provided in RMU 24 Layingof 11KV, 3 ½ Core,240 sq.mmXLPE Armoured cable, 1.1KV Grade 25 Fixing of Enamelled Danger boards for 11 KV Enamelled danger board 440Volts/ 11000 Volts /3300 Volts:The plate should be made from mild steel at least 1.6mm thick and vitreous enamelled whitewith letters,figures, and convectional skull and bones in singnal red colour on the front sidfe. The rear side of the plate shall be enamelled .All lettering should be centrally spaced the corners of the plate should be rounded offSizw 250mm x 200mm. 26 Erection of RCC Cable route Markers (400 x 900 x 100 mm) 27 Laying of RCC protective covers of size 480mm longx 250mm width and 50 mm thick capable of bearing loadof 135 Kg. And covered with earth/sand upto depth of 0.15 mts. Conforming to IS 1255-1967 at non-road crossing 28 Excavation in any type of soil including hard laterite soil by mechanical means( hydraulic excavator)/manual means for laying of HT/ LT cables of various sizes including excavation for equipment foundations i.e for RMUs including getting out the excavated soil and disposal of surplus excavated soil. 29 Refilling of excavated soil in the foundations, trenches etc. with available excavated earth in layers not exceeding 20 cm depth, cosolidating each layer by ramming and watering lead upto 50 M and all lifts and disposal of surplus earth in cable trenches and foundations of equipments. 30 Erection of HDGI flat of size 25mm x 5mm for earthing ofRMUs 31 Laying ofGI pipe,150mm dia, Class B for bridge crossing. 32 Re-instatement of Roads 33 Erection of 11KV, 3 phase, Indoor type, heat shrinkable end termination kit complete, for 11 KV XLPE cable of size 3 x95 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side . 34 Erection of 11KV 3 phase indoor terminating kit complete, for 11 KV XLPE cable of size 3 x 300 sq.mm including sockets/lugs/connectors etc. for connecting RMU for main section side .